Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Design and performance evaluation of a dual-circuit thermal energy storage module for air conditioners

We present experimental results and a validated numerical model of a dual-circuit phase-change thermal energy storage module for air conditioners. The module incorporates a phase-change material encapsulated in compressed expanded natural graphite foam. We used n-tetradecane as the PCM with a transition temperature (~4.5 °C) suitable for air-conditioning applications. Heat exchange to and from the module is accomplished through two fluid loops operating as a heat source and sink embedded inside multiple slabs of the composite material. This dual-circuit design enables easier integration with air-conditioning equipment and provides enhanced flexibility in system operation as compared to the state-of-the-art thermal storage systems. When integrated with an air-conditioner, this design will enable peak-load shaving and enhances operational efficiency. The thermal storage device was designed for a nominal storage capacity of ~ 3.5 kWh. We evaluated the heat transfer and energy storage performance of this device using standalone heat transfer experiments to estimate key thermal resistances and identify design improvements before integration with an air conditioner. The numerical model of the heat exchanger uses a combination of discretized and lumped parameter approaches to maintain a balance between accuracy and computational expense. Our analyses show that the geometric features and integration of fluid tubes are key contributors to the thermal contact resistance between the fluid and the thermal storage material, and consequently, to the overall performance of the thermal storage module. Our standalone experiments also identified important operating scenarios in which this thermal storage module can be used for air-conditioning in buildings.

25 ENERGY STORAGE↗

Public Health Response and Medical Management of Internal Contamination in Past Radiological or Nuclear Incidents: A Review

Following a radiological or nuclear emergency, workers, responders and the public may be internally contaminated with radionuclides. Screening, monitoring and assessing any internal contamination and providing necessary medical treatment, especially when a large number of individuals are involved, is challenging. Experience gained and lessons learned from the management of previous incidents would help to identify gaps in knowledge and capabilities on preparedness for and response to radiation emergencies. In this paper, eight largescale and five workplace radiological and nuclear incidents are reviewed cross 14 technical areas, under the broader topics of emergency preparedness, emergency response and recovery processes. The review findings suggest that 1) new strategies, algorithms and technologies are explored for rapid screening of large populations; 2) exposure assessment and dose estimation in emergency response and dose reconstruction in recovery process are supported by complementary sources of information, including ‘citizen science’; 3) surge capacity for monitoring and dose assessment is coordinated through national and international laboratory networks; 4) evidence-based guidelines for medical management and follow-up of internal contamination are urgently needed; 5) mechanisms for international and regional access to medical countermeasures are investigated and implemented; 6) long-term health and medical follow up programs are designed and justified; and 7) capabilities and capacity developed for emergency response are sustained through adequate resource allocation, routine nonemergency use of technical skills in regular exercises, training, and continuous improvement.

61 RADIATION PROTECTION AND DOSIMETRY↗

Thermophysical properties of low cost lithium nitrate salts produced in northern Chile for thermal energy storage

In recent years, lithium containing salts have been studied for thermal energy storage (TES) applications because of their excellent thermophysical properties. In solar power plants, lithium is seen as a way to improve the properties of state-of-the art molten salts used today. Lithium nitrate is a good candidate for sensible heat storage, because of its ability to increase the salt mixture's working temperature range. In the present research, thermophysical properties characterization of lithium nitrate containing salts, produced in Chile, have been carried out. Corrosion evaluations at 390° and 565 °C for 1000 h were performed for low chromium steel T22 and stainless steels (AISI 430 and AISI 316), respectively. Chemical composition of the salts including identification of corrosion products and impurities was determined and an estimation of the Chilean production costs is reported. The study shows a loss of thermal properties after the corrosion tests. The heat capacity was reduced, possibly caused by the formation of oxides at high temperatures. As a result, the partial thermal decomposition of the salt was probably produced by the incorporation of corrosion products from the steel.

25 ENERGY STORAGE↗

Power Law Growth and Delayed Feedbacks in Socio-Hydrological Systems

Water infrastructure dynamics result from coupled social and physical hydrological processes embedded in “socio-hydrological systems” (SHSs). Freshwater fuels socioeconomic activity, which in turn exerts pressure on water resources through increased water demand and water quality degradation. Many factors emphasize the need for quantitative tools to predict the future of these systems, including SHS failures due to growing water scarcity from population growth and climate change. However, unfolding the interactions between social and hydrological factors continues to resist theoretical treatment, impeding progress toward a predictive framework. To resolve this issue, we propose and evaluate time delays as surrogates for the social dynamics in SHS models. This approach permits the development of models that describe SHS dynamics in terms of observable, physical, hydrological state variables. We apply this approach to two case studies: (a) reservoir storage capacity growth in the world and the U.S. Water Resources Regions and (b) global water withdrawals. Substantial variability was identified in empirical estimates of growth rates and time delays. Reservoir construction typically follows a saturating, logistic curve with periodic, punctuated equilibria, separated by delays ranging from 5 to 20 years both globally and regionally. In contrast, global water withdrawal data display faster-than-exponential growth, characteristic of a positive feedback through which water use drives further water development. Historical analysis suggests that growth trends in water resources systems are superimposed by recurring periods of innovation and inactivity which are indicative of slow memory dissipation and delayed effects of past water use on current water infrastructure decisions.

54 ENVIRONMENTAL SCIENCES↗

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN↗

FY-2015 Methyl Iodide Deep-Bed Adsorption Test Report

Nuclear fission produces fission and activation products, including iodine-129, which could evolve into used fuel reprocessing facility off-gas systems, and could require off-gas control to limit air emissions to levels within acceptable emission limits. Deep-bed methyl iodide adsorption testing has continued in Fiscal Year 2015 according to a multi-laboratory methyl iodide adsorption test plan. Updates to the deep-bed test system have also been performed to enable the inclusion of evaporated HNO 3 and increased NO 2 concentrations in future tests. This report summarizes the result of those activities. Test results showed that iodine adsorption from gaseous methyl iodide using reduced silver zeolite (AgZ) resulted in initial iodine decontamination factors (DFs, ratios of uncontrolled and controlled total iodine levels) under 1,000 for the conditions of the long-duration test performed this year (45 ppm CH3I, 1,000 ppm each NO and NO 2 , very low H 2 O levels [3 ppm] in balance air). The mass transfer zone depth exceeded the cumulative 5-inch depth of 4 bed segments, which is deeper than the 2-4 inch depth estimated for the mass transfer zone for adsorbing I 2 using AgZ in prior deep-bed tests. The maximum iodine adsorption capacity for the AgZ under the conditions of this test was 6.2% (6.2 g adsorbed I per 100 g sorbent). The maximum Ag utilization was 51%. Additional deep-bed testing and analyses are recommended to (a) expand the data base for methyl iodide adsorption and (b) provide more data for evaluating organic iodide reactions and reaction byproducts for different potential adsorption conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NETL Gen-2 Oxygen Carrier Assessment

The National Energy Technology Laboratory’s (NETL) Research and Innovation Center (RIC) has been conducting laboratory-scale tests to develop a new chemical looping combustion (CLC) oxygen carrier (OC) having copper, iron, and alumina components. This OC, designated as the Gen-2 OC throughout this report, has high maximum oxygen capacity and has been tested extensively in the RIC methane-fueled chemical looping reforming. A screening analysis has been conducted to estimate the performance and cost of CLC when utilizing the Gen-2 OC. In this report, the performance and cost results are compared to those of a range of previously assessed CLC OCs to provide a basis to establish the relative merits and issues associated with the Gen-2 OC. Base load CLC power plants utilizing the Gen-2 OC and the three comparison OCs considered in this assessment (Fe 2 O 3- , CuO-, CaSO 4- based) are estimated to have thermal efficiency and cost of electricity (COE) characteristics potentially superior to those of the equivalent conventional pulverized coal (PC) power plant applying conventional, amine-based CO 2 capture technology. The current assessment does not address flexible plant operation. An evaluation of the CLC plant designed for flexible operation would need to include a comparable PC plant designed for flexible operation.

01 COAL, LIGNITE, AND PEAT↗

Divergent predictions of carbon storage between two global land models: Attribution of the causes through traceability analysis

Representations of the terrestrial carbon cycle in land models are becoming increasingly complex. It is crucial to develop approaches for critical assessment of the complex model properties in order to understand key factors contributing to models' performance. In this study, we applied a traceability analysis which decomposes carbon cycle models into traceable components, for two global land models (CABLE and CLM-CASA') to diagnose the causes of their differences in simulating ecosystem carbon storage capacity. Driven with similar forcing data, CLM-CASA' predicted – 31 % larger carbon storage capacity than CABLE. Since ecosystem carbon storage capacity is a product of net primary productivity (NPP) and ecosystem residence time ( τ E ), the predicted difference in the storage capacity between the two models results from differences in either NPP or τ E or both. Our analysis showed that CLM-CASA'simulated 37 % higher NPP than CABLE. On the other hand, τ E , which was a function of the baseline carbon residence time ( τ ' E ) and environmental effect on carbon residence time, was on average 11 years longer in CABLE than CLM-CASA'. This difference in τ E was mainly caused by longer τ ' E of woody biomass (23 vs. 14 years in CLM-CASA'), and higher proportion of NPP allocated to woody biomass (23 vs. 16 %). Differences in environmental effects on carbon residence times had smaller influences on differences in ecosystem carbon storage capacities compared to differences in NPP and τ ' E . Altogether, the traceability analysis showed that the major causes of different carbon storage estimations were found to be parameters setting related to carbon input and baseline carbon residence times between two models.

54 ENVIRONMENTAL SCIENCES↗

The thermodynamic properties of oxygen and nitrogen. Part 2: Thermodynamic properties of oxygen from 100 R to 600 R with pressure to 5000 psia

An equation of state is presented for liquid and gaseous oxygen for temperatures from 100 R to 600 R and pressures to 5000 psia. The pressure-density-temperature data available from the published literature have been reviewed, and appropriate corrections have been applied to bring experimental temperatures into accord with the International Practical Temperature Scale of 1968. Representative comparisons of property values calculated from the equation of state to measured values are included to illustrate the accuracy of the equation of state. The coefficients of the equation of state were determined by a weighted least squares fit to selected published data, and simultaneously to isochoric heat capacity data, and to data which define the phase equilibrium for the saturated liquid and saturated vapor. The equation of state is estimated to be accurate for the liquid to within 0.1 percent in density, to within 0.2 percent for the vapor below the critical temperature and for states above the critical temperatures to 250 K, and within 0.1 percent for supercritical states at temperatures from 250 K to 300 K. The vapor pressure equation is accurate to within + or - 0.01 K between the triple point and the critical point.

Stewart, R. B.↗

Energy Conservation Alternatives Study (ECAS): Conceptual Design and Implementation Assessment of a Utility Steam Plant with Conventional Furnace and Wet Lime Stack Gas Scrubbers

A study was performed to estimate the technical/economic characteristics of a steam power plant (3500 pounds per square inch gauge, 1000 degrees Fahrenheit / 1000 degrees Fahrenheit) with a coal-burning radiant furnace and a wet lime stack gas scrubber to control sulfur emissions. Particulate emissions were controlled by an electrostatic precipitator operating at 300 degrees Fahrenheit. The stack gas from the scrubber was reheated from 125 degrees Fahrenheit to 250 degrees Fahrenheit as a base case, and from 125 degrees Fahrenheit to 175 degrees Fahrenheit as an alternate case. The study was performed on a basis consistent with the General Electric ECAS Phase II evaluation of advanced energy conversion systems for electric utility baseload applications using coal or coal-derived fuels. A conceptual design of the power plant was developed, including the on-site calcination of limestone to lime and the provision of sludge ponds to store the products of flue gas scrubbing. From this design, estimates were derived for power plant efficiency, capital cost, environmental intrusion characteristics, natural resource requirements, and cost of electricity at an assumed capacity factor of 65 percent. An implementation assessment was performed where factors affecting applicability of the conceptual design power plant in electric utility generation systems were appraised. At 250 degrees Fahrenheit and 175 degrees Fahrenheit stack gas temperatures respectively, the plants showed a cost of electricity of 39.8 and 37.0 mills per kilowatt-hours and overall plant efficiencies of 32 percent and 34 percent.

Brown, Dale H.↗

The effect of atmospheric drag on the design of solar-cell power systems for low Earth orbit

The feasibility of reducing the atmospheric drag of low orbit solar powered satellites by operating the solar-cell array in a minimum-drag attitude, rather than in the conventional Sun pointing attitude was determined. The weights of the solar array, the energy storage batteries, and the fuel required to overcome the drag of the solar array for a range of design life times in orbit were considered. The drag of the array was estimated by free molecule flow theory, and the system weights were calculated from unit weight estimates for 1990 technology. The trailing, minimum drag system was found to require 80% more solar array area, and 30% more battery capacity, the system weights for reasonable life times were dominated by the thruster fuel requirements.

Kyser, A. C.↗

Capsulation Satellite or CapSat: A Low-Cost, Reliable, Rapid-Response Spacecraft Platform

The National Aeronautics and Space Administration (NASA) Goddard's Rideshare Office estimates that between 2013 and 2022, NASA launches of primary satellites will have left unused more than 20,371 kilograms of excess capacity. This equates to hundreds of millions of dollars in launch-vehicle costs going unutilized. To fill this void with a standard CubeSat or SmallSat spacecraft platform, which when required to be more reliable, still will cost in the neighborhood of $1M a kilogram, making it prohibitively expensive. A newly proposed solution, which NASA is pursuing, is called the Capsulation Satellite or CapSat. CapSat is a modularized, pressurized, thermally controlled spacecraft designed to host ruggedized commercially available instrumentation in a terrestrial like environment on orbit. Using a technique that is under review for a patent, CapSat actively manages internal air temperatures in a manner similar to a household thermostat. This gives CapSat high-thermal stability, which, in turn, provides component longevity. CapSat was specifically designed to take advantage of the United States Air Force (USAF) Rideshare Program and the Evolved Expendable Launch Vehicle Secondary Payload Adaptor, or ESPA ring. The ESPA ring comes in two sizes: standard and Grande. CapSat primarily will take advantage of the ESPA Grande to provide a 300-kilogram payload capability per attachment point, with up to four attachment points per ring. This approach combines a high-mass capability with a proven Rideshare mechanical interface and secondary payload management infrastructure. Opportunities for ESPA based co-manifests are continuing to expand. The CapSat program is currently funded to design and build a limited prototype and perform thermal-vacuum testing. CapSat is currently in the concept/study phase for both single missions and constellation of earth- and space-observing missions. One of these studies includes land imaging using state-of-the-art advanced infrared detector technology. This paper will report on the current status of the CapSat hardware design, testing, and results as well as any openly available advanced concept study results. The CapSat solution is intended to be a game-changing paradigm shift. CapSat will repurpose currently available, already-proven technology to reduce spaceflight hardware costs to less than $50,000 per kilogram.

Burt, Joe↗

Favorable tectonic and structural settings of geothermal systems in the Great Basin region, western USA: Proxies for discovering blind geothermal systems

We recently completed a comprehensive inventory of the structural settings of known geothermal systems (426 total, ≥37°C) in the extensional to transtensional terrane of the Great Basin region in the western USA. Of the known systems, ~39% are blind (no surface hot springs or fumaroles), but estimates suggest that as much as 75% of the geothermal resources in the region are blind. The density of geothermal systems and capacity of power plants correlate generally with tectonic strain rates. However, highenthalpy geothermal activity is restricted to regions of extensional to transtensional strain, particularly the northwestern part of the Great Basin directly northeast of the dextral shear zone of the Walker Lane and pull-apart zones within both the Walker Lane and San Andreas fault system. We catalogued systems into eight major groups, based on the dominant pattern of faulting. Of the nearly 250 categorized geothermal fields, we found that step-overs or relay ramps in normal fault zones are the most favorable setting, hosting ~32% of the systems. Such areas are characterized by multiple, commonly overlapping fault strands, increased fracture density, and thus enhanced permeability. Other common settings include a) normal fault terminations (25%), where horse-tailing generates a myriad of closely-spaced faults and thus increased permeability; and b) fault intersections between two normal faults or between normal faults and transverse oblique-slip faults (22%), where multiple minor faults typically connect major structures and fluids can flow readily through highly fractured, dilational quadrants. Less common settings include: a) accommodation zones (9%); b) displacement transfer zones (5%); c) pull-aparts in strike-slip faults (3%); d) bends in normal faults (2%); and e) major range-front normal faults (1%). Pull-aparts and displacement transfer zones are more abundant in the transtensional western part of the Great Basin. Quaternary faults typically lie within or near most of the geothermal systems. Geothermal systems are rare along major range-front faults, possibly due to both reduced permeability in thick zones of clay gouge and periodic release of stress in major earthquakes. Step-overs, terminations, intersections, and accommodation zones correspond to long-term, critically stressed areas, where fluid pathways would more likely remain open in networks of closely-spaced, breccia-dominated fractures. Notably, many higher enthalpy systems are hybrids and contain more than one type of favorable setting (e.g. fault intersection within broad accommodation zone). These data can guide exploration strategies, especially for blind or hidden systems.

15 GEOTHERMAL ENERGY↗

Optimization of Energy Storage System Economics and Controls by Incorporating Battery Degradation Costs in REopt

The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.

battery↗

Renewable electricity capacity planning with uncertainty at multiple scales

Abstract We formulate and compare optimization models of investment in renewable generation using a suite of social planning models that compute optimal generation capacity investments for a hydro-dominated electricity system where inflow uncertainty results in a risk of energy shortage. The models optimize the expected cost of capacity expansion and operation allowing for investments in hydro, geothermal, solar, wind, and thermal plant, as well as battery storage for smoothing load profiles. A novel feature is the integration of uncertain seasonal hydroelectric energy supply and short-term variability in renewable supply in a two-stage stochastic programming framework. The models are applied to data from the New Zealand electricity system and used to estimate the costs of moving to a 100% renewable electricity system by 2035. We also explore the outcomes obtained when applying different forms of CO 2 constraint that limit respectively non-renewable capacity, non-renewable generation, and CO 2 emissions on average, almost surely, or in a chance-constrained setting, and show how our models can be used to investigate the merits of a proposed pumped-hydro scheme in New Zealand’s South Island.

Ferris, Michael C.↗

Comprehensive Assessment of On-And Off-Board Vehicle-To-Grid Technology Performance and Impacts on Battery and the Grid

This project defined, developed, and tested the open standards-based requirements, engineering design and system integration of on and off-vehicle Vehicle-to-Grid technologies both on the grid and on the PEV, to assess their effectiveness in implementing the use cases that create value for the grid, which in turn, can be passed on to the ratepayers and the PEV owners. The project comprised of three key categories of work and four key sub-areas of work. The three key categories were: On-Vehicle V2G, Off-Vehicle V2G, and impact of V2G operation on the battery capacity degradation. The four key sub-areas of work under each of these categories were: defining requirements, implementing the technology, performing system integration testing, and estimating the value of each of the grid services under specific assumptions, on a per-vehicle and on an aggregated basis. The technical implementation demonstrated the validity of standards-based approach to grid integration that led to interoperability, in addition to assessing the operational details with grid constraints imposed at the transformer level. The technology implementation also identified the subtle gaps in the standards definition to close the feedback loop on the accuracy of the standards as written, which are being implemented as revisions to the appropriate protocols. The battery impacts assessment developed a test cycle that the batteries from a real PHEV were subjected to for both the mobility-only and mobility with V2G specific energy cycling. While the battery impact results show a clear incremental degradation in response to additional throughput for V2G application purposes, the amount of additional kWh that can be made available without exceeding the end-of-life capacity definition of the battery at its 10-year warranty period was found to be significant. Given that the PEV battery being exercised during testing was a PHEV battery (smaller energy capacity), and 44% of its usable energy (i.e., SOC) was utilized daily for V2G applications, the EVs with much larger batteries will fare much better, either in terms of extracting more value in terms of incremental kWh for V2G, or in terms of relative incremental degradation of the capacity through the battery lifespan. Further, this battery was the second-generation Lithium-Ion chemistry circa 2015, which is at least two generations ago. Continual improvements in electrochemistry and manufacturing techniques as well as on-board capacity will enable the future batteries to provide even more energy for non-mobility-related services. Finally, the valuation of V2G energy services at the premise, distribution, and the ISO/market level was carried out for both the on-vehicle and off-vehicle cases, to understand both the GHG mitigation and operational efficiency improvements in quantitative terms. The analysis indicates that between $\$400$ and $\$1400$ per year of total value to the grid can be realized. When netted of costs to implement V2G either on or off-vehicle, the net value is available to be shared between the ratepayers and the EV owners. Over the life of the EV, therefore, this value becomes significant and can easily provide both ratepayer and EV owner benefits more than the cost of the equipment, either on or off-board, in addition to providing GHG mitigation benefits both on the grid and on the mobility sides. For these benefits to accrue, the key learnings from both the on- and off-vehicle V2G parts of the project indicate the need for at-scale demonstrations through involvement of real EV owners to validate both the technical feasibility, interoperability, as well as real grid benefits by performing extensive data collection and analysis. This will help inform the grid planners, the program designs, and tariff designers, as well as automotive and equipment manufacturers how best to create their products to maximize grid, ratepayer, and EV owner value.

30 DIRECT ENERGY CONVERSION↗

Application of the Aquifer Impact Model to support decisions at a CO 2 sequestration site

The National Risk Assessment Partnership (NRAP) has developed a suite of tools to assess and manage risk at CO 2 sequestration sites. The NRAP tool suite includes the Aquifer Impact Model (AIM), which evaluates the potential for groundwater impacts from leaks of CO 2 and brine through abandoned wellbores. There are two aquifer reduced-order models (ROMs) included with the AIM tool, a confined alluvium aquifer, and an unconfined carbonate aquifer. The models accept aquifer parameters as a range of variable inputs so they may have broad applicability. The generic aquifer models may be used at the early stages of site selection, when site-specific data is not available. Guidelines have been developed for determining when the generic ROMs might be applicable to a new site. This work considers the application of the AIM to predicting the impact of CO 2 or brine leakage were it to occur at the Illinois Basin Decatur Project (IBDP). Results of the model sensitivity analysis can help guide characterization efforts; the hydraulic parameters and leakage source term magnitude are more sensitive than clay fraction or cation exchange capacity. Sand permeability was the only hydraulic parameter measured at the IBDP site. More information on the other hydraulic parameters could reduce uncertainty in risk estimates. Some non-adjustable parameters are significantly different for the ROM than for the observations at the IBDP site. The generic ROMs could be made more useful to a wider range of sites if the initial conditions and no-impact threshold values were adjustable parameters.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗