Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Quasioptical modeling of wave beams with and without mode conversion: II. Numerical simulations of single-mode beams

This work continues a series of papers where we propose an algorithm for quasioptical modeling of electromagnetic beams with and without mode conversion. The general theory was reported in the first paper of this series, where a parabolic partial differential equation was derived for the field envelope that may contain one or multiple modes with close group velocities. Here, we present a corresponding code PARADE (PAraxial RAy DEscription) and its test applications to single-mode beams in vacuum and also in inhomogeneous magnetized plasma. The numerical results are compared, respectively, with analytic formulas from Gaussian-beam optics and also with cold-plasma ray tracing. Quasioptical simulations of mode-converting beams are reported in the next, third paper of this series.

ECRH↗

Susceptibility Study of Audio Recording Devices to Electromagnetic Stimulations

Little research has been performed to study how intentional electromagnetic signals may couple into recording devices. An electromagnetic susceptibility study was performed on an analog tape recorder, a digital video camera, a wired computer microphone, and a wireless microphone system to electromagnetic interference. Devices were subjected to electromagnetic stimulations in the frequency range of 1-990 MHz and field strengths up to 4.9 V/m. Carrier and message frequencies of the stimulation signals were swept, and the impacts of device orientation and antenna polarization were explored. Message signals coupled into all devices only when amplitude modulated signals were used as stimulation signals. Test conditions that produced maximum sensitivity were highly specific to each device. Only narrow carrier frequency ranges could be used for most devices to couple messages into recordings. A basic detection technique using cross-correlation demonstrated the need for messages to be as long as possible to maximize message detection and minimize detection error. Analysis suggests that detectable signals could be coupled to these recording devices under realistic ambient conditions.

42 ENGINEERING↗

An Overview of Gemma FY2021 Verification Activities

Though the method-of-moments implementation of the electric-field integral equation plays an important role in computational electromagnetics, it provides many code-verification challenges due to the different sources of numerical error and their possible interactions. Matters are further complicated by singular integrals, which arise from the presence of a Green's function. In this report, we document our research to address these issues, as well as its implementation and testing in Gemma.

97 MATHEMATICS AND COMPUTING↗

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

Aloe arborescens juice prevents EMF-induced oxidative stress and thus protects from pathophysiology in the male reproductive system in vitro

Highlights: • Electromagnetic field (EMF) induces toxic events in spermatogenic cells. • Aloe juice prevents EMF-induced increased formation of reactive oxygen species. • Aloe juice inhibits ROS-mediated DNA damage, cell cycle arrest and apoptosis. • Aloe juice may preserves fertility from EMF-induced toxic events in mouse germ cells. More and more studies suggest that prolonged exposure to EMF may cause adverse biological effects and point directly to a significantly negative correlation between EMF and human health, especially men fertility. In our previous study, we reported that this could be related to the EMF-induced reactive oxygen species formation, followed by DNA damage, cell cycle arrest and apoptosis induction. In this study, we decided to expand our research by the search for substances which would prevent EMF-induced damage in spermatogenic cells. Such an agent seems to be Aloe arborescens Mill. juice, which was shown to possess a wide range of protective properties. The administration of aloe extract helps among others to prevent the formation of free radicals by various biochemical pathways. Therefore, the main aim of our study was to provide a significant knowledge concerning the mechanism involved in the multi-pathway cytoprotective response of aloe juice against EMF. The study was carried out in an in vitro mouse spermatogenesis pathway cell lines (GC-1 spg and GC-2 spd). Our results suggest that the aloe juice has many positive effects, especially for the cellular antioxidant systems by reducing the intracellular reactive oxygen species pool induced by EMF. In consequence, aloe juice prevents DNA damage, cell cycle arrest and therefore the viability and metabolic activity of both cell line tested are preserved. In conclusion, our study provides new insight into the underlying mechanisms through which aloe juice prevents spermatogenic cells from cytotoxic and genotoxic events.

54 ENVIRONMENTAL SCIENCES↗

Electromagnetic decays of excited states in {sup 261}Sg (Z=106) and {sup 257}Rf (Z=104)

An isomeric one-quasineutron state, likely based on the [725]11/2{sup -} Nilsson level, was identified in {sup 261}Sg by its decay via internal conversion electrons. The state has an excitation energy of approx =200 keV and a half-life of 9.0{sub -1.5}{sup +2.0} mus. {sup 261}Sg has the highest Z and A of any nucleus in which the electromagnetic decay of an isomeric state was observed to date. A separate experiment was performed on the alpha daughter nucleus of {sup 261}Sg, namely {sup 257}Rf. Spectroscopy of delayed gamma rays and converted electrons from {sup 257}Rf resulted in the identification of a K isomer at an excitation energy of approx =1125 keV with a half-life of 134.9 +- 7.7 mus. The spin of the isomeric state is tentatively assigned I=21/2,23/2 and the state likely decays to a rotational band built on the [725]11/2{sup -} Nilsson level via a DELTAK=5 or 6 transition. The present results provide new information on excited states in the transactinide region, which is important for testing models of the heaviest elements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Heat Load Diamond Monochromator Project at ESRF

Due to its outstanding thermal properties, diamond is an attractive alternative to silicon as a monochromator material for high intensity X-ray beams. To date, however, the practical applications have been limited by the small size and relatively poor crystallographic quality of the crystals available. The ESRF Diamond Project Group has studied the perfection of diamonds in collaboration with industry and universities. The group has also designed and tested different stress-free mounting techniques to integrate small diamonds into larger X-ray optical elements. We now propose to develop a water-cooled Bragg-Bragg double crystal monochromator using diamond (111) crystals. It will be installed on the ESRF undulator beamline, ID06, for testing under high heat load. This monochromator will be best suited for the low energy range, typically from {approx}3.4 keV to 15 keV, due to the small size of the diamonds available and the size of the beam footprint. This paper presents stress-free mounting techniques studied using X-ray diffraction imaging, and their thermal-mechanical analysis by finite element modelling, as well as the status of the ID06 monochromator project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing Klod detector prototypes and results of their experimental tests

The projected KLOD facility is intended for finding and investigating the ultrarare decay K{sub L}{sup 0} {sup {yields} {pi}0{nu}{nu}}-bar; its branching ratio predicted by the Standard Model is Br = (3.0 {+-} 0.6) x 10{sup -11}. Designing and testing the prototype of the decay-volume veto system and beam veto calorimeter, which are the most important detectors of the facility, are considered. It is shown that the proposed beam veto calorimeter is able to detect {gamma} rays with a high efficiency at the neutron flux of 300 MHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the Lightning Strike Damage Tolerance for CFRP Composite Laminates Containing Conductive Nanofillers

Conductive nanofillers, such as carbon nanotube, graphene nanoplatelets, and carbon black particles (with diameters in nanometers) have been shown to enhance the electrical conductivity of fiber reinforced polymer matrix composites in many existing studies. The motivation is primarily for lightning strike protection, electromagnetic interference shielding, de-icing, and the manufacturing of lightweight electronic components. Here, we evaluate the lightning strike damage tolerance of carbon fiber reinforced polymer (CFRP) matrix composite laminates containing conductive nanofillers with varying weight fractions, including carbon black (CB), carbon nanotubes (CNT), and a mix of CB and CNT, through simulated lightning strike tests, followed by both non-destructive ultrasonic inspection and destructive sectioning to characterize the damage inflicted by the simulated lightning strike. Three-point flexural tests are performed to evaluate the residual strength retained by all CFRP specimens. Results show that lightning strike damage experienced varying levels of reduction for CFRP composite specimens containing conductive fillers in comparison to the baseline specimen without fillers. Notably, the delamination only penetrated to the interface between the 1st and 2nd layer for the specimen with 0.25 wt.% CNT in comparison to the baseline CFRP specimen for which the delamination penetrated to the interface between the 5th and 6th layer. Moreover, the retention of the flexural modulus increased from 26.5% to a maximum of 95.0% for the specimen with 0.25 wt.% hybrid CB and CNT. Yet, we show that using our chosen conductive fillers cannot fully eliminate lightning strike damage. Additionally, adding conductive fillers could compromise the flexural properties. We provide discussions on future recommendations on using conductive fillers for the lightning strike protection of CFRP composites.

36 MATERIALS SCIENCE↗

Design of a signal conditioner for the Fermilab Magnet Test Facility

This thesis describes the design of a remotely-programmable signal conditioner for the harmonic measurement of accelerator magnets. A 10-channel signal conditioning circuit featuring bucking capabilities was designed from scratch and implemented to the level of the printed circuit board layout. Other system components were chosen from those available on the market. Software design was started with the definition of routine procedures. This thesis is part of an upgrade project for replacing obsolescent automated test equipment belonging to the Fermilab Magnet Test Facility. The design started with a given set of requirements. Using a top-down approach, all the circuits were designed and their expected performances were theoretically predicted and simulated. A limited prototyping phase followed. The printed circuit boards were laid out and routed using a CAD software and focusing the design on maximum electromagnetic interference immunity. An embedded board was selected for controlling and interfacing the signal conditioning circuitry with the instrumentation network. Basic low level routines for hardware access were defined. This work covered the entire design process of the signal conditioner, resulting in a project ready for manufacturing. The expected performances are in line with the requirements and, in the cases where this was not possible, approval of trade-offs was sought and received from the end users. Part I deals with the global structure of the signal conditioner and the subdivision in functional macro-blocks. Part II treats the hardware design phase in detail, covering the analog and digital circuits, the printed circuit layouts, the embedded controller and the power supply selection. Part III deals with the basic hardware-related routines to be implemented in the final software.

43 PARTICLE ACCELERATORS↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A planar refractive x-ray lens made of nanocrystalline diamond

Diamond has unique properties which make it the ideal material for use in synchrotron instrumentation. X-ray optics made of diamond are almost transparent, they possess strength, and are subject to very low thermal expansion; therefore they will be able to withstand the powerful beams generated by fourth-generation light sources without compromising brilliance. For this reason, several groups are attempting fabrication of refractive lenses and zone plates made of diamond. Lithography and, in general, microfabrication technology, are the ultimate tools for the innovation of synchrotron focusing optics. We propose to combine modern silicon microtechnology with advanced deposition methods to fabricate nanocrystalline-diamond lenses for third- and fourth-generation synchrotron sources. The fabrication method is described here and microfocusing synchrotron tests are illustrated.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

THE AROMATIC FEATURES IN VERY FAINT DWARF GALAXIES

We present optical and mid-infrared photometry of a statistically complete sample of 29 dwarf galaxies (M{sub r} > - 15 mag) selected from the Sloan Digital Sky Survey (SDSS) spectroscopic sample and observed in the mid-infrared with Spitzer IRAC. This sample contains nearby (redshift {approx}<0.005) galaxies 3 mag fainter than previously studied samples. We compare our sample with other star-forming galaxies that have been observed with both IRAC and SDSS. We examine the relationship of the infrared color, [3.6]-[7.8], sensitive to polycyclic aromatic hydrocarbon (PAH) abundance and also hot dust and stellar continuum, with star formation rates (SFRs), oxygen abundances, and radiation hardness, all estimated by optical emission lines. Consistent with studies of more luminous dwarfs, we find that these dwarf galaxies show much redder [3.6]-[7.8] color than luminous galaxies with similar specific SFRs. Unlike luminous galaxies, we find that these dwarf galaxies show no significant dependence at all of the [3.6]-[7.8] color on SFR, oxygen abundance, or radiation hardness, despite the fact that the sample spans a significant range in all of these quantities. When the dwarfs in our sample are compared with more luminous dwarfs, we find that the [3.6]-[7.8] color, potentially tracing the PAH emission, depends on oxygen abundance and radiation hardness. However, these two parameters are correlated with one another as well; we break this degeneracy by looking at the PAH-oxygen abundance relation at a fixed radiation hardness and the PAH-hardness relation at a fixed oxygen abundance. This test shows that the [3.6]-[7.8] color in dwarf galaxies appears to depend more directly on oxygen abundance based on the data currently available.

79 ASTRONOMY AND ASTROPHYSICS↗

USING THE X-RAY MORPHOLOGY OF YOUNG SUPERNOVA REMNANTS TO CONSTRAIN EXPLOSION TYPE, EJECTA DISTRIBUTION, AND CHEMICAL MIXING

Supernova remnants (SNRs) are a complex class of sources, and their heterogeneous nature has hindered the characterization of their general observational properties. To overcome this challenge, in this paper, we use statistical tools to analyze the Chandra X-ray images of Galactic and Large Magellanic Cloud SNRs. We apply two techniques, a power-ratio method (a multipole expansion) and wavelet-transform analysis, to measure the global and local morphological properties of the X-ray line and thermal emission in 24 SNRs. We find that Type Ia SNRs have statistically more spherical and mirror-symmetric thermal X-ray emission than core-collapse (CC) SNRs. The ability to type SNRs based on thermal emission morphology alone enables, for the first time, the typing of SNRs with weak X-ray lines and those with low-resolution spectra. Based on our analyses, we identify one source (SNR G344.7-0.1) as originating from a CC explosion that was of unknown origin previously; we also confirm the tentative Type Ia classifications of G337.2-0.7 and G272.2-3.2. Although the global morphology is indicative of the explosion type, the relative morphology of the X-ray line emission within SNRs is not: all sources in our sample have well-mixed ejecta, irrespective of stellar origin. In particular, we find that 90% of the bright metal-line-emitting substructures are spatially coincident and have similar scales, even if the metals arise from different burning processes. Moreover, the overall X-ray line morphologies within each SNR are the same, with <6% differences. These findings reinforce observationally that hydrodynamical instabilities can efficiently mix ejecta in Type Ia and CC SNRs. The only exception is W49B, which can be attributed to its jet-driven/bipolar explosive origin. Based on comparative analyses across our sample, we describe several observational constraints that can be used to test hydrodynamical models of SNR evolution; notably, the filling factor of X-ray emission decreases with SNR age.

79 ASTRONOMY AND ASTROPHYSICS↗

GLIESE 581D IS THE FIRST DISCOVERED TERRESTRIAL-MASS EXOPLANET IN THE HABITABLE ZONE

It has been suggested that the recently discovered exoplanet GJ581d might be able to support liquid water due to its relatively low mass and orbital distance. However, GJ581d receives 35% less stellar energy than Mars and is probably locked in tidal resonance, with extremely low insolation at the poles and possibly a permanent night side. Under such conditions, it is unknown whether any habitable climate on the planet would be able to withstand global glaciation and/or atmospheric collapse. Here we present three-dimensional climate simulations which demonstrate that GJ581d will have a stable atmosphere and surface liquid water for a wide range of plausible cases, making it the first confirmed super-Earth (exoplanet of 2-10 Earth masses) in the habitable zone. We find that atmospheres with over 10 bar CO{sub 2} and varying amounts of background gas (e.g., N{sub 2}) yield global mean temperatures above 0{sup 0}C for both land and ocean-covered surfaces. Based on the emitted IR radiation calculated by the model, we propose observational tests that will allow these cases to be distinguished from other possible scenarios in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Flavor-dependent radiative corrections in coherent elastic neutrino-nucleus scattering

We calculate coherent elastic neutrino-nucleus scattering cross sections on spin-0 nuclei (e.g. 40 Ar and 28 Si) at energies below 100 MeV within the Standard Model and account for all effects of permille size. We provide a complete error budget including uncertainties at nuclear, nucleon, hadronic, and quark levels separately as well as perturbative error. Our calculation starts from the four-fermion effective field theory to explicitly separate heavy-particle mediated corrections (which are absorbed by Wilson coefficients) from light-particle contributions. Electrons and muons running in loops introduce a non- trivial dependence on the momentum transfer due to their relatively light masses. These same loops, and those mediated by tau leptons, break the flavor universality because of mass-dependent electromagnetic radiative corrections. Nuclear physics uncertainties significantly cancel in flavor asymmetries resulting in subpercent relative errors. We find that for low neutrino energies, the cross section can be predicted with a relative precision that is competitive with neutrino-electron scattering. We highlight potentially useful applications of such a precise cross section prediction ranging from precision tests of the Standard Model, to searches for new physics and to the monitoring of nuclear reactors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and implementation of the AMIGA embedded system for data acquisition

The Auger Muon Infill Ground Array (AMIGA) is part of the AugerPrime upgrade of the Pierre Auger Observatory. It consists of particle counters buried 2.3 m underground next to the water-Cherenkov stations that form the 23.5 km 2 large infilled array. The reduced distance between detectors in this denser area allows the lowering of the energy threshold for primary cosmic ray reconstruction down to about 1017 eV. At the depth of 2.3 m the electromagnetic component of cosmic ray showers is almost entirely absorbed so that the buried scintillators provide an independent and direct measurement of the air showers muon content. This work describes the design and implementation of the AMIGA embedded system, which provides centralized control, data acquisition and environment monitoring to its detectors. The presented system was firstly tested in the engineering array phase ended in 2017, and lately selected as the final design to be installed in all new detectors of the production phase. The system was proven to be robust and reliable and has worked in a stable manner since its first deployment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting spoke cavities for high-velocity applications

To date, superconducting spoke cavities have been designed, developed, and tested for particle velocities up to {beta}{sub 0}~0.6, but there is a growing interest in possible applications of multispoke cavities for high-velocity applications. We have explored the design parameter space for low-frequency, high-velocity, double-spoke superconducting cavities in order to determine how each design parameter affects the electromagnetic properties, in particular the surface electromagnetic fields and the shunt impedance. We present detailed design for cavities operating at 325 and 352 MHz and optimized for {beta}{sub 0}~=0.82 and 1.

43 PARTICLE ACCELERATORS↗