Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Performance Test Results of the NASA-457M v2 Hall Thruster

Performance testing of a second generation, 50 kW-class Hall thruster labeled NASA-457M v2 was conducted at the NASA Glenn Research Center. This NASA-designed thruster is an excellent candidate for a solar electric propulsion system that supports human exploration missions. Thruster discharge power was varied from 5 to 50 kW over discharge voltage and current ranges of 200 to 500 V and 15 to 100 A, respectively. Anode efficiencies varied from 0.56 to 0.71. The peak efficiency was similar to that of other state-of-the-art high power Hall thrusters, but outperformed these thrusters at lower discharge voltages. The 0.05 to 0.18 higher anode efficiencies of this thruster compared to its predecessor were primarily due to which of two stable discharge modes the thruster was operated. One stable mode was at low magnetic field strengths, which produced high anode efficiencies, and the other at high magnetic fields where its predecessor was operated. Cathode keeper voltages were always within 2.1 to 6.2 V and cathode voltages were within 13 V of tank ground during high anode efficiency operation. However, during operation at high magnetic fields, cathode-to-ground voltage magnitudes increased dramatically, exceeding 30 V, due to the high axial magnetic field strengths in the immediate vicinity of the centrally-mounted cathode. The peak thrust was 2.3 N and this occurred at a total thruster input power of 50.0 kW at a 500 V discharge voltage. The thruster demonstrated a thrust-to-power range of 76.4 mN/kW at low power to 46.1 mN/kW at full power, and a specific impulse range of 1420 to 2740 s. For a discharge voltage of 300 V, where specific impulses would be about 2000 s, thrust efficiencies varied from 0.57 to 0.63.

Soulas, George C.↗

System and method for damping vibration in a drill string using a magnetorheological damper

A system for damping vibration in a drill string can include a magnetorheological fluid valve assembly having a supply of a magnetorheological fluid. A remanent magnetic field is induced in the valve during operation that can be used to provide the magnetic field for operating the valve so as to eliminate the need to energize the coils except temporarily when changing the amount of damping required. The current to be supplied to the coil for inducing a desired magnetic field in the valve is determined based on the limiting hysteresis curve of the valve and the history of the magnetization of the value using a binary search methodology. The history of the magnetization of the valve is expressed as a series of sets of current and it resulting magnetization at which the current experienced a reversal compared to prior values of the current.

42 ENGINEERING↗

Universal bounds on operator dimensions from the average null energy condition

We show that the average null energy condition implies novel lower bounds on the scaling dimensions of highly-chiral primary operators in four-dimensional conformal field theories. Denoting the spin of an operator by a pair of integers ($k\overline{k}\ $) specifying the transformations under chiral su (2) rotations, we explicitly demonstrate these new bounds for operators transforming in (k, 0) and (k, 1) representations for sufficiently large k. Based on these calculations, along with intuition from free field theory, we conjecture that in any unitary conformal field theory, primary local operators of spin ($k\overline{k}\ $) and scaling dimension Δ satisfy Δ ≥ max{$k\overline{k}\ $}. If |$k-\overline{k}\ $| > 4 , this is stronger than the unitarity bound.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Techno-economic life cycle assessment of CO 2 -EOR operations towards net negative emissions at farnsworth field unit

Optimizations of CO 2 Water Alternating Gas(WAG)- systems with multi-objectives of incremental recovery and maximization of CO 2 storage are challenging. Here, the incorporation of a total Greenhouse gas (GHG) life cycle assessment is mostly ignored leading to inaccurate estimation of overall net carbon emissions of their operations. In this study, the effect of a total GHG life cycle assessment on a multi-objective CO 2 -WAG optimization with integrated techno-economic assessment (TEA) which factors carbon tax credit is conducted. A life cycle assessment (LCA) was conducted utilizing a 20 -year optimized post history matched data from a high fidelity reservoir simulation model. Using data generated from the optimum result, a techno-economic life cycle analysis was further conducted. The first scenario classified as the base model had an estimated 81% of purchased CO 2 sequestered. The results through a comprehensive techno-economic LCA model yielded a net estimate of 73% of purchased CO 2 . The optimized forecasted model which considered key operational and reservoir factors such as WAG ratio, injection rates and periods, and well specification resulted in an improved sequestration of 92% of purchased CO 2 . However, this also dropped to 84% after taking it through LCA. These results clearly indicate a significant amount of net CO 2 is not accounted for when operations are not analyzed through LCA. From the LCA, direct flaring volumes of CO 2 , energy consumption and efficiency of unit equipment were noticed to be the major causes of these reductions. Considering ten main sources of energy as source of energy generation, a comparative techno-eco LCA was conducted. The results confirmed a lower net volume and NPV for energy sources with higher carbon footprints and vice versa. Thus, a total LCA of CO 2 -WAG greatly influences net storage factor of purchased CO 2 and hence project NPV where tax credit/incentives per ton of CO 2 sequestered is considered. Although operational conditions are optimized for best results, there are significant factors that leads to minimization of net storage factor. This study therefore provides an insightful information for optimizing CO 2 -WAG multi-objectives to achieve minimum GHG emission.

02 PETROLEUM↗

Stratospheric temperature-ozone relationships 1978-1986

Global stratospheric temperature and geopotential height at eight pressure levels (70, 50, 30, 10, 5, 2, 1, and 0.4 hPa) were derived at NMC daily since October 1978. These fields are based on NOAA operational satellite sounder information. Comparable daily global fields of stratospheric ozone (30 to 0.4 hPa and total ozone) were derived from the SBUV instrument on Nimbus 7 and are now derived from the operational NOAA SBUV/2 instrument. The ozone and meteorological fields are verified against ground based measurements (Umkehr, balloon, rocket, lidar) to determine fields of temperature and ozone was assembled. Some of the interesting features of correlation between the synoptic patterns of the two data sets as well as their change with time are discussed. Seasonal as well as interannual variations in the patterns of correlation are compared in the Northern and Southern Hemisphere polar regions. Other outstanding features in both the temperature and ozone fields are highlighted.

Gelman, M. E.↗

Examination, evaluation and repair of laminated wood blades after service on the Mod-OA wind turbine

Laminated wood blades were designed, fabricated, and installed on a 200-KW wind turbine (Mod-OA). The machine uses a two-blade rotor with a diameter of 38.1 m (125 ft). Each blade weights less than 1361 kg (3000 lb). After operating in the field, two blade sets were returned for inspection. One set had been in Hawaii for 17 months (7844 hr of operation) and the other had been at Block Island, Rhode Island, for 26 months (22 months operating - 7564 hr). The Hawaii set was returned because of one of the studs that holds the blade to the hub had failed. This was found to be caused by a combination of improper installation and inadequate corrosion protection. No other problems were found. The broken stud (along with four others that were badly corroded) was replaced and the blades are now in storage. The Block Island set of blades was returned at the completion of the test program, but one blade was found to have developed a crack in the leading edge along the entire span. This crack was found to be the result of a manufacturing process problem but was not structurally critical. When a load-deflection test was conducted on the cracked blade, the response was identical to that measured before installation. In general, the laminate quality of both blade sets was excellent. No significant internal delamination or structural defects were found in any blade. The stud bonding process requires close tolerance control and adequate corrosion protection, but studs can be removed and replaced without major problems. Moisture content stabilization does not appear to be a problem, and laminated wood blades are satisfactory for long-term operation on Mod-OA wind turbines.

Faddoul, J. R.↗

Space Operations Analysis Using the Synergistic Engineering Environment

The Synergistic Engineering Environment has been under development at the NASA Langley Research Center to aid in the understanding of the operations of spacecraft. This is accomplished through the integration of multiple data sets, analysis tools, spacecraft geometric models, and a visualization environment to create an interactive virtual simulation of the spacecraft. Initially designed to support the needs of the International Space Station, the SEE has broadened the scope to include spacecraft ranging from low-earth orbit to deep space missions. Analysis capabilities within the SEE include rigid body dynamics, kinematics, orbital mechanics, and payload operations. This provides the user the ability to perform real-time interactive engineering analyses in areas including flight attitudes and maneuvers, visiting vehicle docking scenarios, robotic operations, plume impingement, field of view obscuration, and alternative assembly configurations. The SEE has been used to aid in the understanding of several operational procedures related to the International Space Station. This paper will address the capabilities of the first build of the SEE, present several use cases of the SEE, and discuss the next build of the SEE.

Angster, Scott↗

Automated rover sequence report generation

A web-based rover mission operations report and its various elements are described. The system was used for documentation of the Field Integrated Development and Operations (FIDO) rover May 2000 field test and results from the field test are provided. Implementation of automated sequence report generation for the operations report is explained in detail.

rovers mission operations↗

Full wave modulator-demodulator amplifier apparatus

A full-wave modulator-demodulator apparatus is described including an operational amplifier having a first input terminal coupled to a circuit input terminal, and a second input terminal alternately coupled to the circuit input terminal. A circuit is ground by a switching circuit responsive to a phase reference signal and the operational amplifier is alternately switched between a non-inverting mode and an inverting mode. The switching circuit includes three field-effect transistors operatively associated to provide the desired switching function in response to an alternating reference signal of the same frequency as an AC input signal applied to the circuit input terminal.

Black, J. M.↗

Coupled Geomechanical Modeling to Assess Cap Rock Integrity and Mechanical Fault Stability: Application to Farnsworth Field Unit Project

Abstract The SWP project is located in a mature waterflood undergoing conversion to CO2-WAG operations in the Farnsworth, Texas, USA. Anthropogenic CO2 is sourced from a fertilizer and an ethanol plant. This work utilizes Farnsworth’s full-field, history-matched, compositional hydrodynamic coupled geomechanical model for assessing the impact of stress changes observed through the history matched field life. Production and injection induced stress changes, fault stability and caprock integrity investigations are performed to project the potential for fault reactivation and the loss of caprock integrity under shear failure. A static mechanical earth model (MEM) was constructed for use in transient coupled geomechanical model based on the existing Southwest Regional Partnership (SWP) geological model. The static MEM inherits the stratigraphic and structural features of the geologic model and incorporates additional overburden, underburden, and sideburden formations required to impose mechanical boundary conditions. Mechanical properties were distributed in the 3D MEM through integration of geophysical logs and 3-dimensional seismic elastic inversion properties using a combination of Bayesian and stochastic interpolation methods. These data are further enhanced by lab derived strength and failure criteria for the caprock interval. Additionally, interpreted faults and other geological features were included as part of the static structural framework to fully represent subsurface hydraulic and mechanical systems and appropriately integrate heterogeneity. Two-way coupling of hydrodynamic flow and geomechanical simulations incorporates the Kozeny-Carman relationship for updating permeability and is history matched through primary, secondary (waterflooding) and tertiary (CO2 WAG) recovery periods before performing a twenty year forecast. Two-way simulations are performed to understand the effective stress perturbations imposed by field operations: water injection and the more recent implementation of WAG. Evaluation of Mohr circles with liquid production and field pressure charts as well as slip tendency and distance to failure metrics indicate that neither our faults or cap rock are critically stressed. This paper presents the results of the Farnsworth initial attempts to integrate the seismic driven 3D MEM into coupled hydrodynamic geomechanical history match simulation workflow.

02 PETROLEUM↗

Lepton flavor violation by three units

The conservation of lepton flavor is a prediction of the Standard Model and is still an excellent approximate symmetry despite our observation of neutrino oscillations. Lepton flavor violation by one or two units has been discussed for decades, with several dedicated experiments exploring the vast model landscape but no discoveries so far. Here, we explore operators and processes that violate at least one lepton flavor by three units and identify testable signatures. In the Standard Model effective field theory, such operators already arise at mass dimension 7 and can be tested through their contributions to Michel parameters in leptonic decays. True neutrinoless charged-lepton flavor violation arises at mass dimension 10 and can realistically only be seen in the tau decay channels 𝜏 → $𝑒⁢𝑒⁢𝑒⁢\bar{𝜇}⁢\bar{𝜇}$ or 𝜏 → $𝜇⁢𝜇⁢𝜇\bar{𝑒}\bar{𝑒}$, for example in Belle II. Testable rates for these tau decays require light new particles and subsequently predict an avalanche of remarkably clean but so-far unconstrained collider signatures.

Feynman diagrams↗

A Wireless Underground Sensor Network Field Pilot for Agriculture and Ecology: Soil Moisture Mapping Using Signal Attenuation

Wireless Underground Sensor Networks (WUSNs) that collect geospatial in situ sensor data are a backbone of internet-of-things (IoT) applications for agriculture and terrestrial ecology. In this paper, we first show how WUSNs can operate reliably under field conditions year-round and at the same time be used for determining and mapping soil conditions from the buried sensor nodes. We demonstrate the design and deployment of a 23-node WUSN installed at an agricultural field site that covers an area with a 530 m radius. The WUSN has continuously operated since September 2019, enabling real-time monitoring of soil volumetric water content (VWC), soil temperature (ST), and soil electrical conductivity. Secondly, we present data collected over a nine-month period across three seasons. We evaluate the performance of a deep learning algorithm in predicting soil VWC using various combinations of the received signal strength (RSSI) from each buried wireless node, above-ground pathloss, the distance between wireless node and receive antenna (D), ST, air temperature (AT), relative humidity (RH), and precipitation as input parameters to the model. The AT, RH, and precipitation were obtained from a nearby weather station. We find that a model with RSSI, D, AT, ST, and RH as inputs was able to predict soil VWC with an R 2 of 0.82 for test datasets, with a Root Mean Square Error of ±0.012 (m 3 /m 3 ). Hence, a combination of deep learning and other easily available soil and climatic parameters can be a viable candidate for replacing expensive soil VWC sensors in WUSNs.

47 OTHER INSTRUMENTATION↗

Heat pump concepts for nZEB Technology developments, design tools and testing of heat pump systems for nZEB in the USA: Country report IEA HPT Annex 40 Task 2, Task 3 and Task 4 of the USA

The IEA HPT Annex 40 "Heat pump concepts for Nearly Zero Energy Buildings" deals with the application of heat pumps as a core component of the HVAC system for Nearly or Net Zero energy buildings (nZEB). This report covers Task 2 on the system comparison and optimisation and Task 3 dedicated to the development of adapted technologies for nZEB and field monitoring results of heat pump systems in nZEB. In the US team three institutions are involved and have worked on the following projects: The Oak Ridge National Laboratory (ORNL) will summarize development activities through the field demonstration stage for several integrated heat pump (IHP) systems electric ground-source (GS-IHP) and air-source (AS-IHP) versions and an engine driven AS-IHP version. The first commercial GS-IHP product was just introduced to the market in December 2012. This work is a contribution to Task 3 of the Annex. The University of Maryland will contribute a software development project to Task 2 of the Annex. The software ThermCom evaluates occupied space thermal comfort conditions accounting for all radiative and convective heat transfer effects as well as local air properties. The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net Zero Energy Residential Test Facility (NZERTF). This residential building was constructed on the NIST campus and officially opened in summer 2013. During the first year, between July 2013 and June 2014, baseline performance of the NZERTF was monitored under a simulated occupancy protocol. The house was equipped with an air-to-air heat pump which included a dedicated dehumidification operating mode. Outdoor conditions, internal loads and modes of heat pump operation were monitored. Field study results with respect to heat pump operation will be reported and recommendations on heat pump optimization for a net zero energy building will be provided. This work is a contribution to Task 3 of the Annex.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NASA Desert RATS 2010: Preliminary Results for Science Operations Conducted in the San Francisco Volcanic Field, Arizona

The National Aeronautics and Space Administration (NASA) is working with international partners to develop the space architectures and mission plans necessary for human spaceflight beyond earth orbit. These mission plans include the exploration of planetary surfaces with significant gravity fields. The Apollo missions to the Moon demonstrated conclusively that surface mobility is a key asset that improves the efficiency of human explorers on a planetary surface. NASA's Desert Research and Technology Studies (Desert RATS) is a multi-year series tests of hardware and operations carried out annually in the high desert of Arizona. Conducted since 1998, these activities are designed to exercise planetary surface hardware and operations in relatively harsh climatic conditions where long-distance, multi-day roving is achievable

Gruener, J. E.↗

Effective Field Theory and Time-Reversal Violation in Light Nuclei

Thanks to the unnaturally small value of the QCD vacuum angle θ¯ ≲ 10 -10 , time–reversal violation offers a window into physics beyond the Standard Model (SM) of particle physics. We review the effective field theory framework that establishes a clean connection between (a) time–reversal violation mechanisms, which can be represented by higher-dimensional operators involving SM fields and symmetries, and (b) hadronic interactions, which allow for controlled calculations of low-energy observables involving strong interactions. The chiral properties of time–reversal violation mechanisms lead to a pattern that should be identifiable in measurements of the electric dipole moments of the nucleon and light nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling CO 2 Sequestration in Saline Aquifer and Depleted Oil Reservoir To Evaluate Regional CO 2 Sequestration Potential of Ozark Plateau Aquifer System, South-Central Kansas

1. Drilled, cored, and logged three wells to the basement and collecting more than 2,700 ft of conventional core; obtained 20 m i2 of multicomponent 3D seismic imaging and merged and reprocessed more than 125 mi 2 of existing 3D seismic data for use in modeling CO 2 - EOR oil recovery and CO 2 storage in five oil fields in southern Kansas. 2. Determined the technical feasibility of injecting and sequestering CO 2 in a set of four depleted oil reservoirs in the Cutter, Pleasant Prairie South, Eubank, and Shuck fields in southwest Kansas; of concurrently recovering oil from those fields; and of quantifying the volumes of CO2 sequestered and oil recovered during the process. 3. Formed a consortium of six oil operating companies, five of which own and operate the four fields. The consortium became part of the Southwest Kansas CO 2 -EOR Initiative for the purpose of sharing data, knowledge, and interest in understanding the potential for CO 2 -EOR in Kansas. 4. Built a regional well database covering 30,000 mi 2 and containing stratigraphic tops from ~90,000 wells; correlated 30 major stratigraphic horizons; digitized key wells, including wireline logs and sample logs; and analyzed more than 3,000 drill stem tests to establish that fluid levels in deep aquifers below the Permian evaporites are not connected to the surface and therefore pressures are not hydrostatic. Connectivity with the surface aquifers is lacking because shale aquitards and impermeable evaporite layers consist of both halite and anhydrite. 5. Developed extensive web applications and an interactive mapping system that do the following: a. Facilitate access to a wide array of data obtained in the study, including core descriptions and analyses, sample logs, digital (LAS) well logs, seismic data, gravity and magnetics maps, structural and stratigraphic maps, inferred fault traces, earthquakes, Class I and II disposal wells, and surface lineaments. b. Provide real-time analysis of the project dataset, including automated integration and viewing of well logs, core, core analyses, brine chemistry, and stratigraphy using the Java Profile app. A cross-section app allows for the display of log data for up to four wells at a time. 6. Integrated interpretations from the project’s interactive web-based mapping system to gain insights to aid in assessing the efficacy of geologic CO 2 storage in Kansas and insights toward understanding recent seismicity to aid in evaluating induced vs. naturally occurring earthquakes. 7. Developed a digital type-log system, including web-based software to modify and refine stratigraphic nomenclature to provide stakeholders a common means for communication about the subsurface. 8. Contracted use of a nuclear magnetic resonance (NMR) log and ran it slowly to capture response and characterize larger pores common for carbonate reservoirs. Used NMR to extend core analyses to apply permeability, relative permeability to CO 2 , and capillary pressure to the major rock types, each uniquely expressed as a reservoir quality index (RQI), present in the Mississippian and Arbuckle rocks. 9. Characterized and evaluated the possible role of microbes in dense brines. Used microbes to compliment H/O stable isotopes to fingerprint brine systems. Used perforation/swabbing to obtain samples from multiple hydrostratigraphic units and confirmed equivalent results using less expensive drill stem tests (DST). 10. Used an integrated approach from whole core, logs, tests, and seismic to verify and quantify properties of vuggy, brecciated, and fractured carbonate intervals. 11. Used complex geocellular static and dynamic models to evaluate regional storage capacity using large parallel processing. 12. Carbonates are complex reservoirs and CO 2 -EOR needs to move to the next generation to increase effectiveness of CO 2 and efficiency and safety of the injection.

54 ENVIRONMENTAL SCIENCES↗

Modeling CO 2 Sequestration in Saline Aquifer and Depleted Oil Reservoir To Evaluate Regional CO 2 Sequestration Potential of Ozark Plateau Aquifer System, South-Central Kansas

1. Drilled, cored, and logged three wells to the basement and collecting more than 2,700 ft of conventional core; obtained 20 m i2 of multicomponent 3D seismic imaging and merged and reprocessed more than 125 mi 2 of existing 3D seismic data for use in modeling CO 2 - EOR oil recovery and CO 2 storage in five oil fields in southern Kansas. 2. Determined the technical feasibility of injecting and sequestering CO 2 in a set of four depleted oil reservoirs in the Cutter, Pleasant Prairie South, Eubank, and Shuck fields in southwest Kansas; of concurrently recovering oil from those fields; and of quantifying the volumes of CO2 sequestered and oil recovered during the process. 3. Formed a consortium of six oil operating companies, five of which own and operate the four fields. The consortium became part of the Southwest Kansas CO 2 -EOR Initiative for the purpose of sharing data, knowledge, and interest in understanding the potential for CO 2 -EOR in Kansas. 4. Built a regional well database covering 30,000 mi 2 and containing stratigraphic tops from ~90,000 wells; correlated 30 major stratigraphic horizons; digitized key wells, including wireline logs and sample logs; and analyzed more than 3,000 drill stem tests to establish that fluid levels in deep aquifers below the Permian evaporites are not connected to the surface and therefore pressures are not hydrostatic. Connectivity with the surface aquifers is lacking because shale aquitards and impermeable evaporite layers consist of both halite and anhydrite. 5. Developed extensive web applications and an interactive mapping system that do the following: a. Facilitate access to a wide array of data obtained in the study, including core descriptions and analyses, sample logs, digital (LAS) well logs, seismic data, gravity and magnetics maps, structural and stratigraphic maps, inferred fault traces, earthquakes, Class I and II disposal wells, and surface lineaments. b. Provide real-time analysis of the project dataset, including automated integration and viewing of well logs, core, core analyses, brine chemistry, and stratigraphy using the Java Profile app. A cross-section app allows for the display of log data for up to four wells at a time. 6. Integrated interpretations from the project’s interactive web-based mapping system to gain insights to aid in assessing the efficacy of geologic CO 2 storage in Kansas and insights toward understanding recent seismicity to aid in evaluating induced vs. naturally occurring earthquakes. 7. Developed a digital type-log system, including web-based software to modify and refine stratigraphic nomenclature to provide stakeholders a common means for communication about the subsurface. 8. Contracted use of a nuclear magnetic resonance (NMR) log and ran it slowly to capture response and characterize larger pores common for carbonate reservoirs. Used NMR to extend core analyses to apply permeability, relative permeability to CO 2 , and capillary pressure to the major rock types, each uniquely expressed as a reservoir quality index (RQI), present in the Mississippian and Arbuckle rocks. 9. Characterized and evaluated the possible role of microbes in dense brines. Used microbes to compliment H/O stable isotopes to fingerprint brine systems. Used perforation/swabbing to obtain samples from multiple hydrostratigraphic units and confirmed equivalent results using less expensive drill stem tests (DST). 10. Used an integrated approach from whole core, logs, tests, and seismic to verify and quantify properties of vuggy, brecciated, and fractured carbonate intervals. 11. Used complex geocellular static and dynamic models to evaluate regional storage capacity using large parallel processing. 12. Carbonates are complex reservoirs and CO 2 -EOR needs to move to the next generation to increase effectiveness of CO 2 and efficiency and safety of the injection.

54 ENVIRONMENTAL SCIENCES↗

Modeling CO 2 Sequestration in Saline Aquifer and Depleted Oil Reservoir To Evaluate Regional CO 2 Sequestration Potential of Ozark Plateau Aquifer System, South-Central Kansas

1. Drilled, cored, and logged three wells to the basement and collecting more than 2,700 ft of conventional core; obtained 20 m i2 of multicomponent 3D seismic imaging and merged and reprocessed more than 125 mi 2 of existing 3D seismic data for use in modeling CO 2 - EOR oil recovery and CO 2 storage in five oil fields in southern Kansas. 2. Determined the technical feasibility of injecting and sequestering CO 2 in a set of four depleted oil reservoirs in the Cutter, Pleasant Prairie South, Eubank, and Shuck fields in southwest Kansas; of concurrently recovering oil from those fields; and of quantifying the volumes of CO2 sequestered and oil recovered during the process. 3. Formed a consortium of six oil operating companies, five of which own and operate the four fields. The consortium became part of the Southwest Kansas CO 2 -EOR Initiative for the purpose of sharing data, knowledge, and interest in understanding the potential for CO 2 -EOR in Kansas. 4. Built a regional well database covering 30,000 mi 2 and containing stratigraphic tops from ~90,000 wells; correlated 30 major stratigraphic horizons; digitized key wells, including wireline logs and sample logs; and analyzed more than 3,000 drill stem tests to establish that fluid levels in deep aquifers below the Permian evaporites are not connected to the surface and therefore pressures are not hydrostatic. Connectivity with the surface aquifers is lacking because shale aquitards and impermeable evaporite layers consist of both halite and anhydrite. 5. Developed extensive web applications and an interactive mapping system that do the following: a. Facilitate access to a wide array of data obtained in the study, including core descriptions and analyses, sample logs, digital (LAS) well logs, seismic data, gravity and magnetics maps, structural and stratigraphic maps, inferred fault traces, earthquakes, Class I and II disposal wells, and surface lineaments. b. Provide real-time analysis of the project dataset, including automated integration and viewing of well logs, core, core analyses, brine chemistry, and stratigraphy using the Java Profile app. A cross-section app allows for the display of log data for up to four wells at a time. 6. Integrated interpretations from the project’s interactive web-based mapping system to gain insights to aid in assessing the efficacy of geologic CO 2 storage in Kansas and insights toward understanding recent seismicity to aid in evaluating induced vs. naturally occurring earthquakes. 7. Developed a digital type-log system, including web-based software to modify and refine stratigraphic nomenclature to provide stakeholders a common means for communication about the subsurface. 8. Contracted use of a nuclear magnetic resonance (NMR) log and ran it slowly to capture response and characterize larger pores common for carbonate reservoirs. Used NMR to extend core analyses to apply permeability, relative permeability to CO 2 , and capillary pressure to the major rock types, each uniquely expressed as a reservoir quality index (RQI), present in the Mississippian and Arbuckle rocks. 9. Characterized and evaluated the possible role of microbes in dense brines. Used microbes to compliment H/O stable isotopes to fingerprint brine systems. Used perforation/swabbing to obtain samples from multiple hydrostratigraphic units and confirmed equivalent results using less expensive drill stem tests (DST). 10. Used an integrated approach from whole core, logs, tests, and seismic to verify and quantify properties of vuggy, brecciated, and fractured carbonate intervals. 11. Used complex geocellular static and dynamic models to evaluate regional storage capacity using large parallel processing. 12. Carbonates are complex reservoirs and CO 2 -EOR needs to move to the next generation to increase effectiveness of CO 2 and efficiency and safety of the injection.

54 ENVIRONMENTAL SCIENCES↗