Search NASA⌕ Search

SEARCH · Search NASA

Results for “Importance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Survey of techniques used to preserve biological materials

The techniques used to preserve biological materials are documented and summarized. The report is presented in a handbook format that categorizes the most important preservation techniques available, and includes a representative sampling of the thousands of applications of these techniques to biological materials and organisms. Details of the information coverage and method of approach are outlined. Data are given in tabular form, and an index and extensive bibliography are included.

Feinler, E. J.↗

The Relocation of Particulate Contamination During Space Flight

A computer simulation program to model the redistribution of particulate contaminants on a spacecraft after launch is developed. The component models for particulate adhesion, meteoroid impact, and electrostatic forces are described and intermediate results are presented. The results of a sample calculation show that the recontamination process is important.

Barengoltz, J.↗

Spacecraft recontamination

A computer simulation program to model the redistribution of particulate contaminants on a spacecraft after launch was developed. The component models for particulate adhesion, meteoroid impact, and electrostatic forces are described and intermediate results are presented. The results of a sample calculation show that the recontamination process is important.

Barengoltz, J.↗

Evaluation of an electro-optic remote displacement measuring system

An instrumentation system to provide a noncontact method for measurement of target positions was evaluated. The system employs two electro-optic camera units which give stereo information for use in determining three dimensional target locations. Specially developed, infrared sensitive photodetectors are used in the cameras to sense radiation from light emitting diode targets. Up to 30 of these targets can be monitored with a sampling rate of 312 Hz per target. An important part of the system is a minicomputer which is used to collect the camera data, sort it, make corrections for distortions in the electro-optic system, and perform the necesssary coordinate transformations. If target motions are restricted to locations in a plane which is perpendicular to a camera's optical axis, the system can be used with just one camera. Calibrations performed in this mode characterize accuracies in single camera operation. This information is also useful in determination of single camera contributions to total system errors. For this reason the system was tested in both the single camera and two camera (stereo) modes of operation.

Monteith, J. H.↗

Late skin damage in rabbits and monkeys after exposure to particulate radiations

Preliminary results are reported of experiments on the late effects of exposure to particulate radiations on stem cell populations. Skin biopsies were taken from the ears of rabbits irradiated 2-5 years previously with 530 MeV/amu Ar ions (LET 90 keV/micron), or 365 MeV/amu Ne ions (LET 35 keV micron), and from the chests and inner thighs of rhesus monkeys irradiated 16-18 years previously with 32-MeV protons (LET about 1.2 keV/micron). Skin fibroblast cultures obtained from the biopsy samples in rabbits were observed to undergo dose-dependent decreases in in vitro life span, with estimated survival curves showing the effects of Ar-ion irradiation to be more severe than those of Ne-ion irradiation. In addition, the healing of the biopsy wound was observed to become slower as radiation dose increased. In the monkey, radiation reduced the average number of fibroblasts at the time of cessation of growth in culture. Results thus demonstrate the capacity of skin sampling to reveal stem cell destruction, and have important implications for astronauts and other persons at risk of particle exposure with regard to healing responses to trauma or surgery.

Bergtold, D. S.↗

Problems with Re-Os isochron determinations

We have developed closed-system techniques for the equilibration of Os isotopes and for the calibration of Re and Os tracers using high-purity metals. The results show reproducibility of +/- 0.5% for calibrations of Os using different chunks of the same high-purity Os metal produced by vacuum arc melting. On a Re-Os evolution diagram the analyses of Negrillos and of Tocopilla are displaced along horizontal lines and are not consistent with a well-defined isochron. We conclude that is unclear whether whole-rock samples of irons of individual classes of iron meteorites (including the IIA class) define isochrons.In light of these observations, one must consider the evidence for phases in which Re and Os may become redistributed. We note that the IIA irons are composed of large or single kamacite crystals and do not contain taenite. This may hinder redistribution of Re and Os and may allow the IIA irons to define isochrons in preference to other magmatic iron classes. However, the IIA irons also include ubiquitous rhabdites, up to 20 mm in length, and troilite-daubreelite nodules. It has been observed that rhabdites are extremely rich in Pt-group elements. In addition to these considerations, Negrillos and Tocopilla were found in nitrate deposits and show evidence of corrosion. Therefore, it is possible that different samples of these meteorites have been differentially weathered, although our samples appeared fresh. We conclude that it is important to identify the phases in which Re and the PGEs are located and to address in detail the evidence for Re and Os remobilization.

Papanastassiou, D. A.↗

Wave-Like Perturbations Observed at Low Altitudes by the Pioneer Venus Orbiter Neutral Mass Spectrometer During Orbiter Entry

Wave-like perturbations have been observed in the nightside neutral density data acquired for He, N, O, N2 and CO2 by the Pioneer Venus Orbiter Neutral Mass Spectrometer (ONMS) during entry in late 1992. The data cover an altitude range of 133-200 km from 0.5-4.5 hours local solar time and occur at medium solar activity (F(sub 10.7) = 120) The perturbations, with an effective wavelength along the orbit of about 100 to 600 km, have similar amplitudes for the various species and helium is out of phase with respect to the heavier mass species. The measurements are comparable to those observed in 1978-80 at solar maximum activity (F(sub 10.7) = 200) above 145 km. Between 133 and 160 km the rms amplitudes grow with altitude at a rate of about (1.6, 2.1, 2.7, 4.4) x 10(exp -3)/ km for N, O, N2, and CO2 respectively. The average rms amplitudes above 145 km of 0.08 for N and O and 0.1 for N2 are comparable in magnitude to those observed in the earlier 1978-80 data of 0.06, 0.08 and 0.095 respectively. CO2 is an exception for which the entry value is 0.17 compared to 0.09 earlier. By combining the two overlapping data sets there is a suggestion that the CO2 amplitudes grow in value with altitude up to about 140-170 km and then decrease in amplitude. Like the earlier data, the entry data are consistent with the interpretation that the neutral density perturbations are due to gravity waves propagating upward from the lower thermosphere. Earlier data sampled a higher altitude region where dissipation is important in limiting and ultimately reversing the growth of gravity waves while the lower altitude entry data probed the region where growth of these waves can be observed.

Kasprzak, W. T.↗

Mineralogy of the Solar System

The coming decade will witnesses the first sample return missions from solar system bodies in 30 years. These samples will all be very small, some missions return only a few milligrams of total mass. Fortunately, the capability of modem methods to characterize ultra-small samples is well established from analysis of interplanetary dust particles (IDPs), interstellar grains recovered from meteorites, and other materials requiring ultra-sensitive analytical capabilities. Powerful analytical techniques are available that require, under favorable circumstances, single particles of only a few nanograms for entire suites of fairly comprehensive characterizations. A returned sample of greater than 1,000 particles with total mass of just one microgram permits comprehensive quantitative geochemical measurements that are impractical to can-y out in situ by flight instruments. With the Galileo flybys of Gaspra and Ida, it is now recognized that even very small airless bodies have indeed developed a particulate regolith. Acquiring a sample of the bulk regolith, a simple sampling strategy, provides two critical pieces of information about the body. Regolith samples are excellent bulk samples since they normally contain all the key components of the local environment, albeit in particulate form. Furthermore, since this fine fraction dominates remote measurements, regolith samples also provide information about surface alteration processes and are a key link to remote sensing of other bodies. Studies indicate that a statistically significant number of nanogram-sized particles should be able to characterize the regolith of a primitive asteroid, although the presence of larger components within even primitive meteorites (e.g.. Murchison), e.g. chondrules, CAI, large crystal fragments, etc., points out the limitations of using data obtained from nanogram-sized samples to characterize entire primitive asteroids. However, most important asteroidal geological processes have left their mark on the matrix, since this is the finest-grained portion and therefore most sensitive to chemical and physical changes. Thus, the following information can be learned from this fine grain size fraction alone: (1) mineral paragenesis; (2) regolith processes, (3) bulk composition; (4) conditions of thermal and aqueous alteration (if any); (5) relationships to planets, comets, meteorites (via isotopic analyses, including oxygen; (6) abundance of water and hydrated material; (7) abundance of organics; (8) history of volatile mobility, (9) presence and origin of presolar and/or interstellar material.

Zolensky, Michael E.↗

Constraints on the Energy Density Content of the Universe Using Only Clusters of Galaxies

We demonstrate that it is possible to constrain the energy content of the Universe with high accuracy using observations of clusters of galaxies only. The degeneracies in the cosmological parameters are lifted by combining constraints from different observables of galaxy clusters. We show that constraints on cosmological parameters from galaxy cluster number counts as a function of redshift and accurate angular diameter distance measurements to clusters are complementary to each other and their combination can constrain the energy density content of the Universe well. The number counts can be obtained from X-ray and/or SZ (Sunyaev-Zeldovich effect) surveys, the angular diameter distances can be determined from deep observations of the intra-cluster gas using their thermal bremsstrahlung X-ray emission and the SZ effect (X-SZ method). In this letter we combine constraints from simulated cluster number counts expected from a 12 deg2 SZ cluster survey and constraints from simulated angular diameter distance measurements based on using the X-SZ method assuming an expected accuracy of 7% in the angular diameter distance determination of 70 clusters with redshifts less than 1.5. We find that R, can be determined within about 25%, A within 20%, and w within 16%. Any cluster survey can be used to select clusters for high accuracy distance measurements, but we assumed accurate angular diameter distance measurements for only 70 clusters since long observations are necessary to achieve high accuracy in distance measurements. Thus the question naturally arises: How to select clusters of galaxies for accurate diameter distance determinations? In this letter, as an example, we demonstrate that it is possible to optimize this selection changing the number of clusters observed, and the upper cut off of their redshift range. We show that constraints on cosmological parameters from combining cluster number counts and angular diameter distance measurements, as opposed to general expectations, will not improve substantially selecting clusters with redshifts higher than one. This important conclusion allow us to restrict our cluster sample to clusters closer than one, in a range where the observational time for accurate distance measurements are more manageable. Subject headings: cosmological parameters - cosmology: theory - galaxies: clusters: general - X-rays: galaxies: clusters

Molnar, Sandor M.↗

Temperature-dependent Refractive Index of Silicon and Germanium

Silicon and germanium are perhaps the two most well-understood semiconductor materials in the context of solid state device technologies and more recently micromachining and nanotechnology. Meanwhile, these two materials are also important in the field of infrared lens design. Optical instruments designed for the wavelength range where these two materials are transmissive achieve best performance when cooled to cryogenic temperatures to enhance signal from the scene over instrument background radiation. In order to enable high quality lens designs using silicon and germanium at cryogenic temperatures, we have measured the absolute refractive index of multiple prisms of these two materials using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, as a function of both wavelength and temperature. For silicon, we report absolute refractive index and thermo-optic coefficient (dn/dT) at temperatures ranging from 20 to 300 K at wavelengths from 1.1 to 5.6 pin, while for germanium, we cover temperatures ranging from 20 to 300 K and wavelengths from 1.9 to 5.5 microns. We compare our measurements with others in the literature and provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures. Citing the wide variety of values for the refractive indices of these two materials found in the literature, we reiterate the importance of measuring the refractive index of a sample from the same batch of raw material from which final optical components are cut when absolute accuracy greater than k5 x 10" is desired.

Frey, Bradley J.↗

Analysis of Association Between Remotely Sensed (RS) Data and Soil Transmitted Helminthes Infection Using Geographical Information Systems (GIS): Boaco, Nicaragua

Soil-transmitted helminths are intestinal nematodes that can infect all members of a population but specially school-age children living in poverty. Infection can be significantly reversed with anthelmintic drug treatments and sanitation improvement. Implementation of effective public health programs requires reliable and updated information to identify areas at higher risk and to calculate amount of drug required. Geo-referenced in situ prevalence data will be overlaid over an ecological map derived from RS data using ARC Map 9.3 (ESRI). Prevalence data and RS data matching at the same geographical location will be analyzed for correlation and those variables from RS data that better correlate with prevalence will be included in a multivariate regression model. Temperature, vegetation, and distance to bodies of water will be inferred using data from Moderate-Resolution Imaging Spectroradiometer (MODIS) and Landsat TM and ETM+. Elevation will be estimated with data from The Shuttle Radar Topography Mission (SRTM). Prevalence and intensity of infections are determined by parasitological survey (Kato Katz) of children enrolled in rural schools in Boaco, Nicaragua, in the communities of El Roblar, Cumaica Norte, Malacatoya 1, and Malacatoya 2). This study will demonstrate the importance of an integrated GIS/RS approach to define sampling clusters without the need for any ground-based survey. Such information is invaluable to identify areas of high risk and to geographically target control programs that maximize cost-effectiveness and sanitation efforts.

MorenoMadrinan, Max J.↗

Apollo 16 Evolved Lithology Sodic Ferrogabbro

Evolved lunar igneous lithologies, often referred to as the alkali suite, are a minor but important component of the lunar crust. These evolved samples are incompatible-element rich samples, and are, not surprisingly, most common in the Apollo sites in (or near) the incompatible-element rich region of the Moon known as the Procellarum KREEP Terrane (PKT). The most commonly occurring lithologies are granites (A12, A14, A15, A17), monzogabbro (A14, A15), alkali anorthosites (A12, A14), and KREEP basalts (A15, A17). The Feldspathic Highlands Terrane is not entirely devoid of evolved lithologies, and rare clasts of alkali gabbronorite and sodic ferrogabbro (SFG) have been identified in Apollo 16 station 11 breccias 67915 and 67016. Curiously, nearly all pristine evolved lithologies have been found as small clasts or soil particles, exceptions being KREEP basalts 15382/6 and granitic sample 12013 (which is itself a breccia). Here we reexamine the petrography and geochemistry of two SFG-like particles found in a survey of Apollo 16 2-4 mm particles from the Cayley Plains 62283,7-15 and 62243,10-3 (hereafter 7-15 and 10-3 respectively). We will compare these to previously reported SFG samples, including recent analyses on the type specimen of SFG from lunar breccia 67915.

Zeigler, Ryan↗

Consistent Evaluation of ACOS-GOSAT, BESD-SCIAMACHY, CarbonTracker, and MACC Through Comparisons to TCCON

Consistent validation of satellite CO2 estimates is a prerequisite for using multiple satellite CO2 measurements for joint flux inversion, and for establishing an accurate long-term atmospheric CO2 data record. Harmonizing satellite CO2 measurements is particularly important since the differences in instruments, observing geometries, sampling strategies, etc. imbue different measurement characteristics in the various satellite CO2 data products. We focus on validating model and satellite observation attributes that impact flux estimates and CO2 assimilation, including accurate error estimates, correlated and random errors, overall biases, biases by season and latitude, the impact of coincidence criteria, validation of seasonal cycle phase and amplitude, yearly growth, and daily variability. We evaluate dry-air mole fraction (X(sub CO2)) for Greenhouse gases Observing SATellite (GOSAT) (Atmospheric CO2 Observations from Space, ACOS b3.5) and SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY) (Bremen Optimal Estimation DOAS, BESD v2.00.08) as well as the CarbonTracker (CT2013b) simulated CO2 mole fraction fields and the Monitoring Atmospheric Composition and Climate (MACC) CO2 inversion system (v13.1) and compare these to Total Carbon Column Observing Network (TCCON) observations (GGG2012/2014). We find standard deviations of 0.9, 0.9, 1.7, and 2.1 parts per million vs. TCCON for CT2013b, MACC, GOSAT, and SCIAMACHY, respectively, with the single observation errors 1.9 and 0.9 times the predicted errors for GOSAT and SCIAMACHY, respectively. We quantify how satellite error drops with data averaging by interpreting according to (error(sup 2) equals a(sup 2) plus b(sup 2) divided by n (with n being the number of observations averaged, a the systematic (correlated) errors, and b the random (uncorrelated) errors). a and b are estimated by satellites, coincidence criteria, and hemisphere. Biases at individual stations have year-to-year variability of 0.3 parts per million, with biases larger than the TCCON predicted bias uncertainty of 0.4 parts per million at many stations. We find that GOSAT and CT2013b under-predict the seasonal cycle amplitude in the Northern Hemisphere (NH) between 46 and 53 degrees North latitude, MACC over-predicts between 26 and 37 degrees North latitude, and CT2013b under-predicts the seasonal cycle amplitude in the Southern Hemisphere (SH). The seasonal cycle phase indicates whether a data set or model lags another data set in time. We find that the GOSAT measurements improve the seasonal cycle phase substantially over the prior while SCIAMACHY measurements improve the phase significantly for just two of seven sites. The models reproduce the measured seasonal cycle phase well except for at Lauder_125HR (CT2013b) and Darwin (MACC). We compare the variability within 1 day between TCCON and models in June-July-August; there is correlation between 0.2 and 0.8 in the NH, with models showing 10-50 percent the variability of TCCON at different stations and CT2013b showing more variability than MACC. This paper highlights findings that provide inputs to estimate flux errors in model assimilations, and places where models and satellites need further investigation, e.g., the SH for models and 45-67 degrees North latitude for GOSAT and CT2013b.

ACOS-GOSAT↗

Carbon Tracers of Aqueous Processes: Isotopic Analysis of Cr Carbonate Grains With Implications for Bennu Samples

Carbonate grains in carbonaceous chondrites record aqueous alteration events on the asteroidal parent bodies, including evidence for episodic alteration, timing of alteration, and time and temperature evolution of volatiles. Spectral features in the 3.4 μm region at asteroid Bennu have been interpreted as coming from carbonate minerals. Coordinated analysis of carbonate grains will be a valuable tool for analysis of Bennu samples, and related analysis of analog materials provides important context for understanding aqueous alteration of carbonaceous asteroids more broadly. To that end, our team is analyzing carbonates in Bennu analog materials, using Raman spectroscopy to identify carbonates and assess the maturity of related organic materials, vacuum reflectance spectroscopy from the ultraviolet through thermal infrared range to constrain contributions from carbonates and organics, X-ray microtomography and electron probe microanalysis (EPMA) to assess the distribution of void space, transmission electron microscopy to characterize space weathering effects, and EPMA and secondary ion mass spectrometry (SIMS) to measure composition and isotopic ratios. Here, we describe in situ analysis of carbon and oxygen isotopes from carbonates in Grosvenor Mountains (GRO) 95577.

K E Miller↗

Analyses of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4) Contamination Samples

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet (UV), x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen (AO). These environmental exposures can result in erosion, embrittlement and optical property degradation of susceptible materials threatening spacecraft performance and durability. To increase our understanding of environmental effects such as AO erosion and radiation induced embrittlement of spacecraft materials, NASA Glenn Research Center developed a series of experiments that were flown as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS). Recently, four Glenn experiments with 365 flight samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Each of these experiments included passive contamination witness samples in each flight direction for post-flight molecular contamination analyses. A total of 13 contamination flight samples were flown. The post-flight analyses of the PCE 1-4 contamination samples include X-ray Photoelectron Spectroscopy (XPS) analyses (surface and ion sputter depth analyses) and optical properties (total reflectance, total transmittance and solar absorptance). This paper provides results of post-flight analyses of the PCE 1-4 contamination samples and their corresponding control samples. Knowledge of on-orbit contamination is important for the PCE 1-4 flight data interpretation.

Atomic Oxygen↗

Membrane insertion for the detection of lipopolysaccharides: Exploring the dynamics of amphiphile-in-lipid assays

Shiga toxin-producing Escherichia coli is an important cause of foodborne illness, with cases attributable to beef, fresh produce and other sources. Many serotypes of the pathogen cause disease, and differentiating one serotype from another requires specific identification of the O antigen located on the lipopolysaccharide (LPS) molecule. The amphiphilic structure of LPS poses a challenge when using classical detection methods, which do not take into account its lipoglycan biochemistry. Typically, detection of LPS requires heat or chemical treatment of samples and relies on bioactivity assays for the conserved lipid A portion of the molecule. Our goal was to develop assays to facilitate the direct and discriminative detection of the entire LPS molecule and its O antigen in complex matrices using minimal sample processing. To perform serogroup identification of LPS, we used a method called membrane insertion on a waveguide biosensor, and tested three serogroups of LPS. The membrane insertion technique allows for the hydrophobic association of LPS with a lipid bilayer, where the exposed O antigen can be targeted for specific detection. Samples of beef lysate were spiked with LPS to perform O antigen specific detection of LPS from E. coli O157. To validate assay performance, we evaluated the biophysical interactions of LPS with lipid bilayers both in- and outside of a flow cell using fluorescence microscopy and fluorescently doped lipids. Our results indicate that membrane insertion allows for the qualitative and reliable identification of amphiphilic LPS in complex samples like beef homogenates. In addition, we also demonstrated that LPS-induced hole formation does not occur under the conditions of the membrane insertion assays. Together, these findings describe for the first time the serogroup-specific detection of amphiphilic LPS in complex samples using a membrane insertion assay, and highlight the importance of LPS molecular conformations in detection architectures.

59 BASIC BIOLOGICAL SCIENCES↗

Process Development of the Vaporizing Foil Actuator Welding Technique

The industrial focus on continuous improvement for products is leading design engineers to consider multi-material design concepts more frequently. The design concepts use the advantages of each material while simultaneously minimizing the drawbacks. It also allows for the overall weight of the products to be reduced. Some traditional joining methods, though, struggle to join dissimilar material combinations. A technique known as vaporizing foil actuator welding, which was developed around ten years ago, is a solid-state joining method that has the potential to overcome the barriers to dissimilar material joining. The biggest drawbacks of vaporizing foil actuator welding are that it is still exclusively used in laboratory settings and early in the technology development process. As such, there is not enough confidence in the process for it to be transitioned to manufacturing environments yet. This work begins by analyzing the current state of the technology and identifying a roadmap to achieve a transition to manufacturing. The analysis found that increased confidence in the technology requires sample to sample repeatability to be improved. Beyond that, the process also needs to be fully automated before it can be considered as a viable technique for mass production. In order to further develop the technique, a fully automated work cell was constructed. By removing the human element from the process, this cell helped identify iii the aspects which contribute to process variability. The positioning of the vaporizing foil actuator was identified as the most important factor in process stability. A small set of samples were made in the automated cell with the addition of one component epoxy adhesive around the perimeter of the weld. These samples showed improved process repeatability compared with the samples made without adhesive. This indicates that small amounts of adhesive may be critical in using the process in industrial settings. Additionally, work was performed with manual positioning and adhesive dispensing. This work found that a hybrid joint behaves like traditional weld bonding, where the addition of adhesive makes the joint stronger than if either of the two joining methods were used on their own. To realize this performance with vaporizing foil actuator welding, though, the adhesive needs to be protected from burning during the rapid compression of air during the impact process.

36 MATERIALS SCIENCE↗

Enhancement of the Magnetocaloric Effect in Composites Based on La{sub 0.4}Re{sub 0.1}Ca{sub 0.5}MnO{sub 3} (Re = Dy, Gd, and Eu) Polycrystalline Manganites

In this communication, we have used theoretical calculations in order to prepare a composite with an enhanced magnetocaloric effect from La{sub 0.4}Re{sub 0.1}Ca{sub 0.5}MnO{sub 3} (Re = Dy, Gd, and Eu) samples. Although the obtained composites did not exhibit very important values of magnetic entropy change (− ΔS), they are active in a very wide temperature range. One of the composites is characterized by a plateau-like shape of − ΔS(T) curves. Several anomalies were found in the magnetic and the magnetocaloric properties of our composites. The origin of these anomalies is essentially attributed to the phase separation phenomenon characterizing all the La{sub 0.4}Re{sub 0.1}Ca{sub 0.5}MnO{sub 3} samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗