Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Leveraging latest computer science tools to advance nuclear cardiology

Nuclear cardiology has unique advantages compared to other modalities, since the image analysis is already much more automated compared to what is currently clinically performed for CT, MR, or echocardiography imaging. The diverse image and clinical data available to assess coronary disease function, perfusion, flow, and associated CT data provide new opportunities, but logistically these additional assessments increase the overall complexity of SPECT/PET reporting, necessitating additional expertise and time. The advances in artificial intelligence software can be leveraged to obtain comprehensive risk predictions and diagnoses from all available data. They will allow nuclear cardiology to retain competitive edge compared to other modalities and improve its overall clinical utility. These tools will enhance diagnosis and risk prediction beyond what is possible by subjective visual analysis and mental integration of data by physicians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructural Characterization and Pore Structure Analysis of Nuclear Graphite

Graphite will be used as a structural and moderator material in next-generation nuclear reactors. While the overall nature of the production of nuclear graphite is well understood, the historic nuclear grades of graphite are no longer available. This paper reports the virgin microstructural characteristics of filler particles and macro-scale porosity in virgin nuclear graphite grades of interest to the Next Generation Nuclear Plant program. Optical microscopy was used to characterize filler particle size and shape as well as the arrangement of shrinkage cracks. Computer aided image analysis was applied to optical images to quantitatively determine the variation of pore structure, area, eccentricity, and orientation within and between grades. The overall porosity ranged between {approx}14% and 21%. A few large pores constitute the majority of the overall porosity. The distribution of pore area in all grades was roughly logarithmic in nature. The average pore was best fit by an ellipse with aspect ratio of {approx}2. An estimated 0.6-0.9% of observed porosity was attributed to shrinkage cracks in the filler particles. Finally, a preferred orientation of the porosity was observed in all grades.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of the displacement field along a surface crack in a flat plate using optical techniques

Structural components may contain cracks, and for these components a crack tip represents a highly singular stress. The evaluation of the associated strain gradient is difficult to achieve with experimental discrete methods. An efficient alternative are the optical techniques which are non-contact, and so delivering continuous information of the displacement fields and associated derivatives for strain evaluation. This paper describes some experimental methods to fully characterize the displacement field near a crack tip existing in flat plates. Three optical field techniques based on image analysis were used in the present work; respectively, Electronic Speckle Pattern Interferometry, Moiré Interferometry, and Digital Image Correlation. These methods allow different resolutions which can be adjusted according to the expected strain gradient. While the first method depends on the laser wavelength and position of the illumination sources, the second depends on the grating pitch and the last on the surface texture or painted speckle. Algorithms to derivate and filtering the displacement field are developed to compute the strain field and will be used for further works.

36 MATERIALS SCIENCE↗

MO-F-CAMPUS-J-05: Verification for Prompt Gamma Ray Imaging During Proton Boron Fusion Therapy

Purpose: The purpose of this study is to verify the acquisition of the three dimensional single photon emission computed tomography (SPECT) image using prompt gamma ray originated from proton boron fusion therapy (PBFT). Methods: The real-time imaging system during the PBFT was simulated to acquire the tomographic image of the prompt gamma ray from treated tumor by the proton boron reaction, using Monte Carlo simulation (MCNPX). We acquired percentage depth dose (PDD) of the proton beam in the water phantom including the boron uptake region (BUR), the energy spectra of the prompt gamma ray and tomographic image which can show treated tumor regions. The prompt gamma ray image was reconstructed using maximum likelihood estimation maximization (MLEM) reconstruction algorithm with 64 projections. In addition, in order to evaluate the reconstructed image, the image profiles between BURs were extracted from the image. Results: In the PDD results, the Bragg-peak was amplified definitely when the proton’s maximum dose level was located at the BUR. This amplification is based on the generation of alpha particles. In addition, the prompt gamma ray peak of 719 keV was observed from the energy spectrum. Through the previous process, the tomographic image of prompt gamma ray from the BUR was reconstructed. The line profile was extracted from image including BURs, and it shows high signal-to-noise ratio. Conclusion: We confirmed that the real-time prompt gamma ray image during the PBFT was successfully deducted, and results of quantitative image analysis show good agreement with the original pattern of the BUR. This study first verified the imaging capability of the PBFT-SPECT system. In conclusion, the PBFT-SPECT system can realize the treated tumor monitoring during the PBFT.

60 APPLIED LIFE SCIENCES↗

Lessons Learned From Developing A Streaming Data Framework for Scientific Analysis

We describe the development and usage of a streaming data analysis software framework. The framework is used for three different applications: Earth science hyper-spectral imaging analysis, Electromyograph pattern detection, and Electroencephalogram state determination. In each application the framework was used to answer a series of science questions which evolved with each subsequent answer. This evolution is summarized in the form of lessons learned.

Wheeler. Kevin R.↗

Celestial Navigation in Cislunar Space with autoNGC

Celestial navigation (CelNav) is a source of navigation observables where images of known solar system bodies are used to locate a spacecraft, beneficial within the solar system for both cislunar and deep space missions. CelNav provides a variety of design benefits to support and enable current and new autonomous space operations- using only a camera and a processor to produce in-situ measurements for navigation. This technology reduces subscription to ground-based tracking during all phases of a mission, freeing up resources for other operational needs. This also supports secure navigation since it eliminates the need for ground contact. CelNav enables missions where the light time delay between Earth and the spacecraft is too long (or the Earth to spacecraft line of sight is obscured) to support critical operations. It also enables smaller mission classes, where Deep Space Network (DSN)time is cost prohibitive, to reduce its cost by focusing primarily on data downlink. Finally, it enables the NASA Artemis program and other cislunar human space flight by providing redundant navigation to traditional radiometric tracking. In this presentation, we discuss the implementation of a CelNav app in autonomous Navigation, Guidance, and Control (autoNGC), a comprehensive flight software suite for onboard autonomy that is built on the core Flight System (cFS). The presentation also summarizes the results of flight software-in-the-loop (SIL) and processor-in-the-loop (PIL) demonstrations. Both are high-fidelity simulations with the use of a camera emulator hosted on a GPU server that simulates images that would be captured by the camera. The CelNav app leverages the use of cGIANT (cFS Goddard Image Analysis and Navigation Tool).Previously developed for the autoNGC software suite, cGIANT is an onboard autonomous image processing and optical navigation (OpNav) tool that performs limb-based OpNav and Terrain Relative Navigation. The added CelNav capability of cGIANT generates bearing measurements to multiple known celestial bodies (planets, moons, asteroids, comets, etc.) in monocular (2D) images. These observables are then fed to the Goddard Enhanced Onboard Navigation System (GEONS)navigation filter app, enabling us to navigate the spacecraft autonomously. In early 2025, the autoNGC CelNav capability is planned to be flight tested as part of the onboard autonomy experiment on the Cislunar Autonomous Positioning System Technology Operations and Navigation Experiment(CAPSTONE) spacecraft that is currently in a Lunar Near Rectilinear Halo Orbit(NRHO).

celestial navigation↗

Evaluating the reforested area for the municipality of Buri by automatic analysis of LANDSAT imagery

The author has identified the following significant results. The class of reforestation (Pinus, Eucalyptus, Araucaria) was defined using iterative image analysis (1-100) and LANDSAT MSS data. Estimates of class area by 1-100 were compared with data supplied by the forestry institute in Sao Paulo. LANDSAT channels 4 and 5 served to differentiate the Pinus, Eucalyptus, and Araucaria from the other trees. Channels 6 and 7 gave best results for differentiating between the classes. A good representative spectral response was obtained for Auraucaria on these two channels. The small relative differences obtained were +4.24% for Araucaria, -7.51% for Pinus, and -32.07% for Eucalyptus.

Dejesusparada, N.↗

Understanding Complex Magnetic Spin Textures with Simulation-Assisted Lorentz Transmission Electron Microscopy

There is an increased interest in topologically nontrivial magnetic spin textures such as skyrmions and chiral domain-wall solitons, both from a point of fundamental physics understanding as well as potential technological interest in low-power memory applications. In order to control their behavior, it is necessary to understand their complex spin texture at the nanoscale. Lorentz transmission electron microscopy (LTEM) is a suitable technique for studying these systems due to its high spatial resolution and capability to simultaneously characterize magnetic texture and microstructure. In this work, we present the application of PyLorentz, an open-source software suite that we have developed, for quantitative image analysis of Neel-type skyrmions in thin-film heterostructures. PyLorentz enhances LTEM capabilities by enabling reconstruction of magnetic induction maps from experimental images, as well as simulating LTEM images using micromagnetic simulation data. We demonstrate this for simulated Neel skyrmions as well as experimental data from [Pt/Co/W] multilayer heterostructures. Finally, we also show how simulation-assisted LTEM analysis is crucial for understanding these complex magnetic spin textures, in which the reconstructed magnetic induction map (seen in the LTEM images) differs significantly from the magnetization configuration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automated optical microscopy of coated particle fuel

Fundamental technological advances have occurred during the 20 year hiatus in US research on coated particle nuclear fuel. As part of the recent US Department of Energy s Advanced Gas Reactor Fuel Development and Qualification program, Oak Ridge National Laboratory has utilized advancements in computer automation, digital imaging, and image analysis to modernize US optical microscopy techniques for coated particle nuclear fuel. Automated optical microscopy has enabled detailed and objective analysis of individual particles (hundreds of measurements per particle) and of large sample sizes that far exceed the capabilities of conventional manual microscopy methods (analysis of 1500-5000 particles is common). Demonstrative examples of the capabilities of this automated optical microscopy are given for: (a) shadow imaging of kernels, coated fuel particles, and graphite matrix overcoated particles and (b) cross-sectional analysis of coated fuel particles to determine layer thicknesses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sol-gel synthesis of Mn1.5Co1.5O4 spinel nano powders for coating applications

Highlights: • Nano powder of Mn/Co spinel, applicable to solid oxide fuel cell, is synthesized. • The sol-gel synthesis of nanocrystalline Mn{sub 1.5}Co{sub 1.5}O{sub 4} spinel is investigated. • Sol-gel annealing temperature, time, and metal-to-citrate ratio are evaluated. • The optimum conditions for producing dual phase of Mn{sub 1.5}Co{sub 1.5}O{sub 4} are achieved. - Abstract: Mn{sub 1.5}Co{sub 1.5}O{sub 4} oxide spinels are widely used as protective coatings for stainless steel interconnects within planar solid oxide fuel cell stacks. Containing both cubic and tetragonal crystalline phases, these Mn/Co oxide spinels exhibit favorable thermal stability and electronic conductivity for the SOFC interconnect application. Slurry-based coating applications of Mn/Co oxides require precursor powders, which can benefit from being nano-structured. In this study, the sol-gel synthesis of nanocrystalline Mn{sub 1.5}Co{sub 1.5}O{sub 4} spinel is investigated. The decomposition of sol-gel precursors, as well as the crystalline phase structures and microstructures of the product Mn{sub 1.5}Co{sub 1.5}O{sub 4} are characterized by differential thermal and thermogravimetric (DTA/TG) analysis, X-ray diffraction (XRD), and transmission electron microscopy (TEM). The effects of various sol-gel annealing temperatures (T), treatment times (t), and citrate-to-metal ratios (Rc) are evaluated. Results suggest that nanocrystalline Mn{sub 1.5}Co{sub 1.5}O{sub 4} spinel can be synthesized around 1050 °C, and that T = 1050 °C, t = 6 h and Rc = 2 are optimum conditions for producing the smallest grain size. Image analysis of TEM results shows that the size of Mn{sub 1.5}Co{sub 1.5}O{sub 4} crystallites increases with increasing temperature, with average particle sizes ranging from ∼70 nm to ∼1 μm. Selected area diffraction pattern (SADP) of Mn{sub 1.5}Co{sub 1.5}O{sub 4} spinel synthesized at 800 °C confirms the dual (cubic/tetragonal) structure of Mn{sub 1.5}Co{sub 1.5}O{sub 4}.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Analysis of Radar Images of Angkor, Cambodia

This paper will focus on our analysis of the imaging radar data in support of archaeological studies and subsequent ground verification of some of the features visible in the radar data.

AirSAR↗

Identification and Quantification of Carbon Phases in Conversion Fuel for the Transient Reactor Test Facility

As part of an overall effort to convert US research reactors to low-enriched uranium (LEU) fuel, a LEU conversion fuel is being designed for the Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory. TREAT fuel compacts are comprised of UO{sub 2} fuel particles in a graphitic matrix material. In order to refine heat transfer modeling, as well as determine other physical and nuclear characteristics of the fuel, the amount and type of graphite and non-graphite phases within the fuel matrix must be known. In this study, we performed a series of complementary analyses, designed to allow detailed characterization of the graphite and phenolic resin based fuel matrix. Methods included Scanning Electron Microscopy, Raman spectroscopy, and X-ray Diffraction. Our results indicate that no single characterization technique will yield all of the desired information; however, through the use of statistical and empirical data analysis, such as curve fitting, partial least squares regression, volume extrapolation and spectra peak ratios, a degree of certainty for the quantity of each phase can potentially be obtained. Although no one type of analysis has provided a complete determination of the quantities and identities of all carbon phases present in the fuel matrix, additional information has been gathered and is being used to refine future analysis methods. From the three types of quantification performed, results have been within 1% (92.8%, 93.02% and 93.6% for BSE image analysis, XRD and Raman spectroscopy, respectively). More work remains to identify any trace crystalline carbonaceous phases that may be present, quantify any traces that are identified, and develop and use further complementary bulk phase quantification techniques. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast GPU 3D diffeomorphic image registration

3D image registration is one of the most fundamental and computationally expensive operations in medical image analysis. Here, we present a mixed-precision, Gauss–Newton–Krylov solver for diffeomorphic registration of two images. Our work extends the publicly available CLAIRE library to GPU architectures. Despite the importance of image registration, only a few implementations of large deformation diffeomorphic registration packages support GPUs. Our contributions are new algorithms to significantly reduce the run time of the two main computational kernels in CLAIRE: calculation of derivatives and scattered-data interpolation. Additionally, we deploy (i) highly-optimized, mixed-precision GPU-kernels for the evaluation of scattered-data interpolation, (ii) replace Fast-Fourier-Transform (FFT)-based first-order derivatives with optimized 8th-order finite differences, and (iii) compare with state-of-the-art CPU and GPU implementations. As a highlight, we demonstrate that we can register clinical images in less than 6 s on a single NVIDIA Tesla V100. This amounts to over 20 speed-up over the current version of CLAIRE and over 30 speed-up over existing GPU implementations.

97 MATHEMATICS AND COMPUTING↗

Using x-ray microtomography and pore-scale modeling to quantify sediment mixing and fluid flow in a developing streambed

X-ray micro-tomography (XMT), image processing, and lattice Boltzmann (LB) methods were combined to observe sediment mixing, subsurface structure, and patterns of hydrogeological properties associated with bed sediment transport. Transport and mixing of sand and spherical glass beads were observed in a laboratory flume, beginning from a well-defined layered initial condition. Cores were obtained from the streambed at four different times, and each core was scanned by XMT in order to assess the evolution of spatial patterns within the bed. Image analysis clearly revealed the propagation of a sediment mixing front that began at the bed surface. The image data were used as boundary conditions in 3D LB simulation of pore fluid flow, showing that sediment sorting produced strong vertical gradients in permeability near the streambed surface. This new methodological approach offers potential for greatly improved characterization of mixing and transport of fine sediments in a wide variety of aquatic systems.

58 GEOSCIENCES↗

Display management subsystem, version 1: A user's eye view

The structure and application functions of the Display Management Subsystem (DMS) are described. The DMS, a subsystem of the Transportable Applications Executive (TAE), was designed to provide a device-independent interface for an image processing and display environment. The system is callable by C and FORTRAN applications, portable to accommodate different image analysis terminals, and easily expandable to meet local needs. Generic applications are also available for performing many image processing tasks.

Parker, Dolores↗

General-purpose interface bus for multiuser, multitasking computer system

The architecture of a multiuser, multitasking, virtual-memory computer system intended for the use by a medium-size research group is described. There are three central processing units (CPU) in the configuration, each with 16 MB memory, and two 474 MB hard disks attached. CPU 1 is designed for data analysis and contains an array processor for fast-Fourier transformations. In addition, CPU 1 shares display images viewed with the image processor. CPU 2 is designed for image analysis and display. CPU 3 is designed for data acquisition and contains 8 GPIB channels and an analog-to-digital conversion input/output interface with 16 channels. Up to 9 users can access the third CPU simultaneously for data acquisition. Focus is placed on the optimization of hardware interfaces and software, facilitating instrument control, data acquisition, and processing.

Generazio, Edward R.↗

The interpretation of simultaneous soft X-ray spectroscopic and imaging observations of an active region

Simultaneous soft X-ray spectroscopic and broad-band imaging observations of an active region have been analyzed together to determine the parameters which describe the coronal plasma. From the spectroscopic data, models of temperature-emission measure-elemental abundance have been constructed which provide acceptable statistical fits. By folding these possible models through the imaging analysis, models which are not self-consistent can be rejected. In this way, only the oxygen, neon, and iron abundances of Pottasch (1967), combined with either an isothermal or exponential temperature-emission-measure model, are consistent with both sets of data. Contour maps of electron temperature and density for the active region have been constructed from the imaging data. The implications of the analysis for the determination of coronal abundances and for future satellite experiments are discussed.

Davis, J. M.↗

A porous open-framework titanium oxophenylphosphate

Highly porous titanium oxophenylphosphate (TPP-1) has been synthesized hydrothermally at 448 K using phenylphosphonic acid (PPA) as the organophosphorus source without the aid of any template or structure-directing agent (SDA). Powder XRD, TEM, SEM-EDS, N{sub 2} sorption, ICP-AES chemical analysis, {sup 13}C and {sup 31}P MAS NMR, UV-Vis, XPS spectroscopic tools, TG-DTA and NH{sub 3}-TPD were used to characterize this material. XRD, N{sub 2} sorption and TEM image analysis suggested the disordered layered framework structure and the presence of large-size micropores along with mesopores in this material. Spectroscopic data suggested the presence of phenyl group, O, Ti and P in this open-framework material, where Ti centers can adopt both tetrahedral and octahedral geometry. TPP-1 showed fairly good H{sub 2} adsorption capacity under normal pressure to high pressure at 77 K. Physisorption data on hydrogen has suggested the potential application of this porous material in H{sub 2} storage. - Graphical abstract: Display Omitted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗