Search NASA⌕ Search

SEARCH · Search NASA

Results for “Importance Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Handling Heavenly Jewels - 35 Years of Antarctic Meteorite Processing at Johnson Space Center

The ANSMET program began in 1976, and since that time more than 18,000 meteorites have been processed in the Meteorite Processing Lab at Johnson Space Center in Houston, TX[1]. The meteorites are collected and returned to JSC on a freezer truck and remain frozen until they are initially processed. Initial Processing of Meteorites: Initial processing involves drying the meteorites in a nitrogen glove box for 24 to 48 hours, photographing, measuring, weighing and writing a description of the interior and exterior. The meteorite is broken and a representative sample is sent to the Smithsonian Institution for classification. Newsletter & Requests: Once initial processing has been complete and the meteorites have been classified, the information is published in the Antarctic Meteorite Newsletter[2,3]. The newsletter is published twice yearly and is sent electronically to researchers around the world and is also available on line. Researchers are asked to fill out a request form and submit it to the Meteorite Working Group secretary. All sample requests will be reviewed by either the meteorite curator or the Meteorite Working Group de-pending on the type of meteorite and the research being conducted. Processing for Sample Requests: In the meteorite processing lab, meteorite samples are prepared several different ways. Most samples are prepared as chips obtained by use of stainless steel chisels in a chipping bowl or rock splitter. In special situations where a researcher needs a slab the meteorite samples can be bandsawed in a dry nitrogen glove box with a diamond blade, no liquids are ever introduced into the cabinet. The last type of sample preparation is thin/thick sections. The meteorite thin section lab at JSC can prepare standard 30-micron thin sections, thick sections of variable thickness (100 to 200 microns), or demountable sections using superglue. Information for researchers: It is important that re-searchers fill the sample request form completely, in order to make sure the meteorite is processed correctly[4]. Re-searchers should list any special requirements on the form, i.e. packaging of samples (poly vs. stainless), thick sections and thickness needed, superglue needed, interior chips, exterior chips, fusion crust, contamination issues, all concerns should be listed so processing can be done accurately and any concerns the researcher has can be addressed be-fore the meteorites are broken.

Satterwhite, C. E.↗

Comparison of methods for the NMR measurement of motionally averaged dipolar couplings

Motionally averaged dipolar couplings are an important tool for understanding the complex dynamics of catalysts, polymers, and biomolecules. While there is a plethora of solid-state NMR pulse sequences available for their measurement, in can be difficult to gauge the methods’ strengths and weaknesses. In particular, there has not been a comprehensive comparison of their performance in natural abundance samples, where 1H homonuclear dipolar couplings are important and the use of large MAS rotors may be required for sensitivity reasons. In this work, we directly compared some of the more common methods for measuring C–H dipolar couplings in natural abundance samples using L-alanine (L-Ala) and the N-formyl-L-methionyl-L-leucyl-L-phenylalanine (fMLF) tripeptide as model systems. Here, we evaluated their performance in terms of accuracy, resolution, sensitivity, and ease of implementation. We found that, despite the presence of 1H homonuclear dipolar interactions, all methods, with the exception of REDOR, were able to yield the reasonable dipolar coupling strengths for both mobile and static moieties. Of these methods, PDLF provides the most convenient workflow and precision at the expense of low sensitivity. In low-sensitivity cases, MAS-PISEMA and DIPSHIFT appear to be the better options.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical investigation of Lower Tuscaloosa Sandstone and Selma Chalk caprock under geological CO 2 sequestration conditions: mineral precipitation and permeability evolution

Abstract A numerical model was developed using CrunchFlow to simulate reactive transport and porosity and permeability changes of sandstone and carbonate rock samples taken from the Lower Tuscaloosa Formation and the Selma Chalk Formation, Jackson County, MS, USA. The model predicted a permeability decrease from 2190 mD to 2038 mD for the Lower Tuscaloosa Sandstone sample in a static batch reactor after 180 days of exposure to CO 2 ‐saturated brine, which is consistent with measured permeability results. The model predicted a negligible permeability change from 2.00 mD to 2.08 mD for the Selma Chalk carbonate sample after 180 days of exposure to CO 2 ‐saturated brine. Based on model prediction, key mineral dissolution and precipitation reactions in the Lower Tuscaloosa Sandstone sample include dissolution of quartz, chlorite, and feldspar, as well as precipitation of amorphous silica and kaolinite. For the Selma Chalk carbonate sample, key predicted reactions include dissolution of calcite, quartz and chlorite, and precipitation of kaolinite and amorphous silica. Initial porosity, initial feldspar content and the exponent n value (related to pore structure and tortuosity) used in permeability calculations were three important factors affecting permeability evolution of sandstone samples under CO 2 sequestration conditions. The small permeability change predicted for both the Lower Tuscaloosa Sandstone and the Selma Chalk caprock after exposure to CO 2 ‐saturated brine suggests that poro‐permeability changes during CO 2 injection into the Lower Tuscaloosa Formation are not likely to significantly affect reservoir and seal quality. © 2017 Society of Chemical Industry and John Wiley & Sons, Ltd.

Zhang, Liwei↗

The role of impact cratering for Mars sample return

The preserved cratering record of Mars indicates that impacts play an important role in deciphering Martian geologic history, whether as a mechanism to modify the lithosphere and atmosphere or as a tool to sample the planet. The various roles of impact cratering in adding a broader understanding of Mars through returned samples are examined. Five broad roles include impact craters as: (1) a process in response to a different planetary localizer environment; (2) a probe for excavating crustal/mantle materials; (3) a possible localizer of magmatic and hydrothermal processes; (4) a chronicle of changes in the volcanic, sedimentary, atmospheric, and cosmic flux history; and (5) a chronometer for extending the geologic time scale to unsampled regions. The evidence for Earth-like processes and very nonlunar styles of volcanism and tectonism may shift the emphasis of a sampling strategy away from equally fundamental issues including crustal composition, unit ages, and climate history. Impact cratering not only played an important active role in the early Martian geologic history, it also provides an important tool for addressing such issues.

Schultz, P. H.↗

Field Geologic Observation and Sample Collection Strategies for Planetary Surface Exploration: Insights from the 2010 Desert RATS Geologist Crewmembers

Observation is the primary role of all field geologists, and geologic observations put into an evolving conceptual context will be the most important data stream that will be relayed to Earth during a planetary exploration mission. Sample collection is also an important planetary field activity, and its success is closely tied to the quality of contextual observations. To test protocols for doing effective planetary geologic field- work, the Desert RATS(Research and Technology Studies) project deployed two prototype rovers for two weeks of simulated exploratory traverses in the San Francisco volcanic field of northern Arizona. The authors of this paper represent the geologist crew members who participated in the 2010 field test.We document the procedures adopted for Desert RATS 2010 and report on our experiences regarding these protocols. Careful consideration must be made of various issues that impact the interplay between field geologic observations and sample collection, including time management; strategies relatedtoduplicationofsamplesandobservations;logisticalconstraintson the volume and mass of samples and the volume/transfer of data collected; and paradigms for evaluation of mission success. We find that the 2010 field protocols brought to light important aspects of each of these issues, and we recommend best practices and modifications to training and operational protocols to address them. Underlying our recommendations is the recognition that the capacity of the crew to flexibly execute their activities is paramount. Careful design of mission parameters, especially field geologic protocols, is critical for enabling the crews to successfully meet their science objectives.

Hurtado, Jose M., Jr.↗

Nonlinearity in chorus waves during a geomagnetic storm on 1 November 2012

In this study, we investigate the possibility of nonlinearity in chorus waves during a geomagnetic storm on 1 November 2012. The data we use were measured by the Van Allen Probe B. Wave data and plasma sheet electron data are analyzed. Chorus waves were frequently measured in the morning side during the main phase of this storm. Large–amplitude chorus waves were seen of the order of ~0.6 nT and >7 mV/m, which are similar to or larger than the typical ULF waves. The waves quite often consist of rising tones during the burst sampling. Since the rising tone is known as a signature of nonlinearity, a large portion of the waves are regarded as nonlinear at least during the burst sampling periods. These results underline the importance of nonlinearity in the dynamics of chorus waves. We further compare the measurement and the nonlinear theories, based on the inhomogeneity ratio, our own calculation derived from the field equation and the backward wave oscillator model. The wave quantities examined are frequency, amplitude, frequency drift rate, and duration. Furthermore, this type of study is useful to more deeply understand wave-particle interactions and hence may lead to predicting the generation and loss of radiation belt electrons in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal behavior of polyhalite: a high-temperature synchrotron XRD study

As an accessory mineral in marine evaporites, polyhalite, K 2 MgCa 2 (SO 4 ) 4 ·2H 2 O, coexists with halite (NaCl) in salt formations, which have been considered as potential repositories for permanent storage of high-level nuclear wastes. However, because of the heat generated by radioactive decays in the wastes, polyhalite may dehydrate, and the released water will dissolve its neighboring salt, potentially affecting the repository integrity. Thus, studying the thermal behavior of polyhalite is important. In this paper, a polyhalite sample containing a small amount of halite was collected from the Salado formation at the WIPP site in Carlsbad, New Mexico. To determine its thermal behavior, in situ high-temperature synchrotron X-ray diffraction was conducted from room temperature to 1066 K with the sample powders sealed in a silica-glass capillary. At about 506 K, polyhalite started to decompose into water vapor, anhydrite (CaSO 4 ) and two langbeinite-type phases, K 2 Ca x Mg 2-x (SO 4 ) 3 , with different Ca/Mg ratios. XRD peaks of the minor halite disappeared, presumably due to its dissolution by water vapor. With further increasing temperature, the two langbeinite solid solution phases displayed complex variations in crystallinity, composition and their molar ratio and then were combined into the single-phase triple salt, K 2 CaMg(SO 4 ) 3 , at ~919 K. Rietveld analyses of the XRD data allowed determination of structural parameters of polyhalite and its decomposed anhydrite and langbeinite phases as a function of temperature. Finally, from the results, the thermal expansion coefficients of these phases have been derived, and the structural mechanisms of their thermal behavior been discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cross-platform pathway-based analysis identifies markers of response to the PARP inhibitor olaparib

Poly(ADP-ribose) polymerase (PARP) is an enzyme involved in DNA repair. PARP inhibitors can act as chemosensitizers, or operate on the principle of synthetic lethality when used as single agent. Clinical trials have shown drugs in this class to be promising for BRCA mutation carriers. We postulated that inability to demonstrate response in non-BRCA carriers in which BRCA is inactivated by other mechanisms or with deficiency in homologous recombination for DNA repair is due to lack of molecular markers that define a responding subpopulation. We identified candidate markers for this purpose for olaparib (AstraZeneca) by measuring inhibitory effects of nine concentrations of olaparib in 22 breast cancer cell lines and identifying features in transcriptional and genome copy number profiles that were significantly correlated with response. We emphasized in this discovery process genes involved in DNA repair. We found that the cell lines that were sensitive to olaparib had a significant lower copy number of BRCA1 compared to the resistant cell lines (p value 0.012). In addition, we discovered seven genes from DNA repair pathways whose transcriptional levels were associated with response. These included five genes (BRCA1, MRE11A, NBS1, TDG, and XPA) whose transcript levels were associated with resistance and two genes (CHEK2 and MK2) whose transcript levels were associated with sensitivity. We developed an algorithm to predict response using the seven-gene transcription levels and applied it to 1,846 invasive breast cancer samples from 8 U133A/plus 2 (Affymetrix) data sets and found that 8–21 % of patients would be predicted to be responsive to olaparib. A similar response frequency was predicted in 536 samples analyzed on an Agilent platform. Importantly, tumors predicted to respond were enriched in basal subtype tumors. Our studies support clinical evaluation of the utility of our seven-gene signature as a predictor of response to olaparib.

59 BASIC BIOLOGICAL SCIENCES↗

Collaborative Study for Certification of Trace Elements in Uranium Ore Concentrate CRMs UCLO-1, UCHI-1, and UPER-1

Trace impurity patterns are important nuclear forensic signatures in uranium ore concentrates (UOCs) and Certified Reference Materials (CRMs) are used to validate the analysis methods employed by end users. Herein, we discuss the certification campaign for three new UOC CRMs from the National Research Council Canada: UCLO-1 (https://doi.org/10.4224/crm.2020.uclo-1), UCHI-1 (https://doi.org/10.4224/crm.2020.uchi-1), and UPER-1 (https://doi.org/10.4224/crm.2020.uper-1). This study involved 15 laboratories from 10 countries, using sector-field and (triple) quadrupole inductively-coupled plasma mass spectrometry to analyze 64 trace element impurities. We discuss the importance of the acids used for sample digestion, difficulties analyzing in a high uranium matrix, and data combination and uncertainty evaluation for this large dataset.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

CryoEM and Molecular Dynamics of the Circadian KaiB-KaiC Complex Indicates That KaiB Monomers Interact with KaiC and Block ATP Binding Clefts

The circadian control of cellular processes in cyanobacteria is regulated by a posttranslational oscillator formed by three Kai proteins. During the oscillator cycle, KaiA serves to promote autophosphorylation of KaiC while KaiB counteracts this effect. Here, we present a crystallographic structure of the wild-type Synechococcus elongatus KaiB and a cryo-electron microscopy (cryoEM) structure of a KaiBC complex. The crystal structure shows the expected dimer core structure and significant conformational variations of the KaiB C-terminal region, which is functionally important in maintaining rhythmicity. The KaiBC sample was formed with a C-terminally truncated form of KaiC, KaiC-Δ489, which is persistently phosphorylated. The KaiB–KaiC-Δ489 structure reveals that the KaiC hexamer can bind six monomers of KaiB, which form a continuous ring of density in the KaiBC complex. We performed cryoEM-guided molecular dynamics flexible fitting simulations with crystal structures of KaiB and KaiC to probe the KaiBC protein–protein interface. This analysis indicated a favorable binding mode for the KaiB monomer on the CII end of KaiC, involving two adjacent KaiC subunits and spanning an ATP binding cleft. A KaiC mutation, R468C, which has been shown to affect the affinity of KaiB for KaiC and lengthen the period in a bioluminescence rhythm assay, is found within the middle of the predicted KaiBC interface. The proposed KaiB binding mode blocks access to the ATP binding cleft in the CII ring of KaiC, which provides insight into how KaiB might influence the phosphorylation status of KaiC.

Villarreal, Seth A.↗

Identification and Distribution of Vanadinite (Pb[subscript 5](V[superscript 5+]O[subscript 4])[subscript 3]Cl) in Lead Pipe Corrosion By-Products

This study presents the first detailed look at vanadium (V) speciation in drinking water pipe corrosion scales. A pool of 34 scale layers from 15 lead or lead-lined pipes representing eight different municipal drinking water distribution systems in the Northeastern and Midwestern portions of the United States were examined. Diverse synchrotron-based techniques, including bulk XANES (X-ray absorption near edge spectroscopy), {mu}-XANES, {mu}-XRD (X-ray diffraction), and {mu}-XRF (X-ray fluorescence) mapping were employed along with traditional powder XRD, SEM-EDXA (scanning electron microscopy-energy dispersive X-ray analysis), and ICP-OES (inductively coupled plasma-optical emission spectrometry) to evaluate vanadium speciation and distribution in these deposits. Vanadinite (Pb{sub 5}(VO{sub 4}){sub 3}Cl) was positively identified, and occurred most frequently in the surface layers. Low V{sub tot} in these waters is likely the limiting factor in the abundance of vanadinite in the pipe scales, along with the existence of divalent lead. The occurrence of V in these samples as a discrete mineral is important because it is formed in the presence of very low concentrations of V in the finished water, it provides a mechanism to concentrate {mu}g{center_dot}L{sup -1} amounts of V from the water to near-percent levels in the pipe scales, and the robustness of V accumulation and release in response to water chemistry changes is likely different than it would be with a sorption accumulation mechanism. Extrapolation from limited existing water chemistry data in this study provides an estimate of {Delta}G{sub f}{sup o} for vanadinite as approximately -3443 kJ{center_dot}mol{sup -1}, or less, leading to a log K{sub s0} value of approximately -86 for the reaction Pb{sub 5}(VO{sub 4}){sub 3}CI{sub (s)}{r_reversible} {l_brace}Pb{sup 2+}{r_brace}{sup 5} + {l_brace}VO{sup 3-}{sub 4}{r_brace}{sup 3} + {l_brace}Cl{sup -}{r_brace}, in which {l_brace}{r_brace} denotes activity.

54 ENVIRONMENTAL SCIENCES↗

Probing the Local Site Disorder and Distortion in Pyrochlore High-Entropy Oxides

High-entropy oxides (HEOs) have attracted great interest in diverse fields because of their inherent opportunities to tailor and combine materials functionalities. The control of local order/disorder in the class is by extension a grand challenge toward realizing their vast potential. In this paper, we report the first examples of pyrochlore HEOs with five M-site cations, for Nd 2 M 2 O 7 , in which the local structure has been investigated by neutron diffraction and pair distribution function (PDF) analysis. The average structure of the pyrochlores is found to be orthorhombic Imma, in agreement with radius-ratio rules governing the structural archetype. The computed PDFs from density functional theory relaxed special quasirandom structure models are compared with real space PDFs in this work to evaluate M-site order/disorder. Reverse Monte Carlo combined with ab initio molecular dynamics and Metropolis Monte Carlo simulations demonstrates that Nd 2 (Ta 0.2 Sc 0.2 Sn 0.2 Hf 0.2 Zr 0.2 ) 2 O 7 is synthesized with its M-site local to nanoscale order highly randomized/disordered, while Nd 2 (Ti 0.2 Nb 0.2 Sn 0.2 Hf 0.2 Zr 0.2 ) 2 O 7+x exhibits a strong distortion of the TiO 6 octahedron and small degree of Ti chemical short-range order (SRO) on the subnanometer scale. Calculations suggest that this may be intrinsic, energetically favored SRO rather than due to sample processing. These results offer an important demonstration that the engineered variation of participating ions in HEOs, even among those with very similar radii, provides richly diverse opportunities to control local order/disorder motifs—and therefore materials properties for future designs. This work also hints at the exquisite level of detail that may be needed in computational and experimental data analysis to guide structure–property tuning in the emerging HEO materials class.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evidence for an Early Formation of Serenitatis Basin at 4.25 Ga Shifts Lunar Chronology

Troctolite sample 76535, collected in Serenitatis basin during Apollo 17, formed at least 50 km deep, experienced maximum shock pressures of 6 GPa, and has a 40 Ar/ 39 Ar excavation age of 4.25 Ga. Previous work attributed 76535 to the South Pole-Aitken (SPA) basin, presumably dating the SPA-impact and constraining lunar bombardment history. Here we use the iSALE-2D shock-physics code and gravity inversion modeling to determine if instead the Serenitatis impact event excavated 76535. We find nearly 140,000 km 3 of material (∼2% of near-surface ejecta) matching the depth and pressure constraints of 76535 is displaced to the surface during crater collapse of a Serenitatis-like impact event. We conclude that the Serenitatis impact event possibly excavated 76535, redefining its age to 4.25 Ga, 300 My older than the consensus age based on Apollo 17 samples. This finding would provide an important anchor point where lunar chronology where bombardment flux is especially uncertain.

Bjonnes, Evan [Lawrence Livermore National Laborat↗

Operation of a Free-Electron Laser from the Extreme Ultraviolet to the Water Window

We report results on the performance of a free-electron laser operating at a wavelength of 13.7 nm where unprecedented peak and average powers for a coherent extreme-ultraviolet radiation source have been measured. In the saturation regime, the peak energy approached 170 {micro}J for individual pulses, and the average energy per pulse reached 70 {micro}J. The pulse duration was in the region of 10 fs, and peak powers of 10 GW were achieved. At a pulse repetition frequency of 700 pulses per second, the average extreme-ultraviolet power reached 20mW. The output beam also contained a significant contribution from odd harmonics of approximately 0.6% and 0.03% for the 3rd (4.6 nm) and the 5th (2.75 nm) harmonics, respectively. At 2.75 nm the 5th harmonic of the radiation reaches deep into the water window, a wavelength range that is crucially important for the investigation of biological samples.

42 ENGINEERING↗

Nanoscale electric field imaging with an ambient scanning quantum sensor microscope

Nitrogen-vacancy (NV) center in diamond is a promising quantum sensor with remarkably versatile sensing capabilities. While scanning NV magnetometry is well-established, NV electrometry has been so far limited to bulk diamonds. Here we demonstrate imaging external alternating (AC) and direct (DC) electric fields with a single NV at the apex of a diamond scanning tip under ambient conditions. A strong electric field screening effect is observed at low frequencies. We quantitatively measure its frequency dependence and overcome this screening by mechanically oscillating the tip for imaging DC fields. Our scanning NV electrometry achieved an AC E-field sensitivity of 26 mV μm -1 Hz -1/2 , a DC E-field gradient sensitivity of 2 V μm -2 Hz -1/2 , and sub-100 nm resolution limited by the NV-sample distance. Our work represents an important step toward building a scanning-probe-based multimodal quantum sensing platform.

47 OTHER INSTRUMENTATION↗

Operando APXPS for direct probing of Li ion battery LCO electrode/electrolyte interface chemistry during lithiation/delithiation

The real-time interface chemistry between the lithium cobalt oxide (LCO) working electrode and the LiClO 4 /propylene carbonate (PC) electrolyte is investigated during lithiation/delithiation using dip-and-pull ambient pressure photoelectron spectroscopy (APXPS). The APXPS results appear to exhibit the seldom discussed Co 2+ state in the LCO structure, where the operando measurements indicate electron transfer among Co 2+ , Co 3+ , and Co 4+ states. Specifically, the lithiation of LCO reduces the Co 4+ state to both Co 3+ and Co 2+ states, where, as a function of voltage, reduction to the Co 2+ state is initially more pronounced followed by Co 3+ formation. In addition, a delay in surface delithiation is observed during the reverse potential steps. This is discussed in terms of overpotential at the interface measurement position as a consequence of the dip-and-pull setup for this experiment. Finally, the shifts in the apparent binding energies of the spectral features corresponding to the electrolyte and LCO at their interface show that the electrochemical potentials at delithiation voltage steps are different from the lithiation steps at the same applied voltages. This further explains the non-responsive delithiation. The BE shift observed from the LCO surface is argued to be dominantly due to the semi-conductive nature of the sample. Overall, this article shows the importance of operando APXPS for probing non-equilibrium states in battery electrodes for understanding electron transfer in the reactions.

Liu, Qianhui [Uppsala Univ. (Sweden)] (ORCID:00000↗

Natural radioactivity concentration of peanuts in Osmaniye-Turkey

The peanut is grown in Osmaniye where located in southern Turkey. Due to it is grown underground, the measurements of natural radioactivity of peanuts become important. For this reason some peanut samples have been collected from different places of Osmaniye and the measurements of natural activity concentrations for {sup 40}K, {sup 226}Ra and {sup 232}Th in some peanuts samples have been carried out using a NaI(Tl) gamma-ray spectrometer. Activity of {sup 40}K was measured from its intensive line at 1460 keV, for {sup 226}Ra activity peak from {sup 214}Bi at 1760 keV and {sup 232}Th activity, peak from {sup 208}Tl at energy of 2610 keV was used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BiPo: A dedicated radiopurity detector for the SuperNEMO experiment

New generation experiments in Astroparticle Physics need to operate in really restrictive background conditions, which implies the use of high radiopure materials for the experimental setup construction. For this reason the screening of the materials with enough sensitivity has become a challenge that sometimes cannot be afforded with standard techniques like Germanium detector spectroscopy. BiPo is a dedicated detector, that operates in the Canfranc Underground Laboratory, designed to measure the radiopurity, mainly of the ββ sources of the SuperNEMO experiment, by the detection of BiPo events. It is composed of two modules with 40 optical lines each one, registering the energy and the time of the emitted particles. The well known features of the BiPo events (delayed coincidence between an electron and an alpha particle) facilitate the discrimination of other background events that could entangle the expected signal. In addition, the geometry of the detector, with an active area of around 3.6 m{sup 2}, has been optimized to reach the necessary sensitivity levels for the SuperNEMO source foils in the shortest time possible. Preliminary results of background measurements and calibrations taken since summer 2012 shows that the required sensitivity for the measurements of the source foils could be reached in few months. Routine measurements of samples are already started being an important point for the SuperNEMO source foils construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗