Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Temperature Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Passive Microwave Remote Sensing of Rainfall Considering the Effects of Wind and Nonprecipitating Clouds

It has long been shown both in theory and in observation that emission from rain drops in a raining cloud results in upwelling brightness temperature above that caused by the sea surface alone. High brightness temperatures at microwave frequencies (e.g. 37 and 19 GHz) have usually been quantitatively associated with rainfall using physical or statistical models. By comparing concurrent special sensor microwave/imager and radar data, however, we noticed many cases where there is no appreciable rainfall in a field of view (FOV) which exhibits high brightness temperature (T(sub B)) at 37 and 19 GHz. On the basis of calculations and past literature it is shown that such high brightness temperatures can be caused by nonprecipitating clouds and by wind. The effect of the wind is to create wave and high-emissivity foam on the sea surface. A model is developed to relate T(sub B) to the fractional coverage of rain, f, within a FOV. The parameters of the model are calibrated by fitting the model to the observed brightness temperature and fractional rain coverage data. The critical parameter of the model, T(sub B min.), which is the threshold brightness temperature for the presence of rain, depends on the strength of the storm. The strength of the storm is characterized by the fraction of the FOVs within a large area that have T(sub B) higher than 240 K, which is readily obtainable from satellite data alone. The instantaneous FOV rain rate R can then be obtained through the f approximately R relationship which is empirically derived using radar data. An algorithm has been proposed based on the T(sub B) approximately f and f approximately R relationship. Application of the algorithm to TOGA-COARE and Darwin storms results in reasonable instantaneous FOV rain estimate. When averaged over the entire radar scan, a more accurate and unbiased areal rain estimate can be achieved.

Qihang Li.↗

Liquid Metal Diagnostics

Liquid metal (LM) plasma-facing components (PFCs) (LM-PFCs) within next-generation fusion reactors are expected to enhance plasma confinement, facilitate tritium breeding, improve reactor thermal efficiency, and withstand large heat and particle fluxes better than solid components made from tungsten, molybdenum, or graphite. Some LM divertor concepts intended for long-pulse operation at >20 MW/m 2 incorporate thin (~1 cm), fast-moving (~5 to 10 m/s), free-surface flows. Such systems will require a range of diagnostics to monitor and control the velocity, flow depth, temperature, and impurity concentration of the LM. As such, this paper will highlight technologies developed for the fission and casting/metallurgical industries that can be adapted to meet the needs of LM-PFC research. This paper is divided into four major parts. The first part will look at noncontact flowmeter technologies that are suitable for high-temperature alkali metal systems. These technologies include rotating Lorentz-force flowmeters for bulk flow rate measurements and particle tracking techniques for surface velocity measurements. Second, this paper will detail the operation of a new inductive level sensor that can be used within free-surface LM-PFCs. This robust level sensor can be mounted below the substrate that supports the LM, so it is simple to install and is protected from the damaging conditions inside a fusion reactor. It has been shown that this level sensor can be calibrated using either numerical or experimental techniques. Third, distributed temperature sensors based on fiber-optic technologies will be discussed. This advanced measurement technique provides temperature data with high spatial resolution and has recently been successfully tested in LM systems. Last, diagnostics to measure impurity concentration, such as electrochemical cells, plugging meters, and spectroscopic systems, will be addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ceramic Strain Gages for Use at Temperatures up to 1500 Celsius

Indium-tin-oxide (ITO) thin film strain gages were successfully demonstrated at temperatures beyond 1500 C. High temperature static strain tests revealed that the piezoresistive response and electrical stability of the ceramic sensors depended on the thickness of the ITO films comprising the active strain elements. When 2.5 microns-thick ITO films were employed as the active strain elements, the piezoresistive response became unstable at temperatures above 1225 C. In contrast to this, ceramic sensors prepared with 5 microns-thick ITO were stable beyond 1430 C and sensors prepared with 8 microns-thick ITO survived more than 20 hr of operation at 1481 C. Very thick (10 microns) ITo strain gages were extremely stable and responsive at 1528 C. ESCA depth profiles confirmed that an interfacial reaction between the ITO strain gage and alumina substrate was responsible for the high temperature electrical stability observed. Similar improvements in high temperature stability were achieved by doping the active ITO strain elements with aluminum. Several Sic-Sic CMC constant strain beams were instrumented with ITO strain gages and delivered to NASA for testing. Due to the extreme surface roughness of the CMC substrates, new lithography techniques and surface preparation methods were developed. These techniques relied heavily on a combination of Sic and A12O3 cement layers to provide the necessary surface finish for efficient pattern transfer. Micro-contact printing using soft lithography and PDMS stamps was also used to successfully transfer the thin film strain gage patterns to the resist coated CMC substrates. This latter approach has considerable potential for transferring the thin film strain gage patterns to the extremely rough surfaces associated with the CMC's.

Gregory, Otto↗

Selective Sensors of Nitrogen Dioxide Based on Thin Tungsten Oxide Films under Optical Irradiation

It is shown that NO{sub 2} present in air, beginning at a concentration of 1 ppm, can be selectively detected by sensors based on Au/WO{sub 3}:Au thin films activated by laser diode radiation with maximum intensity at 400 nm instead of constant heating. The radiation-activated photodesorption reduces the time of sensor response to NO{sub 2}. A high humidity of air under conditions of room-temperature irradiation additionally increases the device sensitivity to NO{sub 2} due to the appearance of additional adsorption sites. The absence of a sensor response to reducing gases and varying oxygen concentration in the atmosphere is caused by the photodesorption of chemisorbed O{sub 2}{sup −} species during their interaction with holes generated in intrinsic optical transitions in the near-surface region of WO{sub 3} film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temperature-Sensitive Coating Sensor Based on Hematite

A temperature-sensitive coating, based on hematite (iron III oxide), has been developed to measure surface temperature using spectral techniques. The hematite powder is added to a binder that allows the mixture to be painted on the surface of a test specimen. The coating dynamically changes its relative spectral makeup or color with changes in temperature. The color changes from a reddish-brown appearance at room temperature (25 C) to a black-gray appearance at temperatures around 600 C. The color change is reversible and repeatable with temperature cycling from low to high and back to low temperatures. Detection of the spectral changes can be recorded by different sensors, including spectrometers, photodiodes, and cameras. Using a-priori information obtained through calibration experiments in known thermal environments, the color change can then be calibrated to yield accurate quantitative temperature information. Temperature information can be obtained at a point, or over an entire surface, depending on the type of equipment used for data acquisition. Because this innovation uses spectrophotometry principles of operation, rather than the current methods, which use photoluminescence principles, white light can be used for illumination rather than high-intensity short wavelength excitation. The generation of high-intensity white (or potentially filtered long wavelength light) is much easier, and is used more prevalently for photography and video technologies. In outdoor tests, the Sun can be used for short durations as an illumination source as long as the amplitude remains relatively constant. The reflected light is also much higher in intensity than the emitted light from the inefficient current methods. Having a much brighter surface allows a wider array of detection schemes and devices. Because color change is the principle of operation, the development of high-quality, lower-cost digital cameras can be used for detection, as opposed to the high-cost imagers needed for intensity measurements with the current methods. Alternative methods of detection are possible to increase the measurement sensitivity. For example, a monochrome camera can be used with an appropriate filter and a radiometric measurement of normalized intensity change that is proportional to the change coating temperature. Using different spectral regions yields different sensitivities and calibration curves for converting intensity change to temperature units. Alternatively, using a color camera, a ratio of the standard red, green, and blue outputs can be used as a self-referenced change. The blue region (less than 500 nm) does not change nearly as much as the red region (greater than 575 nm), so a ratio of color intensities will yield a calibrated temperature image. The new temperature sensor coating is easy to apply, is inexpensive, can contour complex shape surfaces, and can be a global surface measurement system based on spectrophotometry. The color change, or relative intensity change, at different colors makes the optical detection under white light illumination, and associated interpretation, much easier to measure and interpret than in the detection systems of the current methods.

Bencic, Timothy J.↗

High-Temperature Extensometry and PdCr Temperature-Compensated Wire Resistance Strain Gages Compared

A detailed experimental evaluation is underway at the NASA Lewis Research Center to compare and contrast the performance of the PdCr/Pt dual-element temperature-compensated wire resistance strain gage with that of conventional high-temperature extensometry. The advanced PdCr gage, developed by researchers at Lewis, exhibits desirable properties and a relatively small and repeatable apparent strain to 800 C. This gage represents a significant advance in technology because existing commercial resistance strain gages are not reliable for quasi-static strain measurements above approximately 400 C. Various thermal and mechanical loading spectra are being applied by a high-temperature thermomechanical uniaxial testing system to evaluate the two strain-measurement systems. This is being done not only to compare and contrast the two strain sensors, but also to investigate the applicability of the PdCr strain gage to the coupon-level specimen testing environment typically employed when the high-temperature mechanical behavior of structural materials is characterized. Strain measurement capabilities to 800 C are being investigated with a nickel-base superalloy, Inconel 100 (IN 100), substrate material and application to TMC's is being examined with the model system, SCS-6/Ti-15-3. Furthermore, two gage application techniques are being investigated in the comparison study: namely, flame-sprayed and spot welding.

Source record↗

High-Temperature Extensometry and PdCr Temperature-Compensated Wire Resistance Strain Gages Compared

A detailed experimental evaluation is underway at the NASA Lewis Research Center to compare and contrast the performance of the PdCr/Pt dual-element temperature-compensated wire resistance strain gage with that of conventional high-temperature extensometry. The advanced PdCr gage, developed by researchers at Lewis, exhibits desirable properties and a relatively small and repeatable apparent strain to 800 C. This gage represents a significant advance in technology because existing commercial resistance strain gages are not reliable for quasi-static strain measurements above approx. 400 C. Various thermal and mechanical loading spectra are being applied by a high-temperature thermomechanical uniaxial testing system to evaluate the two strain-measurement systems. This is being done not only to compare and contrast the two strain sensors, but also to investigate the applicability of the PdCr strain gage to the coupon-level specimen testing environment typically employed when the high-temperature mechanical behavior of structural materials is characterized. Strain measurement capabilities to 800 C are being investigated with a nickel-base superalloy, Inconel 100 (IN 100), substrate material and application to TMC's is being examined with the model system, SCS-6/Ti-15-3. Furthermore, two gage application techniques are being investigated in the comparison study: namely, flame-sprayed and spot welding. The apparent strain responses of both the weldable and flame-sprayed PdCr wire strain gages were found to be cyclically repeatable on both IN 100 and SCS-6/Ti-15-3 [0]_8. In general, each gage exhibited some uniqueness with respect to apparent strain behavior. Gages mounted on the IN 100 specimens tended to show a repeatable apparent strain within the first few cycles, because the thermal response of IN 100 was stable. This was not the case, however, for the TMC specimens, which typically required several thermal cycles to stabilize the thermal strain response. Thus, progressive changes in the apparent strain behavior were corroborated by the extensometer, which unlike the mounted gage can distinguish quantitative changes in the material's thermal strain response. One specimen was instrumented with both a fixed and floating gage. From the difference in output of these two gages, the thermal expansion strains were calculated. These data, which are given in the figure, show excellent agreement with the values measured by the high-temperature extensometry.

Source record↗

Calibration of Hot Wire Anemometers. (Latest Citations from the Aerospace Database)

The bibliography contains citations concerning calibration methods and measurement correction schemes for hot wire anemometers. Coverage includes static and dynamic calibration of sensors having single, multiple, cross, and ring wire configurations. Correction methods to account for yaw angle, low-velocity flow, microgravity, wall proximity, and highly fluctuating turbulence, velocity, or temperature are covered. Correction methods are also referenced for installations having multiple sensors. Hot film and laser anemometers, and the use of anemometers in specific industrial and aerospace applications are extensively covered in separate biblographies. (Contains 50-250 citations and includes a subject term index and title list.)

HOT WIRE ANEMOMETERS↗

Conducting polymer-based electrochemical sensors: Progress, challenges, and future perspectives

Conducting polymers are promising due to their unique properties, such as excellent electrical and optical properties, physical and chemical stability, high conductivity, and effective redox properties with high-temperature stability and biocompatibility. Due to these properties, conducting polymers are useful in diverse applications like sensors, batteries, oil industries, biosensors, biomedicines, catalysis, cancer treatment, etc. This review article aims to discuss the recent trends and analysis of conducting polymer-based electrochemical sensors in diverse areas with all required sensor characteristics, such as the derived limit of detection, utilized techniques for the sensing analysis and derived linear dynamic range with the stability of the sensors. Conducting polymers and their nanocomposites-based electrochemical sensors have demonstrated exceptional capabilities towards detecting various biomolecules, heavy metals, pesticides, and viruses like SARS-COV-2. Incorporation of redox mediators, use of conducting hydrogels, and molecular imprinting are promising strategies for better performance of the derived sensor. The article has demonstrated the existing challenges and limitations and provided solutions in the field. In the future, conducting polymers-based electrochemical sensors can be utilized in wearable sensors and integrated with IoT devices for better reach in real-time applications. They can also be made more accessible with precise control and data output by following specific methodologies. Utilizing green and sustainable conducting polymers can be crucial in advancing eco-friendly practices in the future. Conducting polymer-based electrochemical sensors has affectivity in neurochemical and pathogen sensing, which is essential for brain function and mental health.

42 ENGINEERING↗

High temperature skin friction measurement

Skin friction measurement in the NASA Langley hypersonic propulsion facility is described. The sensor configuration utilized an existing balance, modified to provide thermal isolation and an increased standoff distance. For test run times of about 20 sec and ambient-air cooling of the test section and balance, the modified balance performed satisfactorily, even when it was subjected to acoustic and structural vibration. The balance is an inertially balanced closed-loop servo system where the current to a moving-coil motor needed to restore or null the output from the position sensor is a measure of the force or skin friction tending to displace the moving element. The accuracy of the sensor is directly affected by the position sensor in the feedback loop, in this case a linear-variable differential transformer which has proven to be influenced by temperature gradients.

Tcheng, Ping↗

Ultra-sensitive Hall sensors based on graphene encapsulated in hexagonal boron nitride

The encapsulation of graphene in hexagonal boron nitride provides graphene on substrate with excellent material quality. Here, we present the fabrication and characterization of Hall sensor elements based on graphene boron nitride heterostructures, where we gain from high mobility and low charge carrier density at room temperature. We show a detailed device characterization including Hall effect measurements under vacuum and ambient conditions. We achieve a current- and voltage-related sensitivity of up to 5700 V/AT and 3 V/VT, respectively, outpacing state-of-the-art silicon and III/V Hall sensor devices. Finally, we extract a magnetic resolution limited by low frequency electric noise of less than 50 nT/√(Hz) making our graphene sensors highly interesting for industrial applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ocean Wave Studies with Applications to Ocean Modeling and Improvement of Satellite Altimeter Measurements

Combining analysis of satellite data (altimeter, scatterometer, high-resolution visible and infrared images, etc.) with mathematical modeling of non-linear wave processes, we investigate various ocean wave fields (on scales from capillary to planetary), their role in ocean dynamics and turbulent transport (of heat and biogeochemical quantities), and their effects on satellite altimeter measuring accuracy. In 1998 my attention was focused on long internal gravity waves (10 to 1000 km), known also as baroclinic inertia-gravity (BIG) waves. We found these waves to be a major factor of altimeter measurements "noise," resulting in a greater uncertainty [up to 10 cm in terms of sea surface height (SSH) amplitude] in the measured SSH signal than that caused by the sea state bias variations (up to 5 cm or so). This effect still remains largely overlooked by the satellite altimeter community. Our studies of BIG waves address not only their influence on altimeter measurements but also their role in global ocean dynamics and in transport and turbulent diffusion of biogeochemical quantities. In particular, in collaboration with Prof Peter Weichman, Caltech, we developed a theory of turbulent diffusion caused by wave motions of most general nature. Applied to the problem of horizontal turbulent diffusion in the ocean, the theory yielded the effective diffusion coefficient as a function of BIG wave parameters obtainable from satellite altimeter data. This effort, begun in 1997, has been successfully completed in 1998. We also developed a theory that relates spatial fluctuations of scalar fields (such as sea surface temperature, chlorophyll concentration, drifting ice concentration, etc.) to statistical characteristics of BIG waves obtainable from altimeter measurements. A manuscript is in the final stages of preparation. In order to verify the theoretical predictions and apply them to observations, we are now analyzing Sea-viewing Wide Field of view Sensor (SeaWiFS) and Field of view Sensor (SeaWiFS) and Advanced Very High-Resolution Radiometer (AVHRR) data on sea surface temperature (SST) and chlorophyll concentration jointly with TOPEX/POSEIDON data on SSH variations.

Glazman, Roman E.↗

Liquid Bismuth Propellant Flow Sensor

Quantifying the propellant mass flow rate in liquid bismuth-fed electric propulsion systems has two challenging facets. First, the flow sensors must be capable of providing a resolvable measurement at propellant mass flow rates on the order of 10 mg/see with and uncertainty of less that 5%. The second challenge has to do with the fact that the materials from which the flow sensors are fabricated must be capable of resisting any of the corrosive effects associated with the high-temperature propellant. The measurement itself is necessary in order to properly assess the performance (thrust efficiency, Isp) of thruster systems in the laboratory environment. The hotspot sensor[I] has been designed to provide the bismuth propellant mass flow rate measurement. In the hotspot sensor, a pulse of thermal energy (derived from a current pulse and associated joule heating) is applied near the inlet of the sensor. The flow is "tagged" with a thermal feature that is convected downstream by the flowing liquid metal. Downstream, a temperature measurement is performed to detect a "ripple" in the local temperature associated with the passing "hotspot" in the propellant. By measuring the time between the upstream generation and downstream detection of the thermal feature, the flow speed can be calculated using a "time of flight" analysis. In addition, the system can be calibrated by measuring the accumulated mass exiting the system as a-function of time and correlating this with the time it takes the hotspot to convect through the sensor. The primary advantage of this technique is that it doesn't depend on an absolute measurement of temperature but, instead, relies on the observation of thermal features. This makes the technique insensitive to other externally generated thermal fluctuations. In this paper, we describe experiments performed using the hotspot flow sensor aimed at quantifying the resolution of the sensor technology. Propellant is expelled onto an electronic scale to provide an independent measure of the propellant mass flow rate as a function of time. In addition, two separate detection schemes are employed. The first uses a thermocouple to directly measure temperature in the fluid. The second involves the ,use of a fiber optic coupled to a photodiode allowing for detection of an increase in light emission from the fluid as the hotspot passes. the detection location.

Polzin, Kurt A.↗

Temperature effect on the performance of a 1D grating-based surface-plasmon resonance sensors

We have theoretically studied the influence of temperature on the performance of a 1D grating sensor based on surface plasmon resonance. Rigorous coupled wave analysis method has been utilized to study the effect of the temperature on the sensing performance. The performance of the sensor has been evaluated on the basis of detection accuracy (DA), the sensitivity (S) and the quality parameter (χ). The effect of temperature on the DA, χ and S of the sensor with two different metals (gold and silver) has been compared. Our analysis exhibits that increasing of temperature may lead to poor detection accuracy and quality of the sensor, but the sensitivity is very stable with the change of temperature. Further, the results confirm that the room temperature T = 300 K provides a high DA and a high S, and a good quality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic Methods for Tracking Particle Motions and Temperatures within Opaque Vessels

A three year LDRD was undertaken to look at the feasibility of using magnetic sensing to determine flows within sealed vessels at high temperatures and pressures. Uniqueness proofs were developed for tracking of single magnetic particles with multiple sensors. Experiments were shown to be able to track up to 3 dipole particles undergoing rigid-body rotational motion. Temperature was wirelessly monitored using magnetic particles in static and predictable motions. Finally high-speed vibrational motion was tracked using magnetic particles. Ideas for future work include using small particles for measuring vorticity and better calibration methods for tracking multiple particles.

47 OTHER INSTRUMENTATION↗

Thin film heat flux sensor for Space Shuttle Main Engine turbine environment

The Space Shuttle Main Engine (SSME) turbine environment stresses engine components to their design limits and beyond. The extremely high temperatures and rapid temperature cycling can easily cause parts to fail if they are not properly designed. Thin film heat flux sensors can provide heat loading information with almost no disturbance of gas flows or of the blade. These sensors can provide steady state and transient heat flux information. A thin film heat flux sensor is described which makes it easier to measure small temperature differences across very thin insulating layers.

Will, Herbert↗

Preparation of the spacer for narrow electrode gap configuration in ionization-based gas sensor

Carbon nanotubes (CNTs) have started to be developed as the sensing element for ionization-based gas sensors due to the demand for improved sensitivity, selectivity, stability and other sensing properties beyond what can be offered by the conventional ones. Although these limitations have been overcome, the problems still remain with the conventional ionization-based gas sensors in that they are bulky and operating with large breakdown voltage and high temperature. Recent studies have shown that the breakdown voltage can be reduced by using nanostructured electrodes and narrow electrode gap. Nanostructured electrode in the form of aligned CNTs array with evenly distributed nanotips can enhance the linear electric field significantly. The later is attributed to the shorter conductivity path through narrow electrode gap. The paper presents the study on the design consideration in order to realize ionization based gas sensor using aligned carbon nanotubes array in an optimum sensor configuration with narrow electrode gap. Several deposition techniques were studied to deposit the spacer, the key component that can control the electrode gap. Plasma spray deposition, electron beam deposition and dry oxidation method were employed to obtain minimum film thickness around 32 {mu}m. For plasma spray method, sand blasting process is required in order to produce rough surface for strong bonding of the deposited film onto the surface. Film thickness, typically about 39 {mu}m can be obtained. For the electron beam deposition and dry oxidation, the film thickness is in the range of nanometers and thus unsuitable to produce the spacer. The deposited multilayer film consisting of copper, alumina and ferum on which CNTs array will be grown was found to be removed during the etching process. This is attributed to the high etching rate on the thin film which can be prevented by reducing the rate and having a thicker conductive copper film.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗