Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

HYDROGEN STORAGE SOLUTIONS IN SUPPORT OF DOD WARFIGHTER PORTABLE POWER APPLICATIONS

From Personal Digital Assistants (PDAs) to cell phones our high-tech world, today, is demanding smaller, lighter weight and higher capacity portable power devices. Nowhere has this personal power surge been more evident than in today's U.S Warfighter. The modern Warfighter is estimated to carry from 65 to 95 pounds of supplies in the field with over 30 pounds of this dedicated to portable power devices. These devices include computer displays, infrared sights, Global Positioning Systems (GPS), night vision and a variety of other sensor technologies. Over 80% of the energy needed to power these devices comes from primary (disposable) batteries. It is estimated that a brigade will consume as much as 7 tons of batteries in a 72 hour mission at a cost of $700,000. A recent comprehensive study on the energy needs of the future warrior published by the National Academy of Science in 2004 made a variety of recommendations for average power systems from 20 to 1,000 watts. For lower power systems recommendations included pursuing science and technology initiatives focused on: (1) 300 watt-hours per kilogram (Wh/kg) secondary battery technologies; (2) smart hybrids; and (3) fuel cells (with greater than 6 wt% hydrogen storage). Improved secondary (rechargeable) batteries may be the ideal solution for military power systems due to their ease of use and public acceptance. However, a 3X improvement in their specific energy density is not likely anytime soon. Today's Lithium Ion batteries, at about 150 Wh/kg, fall well short of the energy density that is required. Future battery technology may not be the answer since many experts do not predict more than a 2X improvement in Lithium battery systems over the next 10 years. That is why most auto companies have abandoned all electric vehicles in favor of fuel cells and hybrid vehicles. Fuel cells have very high specific energy densities but achieving high energy values will depend on the energy density and the storage method of its fuel. Improved methods of safely and efficiently storing larger amounts of hydrogen will be a key development area for portable fuel cell power systems. Despite their high potential energy, fuel cells exhibit low power densities. That is why many systems today are going hybrid. Hybrid systems typically combine low energy and high power components with high energy and low power components. Typical configurations include capacitors and fuel cells or batteries and fuel cells. If done correctly, a hybrid system often can have both high energy and high power density even higher than any of the individual components.

08 HYDROGEN↗

Design and performance evaluation of a dual-circuit thermal energy storage module for air conditioners

We present experimental results and a validated numerical model of a dual-circuit phase-change thermal energy storage module for air conditioners. The module incorporates a phase-change material encapsulated in compressed expanded natural graphite foam. We used n-tetradecane as the PCM with a transition temperature (~4.5 °C) suitable for air-conditioning applications. Heat exchange to and from the module is accomplished through two fluid loops operating as a heat source and sink embedded inside multiple slabs of the composite material. This dual-circuit design enables easier integration with air-conditioning equipment and provides enhanced flexibility in system operation as compared to the state-of-the-art thermal storage systems. When integrated with an air-conditioner, this design will enable peak-load shaving and enhances operational efficiency. The thermal storage device was designed for a nominal storage capacity of ~ 3.5 kWh. We evaluated the heat transfer and energy storage performance of this device using standalone heat transfer experiments to estimate key thermal resistances and identify design improvements before integration with an air conditioner. The numerical model of the heat exchanger uses a combination of discretized and lumped parameter approaches to maintain a balance between accuracy and computational expense. Our analyses show that the geometric features and integration of fluid tubes are key contributors to the thermal contact resistance between the fluid and the thermal storage material, and consequently, to the overall performance of the thermal storage module. Our standalone experiments also identified important operating scenarios in which this thermal storage module can be used for air-conditioning in buildings.

25 ENERGY STORAGE↗

Physical control on CCl4 and CHCl3 desorption from artificially contaminated and aged sediments with supercritical carbon dioxide

The long-term interactions of carbon tetrachloride (CCl4) and chloroform (CHCl3) with sediments that are low in organic matter (OM) are not well studied and documented in the literature. In this study, CCl4 and CHCl3 were mixed with supercritical carbon dioxide (CO2) and loaded onto columns packed with two sediments with low OM content and different textures, to establish contamination and achieve expedited artificial aging. The columns were subsequently leached with a simulated groundwater under hydraulically saturated conditions. Scanning electron microscopy was used to inspect the morphology of sediment single particles, determine the degree of particle association in aggregates and qualitatively estimate porosity and the length of possible diffusional pathways that might affect the overall contaminant desorption rates in sediments with low sorption capacity. Results demonstrated that most of contaminant inventories were rapidly released in the first pore volume of effluent, although a small portion of contaminants’ total mass exhibited time-dependent desorption. The calculated Kd values of CCl4 or CHCl3 partition were negligibly small. The transport behavior of both contaminants was similar and it was simulated well with a distributed (multiple)-rate (DR) statistical model, which accounted for the apparent contaminant mass transfer through diffusional pathways of different lengths, towards the advective pores. The distribution of contaminant mass between equilibrium and kinetic fractions, the distribution of the individual rate constants, and the average rate constants calculated with the parameters of the γ-distribution function (β and η) of the DR model, were sediments (texture) dependent, indicating that contaminant desorption during the late stage of leaching was driven by concentration gradients (i.e., diffusion) within sediment matrix porosity.

54 ENVIRONMENTAL SCIENCES↗

Public Health Response and Medical Management of Internal Contamination in Past Radiological or Nuclear Incidents: A Review

Following a radiological or nuclear emergency, workers, responders and the public may be internally contaminated with radionuclides. Screening, monitoring and assessing any internal contamination and providing necessary medical treatment, especially when a large number of individuals are involved, is challenging. Experience gained and lessons learned from the management of previous incidents would help to identify gaps in knowledge and capabilities on preparedness for and response to radiation emergencies. In this paper, eight largescale and five workplace radiological and nuclear incidents are reviewed cross 14 technical areas, under the broader topics of emergency preparedness, emergency response and recovery processes. The review findings suggest that 1) new strategies, algorithms and technologies are explored for rapid screening of large populations; 2) exposure assessment and dose estimation in emergency response and dose reconstruction in recovery process are supported by complementary sources of information, including ‘citizen science’; 3) surge capacity for monitoring and dose assessment is coordinated through national and international laboratory networks; 4) evidence-based guidelines for medical management and follow-up of internal contamination are urgently needed; 5) mechanisms for international and regional access to medical countermeasures are investigated and implemented; 6) long-term health and medical follow up programs are designed and justified; and 7) capabilities and capacity developed for emergency response are sustained through adequate resource allocation, routine nonemergency use of technical skills in regular exercises, training, and continuous improvement.

61 RADIATION PROTECTION AND DOSIMETRY↗

Thermophysical properties of low cost lithium nitrate salts produced in northern Chile for thermal energy storage

In recent years, lithium containing salts have been studied for thermal energy storage (TES) applications because of their excellent thermophysical properties. In solar power plants, lithium is seen as a way to improve the properties of state-of-the art molten salts used today. Lithium nitrate is a good candidate for sensible heat storage, because of its ability to increase the salt mixture's working temperature range. In the present research, thermophysical properties characterization of lithium nitrate containing salts, produced in Chile, have been carried out. Corrosion evaluations at 390° and 565 °C for 1000 h were performed for low chromium steel T22 and stainless steels (AISI 430 and AISI 316), respectively. Chemical composition of the salts including identification of corrosion products and impurities was determined and an estimation of the Chilean production costs is reported. The study shows a loss of thermal properties after the corrosion tests. The heat capacity was reduced, possibly caused by the formation of oxides at high temperatures. As a result, the partial thermal decomposition of the salt was probably produced by the incorporation of corrosion products from the steel.

25 ENERGY STORAGE↗

Power Law Growth and Delayed Feedbacks in Socio-Hydrological Systems

Water infrastructure dynamics result from coupled social and physical hydrological processes embedded in “socio-hydrological systems” (SHSs). Freshwater fuels socioeconomic activity, which in turn exerts pressure on water resources through increased water demand and water quality degradation. Many factors emphasize the need for quantitative tools to predict the future of these systems, including SHS failures due to growing water scarcity from population growth and climate change. However, unfolding the interactions between social and hydrological factors continues to resist theoretical treatment, impeding progress toward a predictive framework. To resolve this issue, we propose and evaluate time delays as surrogates for the social dynamics in SHS models. This approach permits the development of models that describe SHS dynamics in terms of observable, physical, hydrological state variables. We apply this approach to two case studies: (a) reservoir storage capacity growth in the world and the U.S. Water Resources Regions and (b) global water withdrawals. Substantial variability was identified in empirical estimates of growth rates and time delays. Reservoir construction typically follows a saturating, logistic curve with periodic, punctuated equilibria, separated by delays ranging from 5 to 20 years both globally and regionally. In contrast, global water withdrawal data display faster-than-exponential growth, characteristic of a positive feedback through which water use drives further water development. Historical analysis suggests that growth trends in water resources systems are superimposed by recurring periods of innovation and inactivity which are indicative of slow memory dissipation and delayed effects of past water use on current water infrastructure decisions.

54 ENVIRONMENTAL SCIENCES↗

An implantable instrument for studying the long-term flight biology of migratory birds

The design of an instrument deployed in a project studying the high altitude Himalayan migrations of bar-headed geese (Anser indicus) is described. The electronics of this archival datalogger measured 22 × 14 × 6.5 mm, weighed 3 g, was powered by a ½AA-sized battery weighing 10 g and housed in a transparent biocompatible tube sealed with titanium electrodes for electrocardiography (ECG). The combined weight of 32 g represented less than 2% of the typical bodyweight of the geese. The primary tasks of the instrument were to continuously record a digitised ECG signal for heart-rate determination and store 12-bit triaxial accelerations sampled at 100 Hz with 15% coverage over each 2 min period. Measurement of atmospheric pressure provided an indication of altitude and rate of ascent or descent during flight. Geomagnetic field readings allowed for latitude estimation. These parameters were logged twice per minute along with body temperature. Data were stored to a memory card of 8 GB capacity. Instruments were implanted in geese captured on Mongolian lakes during the breeding season when the birds are temporarily flightless due to moulting. The goal was to collect data over a ten month period, covering both southward and northward migrations. This imposed extreme constraints on the design's power consumption. Raw ECG can be post-processed to obtain heart-rate, allowing improved rejection of signal interference due to strenuous activity of locomotory muscles during flight. Accelerometry can be used to monitor wing-beat frequency and body kinematics, and since the geese continued to flap their wings continuously even during rather steep descents, act as a proxy for biomechanical power. The instrument enables detailed investigation of the challenges faced by the geese during these arduous migrations which typically involve flying at extreme altitudes through cold, low density air where oxygen availability is significantly reduced compared to sea level.

60 APPLIED LIFE SCIENCES↗

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN↗

FY-2015 Methyl Iodide Deep-Bed Adsorption Test Report

Nuclear fission produces fission and activation products, including iodine-129, which could evolve into used fuel reprocessing facility off-gas systems, and could require off-gas control to limit air emissions to levels within acceptable emission limits. Deep-bed methyl iodide adsorption testing has continued in Fiscal Year 2015 according to a multi-laboratory methyl iodide adsorption test plan. Updates to the deep-bed test system have also been performed to enable the inclusion of evaporated HNO 3 and increased NO 2 concentrations in future tests. This report summarizes the result of those activities. Test results showed that iodine adsorption from gaseous methyl iodide using reduced silver zeolite (AgZ) resulted in initial iodine decontamination factors (DFs, ratios of uncontrolled and controlled total iodine levels) under 1,000 for the conditions of the long-duration test performed this year (45 ppm CH3I, 1,000 ppm each NO and NO 2 , very low H 2 O levels [3 ppm] in balance air). The mass transfer zone depth exceeded the cumulative 5-inch depth of 4 bed segments, which is deeper than the 2-4 inch depth estimated for the mass transfer zone for adsorbing I 2 using AgZ in prior deep-bed tests. The maximum iodine adsorption capacity for the AgZ under the conditions of this test was 6.2% (6.2 g adsorbed I per 100 g sorbent). The maximum Ag utilization was 51%. Additional deep-bed testing and analyses are recommended to (a) expand the data base for methyl iodide adsorption and (b) provide more data for evaluating organic iodide reactions and reaction byproducts for different potential adsorption conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NETL Gen-2 Oxygen Carrier Assessment

The National Energy Technology Laboratory’s (NETL) Research and Innovation Center (RIC) has been conducting laboratory-scale tests to develop a new chemical looping combustion (CLC) oxygen carrier (OC) having copper, iron, and alumina components. This OC, designated as the Gen-2 OC throughout this report, has high maximum oxygen capacity and has been tested extensively in the RIC methane-fueled chemical looping reforming. A screening analysis has been conducted to estimate the performance and cost of CLC when utilizing the Gen-2 OC. In this report, the performance and cost results are compared to those of a range of previously assessed CLC OCs to provide a basis to establish the relative merits and issues associated with the Gen-2 OC. Base load CLC power plants utilizing the Gen-2 OC and the three comparison OCs considered in this assessment (Fe 2 O 3- , CuO-, CaSO 4- based) are estimated to have thermal efficiency and cost of electricity (COE) characteristics potentially superior to those of the equivalent conventional pulverized coal (PC) power plant applying conventional, amine-based CO 2 capture technology. The current assessment does not address flexible plant operation. An evaluation of the CLC plant designed for flexible operation would need to include a comparable PC plant designed for flexible operation.

01 COAL, LIGNITE, AND PEAT↗

Divergent predictions of carbon storage between two global land models: Attribution of the causes through traceability analysis

Representations of the terrestrial carbon cycle in land models are becoming increasingly complex. It is crucial to develop approaches for critical assessment of the complex model properties in order to understand key factors contributing to models' performance. In this study, we applied a traceability analysis which decomposes carbon cycle models into traceable components, for two global land models (CABLE and CLM-CASA') to diagnose the causes of their differences in simulating ecosystem carbon storage capacity. Driven with similar forcing data, CLM-CASA' predicted – 31 % larger carbon storage capacity than CABLE. Since ecosystem carbon storage capacity is a product of net primary productivity (NPP) and ecosystem residence time ( τ E ), the predicted difference in the storage capacity between the two models results from differences in either NPP or τ E or both. Our analysis showed that CLM-CASA'simulated 37 % higher NPP than CABLE. On the other hand, τ E , which was a function of the baseline carbon residence time ( τ ' E ) and environmental effect on carbon residence time, was on average 11 years longer in CABLE than CLM-CASA'. This difference in τ E was mainly caused by longer τ ' E of woody biomass (23 vs. 14 years in CLM-CASA'), and higher proportion of NPP allocated to woody biomass (23 vs. 16 %). Differences in environmental effects on carbon residence times had smaller influences on differences in ecosystem carbon storage capacities compared to differences in NPP and τ ' E . Altogether, the traceability analysis showed that the major causes of different carbon storage estimations were found to be parameters setting related to carbon input and baseline carbon residence times between two models.

54 ENVIRONMENTAL SCIENCES↗

Favorable tectonic and structural settings of geothermal systems in the Great Basin region, western USA: Proxies for discovering blind geothermal systems

We recently completed a comprehensive inventory of the structural settings of known geothermal systems (426 total, ≥37°C) in the extensional to transtensional terrane of the Great Basin region in the western USA. Of the known systems, ~39% are blind (no surface hot springs or fumaroles), but estimates suggest that as much as 75% of the geothermal resources in the region are blind. The density of geothermal systems and capacity of power plants correlate generally with tectonic strain rates. However, highenthalpy geothermal activity is restricted to regions of extensional to transtensional strain, particularly the northwestern part of the Great Basin directly northeast of the dextral shear zone of the Walker Lane and pull-apart zones within both the Walker Lane and San Andreas fault system. We catalogued systems into eight major groups, based on the dominant pattern of faulting. Of the nearly 250 categorized geothermal fields, we found that step-overs or relay ramps in normal fault zones are the most favorable setting, hosting ~32% of the systems. Such areas are characterized by multiple, commonly overlapping fault strands, increased fracture density, and thus enhanced permeability. Other common settings include a) normal fault terminations (25%), where horse-tailing generates a myriad of closely-spaced faults and thus increased permeability; and b) fault intersections between two normal faults or between normal faults and transverse oblique-slip faults (22%), where multiple minor faults typically connect major structures and fluids can flow readily through highly fractured, dilational quadrants. Less common settings include: a) accommodation zones (9%); b) displacement transfer zones (5%); c) pull-aparts in strike-slip faults (3%); d) bends in normal faults (2%); and e) major range-front normal faults (1%). Pull-aparts and displacement transfer zones are more abundant in the transtensional western part of the Great Basin. Quaternary faults typically lie within or near most of the geothermal systems. Geothermal systems are rare along major range-front faults, possibly due to both reduced permeability in thick zones of clay gouge and periodic release of stress in major earthquakes. Step-overs, terminations, intersections, and accommodation zones correspond to long-term, critically stressed areas, where fluid pathways would more likely remain open in networks of closely-spaced, breccia-dominated fractures. Notably, many higher enthalpy systems are hybrids and contain more than one type of favorable setting (e.g. fault intersection within broad accommodation zone). These data can guide exploration strategies, especially for blind or hidden systems.

15 GEOTHERMAL ENERGY↗

Optimization of Energy Storage System Economics and Controls by Incorporating Battery Degradation Costs in REopt

The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.

battery↗

Renewable electricity capacity planning with uncertainty at multiple scales

Abstract We formulate and compare optimization models of investment in renewable generation using a suite of social planning models that compute optimal generation capacity investments for a hydro-dominated electricity system where inflow uncertainty results in a risk of energy shortage. The models optimize the expected cost of capacity expansion and operation allowing for investments in hydro, geothermal, solar, wind, and thermal plant, as well as battery storage for smoothing load profiles. A novel feature is the integration of uncertain seasonal hydroelectric energy supply and short-term variability in renewable supply in a two-stage stochastic programming framework. The models are applied to data from the New Zealand electricity system and used to estimate the costs of moving to a 100% renewable electricity system by 2035. We also explore the outcomes obtained when applying different forms of CO 2 constraint that limit respectively non-renewable capacity, non-renewable generation, and CO 2 emissions on average, almost surely, or in a chance-constrained setting, and show how our models can be used to investigate the merits of a proposed pumped-hydro scheme in New Zealand’s South Island.

Ferris, Michael C.↗

Comprehensive Assessment of On-And Off-Board Vehicle-To-Grid Technology Performance and Impacts on Battery and the Grid

This project defined, developed, and tested the open standards-based requirements, engineering design and system integration of on and off-vehicle Vehicle-to-Grid technologies both on the grid and on the PEV, to assess their effectiveness in implementing the use cases that create value for the grid, which in turn, can be passed on to the ratepayers and the PEV owners. The project comprised of three key categories of work and four key sub-areas of work. The three key categories were: On-Vehicle V2G, Off-Vehicle V2G, and impact of V2G operation on the battery capacity degradation. The four key sub-areas of work under each of these categories were: defining requirements, implementing the technology, performing system integration testing, and estimating the value of each of the grid services under specific assumptions, on a per-vehicle and on an aggregated basis. The technical implementation demonstrated the validity of standards-based approach to grid integration that led to interoperability, in addition to assessing the operational details with grid constraints imposed at the transformer level. The technology implementation also identified the subtle gaps in the standards definition to close the feedback loop on the accuracy of the standards as written, which are being implemented as revisions to the appropriate protocols. The battery impacts assessment developed a test cycle that the batteries from a real PHEV were subjected to for both the mobility-only and mobility with V2G specific energy cycling. While the battery impact results show a clear incremental degradation in response to additional throughput for V2G application purposes, the amount of additional kWh that can be made available without exceeding the end-of-life capacity definition of the battery at its 10-year warranty period was found to be significant. Given that the PEV battery being exercised during testing was a PHEV battery (smaller energy capacity), and 44% of its usable energy (i.e., SOC) was utilized daily for V2G applications, the EVs with much larger batteries will fare much better, either in terms of extracting more value in terms of incremental kWh for V2G, or in terms of relative incremental degradation of the capacity through the battery lifespan. Further, this battery was the second-generation Lithium-Ion chemistry circa 2015, which is at least two generations ago. Continual improvements in electrochemistry and manufacturing techniques as well as on-board capacity will enable the future batteries to provide even more energy for non-mobility-related services. Finally, the valuation of V2G energy services at the premise, distribution, and the ISO/market level was carried out for both the on-vehicle and off-vehicle cases, to understand both the GHG mitigation and operational efficiency improvements in quantitative terms. The analysis indicates that between $\$400$ and $\$1400$ per year of total value to the grid can be realized. When netted of costs to implement V2G either on or off-vehicle, the net value is available to be shared between the ratepayers and the EV owners. Over the life of the EV, therefore, this value becomes significant and can easily provide both ratepayer and EV owner benefits more than the cost of the equipment, either on or off-board, in addition to providing GHG mitigation benefits both on the grid and on the mobility sides. For these benefits to accrue, the key learnings from both the on- and off-vehicle V2G parts of the project indicate the need for at-scale demonstrations through involvement of real EV owners to validate both the technical feasibility, interoperability, as well as real grid benefits by performing extensive data collection and analysis. This will help inform the grid planners, the program designs, and tariff designers, as well as automotive and equipment manufacturers how best to create their products to maximize grid, ratepayer, and EV owner value.

30 DIRECT ENERGY CONVERSION↗

Application of the Aquifer Impact Model to support decisions at a CO 2 sequestration site

The National Risk Assessment Partnership (NRAP) has developed a suite of tools to assess and manage risk at CO 2 sequestration sites. The NRAP tool suite includes the Aquifer Impact Model (AIM), which evaluates the potential for groundwater impacts from leaks of CO 2 and brine through abandoned wellbores. There are two aquifer reduced-order models (ROMs) included with the AIM tool, a confined alluvium aquifer, and an unconfined carbonate aquifer. The models accept aquifer parameters as a range of variable inputs so they may have broad applicability. The generic aquifer models may be used at the early stages of site selection, when site-specific data is not available. Guidelines have been developed for determining when the generic ROMs might be applicable to a new site. This work considers the application of the AIM to predicting the impact of CO 2 or brine leakage were it to occur at the Illinois Basin Decatur Project (IBDP). Results of the model sensitivity analysis can help guide characterization efforts; the hydraulic parameters and leakage source term magnitude are more sensitive than clay fraction or cation exchange capacity. Sand permeability was the only hydraulic parameter measured at the IBDP site. More information on the other hydraulic parameters could reduce uncertainty in risk estimates. Some non-adjustable parameters are significantly different for the ROM than for the observations at the IBDP site. The generic ROMs could be made more useful to a wider range of sites if the initial conditions and no-impact threshold values were adjustable parameters.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

FC-PLACER (Fuel Cell Plant Layout and Cost Estimation Resource) [SWR-26-027]

The Fuel Cell Plant Layout and Cost Estimation Resource (FC-PLACER) is a tool to perform a footprint and cost analysis for hydrogen fuel cell based power plants. This analysis tool provides a comprehensive design and cost assessment for a 100-MW stationary PEM fuel cell power plant, utilizing specifications from commercially available PEM fuel cell modules originally designed for heavy-duty vehicle applications. Additionally, the tool offers flexibility, enabling adaptation to various capacity requirements or plant configurations and facilitating the evaluation of system layout and overnight costs. In particular, it includes a detailed accounting of balance of plant material and labor costs and enables a precise estimate of plant spatial footprint.

Reznicek, Evan [National Laboratory of the Rockies↗