Rapid, high power, dense plasma jet delivery system for critical magnetic fusion problems
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract Not Provided
Abstract Not Provided
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
An existing Magnetic Suspension and Balance System (MSBS) has been restored to operation in a small (octagonal test section, 6-inches across flats) low-speed wind tunnel as the first phase of a project to develop new dynamic test capabilities for planetary entry capsules at supersonic speeds. The MSBS and associated wind tunnel were originally designed and built at MIT and were subsequently relocated to NASA Langley Research Center. NASA ceased operations of the system in the late 1990s and it was transferred to Old Dominion University where it had been mothballed until the present work started in 2015. All-new position sensor electronics, electromagnet power supplies, digital controller, and other hardware have been developed, leading to more efficient and reliable operation. Important features of the new hardware will be briefly described. Wind tunnel testing has commenced, focusing first on static aerodynamics of re-entry capsule shapes. Some preliminary results will be reviewed, including comparison to reference data. The proposed extension to dynamic stability testing, using a variety of free-to-pitch approaches will be described. Finally, the preliminary design of the all-new Phase II (supersonic) system will be briefly outlined.
The technology which is required to allow the principles of magnetic suspension and balance systems (MSBS) to be applied to the high Reynolds number transonic testing of aircraft models is examined. A test facility is presented as comprising a pressurized transonic cryogenic wind tunnel, with the MSBS providing full six degree of freedom control. The electro-magnets which are superconducting and fed from quiet, bipolar power supplies are examined. A model control system having some self adaptive characteristics is discussed.
The objectives are to experimentally confirm several advanced design concepts on the Magnetic Suspension and Balance Systems (MSBS). The advanced design concepts were identified as potential improvements by Madison Magnetics, Inc. (MMI) during 1984 and 1985 studies of an MSBS utilizing 14 external superconductive coils and a superconductive solenoid in an airplane test model suspended in a wind tunnel. This study confirmed several advanced design concepts on magnetic suspension and balance systems. The 1989 MSBS redesign is based on the results of these experiments. Savings of up to 30 percent in supporting magnet ampere meters and 50 percent in energy stored over the 1985 design were achieved.
We report on the magnetic and structural properties of IrMn/CoFe exchange bias systems deposited onto a dual seed layer of NiCr(X)/Ru(5 nm), with X=2, 6, and 20 nm. Samples with the structure NiCr (Xnm)/IrMn (7 nm)/CoFe (3 nm)/Ta (10 nm) with X=2, 6, and 20 nm were prepared by dc sputtering for magnetic characterization. A second set of samples with structure NiCr (Xnm)/IrMn (10 nm) with X=2, 6, and 20 nm were deposited onto TEM grids for structural characterization by TEM. A method of manipulating of the TEM grid to allow a qualitative analysis of the in-plane texture of the samples is described and used to analyze the microstructure of these samples. The microstructure and particularly the texture are correlated with the anisotropy constant (K{sub AF}) of the antiferromagnet (AF) layer, with an optimum NiCr seed layer of 6 nm to give a maximum value of K{sub AF} of 1.2x10{sup 7} ergs/cc.
An all digital five channel position detection system is to be installed in the Southampton University Magnetic Suspension and Balance System (SUMSBS). The system is intended to monitor a much larger range of model pitch attitudes than has been possible hitherto, up to a maximum of a 90 degree angle of attack. It is based on the use of self-scanning photodiode arrays and illuminating laser light beams, together with purpose built processing electronics. The principles behind the design of the system are discussed, together with the results of testing one channel of the system which was used to control the axial position of a magnetically suspended model in SUMSBS. The removal of optically coupled heave position information from the axial position sensing channel is described.
This review article describes the performance of the magnetic field measuring and monitoring systems for the Compact Muon Solenoid (CMS) detector. To cross-check the magnetic flux distribution obtained with the CMS magnet model, four systems for measuring the magnetic flux density in the detector volume were used. The magnetic induction inside the 6 m diameter superconducting solenoid was measured and is currently monitored by four nuclear magnetic resonance (NMR) probes installed using special tubes outside the barrel hadron calorimeter. Two more NRM probes were installed at the faces of the tracking system. The field inside the superconducting solenoid was precisely measured in 2006 in a cylindrical volume of 3.448 m in diameter and 7 m in length using 10 three-dimensional (3D) B-sensors based on the Hall effect. These B-sensors were installed on each of the two propeller arms of an automated field-mapping machine. In addition to these measurement systems, a system for monitoring the magnetic field during the CMS detector operation has been developed. Inside the solenoid in the horizontal plane, 4 3D B-sensors were installed at the faces of the tracking detector. Twelve 3D B-sensors were installed on the surfaces of the flux-return yoke nose disks. Seventy 3D B-sensors were installed in the air gaps of the CMS magnet yoke. A specially developed flux loop technique was used for the most complex measurements of the magnetic flux density inside the steel blocks of the CMS magnet yoke. The flux loops are installed in 22 sections of the flux-return yoke blocks. The areas enclosed by these coils varied from 0.3 to 1.59 m$^{2}$ in the blocks of the barrel wheels and from 0.5 to 1.12 m$^{2}$ in the blocks of the yoke endcap disks. The development of these systems and the results of the magnetic flux density measurements across the CMS magnet are presented and discussed in this review article.
Recent developments and current research efforts leading towards realization of a large scale production wind tunnel Magnetic Suspension and Balance facility are reviewed. Progress has been made in the areas of model roll control, high angle-of-attack testing, digital system control, high magnetic moment superconducting solenoid model cores, and system failure tolerance. Formal design studies of large scale facilities have commenced and are continuing.
To investigate the effect of magnetic resonance system- and patient-induced susceptibility distortions from a 3T scanner on dose distributions for prostate cancers.
A few specific developments that were undertaken recently to the magnetic suspension and balance system (MSBS) are detailed. The improvements are as follows: modifications to the digital control system to accommodate a modified position sensing system; development of pressure telemetry systems; and revisions to the wind tunnel test section.
The problems of wind tunnel testing are outlined, with attention given to the problems caused by mechanical support systems, such as support interference, dynamic-testing restrictions, and low productivity. The basic principles of magnetic suspension are highlighted, along with the history of magnetic suspension and balance systems. Roll control, size limitations, high angle of attack, reliability, position sensing, and calibration are discussed among the problems and limitations of the existing magnetic suspension and balance systems. Examples of the existing systems are presented, and design studies for future systems are outlined. Problems specific to large-scale magnetic suspension and balance systems, such as high model loads, requirements for high-power electromagnets, high-capacity power supplies, highly sophisticated control systems and position sensors, and high costs are assessed.
The high-frequency absorption of electromagnetic radiation in systems with a noncollinear spatial magnetization distribution has been calculated. A medium with a helicoidal magnetic structure and a superlattice whose period contains two layers with noncollinear magnetizations are considered. An additional absorption peak related to the electron transitions from one spin subband to another under the action of a variable linearly polarized electric field is shown to appear in such systems at frequencies near the spin splitting of the conduction band.