Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

Measurement and Analysis of the Extreme Physical Shock Environment Experienced by Crane-Mounted Radiation Detection Systems

At ports of entry, radiation detectors could be mounted on container gantry crane spreaders to monitor cargo containers entering and leaving the country. These detectors would have to withstand the extreme physical conditions experienced by these spreaders during normal operations. Physical shock data from the gable ends of a spreader were recorded during the loading and unloading of a cargo ship by twohard mounted PCB Piezotronics model 340A50 accelerometers and two Lansmont SAVER 9X30 units(with padding). The majority of large shocks were observed in the vertical direction. The Lansmont units recorded mean shocks of 22.215 ±1.174and 23.776 ±1.140g, while the PCB accelerometers recorded mean shocks of 31.608 ±1.798and 37.072 ±2.015g in this direction. Maximum shocks were as high as 118.854 g. A scatter plot of observed peak acceleration versus velocity change is presented to allow comparison with the damage boundary curve for any planned instrumentation for future systems. Furthermore, it is hoped that the results of this research will aid in the design of future crane-mounted systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Probing Flavor Asymmetry of Anti-quarks in the Proton by Drell-Yan Experiment SeaQuest

A new measurement on the avor asymmetry between d and u in the proton is reported in this thesis. The proton contains a substantial number of antiquarks which arise from dynamical interactions of gluons such as gluon dissociation to a quark-antiquark pair, g ! q + q, and from non-perturbative processes as described by the pion-cloud model, for example. The antiquarks in the proton undertake an important role in determining the dynamic characteristics of the internal structure of the proton, although its distribution in the proton and its origin are not fully understood. Understanding sea quarks in hadron is an important subject for QCD. The SeaQuest experiment at Fermi National Accelerator Laboratory (Fermilab) is a xed target experiment using the 120 GeV proton beam extracted from the Fermilab Main Injector. One of the goals of the experiment is to measure the avor asymmetry between d quark and u quark in the proton as a function of the target Bjorken x using the Drell-Yan process in the p-p or p-d reactions. This process takes place in hadron-hadron collisions when a quark in one hadron in the beam and an antiquark in other hadron in the target annihilate into a virtual photon that decays into a lepton pair. The avor asymmetry between d and u quarks was found by deep-inelastic scattering experiment NMC at CERN. The E866/NuSea experiment at Fermilab obtained the avor asymmetry in the proton for 0:015 < x < 0:35 using the 800 GeV proton beam extracted from the Fermilab Tevatron. The result indicates the dominance of d; it is 70% larger than u at lower x. The SeaQuest experiment was planned to do a new precise measurement at higher x region. The lower energy beam (120 GeV) increases the Drell-Yan cross section and suppresses the background primarily arising from J/ decays. Therefore, SeaQuest will obtain more statistics in a shorter time than the E866 experiment. After detector construction, detector commissioning and accelerator upgrade, physics data taking started in 2013. The SeaQuest spectrometer is designed to detect dimuon from the Drell-Yan process. It consists of targets, two di-pole magnets, and four tracking detector groups. The third tracking detector group has two drift chambers. One was newly fabricated in Japan by the Japanese group in SeaQuest collaboration and was shipped to Fermilab. The other one was constructed by SeaQuest collaborator in Fermilab under the initiative of the Japanese group. I worked on the construction and installation of the detectors, data taking and data analysis in SeaQuest. I extracted the avor asymmetry as a function of Bjorken x using the SeaQuest data for the rst time. This thesis shows the results using a part of data taken in 2014 and 2015. The asymmetry was extracted for much wider Bjorken x region than the previous experiment. The measured Bjorken x range covers up to 0.58. The result shows that the ratio of d=u is always higher than 1 at 0:1 < x < 0:45, in contrast to the E866 result. For 0:45 < x < 0:58, the result shows that the ratio is close to unity. Predictions made by current PDF parameterizations are in agreement with the present result. Also, a prediction obtained by one of the non-perturbative models, pion-cloud model, is closer to the SeaQuest result than the E866 result. This result of d=u asymmetry at the wide Bjorken x region, 0:1 < x < 0:58, is very important information to understand the inner structure of the proton and the origin of the sea quarks in the proton.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proceedings of RIKEN BNL Research Center Workshop: Jet Observables at the Electron-Ion Collider (Volume 136) [Slides]

As the realization of an Electron Ion Collider (EIC) moves forward, efforts from the nuclear physics community continue to grow. In addition to the ongoing detector R&D efforts, plans for novel analysis topics must be demonstrated to aid in the detector designs, so that we can maximize the physics output of the EIC. This relies on input from both the experimental and theory communities. The aim of this workshop is to gather experts as well as those with a developing interest in the EIC so that theorists and experimentalists with experience measuring jets in a variety of hadronic collision systems can discuss the possible advantages and challenges of making measurements of jets in e+p and for the first time ever jets in e+A collisions at the EIC. In the time since the EIC white paper was written in 2011, there has been a growing recognition that jet observables could be a powerful probe of many of the physics topics which will be addressed by the EIC. Recent years have seen a multitude of both theoretical and experimental papers exploring the utility of jets for topics as diverse as determining the hadronic structure of photons, studying the 3D structure of the nucleon, and characterizing the properties of the matter found in nuclei. The aim of this workshop is to provide a forum for both theorists and experimentalists to discuss the possible advantages and challenges of jet measurements in e+p and e+A collisions at the EIC, learn about the status of necessary simulation tools, consider requirements on detector performance, and propose new ideas for jet observables and measurements. This proceedings report is a compilation of slides from the presentations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenic Detector Development for SuperCDMS

The dark matter (DM) problem is currently one of the most pressing issues facing physics. This thesis presents some of my work and contributions to the detectors employed by the Super Cryogenic Dark Matter Search (SuperCDMS), one of the many experiments currently investigating DM. First, we present an overview of astrophysical and cosmological observations to give insight into our current understanding of DM and its role in the universe. Some potential particle DM candidates are also discussed. Then we describe the SuperCDMS experiment and relevant detector technologies. We go into particular detail in discussing the phonon sensors, deriving the relationships that define their fundamental working principles and describing their practical deployment. We also discuss the main noise contributions to the phonon sensors which can limit experimental sensitivity. We then present some work related to reconstruction of event position in the detectors, including new analysis techniques and a n ovel cryogenic calibration source mover we have developed and tested. We also present tests of improving experimental scalability by increasing individual detector masses using the largest-diameter cryogenic Si detectors yet operated. We present first experimental results from the novel use of $(n,\gamma)$ processes to calibrate the low energy nuclear recoil energy scale. This work is essential to understand how DM-nuclear interactions will manifest in semiconductor detectors. We also take a short look at the newest, most sensitive detectors currently operated by SuperCDMS and discuss how they are allowing new insights into critical physics processes in all SuperCDMS detectors. Finally, we demonstrate how some of the various improvements discussed in this work can improve the experimental reach of the next generation of SuperCDMS at SNOLAB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification of low-momentum muons in the CMS detector using multivariate techniques in proton-proton collisions at $\sqrt{s}$ = 13.6 TeV

“Soft” muons with a transverse momentum below 10 GeV are featured in many processes studied by the CMS experiment, such as decays of heavy-flavor hadrons or rare tau lepton decays. Maximizing the selection efficiency for these muons, while simultaneously suppressing backgrounds from long-lived light-flavor hadron decays, is therefore important for the success of the CMS physics program. Multivariate techniques have been shown to deliver better muon identification performance than traditional selection techniques. To take full advantage of the large data set currently being collected during Run 3 of the CERN LHC, a new multivariate classifier based on a gradient-boosted decision tree has been developed. It offers a significantly improved separation of signal and background muons compared to a similar classifier used for the analysis of the Run 2 data. The performance of the new classifier is evaluated on a data set collected with the CMS detector in 2022 and 2023, corresponding to an integrated luminosity of 62 fb -1 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HEP Software Foundation Community White Paper Working Group – Visualization

In modern High Energy Physics (HEP) experiments visualization of experimental data has a key role in many activities and tasks across the whole data chain: from detector development to monitoring, from event generation to reconstruction of physics objects, from detector simulation to data analysis, and all the way to outreach and education. In this paper, the definition, status, and evolution of data visualization for HEP experiments will be presented. Suggestions for the upgrade of data visualization tools and techniques in current experiments will be outlined, along with guidelines for future experiments. This paper expands on the summary content published in the HSF \emph{Roadmap} Community White Paper~\cite{HSF-CWP-2017-01}

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Consistency test of neutrinoless double beta decay with one isotope

We discuss a consistency test which makes it possible to discriminate unknown nuclear background lines from neutrinoless double beta decay with only one isotope. By considering both the transition to the ground state and to the first excited 0{sup +} state, a sufficiently large detector can reveal if neutrinoless double beta decay or some other nuclear physics process is at work. Such a detector could therefore simultaneously provide a consistency test for a certain range of Majorana masses and be sensitive to lower values of the effective Majorana mass <m{sub {nu}}{sub e}>.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Aspects of Higgs Physics at a $\sqrt{s}=3$ TeV Muon Collider with detailed detector simulation

The Muon Collider is one of the most promising future collider facilities with the potential to reach multi-TeV center-of-mass energy and high luminosity. Due to the significant Higgs boson production cross section in muon-antimuon collisions at such high energies, the collider offers an excellent opportunity for in-depth exploration of Higgs boson properties. It holds the capability to significantly advance our understanding of the Higgs sector to a very high level of precision. However, the presence of beam-induced background resulting from the decay of the beam muons poses unique challenges for detector development and event reconstruction. In this paper, the prospects for measuring various Higgs boson properties at a center-of-mass energy of 3 TeV are presented, using a detailed detector simulation in a realistic environment. The study demonstrates the feasibility of achieving high precision results with the current state-of-the-art detector design. In addition, the paper discusses the detector requirements necessary to achieve this level of accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Future Advances in Photon-Based Neutrino Detectors: A SNOWMASS White Paper

We discuss here new, enabling technologies for future photon-based neutrino detectors. These technologies touch nearly every aspect of such detectors: new scintillating materials, new methods of loading isotopes, new photon sensors and collectors, new approaches to simulation and analysis, and new front-end electronics and DAQ ideas. Of particular interest are technologies that enable broad physics programs in hybrid Cherenkov/scintillation detectors, such as slow fluors, water-based liquid scintillator, and spectral sorting of photons. Several new large-scale detector ideas are also discussed, including hybrid detectors like Theia, ArTEMIS, and generic slow-fluor detectors, as well as the very different SLIPs and LiquidO approaches to instrumenting photon-based detectors. A program of demonstrators for future detectors, including ANNIE, Eos, and NuDOT are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise mapping of the magnetic field in the CMS barrel yoke using cosmic rays

The CMS detector is designed around a large 4 T superconducting solenoid, enclosed in a 12000-tonne steel return yoke. A detailed map of the magnetic field is required for the accurate simulation and reconstruction of physics events in the CMS detector, not only in the inner tracking region inside the solenoid but also in the large and complex structure of the steel yoke, which is instrumented with muon chambers. Using a large sample of cosmic muon events collected by CMS in 2008, the field in the steel of the barrel yoke has been determined with a precision of 3 to 8% depending on the location.

Chatrchyan, S.↗

Optoelectronic Picosecond Detection of Synchrotron X-rays

The goal of this research program was to develop a detector that would measure x-ray time profiles with picosecond resolution. This was specifically aimed for use at x-ray synchrotrons, where x-ray pulse profiles have Gaussian time spreads of 50-100 ps (FWHM), so the successful development of such a detector with picosecond resolution would permit x-ray synchrotron studies to break through the pulse width barrier. That is, synchrotron time-resolved studies are currently limited to pump-probe studies that cannot reveal dynamics faster than ~50 ps, whereas the proposed detector would push this into the physically important 1 ps domain. The results of this research effort, described in detail below, are twofold: 1) the original plan to rely on converting electronic signals from a semiconductor sensor into an optical signal proved to be insufficient for generating signals with the necessary time resolution and sensitivity to be widely applicable; and 2) an all-optical method was discovered whereby the x-rays are directly absorbed in an optoelectronic material, lithium tantalate, which can then be probed by laser pulses with the desired picosecond sensitivity for detection of synchrotron x-rays. This research program has also produced new fundamental understanding of the interaction of x-rays and optical lasers in materials that has now created a viable path for true picosecond detection of synchrotron x-rays.

36 MATERIALS SCIENCE↗

Characterization of Low Gain Avalanche Detector Prototypes’ Response to Gamma Radiation

Motivated by the need for fast timing detectors to withstand up to 2 MGy of ionizing dose at the High Luminosity Large Hadron Collider, prototype low gain avalanche detectors (LGADs) have been fabricated in a single pad configuration, 2 × 2 arrays, and related p-i-n diodes, and exposed to Co-60 sources for study. Devices were fabricated with a range of dopant layer concentrations, and for the arrays, a variety of inter-pad distances and distances from the active area to the edge. Measurements of capacitance versus voltage and leakage current versus voltage have been made to compare pre- and post-irradiation characteristics in gain layer depletion voltage, full bulk depletion voltage, and breakdown voltage. Conclusions are drawn regarding the effects of the gammas on both surface and interface states and on their contribution to acceptor removal through non-ionizing energy loss from Compton electrons or photoelectrons. Comparison of the performances of members of the set of devices can be used to optimize gain layer parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extreme argon purity in a large, non-evacuated cryostat

Liquid Argon Time Projection Chambers (LArTPCs) show promise as scalable devices for the large detectors needed for long-baseline neutrino oscillation physics. Over the last several years at Fermilab a staged approach to developing the technology for large detectors has been developed. The TPC detectors require ultra-pure liquid argon with respect to electronegative contaminants such as oxygen and water. The tolerable electronegative contamination level may be as pure as 60 parts per trillion of oxygen. Three liquid argon cryostats operated at Fermilab have achieved the extreme purity required by TPCs. These three cryostats used evacuation to remove atmospheric contaminants as the first purification step prior to filling with liquid argon. Future physics experiments may require very large detectors with tens of kilotonnes of liquid argon mass. The capability to evacuate such large cryostats adds significant cost to the cryostat itself in addition to the cost of a large scale vacuum pumping system. This paper describes a 30 ton liquid argon cryostat at Fermilab which uses purging to remove atmospheric contaminants instead of evacuation as the first purification step. This cryostat has achieved electronegative contamination levels better than 60 parts per trillion of oxygen equivalent. The results of this liquid argon purity demonstration will strongly influence the design of future TPC cryostats.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recoil imaging for dark matter, neutrinos, and physics beyond the Standard Model

Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin Physics Capability with Silicon Vertex Tracker for PHENIX

The PHENIX detector is being upgraded with a silicon vertex tracker (VTX) to enhance physics capability both in spin physics and heavy ion physics. In order to check the performance of the VTX, PYTHIA simulation was performed with gamma-jet production events under the condition of center-of-mass energy of 500 GeV and the integrated luminosity of 300 pb{sup -1}. We will report the simulation results of a longitudinal double-spin asymmetry A{sub LL} with the VTX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for scalar top and bottom quarks at the Tevatron

This document reviews recent results on the search for scalar top and scalar bottom quarks in p{bar p} collisions at {radical}s = 1.96 TeV. The analyses presented are based on data samples with integrated luminosities from 1.0 to 1.9 fb{sup -1} recorded at the Tevatron with the D0 and CDF detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗