Search NASA⌕ Search

SEARCH · Search NASA

Results for “Jefferson Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Niobium

The element niobium is often used as a superconductor. Watch as Jefferson Lab Staff Scientist Ari Palczewsi describes its characteristics and compares it to other metals.

36 MATERIALS SCIENCE↗

First results on nucleon resonance electroexcitation amplitudes from ep → e'π + π – p' cross sections at W = 1.4–1.7 GeV and Q 2 = 2.0–5.0 GeV 2

The electroexcitation amplitudes or $\gamma_vpN^*$ electrocouplings of the $N(1440)1/2^+$, $N(1520)3/2^-$, and $\Delta(1600)3/2^+$ resonances were obtained for the first time from the $ep \to e'\pi^+\pi^-p'$ differential cross sections measured with the CLAS detector at Jefferson Lab within the range of invariant mass $W$ of the final state hadrons from 1.4–1.7~GeV for photon virtualities $Q^2$ from 2.0--5.0~GeV$^2$. A good description of the nine independent one-fold differential $\gamma_v p\to \pi^+\pi^-p'$ cross sections achieved within the data-driven Jefferson Lab-Moscow State University (JM) meson-baryon reaction model in each bin of ($W$,$Q^2$) allows for separation of the resonant and non-resonant contributions. The electrocouplings were determined in the fits of the $\pi^+\pi^-p$ cross sections within three overlapping $W$ intervals with a substantial contribution from each of the three resonances listed above. Consistent results on the electrocouplings extracted from the data in these $W$ intervals provide evidence for their reliable extraction. These studies extend information on the electrocouplings of the $N(1440)1/2^+$ and $N(1520)3/2^-$ available from this channel over a broader range of $Q^2$. The electrocouplings of the $\Delta(1600)3/2^+$, which decays preferentially into $\pi\pi N$ final states, have been determined for the first time. Here, the reliable extraction of the electrocouplings for these states is also supported by the description of the $\pi^+\pi^-p$ differential cross sections with $Q^2$-independent masses and total/partial hadronic decay widths into the $\pi\Delta$ and $\rho p$ final states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First measurements of the {rho}{sup 3} spin density matrix elements in {gamma}p --> p {omega} using CLAS at JLAB

In an effort towards a ''complete'' experiment for the ω meson, we present studies from an experiment with an unpolarized target and a circularly polarized photon beam (g1c), carried out using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. The experiment was analyzed using an extended maximum likelihood fit with partial wave amplitudes. New likelihood functions were calculated to account for the polarization of the photon beam. Both circular and linear polarizations are explored. The results of these fits are then used to project out the spin density matrix for the {omega}. First measurements of the {rho}{sup 3} spin density matrix elements will be presented using this method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress on Optimization of the Nonlinear Beam Dynamics in the MEIC Collider Rings

One of the key design features of the Medium-energy Electron-Ion Collider (MEIC) proposed by Jefferson Lab is a small beta function at the interaction point (IP) allowing one to achieve a high luminosity of up to 10 34 cm -2 s -1 . The required strong beam focusing unavoidably causes large chromatic effects such as chromatic tune spread and beam smear at the IP, which need to be compensated. This paper reports recent progress in our development of a chromaticity correction scheme for the ion ring including optimization of dynamic aperture and momentum acceptance.

43 PARTICLE ACCELERATORS↗

Progress on optimization of the nonlinear beam dynamics in the MEIC collider rings

One of the key design features of the Medium-energy Electron-Ion Collider (MEIC) proposed by Jefferson Lab is a small beta function at the interaction point (IP) allowing one to achieve a high luminosity of up to 10 34 cm -2 s -1 . The required strong beam focusing unavoidably causes large chromatic effects such as chromatic tune spread and beam smear at the IP, which need to be compensated. This paper reports recent progress in our development of a chromaticity correction scheme for the ion ring including optimization of dynamic aperture and momentum acceptance.

43 PARTICLE ACCELERATORS↗

Update on the MEIC electron collider ring design

The electron collider ring of the Medium-energy Electron-Ion Collider (MEIC) at Jefferson Lab is designed to accumulate and store a high-current polarized electron beam for collisions with an ion beam. We consider a design of the electron collider ring based on reusing PEP-II components, such as magnets, power supplies, vacuum system, etc. This has the potential to significantly reduce the cost and engineering effort needed to bring the project to fruition. This paper reports on an electron ring optics design considering the balance of PEP-II hardware parameters (such as dipole sagitta, magnet field strengths and acceptable synchrotron radiation power) and electron beam quality in terms of equilibrium emittances.

43 PARTICLE ACCELERATORS↗

A measurement of the energy and timing resolution of GlueX Forward Calorimeter using an electron beam

The performance of the GlueX Forward Calorimeter was studied using a small version of the detector and a variable energy electron beam derived from the Hall B tagger at Jefferson Lab. For electron energies from 110 MeV to 260 MeV, which are near the lower-limits of the design sensitivity, the fractional energy resolution was measured to range from 20% to 14%, which meets the design goals. The use of custom 250 MHz flash ADCs for readout allowed precise measurements of signal arrival times. The detector achieved timing resolutions of 0.38 ns for a single 100 mV pulse, which will allow timing discrimination of photon beam bunches and out-of-time background during the operation of the GlueX detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Update on the MEIC electron collider ring design

The electron collider ring of the Medium-energy Electron-Ion Collider (MEIC) at Jefferson Lab is designed to accumulate and store a high-current polarized electron beam for collisions with an ion beam. We consider a design of the electron collider ring based on reusing PEPII components, such as magnets, power supplies, vacuum system, etc. This has the potential to significantly reduce the cost and engineering effort needed to bring the project to fruition. This paper reports on an electron ring optics design considering the balance of PEP-II hardware parameters (such as dipole sagitta, magnet field strengths and acceptable synchrotron radiation power) and electron beam quality in terms of equilibrium emittances.

43 PARTICLE ACCELERATORS↗

Status of the MEIC ion collider ring design

We present an update on the design of the ion collider ring of the Medium-energy Electron-Ion Collider (MEIC) proposed by Jefferson Lab. The design is based on the use of super-ferric magnets. It provides the necessary momentum range of 8 to 100 GeV/c for protons and ions, matches the electron collider ring design using PEP-II components, fits readily on the JLab site, offers a straightforward path for a future full-energy upgrade by replacing the magnets with higher-field ones in the same tunnel, and is more cost effective than using presently available current-dominated super-conducting magnets. We describe complete ion collider optics including an independently-designed modular detector region.

43 PARTICLE ACCELERATORS↗

Status of the MEIC ion collider ring design

We present an update on the design of the ion collider ring of the Medium-energy Electron-Ion Collider (MEIC) proposed by Jefferson Lab. The design is based on the use of super-ferric magnets. It provides the necessary momentum range of 8 to 100 GeV/c for protons and ions, matches the electron collider ring design using PEP-II components, fits readily on the JLab site, offers a straightforward path for a future full-energy upgrade by replacing the magnets with higher-field ones in the same tunnel, and is more cost effective than using presently available current-dominated superconducting magnets. We describe complete ion collider optics including an independently-designed modular detector region.

43 PARTICLE ACCELERATORS↗

Measurement of double polarized asymmetries in quasi-elastic processes ${}^3\vec{He}(\vec{e},e' d)$ and ${}^3\vec{He}(\vec{e},e' p)$

This thesis is dedicated to a study of a spin-isospin structure of the polarized 3 He. First, an introduction to the spin structure of 3 He is given, followed by a brief overview of past experiments. The main focus of the thesis is the E05-102 experiment at Jefferson Lab, in which the reactions ${}^3\vec{He}(\vec{e},e' d)$ and ${}^3\vec{He}(\vec{e},e' p)$ in the quasi-elastic region were studied. The purpose of this experiment was to better understand the effects of the S'- and D-state contributions to the 3 He ground-state wave-functions by a precise measurement of beam-target asymmetries A x and A z in the range of recoil momenta from 0 to about 300 MeV/c. The experimental equipment utilized in these measurements is described, with special attention devoted to the calibration of the hadron spectrometer, BigBite. Results on the measured asymmetries are presented, together with first attempts at their comparison to the state-of-the art Faddeev calculations. The remaining open problems and challenges for future work are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conceptual MEIC electron ring injection scheme using CEBAF as a full energy injector

The Medium-energy Electron-Ion Collider (MEIC) proposed by Jefferson Lab is planning to use the newly upgraded 12 GeV CEBAF 1497 MHz SRF CW recirculating linac as a full-energy injector for the electron collider ring. The electron collider ring is proposed to reuse the 476 MHz PEP-II RF system to achieve high installed voltage and high beam power. The MEIC electron injection requires 3-10 (or 12) GeV beam in 3-4µs long bunch trains with low duty factor and high peak current, resulting in strong transient beam loading for the CEBAF. In this paper, we propose an injection scheme that can match the two systems' frequencies with acceptable injection time, and also address the transient beam loading issue in CEBAF. The scheme is compatible with future upgrade to 952.6 MHz SRF system in the electron ring.

43 PARTICLE ACCELERATORS↗

Determination of the Al 27 Neutron Distribution Radius from a Parity-Violating Electron Scattering Measurement

In this paper, we report the first measurement of the parity-violating elastic electron scattering asymmetry on 27 Al. The 27 Al elastic asymmetry is $A_{\text{PV}}$ = 2.16 ± 0.11(stat) ± 0.16(syst) ppm, and was measured at $\langle Q^2\rangle$ = 0.02357 ± 0.00010 GeV$^2$, $\angleθ_{\text{lab}}$ = 7.61° ± 0.02°, and $\langle E_{\text{lab}}$ = 1.157 GeV with the Q weak apparatus at Jefferson Lab. Predictions using a simple Born approximation as well as more sophisticated distorted-wave calculations are in good agreement with this result. From this asymmetry the 27 Al neutron radius $R_n$ = 2.89 ± 0.12 fm was determined using a many-models correlation technique. The corresponding neutron skin thickness $R_n – R_p$ = –0.04 ± 0.12 fm is small, as expected for a light nucleus with a neutron excess of only 1. This result thus serves as a successful benchmark for electroweak determinations of neutron radii on heavier nuclei. A tree-level approach was used to extract the 27 Al weak radius $R_w$ = 3.00 ± 0.15 fm, and the weak skin thickness $R_{\text{wk}} – R_{\text{ch}}$ = –0.04 ± 0.15 fm. The weak form factor at this $Q^2$ is $F_{\text{wk}}$ = 0.39 ± 0.04.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The 12 GeV Energy Upgrade at Jefferson Laboratory

Two new cryomodules and an extensive upgrade of the bending magnets at Jefferson Lab has been recently completed in preparation for the full energy upgrade in about one year. Jefferson Laboratory has undertaken a major upgrade of its flagship facility, the CW re-circulating CEBAF linac, with the goal of doubling the linac energy to 12 GeV. I will discuss here the main scope and timeline of the upgrade and report on recent accomplishments and the present status. I will then discuss in more detail the core of the upgrade, the new additional C100 cryomodules, their production, tests and recent successful performance. I will then conclude by looking at the future plans of Jefferson Laboratory, from the commissioning and operations of the 12 GeV CEBAF to the design of the MEIC electron ion collider.

43 PARTICLE ACCELERATORS↗

Polarization Experiments with Electromagnetic Probes (Final Technical Report)

The grant started in 1989 and finished on 31 July, 2018. The PI (Vina Punjabi) with many Norfolk State University (NSU) undergraduate students, and several research associates have been involved in many research activity during this period. NSU is primarily a minority institution. The PI has worked with one or two students every year, most of the students involved in her research went on to graduate schools to pursue degrees in physics, applied physics or engineering. One of the most important goal of the PI’s research activity has been involving NSU physics undergraduate students in forefront nuclear and particle physics research. (List of students and research associates is given in Appendix I). Over the years the PI, students and research associates participated in many research activity, however there are two main projects where the PI has been involved as one of the project leader. (1) Investigation of the structure of the deuteron at Saturne national lab in Saclay, France and at Laboratory of High Energy (LHE), part of the Joint Institute of Nuclear Research (JINR) lab in Dubna, Russia. (2) Measurement of the ratio of electric to magnetic form factors of the proton , GEp/GMp at Jefferson Lab, to study the internal structure of the proton.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Magnetized Electron Source For Ion Beam Cooling

A number of electron-ion collider facilities for nuclear physics research are under consid- eration in the United States. At Brookhaven National Lab (BNL), the eRHIC (electron Relativistic Heavy Ion Collider) facility would augment the existing ion/proton facility with an electron accelerator. Thomas Jefferson National Accelerator Facility (JLab) plans to use the existing CEBAF machine and add an ion/proton accelerator, as part of the Jefferson Lab Electron-Ion Collider (JLEIC). All such facilities require cooling of the ion beams in order to reach the luminosity goals. Different methods of cooling the ions using an electron beam are envisaged. BNL is pursuing coherent electron cooling and non-magnetized, bunched-beam cooling, while JLab is considering magnetized cooling. In addition to electron cooling, magnetized beams are of interest for other applica- tions, such as flat beam klystrons and novel means for producing bright beams for micro- undulators and compact X-ray sources. For example, flat beams generated from a mag- netized injector, in conjunction with low emittance, enable RF sources with frequencies above 100 GHz. While the market for high-performance injectors for electron cooling is limited, the market for high-frequency RF sources and compact X-ray systems is con- siderable. Thus, the design methodologies developed in this project have a wide range of applicability. In Phase I of this SBIR project, Xelera Research LLC performed simulations and calcu- lations to develop a prototype design for a magnetized electron injector that can be used as a source for cooling an ion beam. We developed general design methodologies and tech- niques that are applicable not only to specific machine designs but to other applications requiring magnetized injectors as well. In this Phase II SBIR project, Xelera Research LLC, in collaboration with a team at JLab, designed, built, and tested a thermionic elec- tron source for driving a magnetized electron cooler in a future electron-ion collider project. This device was delivered to JLab in July 2019 and achieved first beam in December 2019.

43 PARTICLE ACCELERATORS↗

Accelerator Transport Lattice Design Issues for High Performance ERLs

We will discuss issues in the design, construction, and operation of accelerator lattices for use in ERLs. These include phase space quality preservation during generation, acceleration, and transport of high-power, high-brightness beams, appropriate configuration of beam properties for synchrotron radiation users across a spectral range spanning THz to X-ray, beam handling during energy recovery, management of instabilities and "stray" power arising from the beam's coupling to itself and to environmental impedances and wakes, and provision for large acceptance (through the use of appropriate nonlinear optics) for the control of degraded "spent" beam and suppression of halo-driven beam loss. Experience derived from Jefferson Lab operation of five ERLs - across an energy range of 20 MeV to 1 GeV - will be described. Notice: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. The U.S. Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce this manuscript for U.S. Government purposes.

Benson, Stephen↗

Spin Structure of the Nucleon - Status and Recent Results

After the initial discovery of the so-called "spin crisis in the parton model" in the 1980s, a large set of polarization data in deep inelastic lepton-nucleon scattering was collected at labs like SLAC, DESY and CERN. More recently, new high precision data at large $x$ and in the resonance region have come from experiments at Jefferson Lab. These data, in combination with the earlier ones, allow us to study in detail the polarized parton densities, the $Q^2$ dependence of various moments of spin structure functions, the duality between deep inelastic and resonance data, and the nucleon structure in the valence quark region. Together with complementary data from HERMES, RHIC and COMPASS, we can put new limits on the flavor decomposition and the gluon contribution to the nucleon spin. In this report, we provide an overview of our present knowledge of the nucleon spin structure and give an outlook on future experiments. We focus in particular on the spin structure functions $g_

43 PARTICLE ACCELERATORS↗