Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

A Review: PFAS Adsorption, Sensing, and Remediation with Engineered Nanoporous Materials

Per- and polyfluoroalkyl substances (PFAS) are among the most abundant environmental contaminant species. They are widespread due to uncontrolled industrial and commercial use and have been linked to health risks such as cancer. With rising global concerns about the public health effects of PFAS, there is an incentive to develop strategies for reliable monitoring and effective PFAS removal, particularly in drinking water. Traditional PFAS sensing techniques are inefficient due to long measurement times, high labor input, high costs, and limitations to ex situ analysis. Current commercially available sorbents for PFAS removal generally lack the ability to capture PFAS components rapidly and quantitatively. Furthermore, existing sorbents are notably inefficient in removing the more toxic, smaller PFAS chemical chains. Large-scale applications of these methods tend to be costly and resource-intensive. Pacific Northwest National Laboratory has developed unique strategies for PFAS sensing and removal with capture probe technology that has an affinity for fluorocarbons, including PFAS. For both sensing and removal, the customizable capture probes can target specific PFAS compounds since they used a metal-organic framework (MOF)-based technology that can be fine-tuned and molecularly tailored. This tailoring of the materials enables high PFAS sensitivity, selectivity, and faster uptake. PNNL’s capture probe materials have been developed into a sensing technique based on the interactions of the capture probes with PFAS at the molecular level and further transduced that to a quantifiable electrochemical response. The materials have been integrated into a sensor platform developed by New Jersey Institute of Technology (NJIT). Tunable capture probes with a range of detection sensitivities allow for faster and more sensitive PFAS detection limits as low as what appears to be 0.5 ng/L (compared to the U.S. Environmental Protection Agency health advisory level of 70 ng/L). Customization of the capture probe results in improved sorption capacities (fast kinetics and high capacities) compared to commercial granular activated carbons. This research applied various experimental and modeling tools to improve understanding the molecular level interactions between the sorbents towards PFAS adsorption properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linker-Free Magnetite-Decorated Gold Nanoparticles (Fe3O4-Au): Synthesis, Characterization, and Application for Electrochemical Detection of Arsenic (III)

Linker-free magnetite nanoparticles (Fe3O4NPs)-decorated gold nanoparticles (AuNPs) were grown using a new protocol that can be used as a new platform for synthesis of other intact metal–metal oxide nanocomposites without the need for linkers. This minimizes the distance between the metal and metal oxide nanoparticles and ensures the optimum combined effects between the two material interfaces. X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy confirmed the successful synthesis of the Fe3O4-Au nanocomposite, without any change in the magnetite phase. Characterization, using transmission electron microscopy (TEM), scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy, revealed the composite to consist of AuNPs of 70 ± 10 nm diameter decorated with tiny 10 ± 3 nm diameter Fe3O4NPs in Au:Fe mass ratio of 5:1. The prepared Fe3O4-Au nanocomposite was embedded in ionic liquid (IL) and applied for the modification of glassy carbon electrode (GCE) for the electrochemical detection of As(III) in water. By combining the excellent catalytic properties of the AuNPs with the high adsorption capacity of the tiny Fe3O4NPs towards As(III), as well as the good conductivity of IL, the Fe3O4-Au-IL nanocomposite showed excellent performance in the square wave anodic stripping voltammetry detection of As(III). Under the optimized conditions, a linear range of 1 to 100 μg/L was achieved with a detection limit of 0.22 μg/L (S/N = 3), and no interference from 100-fold higher concentrations of a wide variety of cations and anions found in water. A very low residual standard deviation of 1.16% confirmed the high precision/reproducibility of As(III) analysis and the reliability of the Fe3O4-Au-IL sensing interface. Finally, this proposed sensing interface was successfully applied to analyzing synthetic river and wastewater samples with a 95–101% recovery, demonstrating excellent accuracy, even in complex synthetic river and wastewater samples containing high concentrations of humic acid without any sample pretreatments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DNA Methylation as a Biomarker for Preeclampsia

Background: Preeclampsia contributes significantly to pregnancy-associated morbidity and mortality as well as future risk of cardiovascular disease in mother and offspring, and preeclampsia in offspring. The lack of reliable methods for early detection limits the opportunities for prevention, diagnosis, and timely treatment. Purpose: The purpose of this study was to explore distinct DNA methylation patterns associated with preeclampsia in both maternal cells and fetal-derived tissue that represent potential biomarkers to predict future preeclampsia and inheritance in children. Method: A convenience sample of nulliparous women (N = 55) in the first trimester of pregnancy was recruited for this prospective study. Genome-wide DNA methylation was quantified in first-trimester maternal peripheral white blood cells and placental chorionic tissue from normotensive women and those with preeclampsia (n = 6/group). Results: Late-onset preeclampsia developed in 12.7% of women. Significant differences in DNA methylation were identified in 207 individual linked cytosine and guanine (CpG) sites in maternal white blood cells collected in the first trimester (132 sites with gain and 75 sites with loss of methylation), which were common to approximately 75% of the differentially methylated CpG sites identified in chorionic tissue of fetal origin. Conclusion: This study is the first to identify maternal epigenetic targets and common targets in fetal-derived tissue that represent putative biomarkers for early detection and heritable risk of preeclampsia. Findings may pave the way for diagnosis of preeclampsia prior to its clinical presentation and acute damaging effects, and the potential for prevention of the detrimental long-term sequelae.

biomarker↗

Absolute charge calibration of scintillating screens for relativistic electron detection

We report on new charge calibrations and linearity tests with high-dynamic range for eight different scintillating screens typically used for the detection of relativistic electrons from laser-plasma based acceleration schemes. The absolute charge calibration was done with picosecond electron bunches at the ELBE linear accelerator in Dresden. The lower detection limit in our setup for the most sensitive scintillating screen (KODAK Biomax MS) was 10 fC/mm{sup 2}. The screens showed a linear photon-to-charge dependency over several orders of magnitude. An onset of saturation effects starting around 10-100 pC/mm{sup 2} was found for some of the screens. Additionally, a constant light source was employed as a luminosity reference to simplify the transfer of a one-time absolute calibration to different experimental setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Environmental Applications of Stable Xenon and Radioxenon Monitoring

Improved detection capabilities are needed at several Department of Energy sites to make remedial decisions about facilities and landfill cleanup. For facility monitoring air samples can be collected from within a facility and analyzed for short lived radioxenons to estimate inventories of residual plutonium holdup within the facility. For landfill cleanup activities soil gas sampling for xenon isotopes can be used to define the locations of spent fuel and transuranic wastes. Short-lived radioxenon isotopes are continuously produced by spontaneous fission of plutonium-240 in transuranic wastes. Large volume soil-gas samples provide extremely sensitive measurement of radioxenon in the subsurface; a characteristic of transuranic waste. The analysis employs a modified Automated Radioxenon Sampling and Analysis (ARSA) system. Proof of principle measurements at a Hanford Site liquid waste disposal site showed xenon-133 at levels in soil gas are approximately 16,000 times the detection limit and lower levels of xenon-135 from the spontaneous fission of plutonium-240 were also measured. Stable xenon isotopes are also produced by spontaneous fission but are subject to background concentrations in ambient air samples (facilities) but less so in soil gas where free exchange with ambient air is restricted. Rare gas mass spectrometry is used for highly precise stable xenon isotopic measurements. Stable xenon isotopic ratios from fission are distinct from natural xenon background ratios. Neutron capture on xenon-135 produces an excess of xenon-136 above fission ratios and thus provides a means of distinguishing reactor sources (e.g. spent fuel) from separated transuranic materials (plutonium).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

3D MoS 2 Aerogel for Ultrasensitive NO 2 Detection and Its Tunable Sensing Behavior

A high-performance NO 2 sensor based on the 3D MoS 2 aerogel is introduced. Compared to single- or few-layer MoS2, 3D assemblies of 2D MoS 2 provide more surface area per footprint with a simple and scalable synthesis. Integration of the 3D MoS 2 aerogel on a low-power microheater platform is demonstrated, and the sensing behavior of the 3D MoS 2 aerogel is investigated. A two-step sulfurization treatment is developed to obtain a high-quality MoS 2 aerogel with strong sensing performance. The aerogel exhibits low detection limit (50 ppb) toward NO 2 at room temperature, while after the two-step sulfurization treatment, it also exhibits fast response and recovery at low heater temperature of 200 °C, with no decrease in sensitivity. The observed p-type sensing behavior of MoS 2 aerogel is discussed and identified as being controlled by the defect state (as probed by the S:Mo ratio). Furthermore, annealing in a hydrogen environment changes the defect state of the MoS 2 aerogel by creating more sulfur vacancies; concomitantly, a transition from p-type sensing behavior to n-type sensing is observed

36 MATERIALS SCIENCE↗

Fabrication of Co3O4/PEI-GO composites for gas-sensing applications at room temperature

Highlights: • A new controllable dispersion of Co{sub 3}O{sub 4}/PEI-GO is synthesized by hydrothermal method. • The Co{sub 3}O{sub 4}/PEI-GO displays perfect sensing performance at room temperature to NO{sub x} detection. • It shows lower detection limit of the thin film sensor down to 100 ppb in the air at room temperature. • In Situ Diffuse Reflectance Infrared Transform Spectroscopy (DRIFT) has been made to understand the adsorption of NO{sub x}. • The electronic core-shell configuration model and equivalent circuits has been establishes to explain the gas mechanism. - Abstract: In this work, highly dispersed and different morphologies of Co{sub 3}O{sub 4} on the surface of GO modified with polyethylenimine (PEI) were synthesized by hydrothermal method at different temperatures. Co{sub 3}O{sub 4}/PEI-GO exhibited better gas sensing properties for NO{sub x} gas than the pure Co{sub 3}O{sub 4} and Co{sub 3}O{sub 4}/GO. Especially, the Co{sub 3}O{sub 4}/PEI-GO composite with hydrothermal at 190 °C for 3 h showed excellent sensitive characteristics to NO{sub x} at room temperature. The cause of good gas sensing property come mainly from the synergy between Co{sub 3}O{sub 4} and graphene oxide (GO) modified with PEI, which can significantly enhance the gas sensing performance. The adsorption species of NO{sub x} on the surface of Co{sub 3}O{sub 4}/PEI-GO composite sensor was detectable by In Situ Diffuse Reflectance Infrared Transform Spectroscopy (DRIFT). The electronic core-shell configuration model has been established to illustrate the resistance change when the Co{sub 3}O{sub 4} is exposed to oxidizing gases. Hence, the Co{sub 3}O{sub 4}/PEI-GO composite materials are promising in application of detecting NO{sub x} gas sensing.

36 MATERIALS SCIENCE↗

Capabilities of the INL ZPPR to Support Active Interrogation Research with SNM

For over 40 years Idaho National Laboratory (INL) and its predecessor organizations have maintained and operated the Zero-Power Physics Reactor (ZPPR) as a test bed for studying reactor physics and nuclear reactor design. Although the ZPPR is no longer operated as an active research reactor, it’s infrastructure (radiation shielding, safety systems, physical safeguards) and special nuclear material (SNM) inventory (variably enriched uranium and plutonium fuels available in metallic, oxide, alloy, and other forms) still makes the facility a unique national resource for research and development activities involving the use of SNM. Recently INL has utilized this facility to serve as a test and evaluation facility for active interrogation research and development. This facility is currently hosting scoping experiments using neutron and x-ray radiation sources to characterize SNM active interrogation signatures and to develop tools and techniques to detect and identify shielded SNM. This paper presents an overview of the facility’s infrastructure and assets and describes recent active interrogation experiments that have taken place using high-energy x-ray sources and compact electronic neutron generators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrading Biogas through in situ Conversion of Carbon Dioxide to Biomethane in Anaerobic Digesters

Organic waste streams generated by wastewater treatment plants, agricultural operations, and food processing industries represent an important yet underutilized opportunity for renewable energy production in the United States. Through anaerobic digestion, these waste streams can produce biogas, a mixture primarily composed of methane (CH4) and carbon dioxide (CO2), that can be upgraded to pipeline-quality natural gas. However, most existing upgrading technologies remove CO2 from biogas rather than utilizing it, leaving a significant portion of the potential energy unused. This project investigates a novel biological upgrading approach that converts CO2 into additional CH4 by supplying hydrogen (H2) to specialized microorganisms capable of performing hydrogenotrophic methanation. The main challenges associated with biological biogas upgrading are related to hydrogen supply, gas-liquid mass transfer, and process stability. First, due to the high cost of hydrogen gas, it is preferable that H2 be produced on-site using renewable energy sources such as wind or solar power. Second, hydrogen has low solubility in liquids, which limits its availability to microorganisms and requires strategies to improve gas dissolution and transfer within the reactor. Third, process inhibition may occur as a result of increased pH caused by CO2 consumption or elevated H2 partial pressure, both of which can negatively affect methanogenic activity. Although research in these areas has advanced during the course of this project, these challenges have not yet been fully resolved. To date, the biological systems that have achieved the highest methane concentrations are typically ex-situ reactors, where operational conditions can be more easily controlled. For this reason, the findings of the present project remain highly relevant. The project goal was to develop an innovative system that can accomplish biogas upgrading via biological conversion of CO2 to CH4, in a novel hybrid approach that combines the advantages of both in-situ and ex-situ systems. The proposed system employs a three-phase upflow anaerobic bioreactor with H2 delivery through a gas-permeable membrane, enabling efficient hydrogen transfer and microbial conversion. Under optimized operating conditions, the system achieved 99% H2 consumption and 90% CO2 conversion. A subsequent gas cleaning stage was implemented to further improve gas quality and meet target purity standards. The upgraded gas composition reached 97.7% CH4, 2.2% CO2, and 0.97% O2, while H2S concentrations remained below detection limits. In addition, a flue gas-driven inorganic thermoelectric generator (TEG) system was designed and experimentally validated as a potential source of electricity for H2 production. The system consisted of six TEG modules connected in series and achieved an open-circuit voltage of 4.5 V and a maximum power output of 224 mW at a temperature difference of approximately 53.5 °C, demonstrating effective conversion of waste heat into electrical power under simulated flue gas conditions. Finally, a comprehensive techno-economic analysis was completed to evaluate the capital and operating costs associated with the proposed system. The results provide important insights to guide future scale-up, optimization, and potential deployment of integrated biological biogas upgrading technologies.

09 BIOMASS FUELS↗

A technique for synthesizing metal tritide standards

Before surplus plutonium pits can be decommissioned and converted into metal oxides to be used as reactor fuels, residual tritium must be reduced to an acceptable level. We have developed two analytical methods involving melting and acid dissolution, combined with liquid scintillation counting as a quantitative and sensitive technique for measuring residual tritium in Pu metal. The detection limit, linearity, and reproducibility of these analytical methods must be validated with a series of metal tritide standards. Since there are no commercially available metal tritide standards, we have developed a technique for their synthesis. The synthesis of these low-level metal tritide standards is accomplished by charging cerium powder with a known amount of tritium to form a master cerium tritide alloy and then by aliquoting from this master alloy and diluting with pure cerium powder to form a series of standards with different tritium concentrations. The major difficulty in synthesizing these standards is that the samples contain extremely low levels of tritium, which span over three decades of concentrations. The synthesis technique and initial data obtained for cerium hydride samples will be presented. (authors)

36 MATERIALS SCIENCE↗

Lessons from Earth Bioaerosol Sampling for Venus Habitability & Biosignature Science

Venus’s clouds are often discussed as a potential habitat. Several high-priority science goals – cloud aerosol composition, internal radiative flux, and aerosol residence time and circulation models – will improve our understanding of Venus in an astrobiology context. Lessons from Earth’s aerobiosphere can inform these requirements and interpretation of results. A stable Venus aerobiosphere would need microorganisms to reproduce faster than they settle out due to gravity. This is a joint constraint of the potential nutrients and energy influx, bioenergetic costs such as desiccation and radiation damage, and aerosol dynamics. Though life cycles involving S- and Fe-based redox metabolism have been proposed, at an optimistic estimate of 75% H2SO4, Venus aerosol water activity (aw) is still ~0.02, far below the observed microbial growth limit of ~0.6. Long-term desiccation with brief spurts of repair, growth and reproduction in response to transient water influx (perhaps volcanism) is the most likely model for Earth-like life on Venus – a ‘desert bloom’ scenario. In Earth’s troposphere, clouds can carry 103 – 105 cells/mL, some metabolically active. A better analogue may be Earth’s stratospheric sulfate aerosol layer: supercooled sulfuric acid aerosols (acid weight fraction 0.6 – 0.85, 0.1 – 1 µm diameter, 0.1 – 1 cm-3) with little water activity, long residence times, high UV radiation, and only sporadic influx from surface particle sources. Viable cells isolated from this region are rare (~102 cells/m3), though ‘hot spots’ at tropospheric mixing occur. Cells are primarily in inactive forms such as spores, and it is unclear if any are associated with sulfate aerosols or simply co-located. Given the heterogeneities in Venus clouds and the model of a sparse, largely dormant ecosystem, a single transect on descent would most likely pass through a low-water, inactive region, missing potential signs of habitability or biosignatures. Even a passive aerial platform (balloon) may end up following a single air mass over its lifetime. A better strategy for Venus would target an aerial region with some upwelling from surface sources, and take multiple transects separated in time and space. Earth’s stratospheric bioaerosol population could provide a starting point for estimating the required lower volume and detection limits.

Earth↗

Multiple-Targeted Graphene-based Nanocarrier for Intracellular Imaging of mRNAs

Simultaneous detection and imaging of multiple intracellular messenger RNA (mRNAs) hold great significant for early cancer diagnostics and preventive medicine development. Herein, we propose a multiple-targeted graphene oxide (GO) nanocarrier that can simultaneously detect and image different type mRNAs in living cells. First of all, in vitro detection of multiple targets have been realized successfully based on the multiple-targeted GO nanocarrier with linear relationship ranging from 3 nM to 200 nM, as well as sensitive detection limit of 1.84 nM for manganese superoxide dismutase (Mn-SOD) mRNA and 2.45 nM for β-actin mRNA. Additionally, this nanosensing platform composed of fluorescent labeled single strand DNA probes and GO nanocarrier can identify Mn-SOD mRNA and endogenous mRNA of β-actin in living cancer cells, showing rapid response, high specificity, nuclease stability, and good biocompatibility during the cell imaging. Thirdly, changes of the expression levels of mRNA in living cells before or after the drug treatment can be monitored successfully. By using multiple ssDNA as probes and GO nanocarrier as the cellular delivery cargo, the proposed simultaneous multiple-targeted sensing platform will be of great potential as a powerful tool for intracellular trafficking process from basic research to clinical diagnosis.

59 BASIC BIOLOGICAL SCIENCES↗

Estimation of Radiation Doses to U.S. Military Test Participants from Nuclear Testing: A Comparison of Historical Film-Badge Measurements, Dose Reconstruction and Retrospective Biodosimetry

Retrospective radiation dose estimations, whether based on physical or biological measurements, or on theoretical dose reconstruction, are limited in their precision and reliability, particularly for exposures that occurred many decades ago. Here, we studied living U.S. military test participants, believed to have received high-dose radiation exposures during nuclear testing-related activities approximately six decades ago, with two primary goals in mind. The first was to compare three different approaches of assessing past radiation exposures: 1. Historical personnel monitoring data alone; 2. Dose reconstruction based on varying levels of completeness of individual information, which can include film badge data; and 3. Retrospective biodosimetry using chromosome aberrations in peripheral blood lymphocytes. The second goal was to use the collected data to make the best possible estimates of bone marrow dose received by a group with the highest military recorded radiation doses of any currently living military test participants. Six nuclear test participants studied had been on Rongerik Atoll during the 1954 CASTLE Bravo nuclear test. Another six were present at the Nevada Test Site (NTS) and/or Pacific Proving Ground (PPG) and were believed to have received relatively high-dose exposures at those locations. All were interviewed, and all provided a blood sample for cytogenetic analysis. Military dose records for each test participant, as recorded in the Defense Threat Reduction Agency's Nuclear Test Review and Information System, were used as the basis for historical film badge records and provided exposure scenario information to estimate dose via dose reconstruction. Dose to bone marrow was also estimated utilizing directional genomic hybridization (dGH) for high-resolution detection of radiation-induced chromosomal translocations and inversions, the latter being demonstrated for the first time for the purpose of retrospective biodosimetry. As the true dose for each test participant is not known these many decades after exposure, this study gauged the congruence of different methods by assessing the degree of correlation and degree of systematic differences. Overall, the best agreement between methods, defined by statistically significant correlations and small systematic differences, was between doses estimated by a dose reconstruction methodology that exploited all the available individual detail and the biodosimetry methodology derived from a weighted average dose determined from chromosomal translocation and inversion rates. Employing such a strategy, we found that the Rongerik veterans who participated in this study appear to have received, on average, bone marrow equivalent doses on the order of 300–400 mSv, while the NTS/ PPG participants appear to have received approximately 250–300 mSv. The results show that even for nuclear events that occurred six decades in the past, biological signatures of exposure are still present, and when taken together, chromosomal translocations and inversions can serve as reliable retrospective biodosimeters, particularly on a group-average basis, when doses received are greater than statistically-determined detection limits for the biological assays used.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Oxide derived Cu nanofibril assembly for enhanced nonenzymatic glucose sensing

In this report, we have prepared copper nanofibril assembly via thermal oxidation followed by electrochemical reduction processes, exhibiting superior glucose detection ability. The morphological analysis evidenced the formation of rough islands or nanofibril structure on the Cu surface depending on initial thermal oxidation temperature. The glucose detection performance was investigated by performing cyclic voltammetry and chronoamperometry with varying glucose concentration. A high sensitivity (4131.57 μA mM – 1 cm – 2 ), low detection limit (1.41 μM), wider linear range (0–3.9 mM) and long–term stability (30 days) have been recorded for electrode thermally oxidized at 400 °C followed by electrochemical reduction process (rCu_400). The sensitivity is almost three times higher in comparison to the planner Cu surface. This significantly enhanced glucose sensing ability rCu_400 has been attributed to the nanofibril morphology, origination of Cu (111) facet and formation of a stable oxide layer evidenced by scanning electron microscopy, X-ray diffraction and energy dispersive spectroscopy analysis. Despite higher sensitivity, rCu_400 electrode does not show any response to the chloride ion, dopamine, ascorbic acid and uric acid. Finally, these results indicate that the Cu nanofibril structure prepared via simple oxidation/reduction process can be an excellent candidate to be used as an electrode for glucose sensing application.

36 MATERIALS SCIENCE↗

Detection of ethylene gas in exhaled breath of people living in landfill using CO{sub 2} laser photoacoustic spectroscopy with multicomponent analysis

The photoacoustic spectrometer (PAS) had been built and the performance had been determined. The research was based on the conversion of the absorbed middle infra red (IR) radiation by gas confined in a closed PAS cell into standing acoustic wave, which could be detected by a suitable electroacoustic transducer such as a microphone. The lowest detection limit for this setup was (57,1 ± 0,3) ppb and quality factor was (14,5 ± 0,6) for ethylene gas in 10P14 CO{sub 2} laser line. Then, this PAS was used to measure of ethylene gas concentration in breath sample of people living in near the Piyungan Bantul Yogyakarta landfill. The result from multicomponent analysis showed that PAS enable to measure the lowest concentration of volatile organic compound (VOC), such as ethylene, which occured on ambien air in Piyungan landfill. Variaty of distance area applied in this research. In the range of ±0,5 km from landfill, we obtained the concentration of ethylene gas concentration for human breath was (1,520 ± 0,002) ppm, while in the range of ±45 km, the ethylene gas concentration for human breath was (0,424 ± 0,002) ppm. Ethylene gas concentrations in exhaled gas decreased along with increasing distance variation of the landfill.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DETECTING THE WARM-HOT INTERGALACTIC MEDIUM THROUGH X-RAY ABSORPTION LINES

The warm-hot intergalactic medium (WHIM) at temperatures 10{sup 5}-10{sup 7} K is believed to contain 30%-50% of the baryons in the local universe. However, all current X-ray detections of the WHIM at redshifts z > 0 are of low statistical significance ({approx}< 3{sigma}) and/or controversial. In this work, we aim to establish the detection limits of current X-ray observatories and explore requirements for next-generation X-ray telescopes for studying the WHIM through X-ray absorption lines. We analyze all available grating observations of Mrk 421 and obtain spectra with signal-to-noise ratios (S/Ns) of {approx}90 and 190 per 50 mA spectral bin from Chandra and XMM-Newton observations, respectively. Although these spectra are two of the best ever collected with Chandra and XMM-Newton, we cannot confirm the two WHIM systems reported by Nicastro et al. in 2005. Our bootstrap simulations indicate that spectra with such high S/N cannot constrain the WHIM with O VII column densities N{sub Ovii}{approx}10{sup 15} cm{sup -2} (corresponding to an equivalent width of 2.5 mA for a Doppler velocity of 50 km s{sup -1}) at {approx}> 3{sigma} significance level. The simulation results also suggest that it would take >60 Ms for Chandra and 140 Ms for XMM-Newton to measure the N{sub Ovii} at {>=}4{sigma} from a spectrum of a background QSO with flux of {approx}0.2 mCrab (1 Crab = 2 Multiplication-Sign 10{sup -8} erg s{sup -1} cm{sup -2} at 0.5-2 keV). Future X-ray spectrographs need to be equipped with spectral resolution R {approx} 4000 and effective area A {>=} 100 cm{sup 2} to accomplish the similar constraints with an exposure time of {approx}2 Ms and would require {approx}11 Ms to survey the 15 QSOs with flux {approx}> 0.2 mCrab along which clear intergalactic O VI absorbers have been detected.

79 ASTRONOMY AND ASTROPHYSICS↗

Iodine Distribution During Evaporation of Hanford Waste Treatment Plant Direct Feed Low Activity Waste Effluent Management Facility Simulant

The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream from the off-gas system. The baseline plan for disposition of this stream during full WTP operations is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation, and recycled to the LAW vitrification facility. However, during the Direct Feed LAW (DFLAW) scenario, planned disposition of this stream involves concentrating the condensate in a new evaporator at the Effluent Management Facility (EMF) and returning it to the LAW melter. The LAW melter condensate stream will contain components, e.g. halides and sulfates, that are volatile at melter temperatures, have limited solubility in glass waste forms, and present a material corrosion concern. Further, some minor constituents in the melter condensate, such as volatile organic compounds and iodine, have been found to be at least partially volatile in the EMF. The condensate from the EMF will be sent to the Hanford Effluent Treatment Facility (ETF). The presence of some recalcitrant organics and iodine, as 129I, are expected to be problematic in the ETF. In order to better predict and prepare for the distribution of organics and 129I in the flowsheet, it is key to understand their chemistry and experimentally determine their behavior during evaporation. To do this, modeling and testing were performed to examine the speciation of iodine under relevant conditions, as well as determine partitioning of iodine and the organics in the EMF evaporator. This overall program examines the potential treatment and immobilization of the LAW melter condensate stream to enable alternative disposal. The objective of this task was to (1) perform modeling to determine the speciation and fate of iodine species, (2) prepare a simulant of the LAW Melter Off-gas Condensate expected during DFLAW operations, (3) spike in the key volatile organics and non-radioactive iodine, and (4) demonstrate evaporation in order to predict the final composition of the effluents from the EMF evaporator to aid in planning for their disposition. The results of the modeling of iodine speciation indicate that the iodine is expected to remain in the evaporator pot as iodide and possibly iodate ion if the pH is raised to 11.5-12, which is the planned condition for the EMF. Experimental testing confirmed that the iodide remained in the evaporator concentrate and was below detection limits in all condensate and knock-out pot samples, indicating it was not volatile. The organic nitrile compounds that were added to the simulant were absent from the evaporator feed solution, either lost through evaporation, or more likely, decomposition. The acetone and methylene chloride were below the target values in the feed and condensate samples, and were presumably lost to evaporation or decomposition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Portable Quantitative High-Resolution Gamma System for In-Situ Waste, D and D, and Emergency Measurements - 18573

The Canberra ISOCS system has been a highly successful and technologically innovative product since its introduction about 22 years ago. The combination of field-portable HPGe detectors, flexible shield/collimator set, and accurate mathematical efficiency calibration software made in-situ gamma spectroscopy measurements very practical. Good quality in-situ measurements are economically beneficial for items that are either large or complex, in comparison to the cost, time and impracticality of extracting a sample for laboratory measurements or producing representative calibration standards. And where the item is not homogeneous [most of the time for in-situ measurement situations] an assay of a large part of the item has been shown to be more accurate than a few widely dispersed extracted samples [the normal case]. However the size, weight, cost and complexity of the full-size ISOCS system limit its usefulness in some situations. A companion device was recently introduced, and is the subject of this document. The gamma sensor is a 1 cm{sup 3} CZT detector. It is surrounded by an optional tungsten shield/collimator set with a tripod for support. The detector is powered solely by a USB connection from a laptop PC. The full power of the ISOCS efficiency calibration software can be used with this detector. This entire package is less than 15 kg, needs no cooling, and is quite rugged, in comparison to the 120 kg for ISOCS with sensitive HPGe detectors which need Liquid Nitrogen or electro-mechanical cooling. Furthermore this CZT package is about 1/3 the cost. This is a very complementary device for the many current ISOCS users, especially for quick initial evaluations or simple situations where the full energy resolution and sensitivity of the HPGe ISOCS are not needed. Operating nuclear power plants or those in the initial phases of decommissioning are prime examples. Their complex layout often precludes the deployment of the full-sized ISOCS system, whereas the CZT system can be hand-carried there and very quickly setup for a measurement. The small detector size, and therefore low efficiency, is not a disadvantage, and in many cases is an advantage due to the elevated radioactivity of the items. This can be used to assay items in tanks, spills on floors, activity on filters, waste or items in small containers, and waste in drums. In the event of an emergency, it can be quickly deployed to measure gas or liquid effluent streams, air particulate and iodine filters in the field, or even in-vivo thyroid activity. Examples of measurements at nuclear facilities are shown and discussed in further detail, along with estimated detection limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗