Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design of experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Testing of materials for passive thermal control of space suits

An effort is underway to determine the coating material of choice for the AX-5 prototype hard space suit. Samples of 6061 aluminum have been coated with one of 10 selected metal coatings, and subjected to corrosion, abrasion, and thermal testing. Changes in reflectance after exposure are documented. Plated gold exhibited minimal degradation of optical properties. A computer model is used in evaluating coating thermal performance in the EVA environment. The model is verified with an experiment designed to measure the heat transfer characteristics of coated space suit parts in a thermal vacuum chamber. Details of this experiment are presented.

Squire, Bernadette↗

Carbonate formation on Mars: History of the CO2 atmosphere from models of diffusion-limited growth in non-aqueous environments

We conducted preliminary experiments designed to measure the amount of CO2 reacted from a simulated Martian atmosphere to form carbonate on silicate grains. Warm experiments at constant T (300-350 K) and with no water (vapor or liquid) yielded no detectable reaction, suggesting the following result. If we are indeed operating in the thermodynamically-favorable regime (supported by Gooding (1978) for the gas-solid reaction), then the lack of a reaction at warm temperatures suggests that a reaction in the 200-300 K regime will be less favored if reaction kinetics dominate. The completely dry scenario is thus not favored. An additional experiment, with abundant water vapor and at T approx. 300 K (constant), yielded a negative result as well. However, this is not inconsistent with Booth's findings, since lower temperatures may be required for the absorption of a monolayer of water. We plan further (lower-T) experiments.

Stephens, Stuart K.↗

STS-85 Day 10 Highlights

On this tenth day of the STS-85 mission, the flight crew, Cmdr. Curtis L. Brown, Jr., Pilot Kent V. Rominger, Payload Cmdr. N. Jan Davis (Ph.D.), Mission Specialists Robert L. Curbeam, Jr. and Stephen K. Robinson (Ph.D.), and Payload Specialist Bjarni V. Tryggvason watch over an experiment designed to study how cooling systems operate in space. With operating problems resolved on the Two-Phase Fluid Loop Experiment, or TPFLEX (teepee flex), investigators expect to get all the data planned for the mission. Robinson later assisted, where necessary, with the CRISTA-SPAS rendezvous activities.

Source record↗

Dynamic Dust Accumulation and Dust Removal Observed on the Mars Exploration Rover Magnets

The Mars Exploration Rovers each carry a set of Magnetic Properties Experiments designed to investigate the properties of the airborne dust in the Martian atmosphere. It is a preferred interpretation of previous experiments that the airborne dust in the Martian atmosphere is primarily composed by composite silicate particles containing one or more highly magnetic minerals as a minor constituent. The ultimate goal of the magnetic properties experiments on the Mars Exploration Rover mission is to provide some information/ constraints on whether the dust is formed by volcanic, meteoritic, aqueous, or other processes. The first problem is to identify the magnetic mineral(s) in the airborne dust on Mars. While the overall results of the magnetic properties experiments are presented in, this abstract will focus on dust deposition and dust removal on some of the magnets.

Bertelsen, P.↗

Experimental Simulations of Lunar Magma Ocean Crystallization: The Plot (But Not the Crust) Thickens

Numerical models of differentiation of a global-scale lunar magma ocean (LMO) have raised as many questions as they have answered. Recent orbital missions and sample studies have provided new context for a large range of lithologies, from the comparatively magnesian "purest anorthosite" reported by to Si-rich domes and spinel-rich clasts with widespread areal distributions. In addition, the GRAIL mission provided strong constraints on lunar crustal density and average thickness. Can this increasingly complex geology be accounted for via the formation and evolution of the LMO? We have in recent years been conducting extensive sets of petrologic experiments designed to fully simulate LMO crystallization, which had not been attempted previously. Here we review the key results from these experiments, which show that LMO differentiation is more complex than initial models suggested. Several important features expected from LMO crystallization models have yet to be reproduced experimentally; combined modelling and experimental work by our group is ongoing.

Draper, D. S.↗

Discovering New Light States at Neutrino Experiments

Experiments designed to measure neutrino oscillations also provide major opportunities for discovering very weakly coupled states. In order to produce neutrinos, experiments such as LSND collide thousands of Coulombs of protons into fixed targets, while MINOS and MiniBooNE also focus and then dump beams of muons. The neutrino detectors beyond these beam dumps are therefore an excellent arena in which to look for long-lived pseudoscalars or for vector bosons that kinetically mix with the photon. We show that these experiments have significant sensitivity beyond previous beam dumps, and are able to partially close the gap between laboratory experiments and supernovae constraints on pseudoscalars. Future upgrades to the NuMI beamline and Project X will lead to even greater opportunities for discovery. We also discuss thin target experiments with muon beams, such as those available in COMPASS, and show that they constitute a powerful probe for leptophilic PNGBs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal Model for Horizontal In-Water and In-Air Mini-Plate Experiments in the Advanced Test Reactor

Mini-Plate (MP) irradiation tests are a fueled experiment designed for irradiation in multiple test locations in the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). MP experiments are considered a non-instrumented drop-in test where small aluminum-clad fuel plate samples are cooled directly by the ATR Primary Coolant System (PCS) water. These fueled experiments contain aluminum-clad fuel mini plates consisting of monolithic U-10Mo. Previous thermal analyses have been documented concerning oxide growth[1] and thermal safety margin[2] for the MP-2 experiment. A thermal analysis has been performed on the MP-2 experiment using a new technique for calculating the necessary time after the experiment has been irradiated and reactor shutdown necessary to not exceed the 95% lower bound blister threshold temperature for the fuel in a horizontal in air configuration. A horizontal in water model has also been analyzed and will be discussed. After the experiment is irradiated in the ATR, it is necessary to calculate the fuel meat temperatures at 12 hours after shutdown. This is done to assure that at the 12 hour mark, if this experiment is removed from the reactor and accidentally dropped onto the working tray and is in the most severe geometrical configuration of horizontal (minimum heat transfer) that fission products will not be released. The blister threshold temperature is considered this safety limit. The horizontal in air analysis is also performed considering that the experiment is horizontal in a drained canal and filled with air and natural convection heat transfer with air on the outside. The initial mini-plate testing campaign known as MP-1 [3] has been irradiated and its purpose was to form the base fuel specimens fabricated by various processes so that a single process can be down-selected for qualification. MP-2 will then serve to populate a comprehensive fuel performance data set for the down-selected fabrication process. The MP-2 experiment will be irradiated in several locations of the ATR as shown in Figure 1. The fuel plate thickness and geometry is identical to the MP-1 experiment [3], with the only variable being the fuel meat thickness. This model of the B-12 position is treated as encompassing the I-21, I-24, and B-9 positions since it has more fuel and higher total heat than the other positions. Since the blister threshold temperature is a function of fission density, a series of fission densities is calculated for the B-12 position to cover the other three positions. The B 12 position specifically uses fuel meat that is 0.016 in thick by 3.25 in long and 0.75 in tall. The total plate thickness is 0.050 in. Aluminum cladding forms the barrier between the PCS and the fuel meat. The purpose of this paper is to demonstrate this new technique developed to calculate the necessary decay time after shutdown for a series of fission densities using the ABAQUS [4] finite element and heat transfer code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid Surface Combustion Experiment Completes a Series of Eight Successful Flights

The Solid Surface Combustion Experiment (SSCE) was the first combustion experiment to fly in the space shuttle and the first such experiment in the NASA spaceflight program since Skylab. SSCE was actually a series of experiments designed to begin to characterize flame spreading over solid fuels in microgravity and the differences of this flame spreading from normal gravity behavior. These experiments should lead to a better understanding of the physical processes involved--increasing our understanding of fire behavior, both in space and on Earth. SSCE results will help researchers evaluate spacecraft fire hazards. These experiments were conceived by the principal investigator, Professor Robert A. Altenkirch, Dean of Engineering at Washington State University. In the first five flights, the fuel sample--ashless filter paper instrumented with three thermocouples--was mounted in a sealed chamber filled with a 50-percent or 35-percent mixture of oxygen in nitrogen at pressures of 1.0, 1.5, and 2.0 atm. In the next three flights, a polymethyl methacrylate (plexiglass) fuel was instrumented with three thermocouples and tested in a 70-percent or 50-percent mixture of oxygen and nitrogen at pressures of 1.0 and 2.0 atm. SSCE is a self-contained, battery-operated experiment that can be flown either in the shuttle middeck or in the Spacelab module. More information about the hardware configuration have been published. This past year, the final two of eight flights were completed on STS-64 and STS-63. The NASA Lewis Research Center designed and built the SSCE payload and performed engineering, testing, scientific, and flight operations support. The SSCE project was supported in some way by nearly every major sector of Lewis' organization. Professor Altenkirch developed a numerical simulation of the flame-spreading process from first principles (of fluid mechanics, heat transfer, and reaction kinetics). The spread rates, flame shape, and thermodynamic data from the SSCE flights are being compared directly with the results of the computational model. Results from the eight flights will be used to formulate an improved solid-phase pyrolysis model. In addition, some results of the flights have been published and presented at international combustion symposiums. Additional solid fuel combustion experiments are being investigated for future tests with the existing hardware.

Source record↗

ACCESS: Design and Sub-System Performance

Establishing improved spectrophotometric standards is important for a broad range of missions and is relevant to many astrophysical problems. ACCESS, "Absolute Color Calibration Experiment for Standard Stars", is a series of rocket-borne sub-orbital missions and ground-based experiments designed to enable improvements in the precision of the astrophysical flux scale through the transfer of absolute laboratory detector standards from the National Institute of Standards and Technology (NIST) to a network of stellar standards with a calibration accuracy of 1% and a spectral resolving power of 500 across the 0.35 -1.7 micrometer bandpass.

Kaiser, Mary Elizabeth↗

Design of the MESUR/pathfinder microrover

The use of unmanned robotic vehicles to assist in the exploration of Mars and other planets has been of interest to the National Aeronautics and Space Administration (NASA) for several decades and has been the focus of an ongoing research program at the Jet Propulsion Laboratory (JPL) for a similar period of time. As a result of these research activities, JPL is in the process of designing and building a small (7-9 kg) microrover to be flown aboard the Mars Environmental Survey Mission (MESUR)/Pathfinder spacecraft, which is tentatively to be launched to Mars in late 1997. The microrover will perform a variety of technology experiments designed to provide information critical to the design of future planetary rovers. In addition, the microrover will perform several science and lander related experiments using specialized onboard instruments. To enable the microrover to perform these experiments at selected target areas and at the same time deal with the long time delays (and limited communications bandwidth), a control/navigation approach combining the use of operator-designated waypoints and onboard behavior control has been adopted. The design of the MESUR/Pathfinder microrover and the overall manner in which it is controlled are described herein.

Stone, Henry W.↗

The importance of independent replication of treatments in plant science

Among other foci, the Journal of Experimental Botany aims to advance understanding of plant environment interactions, including abiotic stress, mineral nutrition, and the response of plants to global change. Advancing understanding in these areas often requires manipulation of the growth environment. Experiments range in scale and include: growth chambers (Yiotis et al., 2020), glasshouses (Rho et al., 2019), whole plant chambers (Sharwood et al., 2017), and open-air field experiments (Ruiz-Vera et al., 2020). The application of environmental manipulations can be constrained by available resources, operational costs, and time. In designing experiments, researchers attempt to balance logistical challenges with the desire to address scientific questions and maximize statistical power.

54 ENVIRONMENTAL SCIENCES↗

Electron ionization via dark matter-electron scattering and the Migdal effect

There are currently several existing and proposed experiments designed to probe sub-GeV dark matter (DM) using electron ionization in various materials. The projected signal rates for these experiments assume that this ionization yield arises only from DM scattering directly off electron targets, ignoring secondary ionization contributions from DM scattering off nuclear targets. We investigate the validity of this assumption and show that if sub-GeV DM couples with comparable strength to both protons and electrons, as would be the case for a dark photon mediator, the ionization signal from atomic scattering via the Migdal effect scales with the atomic number Z and 3-momentum transfer q as Z 2 q 2 . The result is that the Migdal effect is always subdominant to electron scattering when the mediator is light, but that Migdal-induced ionization can dominate over electron scattering for heavy mediators and DM masses in the hundreds of MeV range. We put these two ionization processes on identical theoretical footing, address some theoretical uncertainties in the choice of atomic wave functions used to compute rates, and discuss the implications for DM scenarios where the Migdal process dominates, including for XENON10, XENON100, and the recent XENON1T results on light DM scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A measurement of the 2 neutrino double beta decay rate of Te-130 in the CUORICINO experiment

CUORICINO was a cryogenic bolometer experiment designed to search for neutrinoless double beta decay and other rare processes, including double beta decay with two neutrinos (2vββ). The experiment was located at Laboratori Nazionali del Gran Sasso and ran for a period of about 5 years, from 2003 to 2008. The detector consisted of an array of 62 TeO 2 crystals arranged in a tower and operated at a temperature of 10 mK. Events depositing energy in the detectors, such as radioactive decays or impinging particles, produced thermal pulses in the crystals which were read out using sensitive thermistors. The experiment included 4 enriched crystals, 2 enriched with 130 Te and 2 with 128 Te, in order to aid in the measurement of the 2vββ rate. The enriched crystals contained a total of 350 g 130 Te. The 128-enriched (130-depleted) crystals were used as background monitors, so that the shared backgrounds could be subtracted from the energy spectrum of the 130- enriched crystals. Residual backgrounds in the subtracted spectrum were fit using spectra generated by Monte-Carlo simulations of natural radioactive contaminants located in and on the crystals. The 2vββ half-life was measured to be T 2v 1/2 = [9.81± 0.96(stat)± 0.49(syst)] x10 20 y.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving Self-Driving Labs: Quantifying System-Level Experiment Repeatability and Broadening Instrument-Level Compatibility

Modular Autonomous Research System (MARS) is a self-driving laboratory (SDL) which performs wet-lab science with peptide-lanthanide combinations in an automated and, ultimately, an autonomous manner to aid in soil analysis for domestic lithium mining. Autonomous experimentation involves automated experimentation, experiment planning, and active learning. MARS consists of a 6-axis robotic arm (UR5e) on a linear rail, pipette robots (Opentrons 2), and microplate readers. These components transport, operate on, and collect data with chemical solutions in standard labware. For effective autonomy, MARS must perform system-level labware operations repeatably, plan experiments autonomously, and be portable between research-domains. Repeatability is evaluated by labware placement precision, such that future operations can properly locate labware, as well as the elapsed time, so that low variance mean estimates of experiment duration can inform high-level researcher decision making. Autonomous experiment planning is the next step to decouple experimentation from human management; however, there is a conflict between the ideal system-level experiment goals and the constraints imposed by instruments’ limitations. Sub-domain portability is a long-term goal to extend MARS’ research beyond the chemistry of peptide-lanthanide binding to other sub-domains without having to invest significant overhead to system retrofitting. To address these goals, we manually trained the robotic arm labware placement and modelled statistical failurerate and uncertainty Additionally, we benchmarked the duration and variance of each experiment sub-operation as a heuristic for research decision making. Next, we use a parameterized geometric program (PGP) approach to design experiments that optimize system-level objectives and satisfy instrument-level constraints. Lastly, we proposed a Python framework to maximize MARS’ extensibility to other scientific sub-domains through a JSON-based experiment specification.

36 MATERIALS SCIENCE↗

Atmospheric X-ray emission experiment for shuttle

An experiment designed to measure the spatial, temporal, and energy distribution of X-ray aurorae produced by precipitating electrons, is presented. The experiment will provide vital data on solar-terrestrial relationships that may lead to defining the transfer mechanism that causes certain terrestrial weather events and climatological behavior. An instrument concept is discussed, and is based on a spatially sensitive multiwire proportional counter, combined with collimators to produce X-ray images of the aurorae. An instrument pointing system, on which the counter can be mounted, will provide the required altitude control, and can be operated by a Spacelab payload specialist for full control over its observing and data taking modes.

Goldberg, R. A.↗

Toward proof of satellite anemometer concept

The S-193 oceanographic program is designed to demonstrate the operational feasibility of measuring ocean surface winds on a global basis with a composite radar-radiometer sensor. Near-simultaneous radiometric/scatterometric measurements offer a better opportunity to make improved estimates of surface winds through a variety of atmospheric conditions. Support is presented in developing interpretational techniques for the joint measurements, designing experiments to verify the joint interpretation techniques, predicting the observations from theory, evaluating system effects on the measurements, and developing system design criteria.

Classen, J.↗