Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging System Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

TH-C-18A-10: The Influence of Tube Current On X-Ray Focal Spot Size for 70 KV CT Imaging

Purpose: Focal spot blooming is an increase in the focal spot size at increased tube current and/or decreased tube potential. In this work, we evaluated the influence of tube current on the focal spot size at low kV for two CT systems, one of which used a tube designed to reduce blooming effects. Methods: A slit camera (10 micron slit) was used to measure focal spot size on two CT scanners from the same manufacturer (Siemens Somatom Force and Definition Flash) at 70 kV and low, medium and maximum tube currents, according to the capabilities of each system (Force: 100, 800 and 1300 mA; Flash: 100, 200 and 500 mA). Exposures were made with a stationary tube in service mode using a raised stand without table movement or flying focal spot technique. Focal spot size, nominally 0.8 and 1.2 mm, respectively, was measured parallel and perpendicular to the cathode-anode axis by calculating the full-width-at-half-maximum of the slit profile recording using computed radiographic plates. Results: Focal spot sizes perpendicular to the anode-cathode axis increased at the maximum mA by 5.7% on the Force and 39.1% on the Flash relative to that at the minimal mA, even though the mA was increased 13-fold on the Force and only 5- fold on the Flash. Focal spot size increased parallel to the anode-cathode axis by 70.4% on Force and 40.9% on Flash. Conclusion: For CT protocols using low kV, high mA is typically required. These protocols are relevant in children and smaller adults, and for dual-energy scanning. Technical measures to limit focal spot blooming are important in these settings to avoid reduced spatial resolution. The x-ray tube on a recently-introduced scanner appears to greatly reduce blooming effects, even at very high mA values. CHM has research support from Siemens Healthcare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared-Fused Vision-Based Thermoregulation Performance Estimation for Personal Thermal Comfort-Driven HVAC System Controls

Thermal comfort is one of the primary factors influencing occupant health, well-being, and productivity in buildings. Existing thermal comfort systems require occupants to frequently communicate their comfort vote via a survey which is impractical as a long-term solution. Here, we present a novel thermal infrared-fused computer vision sensing method to capture thermoregulation performance in a non-intrusive and non-invasive manner. In this method, we align thermal and visible images, detect facial segments (i.e., nose, eyes, face boundary), and accordingly read the temperatures from the appropriate coordinates in the thermal image. We focus on the human face since it is often clearly visible to cameras and is not merged into a hot background (unlike hands). We use a regularized Gaussian Mixture model to track the thermoregulation changes over time and apply a heuristic algorithm to extract hot and cold indices. We present a personalized and a generalized comfort modeling method, selected based on the availability of the occupant historical indices measurements in a neutral environment, and use the time-series of the hot and cold indices to define corrections to HVAC system operations in the form of setpoint constraints. To evaluate the efficacy of our proposed approach in responding to thermal stimuli, we designed a series of controlled experiments to simulate exposure to cold and hot environments. While applying personalized modeling showed an acceptable average accuracy of 91.3%, the generalized model’s average accuracy was only 65.2%. This shows the importance of having access to physiological records in modeling and assessing comfort. We also found that individual differences should be considered in selecting the cooling and heating rates when some knowledge of the occupant’s overall thermal preference is available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

First Observations of Gigantic Jets from Geostationary Orbit

In this work, we present the first observations of gigantic jets (GJs) by the Geostationary Lightning Mapper (GLM) on board the Geostationary Operational Environmental Satellite-R series. Fourteen GJs produced by Tropical Storm Harvey on 19 August 2017 were observed by both GLM and a ground-based low-light-level camera system. The majority of the GJs produced distinguishable signatures in the GLM data, which include long continuous emissions, large peak flash optical energies, and small lateral propagation distances in comparison with other flashes observed by GLM. For two GJs with the best ground-based images, each have a single pixel that contains the largest optical energy throughout the duration of the GJ and also coincides with the azimuth of the GJ from the video images. The optical energy of the pixel increases as the GJ propagates upward, reaches its peak when the GJ connects to the ionosphere, and then fades away.

54 ENVIRONMENTAL SCIENCES↗

Coherent correlation imaging for resolving fluctuating states of matter

Fluctuations and stochastic transitions are ubiquitous in nanometre-scale systems, especially in the presence of disorder. However, their direct observation has so far been impeded by a seemingly fundamental, signal-limited compromise between spatial and temporal resolution. Here we develop coherent correlation imaging (CCI) to overcome this dilemma. Our method begins by classifying recorded camera frames in Fourier space. Contrast and spatial resolution emerge by averaging selectively over same-state frames. Temporal resolution down to the acquisition time of a single frame arises independently from an exceptionally low misclassification rate, which we achieve by combining a correlation-based similarity metric with a modified, iterative hierarchical clustering algorithm. We apply CCI to study previously inaccessible magnetic fluctuations in a highly degenerate magnetic stripe domain state with nanometre-scale resolution. We uncover an intricate network of transitions between more than 30 discrete states. Our spatiotemporal data enable us to reconstruct the pinning energy landscape and to thereby explain the dynamics observed on a microscopic level. CCI massively expands the potential of emerging high-coherence X-ray sources and paves the way for addressing large fundamental questions such as the contribution of pinning and topology in phase transitions and the role of spin and charge order fluctuations in high-temperature superconductivity.

36 MATERIALS SCIENCE↗

HUNTING FOR PLANETS IN THE HL TAU DISK

Recent ALMA images of HL Tau show gaps in the dusty disk that may be caused by planetary bodies. Given the young age of this system, if confirmed, this finding would imply very short timescales for planet formation, probably in a gravitationally unstable disk. To test this scenario, we searched for young planets by means of direct imaging in the L′ band using the Large Binocular Telescope Interferometer mid-infrared camera. At the location of two prominent dips in the dust distribution at ∼70 AU (∼0.″5) from the central star, we reach a contrast level of ∼7.5 mag. We did not detect any point sources at the location of the rings. Using evolutionary models we derive upper limits of ∼10–15 M{sub Jup} at ≤0.5–1 Ma for the possible planets. With these sensitivity limits we should have been able to detect companions sufficiently massive to open full gaps in the disk. The structures detected at millimeter wavelengths could be gaps in the distributions of large grains on the disk midplane caused by planets not massive enough to fully open the gaps. Future ALMA observations of the molecular gas density profile and kinematics as well as higher contrast infrared observations may be able to provide a definitive answer.

79 ASTRONOMY AND ASTROPHYSICS↗

THE REST-FRAME ULTRAVIOLET LIGHT PROFILE SHAPES OF Ly{alpha}-EMITTING GALAXIES AT z = 3.1

We present a morphological analysis of the rest-frame ultraviolet emission of 78 resolved, high signal-to-noise z {approx} 3.1 Ly{alpha} emitters (LAEs) in the Extended Chandra Deep Field-South. Using Hubble Space Telescope/Advanced Camera for Surveys V-band images taken as part of the Galaxy Evolution from Morphology and SEDs, Great Observatories Origins Deep Survey, and Hubble Ultra Deep Field surveys, we investigate both single-component and multi-component LAEs, and derive concentration indices, Sersic indices, ellipticities, and half-light radii for all resolved components and systems with a signal-to-noise >30. We show that, although the LAE population is heterogeneous in nature, most LAEs are highly concentrated, with a distribution of C values similar to that measured for field stars; this suggests that the diagnostic is a poor discriminator near the resolution limit. The LAEs also display a wide range of Sersic indices (0 < n < 12), similar to that seen for galaxies in the local neighborhood. However, the majority of LAEs have n < 2, and a visual inspection of the images suggests that the small-n objects have extended or multimodal luminosity profiles, while the LAEs with n > 2 have compact components surrounded by diffuse emission. Moreover, unlike nearby spiral galaxies, whose distribution of ellipticities is flat, the LAE ellipticity distribution peaks near 1 - b/a {approx} 0.55. Thus, the population has more in common with z {approx} 3 Lyman-break galaxies than local star-forming objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗

Astrometric performance of the Gemini multiconjugate adaptive optics system in crowded fields

The Gemini multiconjugate adaptive optics system (GeMS) is a facility instrument for the Gemini South telescope. It delivers uniform, near-diffraction-limited image quality at near-infrared wavelengths over a 2 arcmin field of view. Together with the Gemini South Adaptive Optics Imager (GSAOI), a near-infrared wide-field camera, GeMS/GSAOI's combination of high spatial resolution and a large field of view will make it a premier facility for precision astrometry. Potential astrometric science cases cover a broad range of topics including exoplanets, star formation, stellar evolution, star clusters, nearby galaxies, black holes and neutron stars, and the Galactic Centre. In this paper, we assess the astrometric performance and limitations of GeMS/GSAOI. In particular, we analyse deep, mono-epoch images, multi-epoch data and distortion calibration. In this work, we find that for single-epoch, undithered data, an astrometric error below 0.2 mas can be achieved for exposure times exceeding 1 min, provided enough stars are available to remove high-order distortions. We show however that such performance is not reproducible for multi-epoch observations, and an additional systematic error of ~0.4 mas is evidenced. This systematic multi-epoch error is the dominant error term in the GeMS/GSAOI astrometric error budget, and it is thought to be due to time-variable distortion induced by gravity flexure.

79 ASTRONOMY AND ASTROPHYSICS↗

Ecological Monitoring and Compliance Program 2014 Report

The Ecological Monitoring and Compliance Program (EMAC), funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO, formerly Nevada Site Office), monitors the ecosystem of the Nevada National Security Site (NNSS) and ensures compliance with laws and regulations pertaining to NNSS biota. This report summarizes the program’s activities conducted by National Security Technologies, LLC (NSTec), during calendar year 2014. Program activities included (a) biological surveys at proposed activity sites, (b) desert tortoise compliance, (c) ecosystem monitoring, (d) sensitive plant species monitoring, (e) sensitive and protected/regulated animal monitoring, and (f) habitat restoration monitoring. During 2014, all applicable laws, regulations, and permit requirements were met, enabling EMAC to achieve its intended goals and objectives. Sensitive and protected/regulated species of the NNSS include 42 plants, 1 mollusk, 2 reptiles, 236 birds, and 27 mammals. These species are protected, regulated, or considered sensitive according to state or federal regulations and natural resource agencies and organizations. The desert tortoise (Gopherus agassizii) and the western yellow-billed cuckoo (Coccyzus americanus) are the only species on the NNSS protected under the Endangered Species Act, both listed as threatened. However, only one record of the cuckoo has ever been documented on the NNSS, and there is no good habitat for this species on the NNSS. It is considered a rare migrant. Biological surveys for the presence of sensitive and protected/regulated species and important biological resources on which they depend were conducted for 18 projects. A total of 199.18 hectares (ha) was surveyed for these projects. Sensitive and protected/regulated species and important biological resources found during these surveys included a predator burrow, one sidewinder rattlesnake (Crotalus cerastes), two mating speckled rattlesnakes (Crotalus mitchellii), and several species of cacti. NSTec provided to project managers a written summary report of all survey findings and mitigation recommendations, where applicable. Of the 18 projects on the NNSS, 15 occurred within the range of the threatened desert tortoise. Approximately 2.19 ha of desert tortoise habitat were disturbed. No desert tortoises were accidentally injured or killed by project activities, and no tortoises were killed by vehicles. On 13 occasions, tortoises were moved off the road and out of harm’s way. Six tortoises were found and transmitters attached as part of an approved study to assess impacts of vehicles on tortoises on the NNSS. NSTec biologists continued to monitor 37 juvenile desert tortoises as part of a collaborative effort to study survival and temperament of translocated animals. From 1978 until 2013, there has been an average of 11.2 wildland fires per year on the NNSS with an average of about 83.7 ha burned per fire. There were no wildland fires documented on the NNSS during 2014. Results from the wildland fuel surveys showed a very low risk of wildland fire due to reduced fuel loads caused by limited natural precipitation. Limited reptile trapping and reptile roadkill surveys were conducted to better define species distribution on the NNSS. Sixteen reptiles were trapped representing five species. Combined with data from 2013, 183 road kills were detected, representing 11 snake and 8 lizard species. Selected natural water sources were monitored to assess trends in physical and biological parameters, and one new water source was found. Wildlife use at five water troughs and four radiologically contaminated sumps was documented using motion-activated cameras. As part of the statewide effort to disseminate information throughout the botanical community, NSTec prepared a shape file with site-specific data for all 17 sensitive plants on the NNSS and provided it to the Nevada Natural Heritage Program for inclusion in their statewide database. No field surveys were conducted this year for sensitive plants on the NNSS due to poor growing conditions. Surveys of sensitive and protected/regulated animals during 2014 focused on winter raptors, bats, wild horses (Equus caballus), mule deer (Odocoileus hemionus), desert bighorn sheep (Ovis Canadensis nelsoni), and mountain lions (Puma concolor). Two permanent, long-term winter raptor survey routes were established and sampled in January and February. A total of 27 raptors representing 4 species were observed. The wild horse population increased from 30 to 41, with several yearlings recruiting into the population, possibly due to the death of a mountain lion known to prey on horse foals. Mule deer abundance and density measured with standardized deer surveys was similar to 2013 and appears to be stable. Desert bighorn sheep, including rams, ewes, and lambs, were detected using motion-activated cameras at four water sources. There are plans to conduct helicopter surveys to census the population during September 2015 and then capture and radio-collar up to 20 sheep during November 2015. Over 150 sheep scat samples have been collected for genetic analysis to try to determine how sheep on the NNSS are related to surrounding sheep populations. Information is presented about bird mortalities, Migratory Bird Treaty Act compliance, and a summary of nuisance animals and their control on the NNSS. A total of 93 mountain lion images (i.e., photographs or video clips) were taken during 220,379 camera hours at 16 of 32 sites sampled and another 11,946 images of at least 29 species other than mountain lions were taken as well. A mountain lion telemetry study continued in 2014. NNSS7 was tracked from January 1 to November 15 using a global positioning system satellite transmitter. He consumed 21 mule deer, 17 desert bighorn sheep, 1 juvenile bobcat, and 3 coyotes. Mule deer were primarily taken in the summer and fall. No new mountain lions were captured. A minimum of four adult lions (two males, two females), a subadult male, and three kittens were known to inhabit the NNSS during 2014. Two previously revegetated sites on the NNSS and one on the Tonopah Test Range (TTR) were monitored in 2014. The cover cap on the U-3ax/bl disposal unit, revegetated in 2000, and the 92-Acre Site at the Area 5 Radioactive Waste Management Complex, revegetated in 2011, were the restoration sites monitored on the NNSS. The Corrective Action Unit 407 Rollercoaster RADSAFE site, revegetated in 2000, was the restoration site monitored on the TTR. Plant cover and density were recorded at all sites except U-3ax/bl (qualitative monitoring), and reclamation success standards were evaluated, where applicable.

54 ENVIRONMENTAL SCIENCES↗

Compton tomography system

A Compton tomography system comprises an x-ray source configured to produce a planar x-ray beam. The beam irradiates a slice of an object to be imaged, producing Compton-scattered x-rays. The Compton-scattered x-rays are imaged by an x-ray camera. Translation of the object with respect to the source and camera or vice versa allows three-dimensional object imaging.

47 OTHER INSTRUMENTATION↗

Non-contact rapid reader system for reflective particle tags

A reflective particle tag reader system includes a read head assembly having a camera, illuminators, and a rigid frame portion for supporting the camera and the illuminators. The illuminators illuminate a focal point located opposite the camera where a reflective particle tag is placed. A computer in data communication with the camera receives and store images of the reflective particle tag that are acquired by the camera. The computer is programmed to process video images and to quantify a positional alignment parameter and an angular alignment parameter of the reader with respect to the reflective particle tag. A rapid burst of image frames is obtained in response to the positional alignment and the angular alignment parameters being within a predetermined tolerance and identity of the reflective tag is established between a first image set and a second image set.

42 ENGINEERING↗

SU-E-T-641: Proton Range Measurements Using a Geometrically Calibrated Liquid Scintillator Detector

Purpose: The purpose of this work is to develop a geometric calibration method to accurately calculate physical distances within a liquid scintillator detector and to assess the accuracy, consistency, and robustness of proton beam range measurements when using a liquid scintillator detector system with the proposed geometric calibration process. Methods: We developed a geometric calibration procedure to accurately convert pixel locations in the camera frame into physical locations in the scintillator frame. To ensure accuracy, the geometric calibration was performed before each experiment. The liquid scintillator was irradiated with spot scanning proton beams of 94 energies in two deliveries. A CCD camera was used to capture the two-dimensional scintillation light profile of each of the proton energies. An algorithm was developed to automatically calculate the proton range from the acquired images. The measured range was compared to the nominal range to assess the accuracy of the detector. To evaluate the robustness of the detector between each setup, the experiments were repeated on three different days. To evaluate the consistency of the measurements between deliveries, three sets of measurements were acquired for each experiment. Results: Using this geometric calibration procedure, the proton beam ranges measured using the liquid scintillator system were all within 0.3mm of the nominal range. The average difference between the measured and nominal ranges was −0.20mm. The delivery-to-delivery standard deviation of the proton range measurement was 0.04mm, and the setup-to-setup standard deviation of the measurement was 0.10mm. Conclusion: The liquid scintillator system can measure the range of all 94 beams in just two deliveries. With the proposed geometric calibration, it can measure proton range with sub-millimeter accuracy, and the measurements were shown to be consistent between deliveries and setups. Therefore, we conclude that the liquid scintillator system provides a reliable and convenient tool for proton range measurement. This project was supported in part by award number CA182450 from the National Cancer Institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DISCOVERY OF A LOW-MASS COMPANION AROUND HR 3549

We report the discovery of a low-mass companion to HR 3549, an A0V star surrounded by a debris disk with a warm excess detected by WISE at 22 μm (10σ significance). We imaged HR 3549 B in the L band with NAOS-CONICA, the adaptive optics infrared camera of the Very Large Telescope, in January 2013 and confirmed its common proper motion in 2015 January. The companion is at a projected separation of ≃80 AU and position angle of ≃157°, so it is orbiting well beyond the warm disk inner edge of r > 10 AU. Our age estimate for this system corresponds to a companion mass in the range 15–80 M{sub J}, spanning the brown dwarf regime, and so HR 3549 B is another recent addition to the growing list of brown dwarf desert objects with extreme mass ratios. The simultaneous presence of a warm disk and a brown dwarf around HR 3549 provides interesting empirical constraints on models of the formation of substellar companions.

79 ASTRONOMY AND ASTROPHYSICS↗

A philosophy for CNS radiotracer design

Decades after its discovery, positron emission tomography (PET) remains the premier tool for imaging neurochemistry in living humans. Technological improvements in radiolabeling methods, camera design, and image analysis have kept PET in the forefront. In addition, the use of PET imaging has expanded because researchers have developed new radiotracers that visualize receptors, transporters, enzymes, and other molecular targets within the human brain. However, of the thousands of proteins in the central nervous system (CNS), researchers have successfully imaged fewer than 40 human proteins. To address the critical need for new radiotracers, this Account expounds on the decisions, strategies, and pitfalls of CNS radiotracer development based on our current experience in this area. We discuss the five key components of radiotracer development for human imaging: choosing a biomedical question, selection of a biological target, design of the radiotracer chemical structure, evaluation of candidate radiotracers, and analysis of preclinical imaging. It is particularly important to analyze the market of scientists or companies who might use a new radiotracer and carefully select a relevant biomedical question(s) for that audience. In the selection of a specific biological target, we emphasize how target localization and identity can constrain this process and discuss the optimal target density and affinity ratios needed for binding-based radiotracers. In addition, we discuss various PET test–retest variability requirements for monitoring changes in density, occupancy, or functionality for new radiotracers. In the synthesis of new radiotracer structures, high-throughput, modular syntheses have proved valuable, and these processes provide compounds with sites for late-stage radioisotope installation. As a result, researchers can manage the time constraints associated with the limited half-lives of isotopes. In order to evaluate brain uptake, a number of methods are available to predict bioavailability, blood–brain barrier (BBB) permeability, and the associated issues of nonspecific binding and metabolic stability. To evaluate the synthesized chemical library, researchers need to consider high-throughput affinity assays, the analysis of specific binding, and the importance of fast binding kinetics. Lastly, we describe how we initially assess preclinical radiotracer imaging, using brain uptake, specific binding, and preliminary kinetic analysis to identify promising radiotracers that may be useful for human brain imaging. Although we discuss these five design components separately and linearly in this Account, in practice we develop new PET-based radiotracers using these design components nonlinearly and iteratively to develop new compounds in the most efficient way possible.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Advances in phosphor two-color ratio method thermography for full-field surface temperature measurements

We report thermographic phosphors can be employed for optical sensing of surface, gas phase, and bulk material temperatures through different strategies including the time-decay method, time-integrated method, and frequency-domain method. We focus on the time-integrated method, also known as the ratio method, as it can be more practical in many situations. This work advances the ratio method using two machine vision cameras with CMOS detectors for full-field temperature measurements of a solid surface. A phosphor calibration coupon is fabricated using aerosol deposition and employed for in situ determination of the temperature-versus-intensity ratio relationship. Algorithms from digital image correlation are employed to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. Detector nonlinearity is carefully characterized and corrected. Temperature-dependent, spatial non-uniformity of the full-field intensity ratio—posited to be caused by a blue-shift effect of the bandpass filter for non-collimated light and/or a wavelength-dependent transmission efficiency of the lens—is assessed and treated for cases where a standard flat-field correction fails to correct the non-uniformity. In sum, pixel-wise calibration curves relating the computed intensity ratio to temperature in the range of T = 300–430 K are generated, with an embedded error of less than 3 K. This work offers a full calibration methodology and several improvements on two-color phosphor thermography, opening the door for full-field temperature measurements in dynamic tests with deforming test articles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AN EXTREME STARBURST IN THE CORE OF A RICH GALAXY CLUSTER AT z = 1.7

We have discovered an optically rich galaxy cluster at z = 1.7089 with star formation occurring in close proximity to the central galaxy. The system, SpARCS104922.6+564032.5, was detected within the Spitzer Adaptation of the red-sequence Cluster Survey, and confirmed through Keck-MOSFIRE spectroscopy. The rest-frame optical richness of N{sub gal} (500 kpc) = 30 ± 8 implies a total halo mass, within 500 kpc, of ∼3.8 ± 1.2 × 10{sup 14} M{sub ⊙}, comparable to other clusters at or above this redshift. There is a wealth of ancillary data available, including Canada–France–Hawaii Telescope optical, UKIRT-K, Spitzer-IRAC/MIPS, and Herschel-SPIRE. This work adds submillimeter imaging with the SCUBA2 camera on the James Clerk Maxwell Telescope and near-infrared imaging with the Hubble Space Telescope. The mid/far-infrared (M/FIR) data detect an Ultra-luminous Infrared Galaxy spatially coincident with the central galaxy, with L{sub IR} = 6.2 ± 0.9 × 10{sup 12} L{sub ⊙}. The detection of polycyclic aromatic hydrocarbons at z = 1.7 in a Spitzer-IRS spectrum of the source implies the FIR luminosity is dominated by star formation (an Active Galactic Nucleus contribution of 20%) with a rate of ∼860 ± 130 M{sub ⊙} yr{sup −1}. The optical source corresponding to the IR emission is likely a chain of >10 individual clumps arranged as “beads on a string” over a linear scale of 66 kpc. Its morphology and proximity to the Brightest Cluster Galaxy (BCG) imply a gas-rich interaction at the center of the cluster triggered the star formation. This system indicates that wet mergers may be an important process in forming the stellar mass of BCGs at early times.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative Digital Autoradiography for Environmental Swipe Sample Prioritization: System design, Characterization, and Initial Measurements

Environmental sampling and sample analyses by the International Atomic Energy Agency’s (IAEA) Network of Analytical Laboratories (NWAL) is a critical technical tool used to detect facility misuse under a Comprehensive Safeguards Agreement and to verify the absence of undeclared nuclear material activities under an Additional Protocol. Currently all environmental swipe samples (ESS) are screened using gamma spectrometry and x-ray fluorescence to estimate the amount of U and/or Pu in the ESS, to guide further analysis, and to assist in the shipment of ESS to the NWAL. Quantitative Digital Autoradiography for Environmental Samples (QDARES) is being developed to complement existing techniques through the use of a portable, real-time, high-spatial-resolution camera called the Ionizing-radiation Quantum Imaging Detector (iQID). The iQID constructs a spatial map of radionuclides within a sample or surface in real-time as charged particles (betas) and photons (gamma/x-rays) are detected and localized on an event-by-event basis. Knowledge of the location and nature of radioactive hot spots on the ESS could provide information for subsequent laboratory analysis. As a nondestructive technique, QDARES does not compromise the ESS chain of custody or subsequent laboratory analysis. In this paper we will present the system design and construction, characterization measurements with calibration sources, and initial measurements of ESS.

McDonald, Benjamin S.↗

A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager

Purpose: The increasing need for better image quality and high spatial resolution for successful endovascular image-guided interventions (EIGIs) and the inherent limitations of the state-of-the-art detectors provide motivation to develop a detector system tailored to the specific, demanding requirements of neurointerventional applications.Method: A microangiographic fluoroscope (MAF) was developed to serve as a high-resolution, region-of-interest (ROI) x-ray imaging detector in conjunction with large lower-resolution full field-of-view (FOV) state-of-the-art x-ray detectors. The newly developed MAF is an indirect x-ray imaging detector capable of providing real-time images (30 frames per second) with high-resolution, high sensitivity, no lag and low instrumentation noise. It consists of a CCD camera coupled to a Gen 2 dual-stage microchannel plate light image intensifier (LII) through a fiber-optic taper. A 300 {mu}m thick CsI(Tl) phosphor serving as the front end is coupled to the LII. The LII is the key component of the MAF and the large variable gain provided by it enables the MAF to operate as a quantum-noise-limited detector for both fluoroscopy and angiography. Results: The linear cascade model was used to predict the theoretical performance of the MAF, and the theoretical prediction showed close agreement with experimental findings. Linear system metrics such as MTF and DQE were used to gauge the detector performance up to 10 cycles/mm. The measured zero frequency DQE(0) was 0.55 for an RQA5 spectrum. A total of 21 stages were identified for the whole imaging chain and each stage was characterized individually. Conclusions: The linear cascade model analysis provides insight into the imaging chain and may be useful for further development of the MAF detector. The preclinical testing of the prototype detector in animal procedures is showing encouraging results and points to the potential for significant impact on EIGIs when used in conjunction with a state-of-art flat panel detector (FPD).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗