Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Storage Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Liquefied gas electrolytes for electrochemical energy storage devices

Electrochemical capacitors and lithium-ion batteries have seen little change in their electrolyte chemistry since their commercialization, which has limited improvements in device performance. Combining superior physical and chemical properties and a high dielectric-fluidity factor, the use of electrolytes based on solvent systems that exclusively use components that are typically gaseous under standard conditions show a wide potential window of stability and excellent performance over an extended temperature range. Electrochemical capacitors using difluoromethane show outstanding performance from –78° to +65°C, with an increased operation voltage. The use of fluoromethane shows a high coulombic efficiency of ~97% for cycling lithium metal anodes, together with good cyclability of a 4-volt lithium cobalt oxide cathode and operation as low as –60°C, with excellent capacity retention.

Science & Technology - Other Topics↗

Performance and Reliability Advancements in a Durable Low Temperature Tubular SOFC

The key objective of this program was to develop, build and test an ultra-low degradation, high efficiency SOFC stack with a novel capability for energy storage. The demonstration would be a step toward MW systems but a successful prototype leads to revolutionize our future system designs, significantly reducing the cost and extending the capability of the SOFC in energy harvesting projects. To achieve these innovative goals, advancements in cell and stack technology as well as manufacturing technology and automation were undertaken. The major tasks in cell and stack technology included: 1. The incorporation of an inexpensive solid fuel element in each cell to provide protection against overloading and enable storage inside the fuel cell 2. Increasing efficiency without water recirculation using novel integral POX reforming 3. Reduced stack degradation through tried and true electrode material augmentations for intermediate temperature cell operation In order to ensure that the technology can be accepted by the largest market, manufacturing costs were also addressed for targeting cost and reliability as outlined below: 1. Thinner tube by isostatic pressing automation 2. Electrode impregnation automation 3. Stack manufacturing improvements Atrex Energy has successfully developed and demonstrated the advanced Solid Oxide Fuel Cell (SOFC) technology through this program. R&D efforts have demonstrated the ability to operate SOFCs under sub-stoichiometric partial oxidation air-to-fuel ratios while showing significant resiliency against high fuel utilizations approaching 120%. Core fuel cell innovations including manufacturing advancements enabled Atrex to develop and demonstrate a cost effective, durable 5KW SOFC stack operating on natural gas at net fuel-to-DC electricity efficiencies of ~50 % while operating at a nominal temperature of 650 deg C.

03 NATURAL GAS↗

High power and high energy electrodes using carbon nanotubes

An electrode useful in an energy storage system, such as a capacitor, includes an electrode that includes at least one to a plurality of layers of compressed carbon nanotube aggregate. Methods of fabrication are provided. The resulting electrode exhibits superior electrical performance in terms of gravimetric and volumetric power density.

25 ENERGY STORAGE↗

Status Update on the High Precision Isotopic Measurements on High Burnup LWR Fuel in 2020

The US Department of Energy (DOE) Office of Nuclear Energy (NE) is currently investigating the feasibility of directly disposing dual-purpose (storage and transportation) canisters (DPCs) in a spent nuclear fuel (SNF) repository. Criticality during the repository performance period (10,000 years or more) is one of the major concerns related to direct disposal of DPCs, specifically as the system undergoes degradation in the repository environment and timeframe. Oak Ridge National Laboratory (ORNL) is developing an as-loaded criticality analysis methodology using full (actinides + fission products) burnup credit that exploits the inherent criticality margin associated with actual canister-specific loading configuration. Burnup credit criticality analysis requires validation of the depletion/decay codes used to generate the burned isotopic inventory of an assembly by comparing the code-predicted inventory with experimentally determined isotopic data. Currently, isotopic measurement data for boiling water reactors (BWR) SNF are limited, and additional measurements will be highly beneficial for BWR burnup credit analysis, which is essential to demonstrate disposability of BWR DPCs. Moreover, new pressurized water reactor (PWR) samples of isotopic measurements will expand the PWR sample population and consequently will greatly improve sample statistics. In turn, this will reduce uncertainty in the computational determination of the isotopic composition of commercial SNF and eliminate additional penalties currently used for lack of data. As part of the isotopic analysis task, eight diverse, high burnup (HBU) samples from several PWR rods are being dissolved and isotopically analyzed to provide high-quality measurement data for PWR SNF to reducing the uncertainties associated with PWR isotopic depletion validation. The isotopics of interest focus on nuclides important to burnup credit, shielding, and decay heat in PWR SNF. Additionally, eight high burnup BWR fuel samples from the Limerick nuclear power plant have been identified for measurement to support reducing uncertainties associated with BWR isotopic depletion validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operando X-ray imaging reveals size-dependent evolution of cobalt oxide thermochemical material during thermal redox cycles

Multivalent metal oxides are promising thermochemical materials (TCMs) for energy storage and conversion owing to their high energy density, air compatibility, and high-temperature stability. Co 3 O 4 serves as a model system for examining particle-size- and structure-dependent redox behavior. While particle size and porosity are known to affect performance, their interplay and the kinetics of pore formation during cycling remain unclear. Here we show the chemical and 3D morphological evolution of Co 3 O 4 micro- and nanoparticles during redox cycles at 800–900 °C using thermal analysis, in-situ synchrotron transmission X-ray microscopy (TXM), and scanning electron microscopy. Thermal analysis shows that nanoparticles re-oxidize more rapidly than microparticles at 800 °C. In-situ nanotomography and chemical imaging reveals that nanoparticles undergo redox conversion without forming internal pores, whereas microparticles develop isolated porosity during reduction. These pores persist through re-oxidation, correlating to a lower conversion rate in subsequent cycles. Our results demonstrate distinct degradation kinetics in Co 3 O 4 micro- and nanoparticles, underscoring the critical role of particle size and porosity in redox performance and informing strategies to enhance the long-term efficiency of metal oxide TCMs.

25 ENERGY STORAGE↗

System Design of a 2.0 MWth Sodium/Molten Salt Pilot System

Nitrate molten salt concentrating solar power (CSP) systems are currently deployed globally and are considered state-of the art heat transfer fluids (HTFs) for present day high-temperature operation. Although slightly higher limits may be possible with molten salt, to fully realize SunShot efficiency goals of $15/kWhth HTFs and an LCOE of 6¢/kWh, HTF technologies working at higher temperatures (e.g., 650 °C to 750 °C) will require an alternative to molten salts, such as with alkali metal systems. This investigation explores the development of a 2.0 MWth sodium receiver system that employs a sodium receiver as the HTF, as well as with a ternary chloride (20%NaCl/40%MgCl/40%KCl by mol wt.%) salt as a thermal energy storage (TES) medium to facilitate a 6-hr. storage duration. A sodium-to-salt heat exchanger model as well as a salt-to-sCO2 primary heat exchanger model are employed and evaluated in this investigation. A thermodynamic system design model was developed using Engineering Equation Solver (EES) where state properties were calculated at inlets and outlets along both hot and cold legs of the pilot-scale plant. This investigation assesses receiver performance as well as system efficiency studies for the pump and system operational ranges. Results found that high efficiency sodium receivers were found to have higher heat transfer coefficients and required far less spreading of incident flux. The system performance model results suggest that for a pump speed of 2400 RPM, respective hot and cold pump TDH values were determined to be 260.1–307 ft. and 260.1–307 ft for pump flow rates of 90–120 GPM.

41 EE - Solar Energy Technologies Office (EE-4S)↗

An Optimized Input/Output-Constrained Control Design With Application to Microgrid Operation

In this paper, a nonlinear control design is presented for systems whose input and output vectors are saturated. The proposed synthesis includes an optimal tracker as the seed controller and explicitly imposes all the relevant constraints on system input, on the rate of change in the input, and on system output by using the tools of barrier functions, input-output feedback linearization, comparison argument, Lyapunov argument, and a real-time constrained optimization. The proposed design is applied to microgrid operation with high penetration of renewable generation, where net load and variable generation must be balanced and the microgrid should be operated at an optimal or near-optimal performance level. Since traditional generation has a limited ramping rate, battery storage devices and demand responses become necessary to effectively deal with variability of renewable generation and to maintain frequency stability, but their capacities are also limited. Finally,it is shown that the proposed design is effective for coordinated control of traditional generation, storage and demand response so that the power system frequency is guaranteed to be within the required operational limits and that renewable curtailment is eliminated or minimized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lignin-derived electrochemical energy materials and systems

Electrochemical energy storage systems such as supercapacitors, rechargeable batteries and fuel cells have been proven the most effective technologies for energy conversion, storage, and management at different scales. Although a large number of electrochemical energy technologies have been developed in the past and they will continue to be optimized in terms of cost, lifetime, and performance, there is a substantial growing demand for advanced electrochemical energy systems. To deploy these advanced systems, the electrode and electrolyte materials with higher performance, longer life, and lower cost, must be developed. Lignin is the second most abundant natural polymer after cellulose, a byproduct from emerging cellulosic biorefineries, and a waste product from pulp and paper industries. Numerous researches have successfully demonstrated that lignin from different sources can be used as precursors or feedstocks for preparing high-performance electrochemical energy materials and components such as electrodes, electrolytes, membrane separators, and additives. Moreover, techno-economic analyses indicate that it is possible to prepare cost-effective carbons from lignin at engineering scales, compared to current carbon products. These facts suggest that scalable conversion of lignin into high-value energy materials will offer a promising pathway to not only promote the utilization and valorization of lignin but also boost the development of the advanced electrochemical energy systems. This review presents state of the arts of renewable energy materials derived from various lignin and their applications in electrochemical energy systems with emphasis on supercapacitors, rechargeable batteries, and fuel cells. Meanwhile, this article also aims to carve out the critical barriers for lignin-derived high-performance materials for energy applications, intending to identify viable approaches for synthesis of sustainable new energy materials.

09 BIOMASS FUELS↗

Nuclear Energy Advanced Modeling and Simulation (NEAMS) waste Integrated Performance and Safety Codes (IPSC) : gap analysis for high fidelity and performance assessment code development.

This report describes a gap analysis performed in the process of developing the Waste Integrated Performance and Safety Codes (IPSC) in support of the U.S. Department of Energy (DOE) Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) Campaign. The goal of the Waste IPSC is to develop an integrated suite of computational modeling and simulation capabilities to quantitatively assess the long-term performance of waste forms in the engineered and geologic environments of a radioactive waste storage or disposal system. The Waste IPSC will provide this simulation capability (1) for a range of disposal concepts, waste form types, engineered repository designs, and geologic settings, (2) for a range of time scales and distances, (3) with appropriate consideration of the inherent uncertainties, and (4) in accordance with rigorous verification, validation, and software quality requirements. The gap analyses documented in this report were are performed during an initial gap analysis to identify candidate codes and tools to support the development and integration of the Waste IPSC, and during follow-on activities that delved into more detailed assessments of the various codes that were acquired, studied, and tested. The current Waste IPSC strategy is to acquire and integrate the necessary Waste IPSC capabilities wherever feasible, and develop only those capabilities that cannot be acquired or suitably integrated, verified, or validated. The gap analysis indicates that significant capabilities may already exist in the existing THC codes although there is no single code able to fully account for all physical and chemical processes involved in a waste disposal system. Large gaps exist in modeling chemical processes and their couplings with other processes. The coupling of chemical processes with flow transport and mechanical deformation remains challenging. The data for extreme environments (e.g., for elevated temperature and high ionic strength media) that are needed for repository modeling are severely lacking. In addition, most of existing reactive transport codes were developed for non-radioactive contaminants, and they need to be adapted to account for radionuclide decay and in-growth. The accessibility to the source codes is generally limited. Because the problems of interest for the Waste IPSC are likely to result in relatively large computational models, a compact memory-usage footprint and a fast/robust solution procedure will be needed. A robust massively parallel processing (MPP) capability will also be required to provide reasonable turnaround times on the analyses that will be performed with the code. A performance assessment (PA) calculation for a waste disposal system generally requires a large number (hundreds to thousands) of model simulations to quantify the effect of model parameter uncertainties on the predicted repository performance. A set of codes for a PA calculation must be sufficiently robust and fast in terms of code execution. A PA system as a whole must be able to provide multiple alternative models for a specific set of physical/chemical processes, so that the users can choose various levels of modeling complexity based on their modeling needs. This requires PA codes, preferably, to be highly modularized. Most of the existing codes have difficulties meeting these requirements. Based on the gap analysis results, we have made the following recommendations for the code selection and code development for the NEAMS waste IPSC: (1) build fully coupled high-fidelity THCMBR codes using the existing SIERRA codes (e.g., ARIA and ADAGIO) and platform, (2) use DAKOTA to build an enhanced performance assessment system (EPAS), and build a modular code architecture and key code modules for performance assessments. The key chemical calculation modules will be built by expanding the existing CANTERA capabilities as well as by extracting useful components from other existing codes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of an Integrated Gasification Direct-Fired Supercritical CO2 Power Cycle

This presentation discusses development and performance results of a coal gasification system integrated with a direct-fired supercritical CO2 (sCO2) power cycle. In this plant, coal is first gasified and cleaned in order to avoid introducing sulfur and particulate matter into the sCO2 cycle, with the sCO2 cycle’s oxy-combustor burning the cleaned syngas with oxygen in a recycled sCO2 stream. The plant is inherently amenable to carbon capture and storage (CCS) processes, as it produces a high pressure exhaust stream that is largely comprised of CO2. The baseline direct sCO2 cycle performance is discussed and compared to IGCC and oxy-coal AUSC reference plants with CCS. The sensitivity of the sCO2 cycle’s performance to various operating parameters is also discussed, as well as the effect of various heat integration options on thermal efficiency, operability, and cost.

Shelton, Walter↗

Reversible Crosslinked Polymer Binder for Recyclable Lithium Sulfur Batteries with High Performance

Owing to the negative impact of the extensive utilization of batteries on the environment, sustainability of the cells needs to be included in the systemic research of batteries. In this work, a dissolvable ionic crosslinked polymer (DICP) is exploited as a binder for lithium–sulfur batteries by crosslinking the polyacrylic acid and polyethyleneimine through carboxy-amino ionic interaction. This interaction is pH-controlled, and therefore, the crosslinked binder network can be readily dissociated under basic conditions, providing a facile strategy enabling valuable components recycled through a convenient washing method. The sulfur cathode prepared using the recycled carbon–sulfur composite can deliver comparable capacity as that of fresh electrode. In addition, evidence from cell performance and characterizations, such as in situ X-ray absorption spectroscopy, in situ UV–visible spectroscopy, X-ray photoelectron spectroscopy, and density functional theory calculation, confirms that DICP is a more effective binder than its commercial counterpart on suppressing polysulfide dissolution in the electrolyte. Exploiting reversible crosslinked polymer binder for recyclable Li–S batteries with ameliorated electrochemical performance, this study illuminates sustainable development for large-scale energy storage systems.

36 MATERIALS SCIENCE↗

Performance and Durability of Proton Exchange Membrane Vapor-Fed Unitized Regenerative Fuel Cells

With a growing demand for electricity, clean hydrogen production and usage can be an asset not only to mitigate emissions but for long-term energy storage as well. Hydrogen gas, a high-density energy carrier, can be made through electrolysis in charging mode and generate electricity via a fuel cell in discharging mode in a unitized regenerative fuel cell (URFC). While URFCs reduce cost by combining the charging and discharging modes into a singular device, switching between modes becomes burdensome, and water management is a major challenge. One way to mitigate these issues is to operate the entire system in the vapor phase. Vapor-phase operation simplifies the physics of the system but will introduce losses within the system, primarily ohmic and mass transport during the charging mode. In this study, we explore the performance of a Proton-Exchange-Membrane (PEM)-URFC under vapor-phase conditions and the impact of different PEMs, feed gases, and relative humidity on the performance and durability. By tailoring operating conditions and membrane, the vapor-URFC achieves a roundtrip efficiency of 42% and a lifetime of 50,000 accelerated stress test cycles for fully humidified feeds. Discussion of vapor-URFC for energy storage and extensions to look at various applications shows the promise of this technology.

25 ENERGY STORAGE↗

Foresee: A user-centric home energy management system for energy efficiency and demand response

This paper presents foresee, a user-centric home energy management system that can help optimize how a home operates to concurrently meet users' needs, achieve energy efficiency and commensurate utility cost savings, and reliably deliver grid services based on utility signals. Foresee is built on a multiobjective model predictive control framework, wherein the objectives consist of energy cost, thermal comfort, user convenience, and carbon emission. Foresee learns user preferences on different objectives and acts on their behalf to operate building equipment, such as home appliances, photovoltaic systems, and battery storage. In this work, machine-learning algorithms were used to derive data-driven appliance models and usage patterns to predict the home's future energy consumption. This approach enables highly accurate predictions of comfort needs, energy costs, environmental impacts, and grid service availability. Simulation studies were performed on field data from a residential building stock data set collected in the Pacific Northwest. Results indicated that foresee generated up to 7.6% whole-home energy savings without requiring substantial behavioral changes. When responding to demand response events, foresee was able to provide load forecasts upon receipt of event notifications and delivered the committed demand response services with 10% or fewer errors. Foresee fully utilized the potential of the battery storage and controllable building loads and delivered up to 7.0-kW load reduction and 13.5-kW load increase. As a result, these benefits are provided while maintaining the occupants' thermal comfort or convenience in using their appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NASA Tech Briefs, July 2013

Dielectrophoresis-Based Particle Sensor Using Nanoelectrode Arrays; Multi-Dimensional Damage Detection for Surfaces and Structures; ULTRA: Underwater Localization for Transit and Reconnaissance Autonomy; Autonomous Cryogenic Leak Detector for Improving Launch Site Operations; Submillimeter Planetary Atmospheric Chemistry Exploration Sounder; Method for Reduction of Silver Biocide Plating on Metal Surfaces; Silicon Micromachined Microlens Array for THz Antennas; Forward-Looking IED Detector Ground Penetrating Radar; Fully Printed, Flexible, Phased Array Antenna for Lunar Surface Communication, Battery Charge Equalizer with Transformer Array; An Efficient, Highly Flexible Multi-Channel Digital Downconverter Architecture; Dimmable Electronic Ballast for a Gas Discharge Lamp; Conductive Carbon Nanotube Inks for Use with Desktop Inkjet Printing Technology; Enhanced Schapery Theory Software Development for Modeling Failure of Fiber-Reinforced Laminates; High-Performance, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants; Carbon Nanotube Microarrays Grown on Nanoflake Substrates; Differential Muon Tomography to Continuously Monitor Changes in the Composition of Subsurface Fluids; Microgravity Drill and Anchor System; 20 Granular Media-Based Tunable Passive Vibration Suppressor; 21 Miga Aero Actuator and 2D Machined Mechanical Binary Latch; Micro-XRF for In Situ Geological Exploration of Other Planets; Hydrogen-Enhanced Lunar Oxygen Extraction and Storage Using Only Solar Power; Uplift of Ionospheric Oxygen Ions During Extreme Magnetic Storms; Miniaturized, High-Speed, Modulated X-Ray Source; Hollow-Fiber Spacesuit Water Membrane Evaporator 25 High-Power Single-Mode 2.65-micrometers InGaAsSb/AlInGaAsSb Diode Lasers; Optical Device for Converting a Laser Beam Into Two Co-aligned but Oppositely Directed Beams; A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging; X-Ray Diffractive Optics; SynGenics Optimization System (SynOptSys); 29 CFD Script for Rapid TPS Damage Assessment; radEq Add-On Module for CFD Solver Loci-CHEM; Science Opportunity Analyzer (SOA) Version 8; 30 Autonomous Byte Stream Randomizer; Distributed Engine Control Empirical/Analytical Verification Tools; Dynamic Server-Based KML Code Generator Method for Level-of-Detail Traversal of Geospatial Data; Automated Planning of Science Products Based on Nadir Overflights and Alerts for Onboard and Ground Processing; Linked Autonomous Interplanetary Satellite Orbit Navigation; Risk-Constrained Dynamic Programming for Optimal Mars Entry, Descent, and Landing; Scheduling Operations for Massive Heterogeneous Clusters; Deepak Condenser Model (DeCoM); Flight Software Math Library; Recirculating 1-K-Pot for Pulse-Tube Cryostats; 35 Method for Processing Lunar Regolith Using Microwaves; Wells for In Situ Extraction of Volatiles from Regolith (WIEVR); and Estimating the Backup Reaction Wheel Orientation Using Reaction Wheel Spin Rates Flight Telemetry from a Spacecraft.

Source record↗

IN-SERVICE INSPECTION OF EXTENDED DRY STORAGE OF SPENT NUCLEAR FUEL, PART I: CRAWLER TECHNOLOGY DEVELOPMENT

This paper describes development and demonstration of remote crawling systems to support periodic examinations of interim dry storage system (DSS) canisters for spent nuclear fuel in the USA. Specifically, this work relates to robotic crawler developments for “canister” based DSS systems which form the majority population of DSSs, in the USA, for interim storage of spent nuclear fuel. Consideration of potential degradation of the welded stainless-steel canister in these systems is required for continued usage in the period of extended operation (PEO) beyond their initial licensed or certified terms. Challenges associated with performing the periodic examinations are associated with physical access to the canister surface which is constrained due to narrow annulus spaces between the canister and the overpack, tortuous entry pathways, and high temperatures and radiation doses that can be damaging to materials and electronics. Motivations for performing periodic examinations and developing robotic crawlers for performing those examinations remotely will be presented and several activities to demonstrate robotic crawlers for different DSS systems are summarized.

nondestructive examination (NDE), Dry Cask Storage↗

Failing in place for low-serviceability storage infrastructure using high-parity GPU-based RAID.

In order to provide large quantities of high-reliability disk-based storage, it has become necessary to aggregate disks into fault-tolerant groups based on the RAID methodology. Most RAID levels do provide some fault tolerance, but there are certain classes of applications that require increased levels of fault tolerance within an array. Some of these applications include embedded systems in harsh environments that have a low level of serviceability, or uninhabited data centers servicing cloud computing. When describing RAID reliability, the Mean Time To Data Loss (MTTDL) calculations will often assume that the time to replace a failed disk is relatively low, or even negligible compared to rebuild time. For platforms that are in remote areas collecting and processing data, it may be impossible to access the system to perform system maintenance for long periods. A disk may fail early in a platform's life, but not be replaceable for much longer than typical for RAID arrays. Service periods may be scheduled at intervals on the order of months, or the platform may not be serviced until the end of a mission in progress. Further, this platform may be subject to extreme conditions that can accelerate wear and tear on a disk, requiring even more protection from failures. We have created a high parity RAID implementation that uses a Graphics Processing Unit (GPU) to compute more than two blocks of parity information per stripe, allowing extra parity to eliminate or reduce the requirement for rebuilding data between service periods. While this type of controller is highly effective for RAID 6 systems, an important benefit is the ability to incorporate more parity into a RAID storage system. Such RAID levels, as yet unnamed, can tolerate the failure of three or more disks (depending on configuration) without data loss. While this RAID system certainly has applications in embedded systems running applications in the field, similar benefits can be obtained for servers that are engineered for storage density, with less regard for serviceability or maintainability. A storage brick can be designed to have a MTTDL that extends well beyond the useful lifetime of the hardware used, allowing the disk subsystem to require less service throughout the lifetime of a compute resource. This approach is similar to the Xiotech ISE. Such a design can be deliberately placed remotely (without frequent support) in order to provide colocation, or meet cost goals. For workloads where reliability is key, but conditions are sub-optimal for routine serviceability, a high-parity RAID can provide extra reliability in extraordinary situations. For example, for installations requiring very high Mean Time To Repair, the extra parity can eliminate certain problems with maintaining hot spares, increasing overall reliability. Furthermore, in situations where disk reliability is reduced because of harsh conditions, extra parity can guard against early data loss due to lowered Mean Time To Failure. If used through an iSCSI interface with a streaming workload, it is possible to gain all of these benefits without impacting performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fabrication of ultrathin solid electrolyte membranes of β-Li 3 PS 4 nanoflakes by evaporation-induced self-assembly for all-solid-state batteries

All-solid-state lithium batteries are attractive candidates for next-generation energy storage devices because of their anticipated high energy density and intrinsic safety. Owing to their excellent ionic conductivity and stability with metallic lithium anodes, nanostructured lithium thiophosphate solid electrolytes such as β-Li 3 PS 4 have found use in the fabrication of all-solid lithium batteries for large-scale energy storage systems. However, current methods for preparing air-sensitive solid electrolyte membranes of lithium thiophosphates can only generate thick membranes that compromise the battery's gravimetric/volumetric energy density and thus its rate performance. To overcome this limitation, the solid electrolyte's thickness needs to be effectively decreased to achieve ideal energy density and enhanced rate performance. In this paper, we show that the evaporation-induced self-assembly (EISA) technique produces ultrathin membranes of a lithium thiophosphate solid electrolyte with controllable thicknesses between 8 and 50 μm while maintaining the high ionic conductivity of β-Li 3 PS 4 and stability with metallic lithium anodes up to 5 V. Finally, it is clearly demonstrated that this facile EISA approach allows for the preparation of ultrathin lithium thiophosphate solid electrolyte membranes for all-solid-state batteries.

25 ENERGY STORAGE↗

Influence of Metal Identity on Light-Induced Switchable Adsorption in Azobenzene-Based Metal–Organic Frameworks

Energy-efficient capture and release of small gas molecules, particularly carbon dioxide (CO 2 ) and methane (CH 4 ), are of significant interest in academia and industry. Porous materials such as metal–organic frameworks (MOFs) have been extensively studied, as their ultrahigh porosities and tunability enable significant amounts of gas to be adsorbed while also allowing specific applications to be targeted. However, because of the microporous nature of MOFs, the gas adsorption performance is dominated by high uptake capacity at low pressures, limiting their application. Hence, methods involving stimuli-responsive materials, particularly light-induced switchable adsorption (LISA), offer a unique alternative to thermal methods. Here, we report the mechanism of a well-known LISA system, the azobenzene-based material PCN-250, for CO 2 and CH 4 adsorption. There is a noticeable difference in the LISA effect dependent on the metal cluster involved, with the most significant being PCN-250-Al, where the adsorption can change by 83.1% CH 4 and 56.1% CO 2 at 298 K and 1 bar and inducing volumetric storage changes of 36.2 and 33.9 cm 3 /cm 3 at 298 K between 5 and 85 bar (CH 4 ) and 2 and 9 bar (CO 2 ), respectively. Using UV light in both single-crystal X-ray diffraction and gas adsorption testing, we show that upon photoirradiation, the framework undergoes a “localized heating” phenomenon comparable to an increase of 130 K for PCN-250-Fe and improves the working capacity. Furthermore, this process functions because of the constrained nature of the ligand, preventing the typical trans-to-cis isomerization observed in free azobenzene. In addition, we observed that the degree of localized heating is highly dependent on the metal cluster involved, with the series of isostructural PCN-250 systems showing variable performance based upon the degree of interaction between the ligand and the metal center.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗