Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC DIPOLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Observing Charge Separation Distance in Organic Donor-Acceptors with Photoinduced Absorption Detected Magnetic Resonance Spectroscopy

The debatable role of charge transfer states in photoinduced charge separation to useful free carriers has been a long-standing controversy in the field of organic solar cells. In this work, varying charge-pair distances are measured in sensitized donor-acceptor thin films using a photoinduced absorption-detected magnetic resonance (PADMR) technique where nearest-neighbor charge transfer states are identified by their strong magnetic dipole-coupling relative to more distant charges. Correlation with the direct measurement of free carriers using time-resolved microwave conductivity has corroborated a distributed-range electron transfer model in which charges generated at longer distances become free carriers, while shorter transfer distances give only bound charge transfer states that cannot separate to generate photocurrent.

charge transfer↗

HTS Accelerator Magnets Conceptual Design for Future Lepton Colliders

There is an interest in designing superconducting magnet systems for future lepton circular colliders. This application requires many low-field iron-dominated dipole and quadrupole magnets. Conventional room-temperature magnets are often used because of their low field, low total current, and low power losses. However, high electricity bills for large accelerators drive magnet design to superconductivity. High-temperature superconducting (HTS) magnets can substantially reduce energy losses in magnet systems. The present study investigated the conceptual design of HTS dipole and quadrupole magnets operating in persistent current mode. Energy is transferred into the magnet from an external detachable power source. A continuously circulating current generates a stable magnetic field. The iron-dominated magnet system concept was investigated using OPERA3D code, and the results confirmed the proposed approach’s validity.

43 PARTICLE ACCELERATORS↗

Antenna radiation patterns in the whistler wave regime measured in a large laboratory plasma

Antenna radiation patterns of balanced electric dipoles and shielded magnetic loop antennas are obtained by measuring the relative wave amplitude with a small receiver antenna scanned around the exciter in a large uniform collisionless magnetized laboratory plasma in the whistler wave regime. The boundary effects are assumed to be negligible even for many farfield patterns. Characteristic differences are observed between electrically short and long antennas, the former exhibiting resonance cones and the latter showing dipole-like antenna patterns along the magnetic field. Resonance cones due to small electric dipoles and magnetic loops are observed in both the near zone and the far zone. A self-focusing process is revealed which produces a pencil-shaped field-aligned radiation pattern.

Stenzel, R. L.↗

Triaxial Probe Magnetic Data Analysis

The Triaxial Magnetic Moment Analysis software uses measured magnetic field test data to compute dipole and quadrupole moment information from a hardware element. It is used to support JPL projects needing magnetic control and an understanding of the spacecraft-generated magnetic fields. Evaluation of the magnetic moment of an object consists of three steps: acquisition, conditioning, and analysis. This version of existing software was extensively rewritten for easier data acquisition, data analysis, and report presentation, including immediate feedback to the test operator during data acquisition. While prior JPL computer codes provided the same data content, this program has a better graphic display including original data overlaid with reconstructed results to show goodness of fit accuracy and better appearance of the report graphic page. Data are acquired using three magnetometers and two rotations of the device under test. A clean acquisition user interface presents required numeric data and graphic summaries, and the analysis module yields the best fit (least squares) for the magnetic dipole and/or quadrupole moment of a device. The acquisition module allows the user to record multiple data sets, selecting the best data to analyze, and is repeated three times for each of the z-axial and y-axial rotations. In this update, the y-axial rotation starting position has been changed to an option, allowing either the x- or z-axis to point towards the magnetometer. The code has been rewritten to use three simultaneous axes of magnetic data (three probes), now using two "rotations" of the device under test rather than the previous three rotations, thus reducing handling activities on the device under test. The present version of the software gathers data in one-degree increments, which permits much better accuracy of the fit ted data than the coarser data acquisition of the prior software. The data-conditioning module provides a clean data set for the analysis module. For multiple measurements at a given degree, the first measurement is used. For omitted measurements, the missing field is estimated by linear interpolation between the two nearest measurements. The analysis module was rewritten for the dual rotation, triaxial probe measurement process and now has better moment estimation accuracy, based on the finer one degree of data acquisition resolution. The magnetic moments thus computed are used as an input to summarize the total spacecraft field.

Shultz, Kimberly↗

Electromagnetic radiation from filamentary sources in the presence of axially magnetized cylindrical plasma scatterers

Electromagnetic radiation from filamentary electric-dipole and magnetic-current sources of infinite length in the presence of gyrotropic cylindrical scatterers in the surrounding free space is studied. The scatterers are assumed to be infinitely long, axially magnetized circular plasma columns parallel to the axis of the filamentary source. The field and the radiation pattern of each source are calculated in the case where the source frequency is equal to one of the surface plasmon resonance frequencies of the cylindrical scatterers. It is shown that the presence of even a single resonant magnetized plasma scatterer of small electrical radius or a few such scatterers significantly affects the total fields of the filamentary sources, so that their radiation patterns become essentially different from those in the absence of scatterers or the presence of isotropic scatterers of the same shape and size. It is concluded that the radiation characteristics of the considered sources can efficiently be controlled using their resonance interaction with the neighboring gyrotropic scatterers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear Magnetization Waves and Solitons in a Paramagnet with a Dipole Interaction

Based on a microscopic approach, we have derived equations for the local magnetization dynamics of a spin system coupled by a dipole–dipole interaction in a uniform magnetic field in the continuum approximation. Using the generalized method of multiple scales, we have found the corrections to the Larmor precession frequency of the magnetic moments due to the interparticle interaction, which lead to a broadening of spectral lines and the formation of satellites far from the Larmor frequency. We have derived nonlinear equations for the magnetization amplitude in higher expansion orders, which admit wave and soliton solutions. We have analyzed the influence of the nonsecular part of the dipole–dipole interaction on the stability of solitons and determined the conditions for their existence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Constraints on Covariant Dark-Matter–Nucleon Effective Field Theory Interactions from the First Science Run of the LUX-ZEPLIN Experiment

The LUX-ZEPLIN (LZ) experiment is a dual-phase xenon time project chamber operating in the Sanford Underground Research Facility in South Dakota, USA. We report on the results of a relativistic extension to the nonrelativistic effective field theory (NREFT) from a 5.5 t fiducial mass and 60 live days of exposure. We present constraints on couplings from covariant interactions arising from the coupling of vector, axial currents, and electric dipole moments of the nucleon to the magnetic and electric dipole moments of the weakly interacting massive particle which cannot be described by recasting previous results described by an NREFT. Using a profile-likelihood ratio analysis, in an energy region between 0 keV nr to 270 keV nr , we report 90% confidence level exclusion limits on the coupling strength of five interactions in both the isoscalar and isovector bases. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints On Covariant WIMP-Nucleon Effective Field Theory Interactions from the First Science Run of the LUX-ZEPLIN Experiment

The first science run of the LUX-ZEPLIN (LZ) experiment, a dual-phase xenon time project chamber operating in the Sanford Underground Research Facility in South Dakota, USA, has reported leading limits on spin-independent WIMP-nucleon interactions and interactions described from a non-relativistic effective field theory (NREFT). Using the same 5.5~t fiducial mass and 60 live days of exposure we report on the results of a relativistic extension to the NREFT. We present constraints on couplings from covariant interactions arising from the coupling of vector, axial currents, and electric dipole moments of the nucleon to the magnetic and electric dipole moments of the WIMP which cannot be described by recasting previous results described by an NREFT. Using a profile-likelihood ratio analysis, in an energy region between 0~keV_{nr} to 270~keV_{nr}, we report 90% confidence level exclusion limits on the coupling strength of five interactions in both the isoscalar and isovector bases. .

Source record↗

Assembly and Tests of Mechanical Models of the 15-T Nb 3 Sn Dipole Demonstrator

Within the US Magnet Development Program, Fermilab is developing a 15-T Nb 3 Sn dipole demonstrator. Prior to the construction of the real magnet model, short sections and the whole structure were instrumented with strain gauges and assembled to confirm the results of structural analysis, check tooling and to gain experience with the assembly of the real magnet components. We summarize the lessons learned from these mechanical models and compares the measured data with the finite element analysis.

43 PARTICLE ACCELERATORS↗

A Metallurgical Inspection Method to Assess the Damage in Performance-Limiting Nb 3 Sn Accelerator Magnet Coils

The design and production of Nb 3 Sn-based dipole and quadrupole magnets is critical for the realization of the High-Luminosity Large Hadron Collider (HL-LHC) at the European Organization for Nuclear Research (CERN). Nb 3 Sn superconducting coils are aimed at enhancing the bending and focusing strengths of accelerator magnets for HL-LHC and beyond. Due to the brittle nature of Nb 3 Sn, the coil fabrication steps are very challenging and require very careful QA/QC. Flaws in the Nb 3 Sn filaments may lead to quenches, and eventually, performance limitation below nominal during magnet testing. A novel inspection method, including advanced non-destructive and destructive techniques, was developed to explore the root-causes of quenches occurring in performance-limiting coils. The most relevant results obtained for MQXF coils through this innovative inspection method are presented. This approach allows for precise assessment of the physical events associated to the quenches experienced b y magnet coils, mainly occurring under the form of damaged strands with transversely broken sub-elements. Coil-slice preparation, micro-optical observations of transverse and longitudinal cross-sections, and a deep etching technique of copper will be illustrated in the present work, with a focus on the results achieved for a CERN coil from a non-conforming quadrupole magnet prototype, and two coils fabricated in the US, in the framework of the Accelerator Upgrade Project (AUP) collaboration, from two different non-conforming quadrupole magnets, respectively. The results obtained through the proposed inspection method will be illustrated.

43 PARTICLE ACCELERATORS↗

Response of a magnetic nanoparticle lattice to a magnetic field pulse near the stability boundary

The dynamic response of a system being near the stable equilibrium boundary to an external magnetic field pulse is studied for 2D lattices of magnetic nanoparticles with cubic crystallographic anisotropy. The conditions under which magnetic moment oscillations from individual dipoles propagate to the entire system are revealed. This effect results in the lattice response are significantly larger in the external pulse duration and with an amplitude rather weakly depending on initial conditions and external field parameters, the processes during which the pulse results in reorientation of only individual lattice dipoles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Micromagnetism in a planar system with a random magnetic anisotropy and two-dimensional magnetic correlations

The hysteresis loops and the micromagnetic structure of a ferromagnetic nanolayer with a randomly oriented local easy magnetization axis and two-dimensional magnetization correlations are studied using a micromagnetic simulation. The properties and the micromagnetic structure of the nanolayer are determined by the competition between the anisotropy and exchange energies and by the dipole–dipole interaction energy. The magnetic microstructure can be described as an ensemble of stochastic magnetic domains and topological magnetization defects. Dipole–dipole interaction suppresses the formation of topological magnetization defects. The topological defects in the magnetic microstructure can cause a sharper change in the coercive force with the crystallite size than that predicted by the random magnetic anisotropy model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Permanent and Inductive Magnetic Moments of Ganymede

Data acquired by the Galileo magnetometer on five passes by Ganymede have been used to characterize Ganymede's internal magnetic moments. Three of the five passes were useful for determination of the internal moments through quadrupole order. Models representing the internal field as the sum of dipole and quadrupole terms or as the sum of a permanent dipole field upon which is superimposed an induced magnetic dipole driven by the time varying component of the externally imposed magnetic field of Jupiter's magnetosphere give equally satisfactory fits to the data. The permanent dipole moment has an equatorial field magnitude 719 nT and is tilted by 176 degrees from the spin axis with the pole in the southern hemisphere rotated by 24 degrees from the Jupiter-facing meridian plane towards the trailing hemisphere. The data are consistent with an inductive response of a good electrical conductor of radius approximately 1 Ganymede radius. Although the data do not enable us to establish the presence of an inductive response beyond doubt, we favor the inductive response model because it gives a good fit to the data using only 4 parameters to describe the internal sources of fields, whereas the equally good dipole plus quadrupole fit requires 8 parameters. An inductive response is consistent with a buried conducting shell, probably liquid water with dissolved electrolytes, somewhere in the first few hundred km below Ganymede's surface. The depth at which the ocean is buried beneath the surface is somewhat uncertain, but our favored model suggests a depth of order 150 kilometers. As both temperature and pressure increase with depth and the melting temperature of pure ice decreases to a minimum at approximately 170 kilometer depth, it seems possible that near this location, a layer of water would be sandwiched between layers of ice.

Kivelson, M. G.↗

Design of an Emittance Compensation Superconducting Magnet Package for LCLS-II-HE's SRF Photo-Injector

An SRF photo-injector (low frequency, quarter-wave resonator plus emittance compensation magnet) is planned for LCLS-II-HE as it can provide a higher cathode gradient and better electron beam quality than other types of CW electron guns. The magnet package is located immediately downstream of the SRF cavity, and incorporates a solenoid doublet, bucking coils for reduction of the fringe field, normal/skew quadrupoles and horizontal/vertical dipoles. All the magnets are wound of NbTi wire and operate in liquid helium environment. The solenoid package is located inside the SRF gun cryomodule. Design considerations include space limitations, optimal emittance compensation, the magnetic field limits in the superconducting wire and quench protection. The solenoid coils must provide a peak excitation > 25 kgauss 2 ·cm, a fringe field < 20 gauss at the wall of the SRF cavity, an integrated dipole field < 90 gauss·cm and an integrated quadrupole field < 10 gauss. As a result, a genetic algorithm was used to optimize the solenoid design. Correction dipoles and quadrupoles were designed using coil dominated Walstrom style coils.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Triaxial-band structures, chirality, and magnetic rotation in La 133

The structure of 133 La has been investigated using the 116 Cd( 22 Ne,4pn) reaction and the Gammasphere array. Three new bands of quadrupole transitions and one band of dipole transitions are identified and the previously reported level scheme is revised and extended to higher spins. The observed structures are discussed using the cranked Nilsson-Strutinsky formalism, covariant density functional theory, and the particle-rotor model. Triaxial configurations are assigned to all observed bands. For the high-spin bands it is found that rotations around different axes can occur, depending on the configuration. The orientation of the angular momenta of the core and of the active particles is investigated, suggesting chiral rotation for two nearly degenerate dipole bands and magnetic rotation for one dipole band. As a result, it is shown that the h 11/2 neutron holes present in the configuration of the nearly degenerate dipole bands have significant angular momentum components not only along the long axis but also along the short axis, contributing to the balance of the angular momentum components along the short and long axes and thus giving rise to a chiral geometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Higher harmonics in planar Hall effect induced by cluster magnetic multipoles

Antiferromagnetic (AFM) materials are attracting tremendous attention due to their spintronic applications and associated novel topological phenomena. However, detecting and identifying the spin configurations in AFM materials are quite challenging due to the absence of net magnetization. Herein, we report the practicality of utilizing the planar Hall effect (PHE) to detect and distinguish “cluster magnetic multipoles” in AFM Nd 2 Ir 2 O 7 (NIO-227) fully strained films. By imposing compressive strain on the spin structure of NIO-227, we artificially induced cluster magnetic multipoles, namely dipoles and A 2 - and T 1 -octupoles. Importantly, under magnetic field rotation, each magnetic multipole exhibits distinctive harmonics of the PHE oscillation. Moreover, the planar Hall conductivity has a nonlinear magnetic field dependence, which can be attributed to the magnetic response of the cluster magnetic octupoles. Our work provides a strategy for identifying cluster magnetic multipoles in AFM systems and would promote octupole-based AFM spintronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design Study of a Superconducting Quadrupole Magnet System Sustainable Under Dark Current Heating in ILC Main Linac

The International Linear Collider (ILC) main linac comprises a series of 12 m-long cryomodules. The cryomodule contains eight 9-cell superconducting (SC) RF (SRF) cavities and an SC quadrupole magnet combined with dipole correctors to focus and steer electron and positron beams. The magnets are installed between the SRF cavity string and at the longitudinal center of a common cryomodule/cryostat. These magnets are conductively cooled by pure aluminum channels thermally connected to a 2 K two-phase helium pipe for cooling the SRF cavities. A recent study shows that field-emitted electrons, so-called “dark current” initiated in the SRF cavities, are transmitted through the SRF cavity string and reach the SC magnet. The energy is inevitably absorbed in the SC coil due to the magnetic field, resulting in risks of a quench caused by the coil heating. We are investigating alternate magnet designs by using Nb $_{3}$ Sn or $\text{MgB}_{2}$ SC and by adding the dark current absorber surrounding the beam-pipe to realize sustainable magnet operation under the dark current heating. We report the design study of the magnet system and interfaces to the cryomodule accommodating it with the SRF cavities.

43 PARTICLE ACCELERATORS↗

Single-Crystal Diffuse Neutron Scattering Study of the Dipole-Octupole Quantum Spin-Ice Candidate Ce 2⁢ Zr 2 ⁢O 7 : No Apparent Octupolar Correlations Above 𝑇 = 0.05 K

The insulating magnetic pyrochlore Ce 2 ⁢Zr 2 ⁢O 7 has gained attention as a quantum spin-ice candidate with dipole-octupole character that arises from the crystal-electric-field ground-state doublet for the Ce 3+ Kramers ion. This dipole-octupole character permits both spin-ice phases based on magnetic dipoles and those based on more-exotic octupoles. This work reports low-temperature neutron diffraction measurements on single-crystal Ce 2 ⁢Zr 2⁢ O 7 with 𝑄 coverage both at low 𝑄, where the magnetic form factor for dipoles is near maximal, and at high 𝑄, covering the region where the magnetic form factor for Ce 3+ octupoles is near maximal. This study was motivated by recent powder neutron diffraction studies of other Ce-based dipole-octupole pyrochlores, Ce 2 ⁢Sn 2 ⁢O 7 and Ce 2 ⁢Hf 2 ⁢O 7 , which each showed temperature-dependent diffuse diffraction at high 𝑄, interpreted as arising from octupolar correlations. Our measurements use an optimized single-crystal diffuse scattering instrument that allows us to screen against strong Bragg scattering from Ce 2 ⁢Zr 2 ⁢O 7 . The temperature-difference neutron diffraction reveals a low-𝑄 peak consistent with dipolar spin-ice correlations reported in previous work, and an alternation between positive and negative net intensity at higher 𝑄. These features are consistent with our numerical-linked-cluster calculations using pseudospin interaction parameters previously reported for Ce 2 ⁢Zr 2⁢ O 7 , Ce 2 ⁢Sn 2 ⁢O 7 , and Ce 2 ⁢Hf 2 ⁢O 7 . Importantly, neither the measured data nor any of the NLC calculations show evidence for increased scattering at high 𝑄 resulting from octupolar correlations. We conclude that at the lowest attainable temperature for our measurements (𝑇 = 0.05 K), scattering from octupolar correlations in Ce 2 ⁢Zr 2 ⁢O 7 is not present in the neutron diffraction signal on the level of our observation threshold of around 0.1% of the low-𝑄 dipole scattering. We compare these results to those obtained earlier on powder Ce 2 ⁢Sn 2 ⁢O 7 and Ce 2⁢ Hf 2⁢ O 7 , and to low-energy inelastic neutron scattering from single-crystal Ce 2 ⁢Zr 2 ⁢O 7 .

36 MATERIALS SCIENCE↗