Two-dimensional unsteady lift problems in supersonic flight
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Highlights: ► Combined downflow and upflow water addition improved hydraulic conductivity. ► Upflow water addition unclogged perforated screen leading to more leachate flow. ► The volume of water added and transmitted positively correlated with hydrolysis process. ► Combined downflow and upflow water addition increased COD production and yield. ► Combined downflow and upflow leachate recycle improved leachate and COD production. - Abstract: Poor performance of leachbed reactors (LBRs) is attributed to channelling, compaction from waste loading, unidirectional water addition and leachate flow causing reduced hydraulic conductivity and leachate flow blockage. Performance enhancement was evaluated in three LBRs M, D and U at 22 ± 3 °C using three water addition and leachate recycle strategies; water addition was downflow in D throughout, intermittently upflow and downflow in M and U with 77% volume downflow in M, 54% volume downflow in U while the rest were upflow. Leachate recycle was downflow in D, alternately downflow and upflow in M and upflow in U. The strategy adopted in U led to more water addition (30.3%), leachate production (33%) and chemical oxygen demand (COD) solubilisation (33%; 1609 g against 1210 g) compared to D (control). The total and volatile solids (TS and VS) reductions were similar but the highest COD yield (g-COD/g-TS and g-COD/g-VS removed) was in U (1.6 and 1.9); the values were 1.33 and 1.57 for M, and 1.18 and 1.41 for D respectively. The strategy adopted in U showed superior performance with more COD and leachate production compared to reactors M and D.
This presentation describes the results of the demonstration of a non-flow-through PEM fuel cell as part of a power system on the SCARAB rover at the NASA Glenn Research Center. A 16-cell non-flow-through fuel cell stack from Infinity Fuel Cell and Hydrogen, Inc. was incorporated into a power system designed to act as a range extender by providing power to the SCARAB rover s hotel loads. The power system, including the non-flow-through fuel cell technology, successfully demonstrated its goal as a range extender by powering hotel loads on the SCARAB rover, making this demonstration the first to use the non-flow-through fuel cell technology on a mobile platform.
Voltage optimization refers to a volt-var optimization technique which was originally designed to minimize energy consumption and improve end-use efficiency on the distribution system. This reduces source voltage at a substation, which lowers generation demand, reduces system losses, and improves system stability. This has been the conventional implementation of voltage optimization: focusing on regulation of voltages throughout the distribution system via coordinated adjustments of load tap changers, line-voltage regulators, switched shunt compensation, and the targeted placement of new shunt compensation. These methods have received increased focus following a growth in distributed-energy resources (DERs) interconnecting at the distribution level, given their developing capability to participate in voltage regulation. This is paired with the intermittency challenges they pose, load imbalances, and voltage fluctuations. Voltage optimization has long been an area of extensive research within the distribution system, with various strategies and philosophies demonstrating a range of effects. The conventional focus on the distribution system owes to the typical operation of transmission systems, which assumes firm local resources and flows strictly from generation resources to loads. The strategies employed in distribution have also been optimized for this typically radial configuration and operation of the distribution system.
The cost of solar collectors constitutes almost one third of the total cost of a CSP plant. One of the ongoing challenges in the design of these collectors is wind loading on mirrors, support structures, and drives. A particular challenge is dynamic wind loading, caused by the turbulent wind flow. To date, the design of solar collector structures has relied on wind tunnel experiments and numerical simulations that do not entirely capture the dynamic effects observed at scale. The CSP industry has shown increased interest in validating the idealized assumptions with measurements obtained in operational settings to improve wind load assumptions and increase reliability and cost-efficiency of the collector design. Further, performance models need realistic assumptions about wind loading and its impact on optical performance. In a parabolic trough field campaign, NREL successfully collected a wealth of long-term, high-resolution wind and loads data [2], that are publicly available and that can be used for the above-mentioned purposes. Heliostats are impacted differently by wind than parabolic troughs, due to their different shape, size, and field layout. To study the impact of wind and turbulence on heliostats, we initiated another field campaign in an operational power- tower plant, Crescent Dunes, in Nevada, USA. In this work, we present an overview of the measurements, first results, and potential implications of wind driven loads on Heliostats.
A controller for a series hybrid capillary pumped loop (CPL) system that requires no moving parts does not resrict fluid flow has been tested and has demonstrated improved performance characteristics over a plain CPL system and simple hybrid CPL systems. These include heat load sharing, phase separation, self-regulated flow control and distribution, all independent of most system pressure drop. In addition, the controlled system demonstrated a greater heat transport capability than the simple CPL system but without the large fluid inventory requirement of the hybrid systems. A description of the testing is presented along with data that show the advantages of the system.
Controllable solid propulsion systems have distinctive combustion and acoustic environments that require enhanced testing and analysis techniques to progress this new technology from development to production. In a hot gas valve actuating system, the movement of the pintle through the hot gas exhibits complex acoustic disturbances and flow characteristics that can amplify induced pressure loads that can damage or detonate the rocket motor. The geometry of a controllable solid propulsion gas chamber can set up unique unsteady flow which can feed acoustic oscillations patterns that require characterization. Research in this area aids in the understanding of how best to design, test, and analyze future controllable solid rocket motors using the lessons learned from past government programs as well as university research and testing. This survey paper will give the reader a better understanding of the potentially amplifying affects propagated by a controllable solid rocket motor system and the knowledge of the tools current available to address these acoustic disturbances in a preliminary design. Finally the paper will supply lessons learned from past experiences which will allow the reader to come away with understanding of what steps need to be taken when developing a controllable solid rocket propulsion system. The focus of this survey will be on testing and analysis work published by solid rocket programs and from combustion and acoustic books, conference papers, journal articles, and additionally from subject matter experts dealing currently with controllable solid rocket acoustic analysis.
Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.
Several flight-critical aerodynamic problems such as buffet, flutter, stall, and wing rock are strongly affected or caused by abrupt changes in unsteady aerodynamic loads and moments. Advanced sensing and flow diagnostic techniques have made possible simultaneous identification and tracking, in realtime, of the critical surface, viscosity-related aerodynamic phenomena under both steady and unsteady flight conditions. The wind tunnel study reported here correlates surface hot-film measurements of leading edge stagnation point and separation point, with unsteady aerodynamic loads on a NACA 0015 airfoil. Lift predicted from the correlation model matches lift obtained from pressure sensors for an airfoil undergoing harmonic pitchup and pitchdown motions. An analytical model was developed that demonstrates expected stall trends for pitchup and pitchdown motions. This report demonstrates an ability to obtain unsteady aerodynamic loads in real time, which could lead to advances in air vehicle safety, performance, ride-quality, control, and health management.
Several flight-critical aerodynamic problems such as buffet, flutter, stall, and wing rock are strongly affected or caused by abrupt changes in unsteady aerodynamic loads and moments. Advanced sensing and flow diagnostic techniques have made possible simultaneous identification and tracking, in real-time, of the critical surface, viscosity-related aerodynamic phenomena under both steady and unsteady flight conditions. The wind tunnel study reported here correlates surface hot-film measurements of leading edge stagnation point and separation point, with unsteady aerodynamic loads on a NACA 0015 airfoil. Lift predicted from the correlation model matches lift obtained from pressure sensors for an airfoil undergoing harmonic pitchup and pitchdown motions. An analytical model was developed that demonstrates expected stall trends for pitchup and pitchdown motions. This report demonstrates an ability to obtain unsteady aerodynamic loads in real-time, which could lead to advances in air vehicle safety, performance, ride-quality, control, and health management.
In the design analysis of conventional aircraft configurations, the prediction of the strong interaction between vortical wakes and the viscous flow field about bodies is of considerable importance. Interactions between vortical wakes and aircraft components are even more common on rotorcraft and configurations with lifting surfaces forward of the wing. An accurate analysis of the vortex-wake interaction with aircraft components is needed for the optimization of the payload and the reduction of vibratory loads. However, the three-dimensional flow field beneath the rotor disk and the interaction of the rotor wake with solid bodies in the flow field are highly complex. The present paper has the objective to provide a basis for the considered interactions by studying a simpler problem. This problem involves the two-dimensional interaction of external wakes with the viscous flow about a circular cylinder.
As part of the Soils Activity of the Environmental Management Operations at the NNSA, Nevada Field Office, radionuclide-contaminated Soils sites will undergo regulatory closure in accordance with the 1996 Nevada Federal Facilities Agreement and Consent Order. One closure alternative that has been evaluated for each Soils site has been -closure-in-place- with fencing and posting, along with administrative controls. However, potential disturbance agents for radionuclide-contaminated soils left in place are possible erosion and transport by wind and water. Previous work with radionuclide-contaminated soils has indicated that the highest activity levels of Pu tend to be found in the fine sands, silts, or clays, which are the most likely particle sizes to be transported by wind re-suspension, and by runoff flow events. Monitoring and sampling stations have been deployed at specific Soils sites to collect meteorological data, airborne particulate filter samples, and both suspended and bed-load sediment transport samples during and after runoff flow events, as needed. The primary objective of the air monitoring and sampling stations is to evaluate whether there is wind transport of radionuclide-contaminated soils from Soils sites. The primary objective of the precipitation and runoff flow data collection, as well as both suspended and bed-load sediment sampling, is to determine during which rainfall events (i.e., precipitation return interval, duration, and intensity) radionuclide-contaminated soils are likely to be transported. The NNSS continues to demonstrate compliance with US DOE Order 458.1 for the Radiation Protection of the Public and the Environment, as reported in annual environmental reports. (authors)
Dynamic compression tests were conducted using a split Hopkinson pressure bar along the transverse direction at strain rates (SRs) of 3200 and 6000 s{sup −1}. The initial microstructure significantly affected the flow stress behavior and microstructural evolution of the two studied AM80 magnesium alloys. Under the same SR loading, the as-extruded alloy exhibited an apparently higher flow stress. At a SR of 6000 s{sup −1}, the flow stress of the as-extruded alloy exhibited a visible decrease (~ 34 MPa) as the strain increased to ~ 0.2, whereas a constant flow stress was exhibited by the solution-treated alloy. High-density dislocations and mechanical twins were detected in the two alloys at a SR of 3200 s{sup −1}. Interestingly, dynamic recrystallization (DRX) with an average grain size of ~ 2 µm was only identified in the as-extruded alloy as the applied SR increased to 6000 s{sup −1}. The increased localized deformation in the as-extruded alloy due to the retained strain energy and high critical twinning stress improved the DRX driving force, thereby resulting in visibly different micrographs of the two alloys when impacted at the SR of 6000 s{sup −1}.
We propose a branch flow model for the analysis and optimization of mesh as well as radial networks. The model leads to a new approach to solving optimal power flow (OPF) that consists of two relaxation steps. The first step eliminates the voltage and current angles and the second step approximates the resulting problem by a conic program that can be solved efficiently. For radial networks, we prove that both relaxation steps are always exact, provided there are no upper bounds on loads. For mesh networks, the conic relaxation is always exact but the angle relaxation may not be exact, and we provide a simple way to determine if a relaxed solution is globally optimal. We propose convexification of mesh networks using phase shifters so that OPF for the convexified network can always be solved efficiently for an optimal solution. We prove that convexification requires phase shifters only outside a spanning tree of the network and their placement depends only on network topology, not on power flows, generation, loads, or operating constraints. Part I introduces our branch flow model, explains the two relaxation steps, and proves the conditions for exact relaxation. Part II describes convexification of mesh networks, and presents simulation results.
We propose a branch flow model for the analysis and optimization of mesh as well as radial networks. The model leads to a new approach to solving optimal power flow (OPF) that consists of two relaxation steps. The first step eliminates the voltage and current angles and the second step approximates the resulting problem by a conic program that can be solved efficiently. For radial networks, we prove that both relaxation steps are always exact, provided there are no upper bounds on loads. For mesh networks, the conic relaxation is always exact but the angle relaxation may not be exact, and we provide a simple way to determine if a relaxed solution is globally optimal. We propose convexification of mesh networks using phase shifters so that OPF for the convexified network can always be solved efficiently for an optimal solution. We prove that convexification requires phase shifters only outside a spanning tree of the network and their placement depends only on network topology, not on power flows, generation, loads, or operating constraints. Part I introduces our branch flow model, explains the two relaxation steps, and proves the conditions for exact relaxation. Part II describes convexification of mesh networks, and presents simulation results.
Splitter blades as a passive flutter control technique is investigated by developing a mathematical model to predict the stability of an aerodynamically loaded splittered-rotor operating in an incompressible flow field. The splitter blades, positioned circumferentially in the flow passage between two principal blades, introduce aerodynamic and/or combined aerodynamic-structural detuning into the rotor. The two-dimensional oscillating cascade unsteady aerodynamics, including steady loading effects, are determined by developing a complete first-order unsteady aerodynamic analysis together with an unsteady aerodynamic influence coefficient technique. The torsion mode flutter of both uniformly spaced tuned rotors and detuned rotors are predicted by incorporating the unsteady aerodyamic influence coefficients into a single-degree-of-freedom aeroelastic model. This model is then utilized to demonstrate that incorporating splitters into unstable rotor configurations results in stable splittered-rotor configurations.
This excel file provides direct use geothermal data for various wells located in Oregon. Data includes well name, location, heating application, temperature and flow of fluid, capacity, energy use, and load factor. The data is from the State of Oregon Department of Geology and Mineral Industries (linked below), where additional data downloads and metadata may be found.
Dynamic and quasi-static compression experiments are conducted on a high-density porous titanium with in situ X-ray imaging to characterize its deformation dynamics. The porous titanium exhibits higher strain-rate sensitivity than full-density titanium. Strain field mapping indicates that compaction bands are narrower and denser under dynamic loading, leading to a more homogeneous strain distribution and thus a higher flow stress. Here, the mean Poisson's ratio for dynamic loading is 15% lower than that for quasi-static loading at the same bulk strain, as a result of local inertial confinement which also contributes to the rate hardening of porous titanium.