Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

SU-F-BRB-15: Dosimetric Study of Radiation Therapy for Head/Neck Patients with Metallic Dental Fixtures

Purpose: To investigate the dose contributions of scattered electrons from dental amalgams during head and neck radiotherapy, and to evaluate the protective role of dosimetric dental stents during treatment to prevent oral mucositis. Methods: A phantom was produced to accurately simulate the oral cavity and head. The oral cavity consisted of a tissue equivalent upper and lower jaw and complete set of teeth. A set of 4 mm ethylene copolymer dosimetric stents was made for the upper and lower teeth. Five removable gold caps were fitted to apposing right molars, and the phantom was crafted to accomodate horizontal and vertical film for 2D dosimetry and NanoDot dosimeter for recording point doses. The head was simulated using a small cylindrical glass water bath. CT simulation was performed on the phantom with and without metal fittings and, in each case, with and without the dental stent. The CT image sets were imported into Eclipse treatment planning system for contouring and treatment planning, and a 9-field IMRT treatment plan was developed for each scenario. These plans were delivered using a Varian TrueBeam linear accelerator. Doses were recorded using GafChromic EBT2 films and NanoDot dosimeters. Results: The measurements revealed a 43% relative increase in dose measured adjacent to the metal fixtures in the horizontal plane without the use of the dental stent. This equates to a total dose of 100 Gy to the oral mucosa during a standard course of definitive radiotherapy. To our knowledge, this is the first dosimetric analysis of dental stents using an anatomically realistic phantom and modern beam arrangement. Conclusion: These results support the use of dosimetric dental stents in head and neck radiotherapy for patients with metallic dental fixtures as a way to effectively reduce dose to nearby mucosal surfaces and, hence, reduce the risk and severity of mucositis.

60 APPLIED LIFE SCIENCES↗

3D treatment planning on helical tomotherapy delivery system

The helical tomotherapy is a technologically advanced radiation dose delivery system designed to perform intensity-modulated radiation therapy (IMRT). It is mechanistically unique, based on a small 6-MV linear accelerator mounted on a ring gantry that rotates around the patient while the patient moves through a bore, ultimately yielding a helical path of radiation dose delivery. The helical pattern of dose delivery differentiated tomotherapy from other contemporary radiation therapy systems at the time of its inception. The accompanying 3-dimensional (3D) treatment planning system has been developed to solely support this specific type of dose delivery system. The treatment planning system has 2 modules identified as TomoHelical and TomoDirect to perform IMRT and conformal radiation therapy, respectively. The focus of this work within the scope of this special issue on 3D treatment planning systems is to assess the use of planning tools to generate treatment plans for helical tomotherapy. Clinical examples are used throughout to demonstrate the quality and differences of various clinical scenarios planned with tomotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-235: Monte Carlo Analysis of the Dose Enhancement in the Scalp of Patients Due to Titanium Plate Backscatter During Post-Operative Radiotherapy

Purpose: To quantify the clinically observed dose enhancement adjacent to cranial titanium fixation plates during post-operative radiotherapy. Methods: Irradiation of a titanium burr hole cover was simulated using Monte Carlo code MCNPX for a 6 MV photon spectrum to investigate backscatter dose enhancement due to increased production of secondary electrons within the titanium plate. The simulated plate was placed 3 mm deep in a water phantom, and dose deposition was tallied for 0.2 mm thick cells adjacent to the entrance and exit sides of the plate. These results were compared to a simulation excluding the presence of the titanium to calculate relative dose enhancement on the entrance and exit sides of the plate. To verify simulated results, two titanium burr hole covers (Synthes, Inc. and Biomet, Inc.) were irradiated with 6 MV photons in a solid water phantom containing GafChromic MD-55 film. The phantom was irradiated on a Varian 21EX linear accelerator at multiple gantry angles (0–180 degrees) to analyze the angular dependence of the backscattered radiation. Relative dose enhancement was quantified using computer software. Results: Monte Carlo simulations indicate a relative difference of 26.4% and 7.1% on the entrance and exit sides of the plate respectively. Film dosimetry results using a similar geometry indicate a relative difference of 13% and -10% on the entrance and exit sides of the plate respectively. Relative dose enhancement on the entrance side of the plate decreased with increasing gantry angle from 0 to 180 degrees. Conclusion: Film and simulation results demonstrate an increase in dose to structures immediately adjacent to cranial titanium fixation plates. Increased beam obliquity has shown to alleviate dose enhancement to some extent. These results are consistent with clinically observed effects.

60 APPLIED LIFE SCIENCES↗

SU-E-T-322: The Evaluation of the Gafchromic EBT3 Film in Low Dose 6 MV X-Ray Beams with Different Scanning Modes

Purpose: We have evaluated the response of the Gafchromic EBT3 film in low dose for 6 MV x-ray beams with two scanning modes, the reflection scanning mode and the transmission scanning mode. Methods: We irradiated the Gafcromic EBT3 film using a 60 degree enhanced dynamic wedge (EDW) with 6 MV x-ray beams from Clinac iX Linear accelerator (Varian Medical Systems, Palo Alto, CA). The irradiated Gafchromic EBT3 film was scanned with different scanning modes, the reflection scanning mode and the transmission scanning mode. The scanned Gafchromic EBT3 film was analyzed with MATLAB. Results: When 7.2 cGy was irradiated to the Gafchromic EBT3 film, the uncertainty was 0.54 cGy with reflection scanning mode and was 0.88 cGy with transmission scanning mode. When 24 cGy was irradiated to the Gafchromic EBT3 film, the uncertainty was similar to the case of 7.2 cGy irradiation showing 0.51 cGy of uncertainty with reflection scanning mode and 0.87 cGy of uncertainty with transmission scanning mode. The result suggests that the reflection mode should be used in Gafchromic EBT3 film for low irradiation. Conclusion: The result suggests that the reflection mode should be used in Gafchromic EBT3 film for low irradiation.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 49: Unexpected Output Drops: Pitted Blackholes in Tungsten

During the daily measurement of radiation output of a 6 MV beam on a Varian Trilogy Linear Accelerator the output dropped below 2% and initiated a call to action by physics to determine the cause. Over the course of weeks the cause of the issue was diagnosed to be a defect in the target, resulting in a drop in output and an asymmetry of the beam. Steps were taken to return the machine to clinical service while parts were on order while ensuring the safety of patient treatment. The machine target was replaced and the machine continues to operate as expected. A drop in output is usually a rarity and a defect in the target is possibly more rare. This experience demonstrated the importance of routine QC measurement, recording and analyzing daily output and symmetry values. In addition, this event showcased the importance of a multi-disciplinary approach in a high-pressure situation to effectively troubleshoot unique events to ensure consistence, safety patient treatment.

60 APPLIED LIFE SCIENCES↗

Measurements of Prompt Radiation-Induced Conductivity of Pyralux®

In this report, measurements of the prompt radiation-induced conductivity (RIC) in 3 mil samples of Pyralux® are presented as a function of dose rate, pulse width, and applied bias. The experiments were conducted with the Medusa linear accelerator (LINAC) located at the Little Mountain Test Facility (LMTF) near Ogden, UT. The nominal electron energy for the LINAC is 20 MeV. Prompt conduction current data were obtained for dose rates ranging from ~2 x 10 9 rad(Si)/s to ~1.1 x 10 11 rad(Si)/s and for nominal pulse widths of 50 ns and 500 ns. At a given dose rate, the applied bias across the samples was stepped between -1500 V and 1500 V. Calculated values of the prompt RIC varied between 1.39x10 -8 Ω -1 · m -1 and 2.67x10 -7 Ω -1 · m -1 and the prompt RIC coefficient varied between 1.25x10 -18 Ω -1 · m -1 /(rad/s) and 1.93x10 -17 Ω -1 · m -1 /(rad/s).

36 MATERIALS SCIENCE↗

Dosimetric Accuracy of a Dual Photon Energy Linac at Low Monitor Setting for Various Pulse Repetition Frequencies

Accuracy of dose delivery at low monitor unit setting is studied for a dual photon energy linear accelerator. Dose delivered per MU is found to be constant for both the photon beams for MU settings above 30. For lower MUs there is definite deviation from the calibrated value and the error is found to be increasing as fewer MUs are set for dose delivery. This dose/MU ratio at low MU setting is found to be dose-rate dependent, showing an increasing trend with pulse repetition frequency (PRF). Also, the dosimetric ratio is observed to be mode dependent; its value for an 18 MV beam is almost double that observed in the case of a 6 MV beam at very low MU setting. The magnitude of this error should be determined for each energy so that appropriate corrections can be applied if very low MUs are to be used.

61 RADIATION PROTECTION AND DOSIMETRY↗

Poster — Thur Eve — 25: Sensitivity to inhomogeneities for an in-vivo EPID dosimetry method

Introduction: The electronic portal imaging device (EPID) has the potential to be used for in vivo dosimetry during radiotherapy as an additional dose delivery check. We recently proposed a simple method of using the EPID for 2D-IVD based on correlation ratios. In this work we have investigated the sensitivity of our EPID-IVD to inhomogeneities. Methods: We used slab phantoms that simulate water, bone, and lung, arranged in various geometries. To simulate body contours non-orthogonal to the field, we used a water wedge. CT data of these phantoms was imported into MATLAB, in conjunction with EPID images acquired during irradiation, to calculate dose inside the phantom in isocenter plane. Each phantom was irradiated using a linear accelerator while images were acquired with the EPID (cine mode). Comparisons between EPID-calculated and TPS dose maps were: pixel-by-pixel dose difference, and 3%,3mm gamma evaluation. Results: In the homogeneous case, CAX dose difference was <1%, and 3%,3mm gamma analysis yielded 99% of points with gamma<1. For the inhomogeneous phantoms, agreement decreased with increasing inhomogeneity reaching up to 10% CAX dose difference with 10cm of lung. Results from the water wedge phantom suggest that the EPID-calculated dose can account for surface irregularities of approximately ±3cm. Conclusions: The EPID-based IVD investigated has limitations in the presence of large inhomogeneities. Nonetheless, CAX doses never differed by >15% from the TPS. This suggests that this EPID-IVD is capable of detecting gross dose delivery errors even in the presence of inhomogeneities, supporting its utility as an additional patient safety device.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP1-03: Pre-Treatment Surface Imaging Based Collision Detection

Purpose: Modern radiotherapy increasingly employs large immobilization devices, gantry attachments, and couch rotations for treatments. All of which raise the risk of collisions between the patient and the gantry / couch. Collision detection is often achieved by manually checking each couch position in the treatment room and sometimes results in extraneous imaging if collisions are detected after image based setup has begun. In the interest of improving efficiency and avoiding extra imaging, we explore the use of a surface imaging based collision detection model. Methods: Surfaces acquired from AlignRT (VisionRT, London, UK) were transferred in wavefront format to a custom Matlab (Mathworks, Natick, MA) software package (CCHECK). Computed tomography (CT) scans acquired at the same time were sent to CCHECK in DICOM format. In CCHECK, binary maps of the surfaces were created and overlaid on the CT images based on the fixed relationship of the AlignRT and CT coordinate systems. Isocenters were added through a graphical user interface (GUI). CCHECK then compares the inputted surfaces to a model of the linear accelerator (linac) to check for collisions at defined gantry and couch positions. Note, CCHECK may be used with or without a CT. Results: The nominal surface image field of view is 650 mm × 900 mm, with variance based on patient position and size. The accuracy of collision detections is primarily based on the linac model and the surface mapping process. The current linac model and mapping process yield detection accuracies on the order of 5 mm, assuming no change in patient posture between surface acquisition and treatment. Conclusions: CCHECK provides a non-ionizing method to check for collisions without the patient in the treatment room. Collision detection accuracy may be improved with more robust linac modeling. Additional gantry attachments (e.g. conical collimators) can be easily added to the model.

60 APPLIED LIFE SCIENCES↗

Monitoring external beam radiotherapy using real-time beam visualization

Purpose: To characterize the performance of a novel radiation therapy monitoring technique that utilizes a flexible scintillating film, common optical detectors, and image processing algorithms for real-time beam visualization (RT-BV). Methods: Scintillating films were formed by mixing Gd{sub 2}O{sub 2}S:Tb (GOS) with silicone and casting the mixture at room temperature. The films were placed in the path of therapeutic beams generated by medical linear accelerators (LINAC). The emitted light was subsequently captured using a CMOS digital camera. Image processing algorithms were used to extract the intensity, shape, and location of the radiation field at various beam energies, dose rates, and collimator locations. The measurement results were compared with known collimator settings to validate the performance of the imaging system. Results: The RT-BV system achieved a sufficient contrast-to-noise ratio to enable real-time monitoring of the LINAC beam at 20 fps with normal ambient lighting in the LINAC room. The RT-BV system successfully identified collimator movements with sub-millimeter resolution. Conclusions: The RT-BV system is capable of localizing radiation therapy beams with sub-millimeter precision and tracking beam movement at video-rate exposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating dose to implantable cardioverter-defibrillator outside the treatment fields using a skin QED diode, optically stimulated luminescent dosimeters, and LiF thermoluminescent dosimeters

The purpose of this work was to determine the relative sensitivity of skin QED diodes, optically stimulated luminescent dosimeters (OSLDs) (microStar Trade-Mark-Sign DOT, Landauer), and LiF thermoluminescent dosimeters (TLDs) as a function of distance from a photon beam field edge when applied to measure dose at out-of-field points. These detectors have been used to estimate radiation dose to patients' implantable cardioverter-defibrillators (ICDs) located outside the treatment field. The ICDs have a thin outer case made of 0.4- to 0.6-mm-thick titanium ({approx}2.4-mm tissue equivalent). A 5-mm bolus, being the equivalent depth of the devices under the patient's skin, was placed over the ICDs. Response per unit absorbed dose-to-water was measured for each of the dosimeters with and without bolus on the beam central axis (CAX) and at a distance up to 20 cm from the CAX. Doses were measured with an ionization chamber at various depths for 6- and 15-MV x-rays on a Varian Clinac-iX linear accelerator. Relative sensitivity of the detectors was determined as the ratio of the sensitivity at each off-axis distance to that at the CAX. The detector sensitivity as a function of the distance from the field edge changed by {+-} 3% (1-11%) for LiF TLD-700, decreased by 10% (5-21%) for OSLD, and increased by 16% (11-19%) for the skin QED diode (Sun Nuclear Corp.) at the equivalent depth of 5 mm for 6- or 15-MV photon energies. Our results showed that the use of bolus with proper thickness (i.e., {approx}d{sub max} of the photon energy) on the top of the ICD would reduce the scattered dose to a lower level. Dosimeters should be calibrated out-of-field and preferably with bolus equal in thickness to the depth of interest. This can be readily performed in clinic.

61 RADIATION PROTECTION AND DOSIMETRY↗

Systematic evaluation of photodetector performance for plastic scintillation dosimetry

Purpose: The authors’ objective was to systematically assess the performance of seven photodetectors used in plastic scintillation dosimetry. The authors also propose some guidelines for selecting an appropriate detector for a specific application. Methods: The plastic scintillation detector (PSD) consisted of a 1-mm diameter, 10-mm long plastic scintillation fiber (BCF-60), which was optically coupled to a clear 10-m long optical fiber of the same diameter. A light-tight plastic sheath covered both fibers and the scintillator end was sealed. The clear fiber end was connected to one of the following photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens), a monochromatic camera with an optical lens, a PIN photodiode, an avalanche photodiode (APD), or a photomultiplier tube (PMT). A commercially available W1 PSD was also included in the study, but it relied on its own fiber and scintillator. Each PSD was exposed to both low-energy beams (120, 180, and 220 kVp) from an orthovoltage unit and high-energy beams (6 and 23 MV) from a linear accelerator. Various dose rates were tested to identify the operating range and accuracy of each photodetector. Results: For all photodetectors, the relative uncertainty was less than 5% for dose rates higher than 3 mGy/s. The cameras allowed multiple probes to be used simultaneously, but they are less sensitive to low-light signals. The PIN, APD, and PMT had higher sensitivity, making them more suitable for low dose rate and out-of-field dose monitoring. The relative uncertainty of the PMT was less than 1% at the lowest dose rate achieved (0.10 mGy/s), suggesting that it was optimal for use in live dosimetry. Conclusions: For dose rates higher than 3 mGy/s, the PIN diode is the most effective photodetector in terms of performance/cost ratio. For lower dose rates, such as those seen in interventional radiology or high-gradient radiotherapy, PMTs are the optimal choice.

60 APPLIED LIFE SCIENCES↗

SU-E-T-105: An FMEA Survey of Intensity Modulated Radiation Therapy (IMRT) Step and Shoot Dose Delivery Failure Modes

Purpose: To assess the perception of TG-142 tolerance level dose delivery failures in IMRT and the application of FMEA process to this specific aspect of IMRT. Methods: An online survey was distributed to medical physicists worldwide that briefly described 11 different failure modes (FMs) covered by basic quality assurance in step- and-shoot IMRT at or near TG-142 tolerance criteria levels. For each FM, respondents estimated the worst case H&N patient percent dose error and FMEA scores for Occurrence, Detectability, and Severity. Demographic data was also collected. Results: 181 individual and three group responses were submitted. 84% were from North America. Most (76%) individual respondents performed at least 80% clinical work and 92% were nationally certified. Respondent medical physics experience ranged from 2.5–45 years (average 18 years). 52% of individual respondents were at least somewhat familiar with FMEA, while 17% were not familiar. Several IMRT techniques, treatment planning systems and linear accelerator manufacturers were represented. All FMs received widely varying scores ranging from 1–10 for occurrence, at least 1–9 for detectability, and at least 1–7 for severity. Ranking FMs by RPN scores also resulted in large variability, with each FM being ranked both most risky (1st ) and least risky (11th) by different respondents. On average MLC modeling had the highest RPN scores. Individual estimated percent dose errors and severity scores positively correlated (p<0.10) for each FM as expected. No universal correlations were found between the demographic information collected and scoring, percent dose errors, or ranking. Conclusion: FMs investigated overall were evaluated as low to medium risk, with average RPNs less than 110. The ranking of 11 FMs was not agreed upon by the community. Large variability in FMEA scoring may be caused by individual interpretation and/or experience, thus reflecting the subjective nature of the FMEA tool.

60 APPLIED LIFE SCIENCES↗

SU-C-BRB-03: Novel Technique to Implement GRID Therapy in a Commercial Treatment Planning System

Purpose: Due to the difficulty of creating an accurate multi-aperture block in treatment planning systems (TPS), spatially fractionated radiation therapy (GRID Therapy) is limited to clinical setups using simple monitor unit calculations. In this work, we present a novel approach to accurately model a grid block in a TPS and evaluate its dosimetric accuracy. Methods: An acrylic GRID block was fashioned such that the hole size and spacing were the same dimensions of the brass GRID block (dotDecimal) at isocenter. Holes were non-divergent and drilled 1 cm deep. CT scans (RT Lightspeed, GE Healthcare) of the block were acquired using axial slices with a thickness of 0.625 mm. These were imported into Eclipse (version 11, Varian Medical Systems) and holes were auto-contoured into structures. The GRID block was created in Eclipse by forming apertures around the hole structures using a simple three step process. Treatment plans were created in a water-equivalent phantom using 6 and 10 MV beams, delivered with a linear accelerator (Clinac iX, Varian Medical Systems) and measured using a water tank, film and a diode array. Results: Comparisons of percent depth dose curves and profiles at depths of maximum dose, 5cm, and 10cm for field sizes ranging from 5 cm{sup 2} to 25 cm{sup 2} using water and film were within 3% of their respective positions in Eclipse. GRID plans utilizing various jaw sizes and MLC blocking measured with film and a diode array showed pass rates with an average of 97% using Gamma analysis at 3%/ 3 mm and no lower than 93%. Conclusion: We have developed a simple yet accurate method of incorporating a GRID block into a commercially available TPS and demonstrated that the TPS accurately reflects the dose delivered. This will allow for real-time planning using patient scans and encourage new methods for GRID therapy. Support provided by dotDecimal, Sanford, FL.

60 APPLIED LIFE SCIENCES↗

SU-E-T-81: A Study On Correlation Between Gamma Analysis for Midline and Lateralized Tumors Using VMAT

Purpose: To evaluate the fluence for the midline and lateralized tumors for VMAT technique using 2D seven29 detector array combined with the Octavius phantom. Methods: 60 cases that are already being treated with volumetric modulated arc therapy (VMAT) have selected for this study. This includes tumors situated at the medial and lateral. Medial refers to the tumor situated at the midline of the body and lateral means toward the side or away from the midline of the body. Verification plans were created for each treatment plan in Varian Eclipse treatment planning system (version10, Varian medical systems, Palo Alto,CA) with the 2D Seven29 detector array and the Octavius phantom(PTW, Freiburg, Germany). Measurements were performed on a Varian Clinac 2100 iX, linear accelerator equipped with a millennium 120 leaf collimator. Analysis was done by comparing the fluence measured for the tumors situated on the midline and tumors situated laterally. Results: Fluence measured for all the delivered plans were analyzed using Verisoft software (PTW, Freiburg, Germany). The gamma pass percentage for midline tumors were found to be higher compared with the lateralized ones. The standard deviation between gamma values for midline and lateralized tumors is 2.18 and 3.5 respectively. Also the standard deviation between the point doses for midline and lateralized tumors is 0.38 and 0.29 respectively. The average gamma passing rate for midline tumors is 96.55% and for lateralized tumors are 94.94% for 3%DD and 3mm DTA criteria. From the T test, it was found that there is no significant difference between the gamma pass percentage between midline and lateralized tumors with p value of 0.28. Conclusion: There is no particular correlation found in the gamma pass criteria for midline and lateralized tumors.

60 APPLIED LIFE SCIENCES↗

SU-E-J-105: Stromal-Epithelial Responses to Fractionated Radiotherapy

Purpose: The stromal-epithelial-cell interactions that are responsible for directing normal breast-tissue development and maintenance play a central role in the progression of breast cancer. In the present study, we developed three-dimensional (3-D) cell co-cultures used to study cancerous mammary cell responses to fractionated radiotherapy. In particular, we focused on the role of the reactive stroma in determining the therapeutic ratio for postsurgical treatment. Methods: Cancerous human mammary epithelial cells were cultured in a 3-D collagen matrix with human fibroblasts stimulated by various concentrations of transforming growth factor beta 1 (TGF-β1). These culture samples were designed to model the post-lumpectomy mammary stroma in the presence of residual cancer cells. We tracked over time the changes in medium stiffness, fibroblast-cell activation (conversion to cancer activated fibroblasts (CAF)), and proliferation of both cell types under a variety of fractionated radiotherapy protocols. Samples were exposed to 6 MV X-rays from a linear accelerator in daily fraction sizes of 90, 180 and 360 cGy over five days in a manner consistent with irradiation exposure during radiotherapy. Results: We found in fractionation studies with fibroblasts and CAF that higher doses per fraction may be more effective early on in deactivating cancer-harboring cellular environments. Higher-dose fraction schemes inhibit contractility in CAF and prevent differentiation of fibroblasts, thereby metabolically uncoupling tumor cells from their surrounding stroma. Yet, over a longer time period, the higher dose fractions may slow wound healing and increase ECM stiffening that could stimulate proliferation of surviving cancer cells. Conclusion: The findings suggest that dose escalation to the region with residual disease can deactivate the reactive stroma, thus minimizing the cancer promoting features of the cellular environment. Large-fraction irradiation may be used to sterilize residual tumor cells and inhibit activation of intracellular transduction pathways that are promoted during the post-surgical woundhealing period. NIH award R01CA138882.

60 APPLIED LIFE SCIENCES↗

TH-C-19A-10: Systematic Evaluation of Photodetectors Performances for Plastic Scintillation Dosimetry

Purpose: To assess and compare the performance of different photodetectors likely to be used in a plastic scintillation detector (PSD). Methods: The PSD consists of a 1 mm diameter, 10 mm long plastic scintillation fiber (BCF-60) which is optically coupled to a clear 10 m long optical fiber of the same diameter. A light-tight plastic sheath covers both fibers and the scintillator end is sealed. The clear fiber end is connected to one of the following six studied photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens); a monochromatic camera with the same optical lens; a PIN photodiode; an avalanche photodiode (APD); and a photomultiplier tube (PMT). Each PSD is exposed to both low energy beams (120, 180, and 220 kVp) from an orthovoltage unit, and high energy beams (6 MV and 23 MV) from a linear accelerator. Various dose rates are explored to identify the photodetectors operating ranges and accuracy. Results: For all photodetectors, the relative uncertainty remains under 5 % for dose rates over 3 mGy/s. The taper camera collects four times more signal than the optical lens camera, although its standard deviation is higher since it could not be cooled. The PIN, APD and PMT have higher sensitivity, suitable for low dose rate and out-of-field dose monitoring. PMT's relative uncertainty remains under 1 % at the lowest dose rate achievable (50 μGy/s), suggesting optimal use for live dosimetry. Conclusion: A set of 6 photodetectors have been studied over a broad dose rate range at various energies. For dose rate above 3 mGy/s, the PIN diode is the most effective photodetector in term of performance/cost ratio. For lower dose rate, such as those seen in interventional radiology, PMTs are the optimal choice. FQRNT Doctoral Research Scholarship.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-100: Designing a QA Tool for Enhance Dynamic Wedges Based On Dynalog Files

Purpose: A robust quality assurance (QA) program for computer controlled enhanced dynamic wedge (EDW) has been designed and tested. Calculations to perform such QA test is based upon the EDW dynamic log files generated during dose delivery. Methods: Varian record and verify system generates dynamic log (dynalog) files during dynamic dose delivery. The system generated dynalog files contain information such as date and time of treatment, energy, monitor units, wedge orientation, and type of treatment. It also contains the expected calculated segmented treatment tables (STT) and the actual delivered STT for the treatment delivery as a verification record. These files can be used to assess the integrity and precision of the treatment plan delivery. The plans were delivered with a 6 MV beam from a Varian linear accelerator. For available EDW angles (10°, 15°, 20°, 25°, 30°, 45°, and 60°) Varian STT values were used to manually calculate monitor units for each segment. It can also be used to calculate the EDW factors. Independent verification of fractional MUs per segment was performed against those generated from dynalog files. The EDW factors used to calculate MUs in TPS were dosimetrically verified in solid water phantom with semiflex chamber on central axis. Results: EDW factors were generated from the STT provided by Varian and verified against practical measurements. The measurements were in agreement of the order of 1 % to the calculated EDW data. Variation between the MUs per segment obtained from dynalog files and those manually calculated was found to be less than 2%. Conclusion: An efficient and easy tool to perform routine QA procedure of EDW is suggested. The method can be easily implemented in any institution without a need for expensive QA equipment. An error of the order of ≥2% can be easily detected.

60 APPLIED LIFE SCIENCES↗