Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC GUIDE FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Hamiltonian Formulations and Momentum Conservation Laws of Reduced Plasma Models (Final Report for Research supported by US DoE grant DE-SC0006721)

A final report is presented on research carried out by Alain J. Brizard (Principal Investigator) with funding provided by the U.S. DoE grant No. DE-SC0006721 during the period of 08/01/2011 to 07/31/2014.The overall goal of this project is to investigate the Hamiltonian structure and momentum conservation laws of several reduced plasma models used for the analytical and numerical studies of long-time-scale turbulent transport processes in strongly magnetized plasmas. The reduced plasma models considered in the proposed activity (associated with the asymptotic elimination of the fast gyromotion time scale) are the guiding-center and gyrokinetic Vlasov-Maxwell equations and the nonlinear gyrofluid equations. The proposed research activity is divided into three parts: Part I - We propose to explore the Vlasov-Maxwell functional bracket for the guiding-center Vlasov-Maxwell equations and extend its applications to the gyrokinetic Vlasov-Maxwell equations. Part II - We propose to develop a new Hamiltonian Lie-transform perturbation method for fields (i.e., in the infinite-dimensional space of functions) in terms of the functional brackets for reduced plasma models developed in Part I of this proposal. Part III - We propose to investigate the exact momentum and angular-momentum conservation laws for several reduced plasma models. In particular, the reduced angular-momentum conservation laws derived from our reduced plasma models contain the effects of intrinsic (spin) angular momentum associated with the process of dynamical reduction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Exploration of multi-fold symmetry element-loaded superconducting radio frequency structure for reliable acceleration of low- & medium-beta ion species

Reliable acceleration of low- to medium-beta proton or heavy ion species is needed for future high-current superconducting radio frequency (SRF) accelerators. Due to the high-Q nature of an SRF resonator, it is sensitive to many factors such as electron loading (from either the accelerated beam or from parasitic field emitted electrons), mechanical vibration, and liquid helium bath pressure fluctuation etc. To increase the stability against those factors, a mechanically strong and stable RF structure is desirable. Guided by this consideration, multi-fold symmetry element-loaded SRF structures (MFSEL), cylindrical tanks with multiple (n>=3) rod-shaped radial elements, are being explored. The top goal of its optimization is to improve mechanical stability. A natural consequence of this structure is a lowered ratio of the peak surface electromagnetic field to the acceleration gradient as compared to the traditional spoke cavity. A disadvantage of this new structure is an increased size for a fixed resonant frequency and optimal beta. This paper describes the optimization of the electro-magnetic (EM) design and preliminary mechanical analysis for such structures.

43 PARTICLE ACCELERATORS↗

TH-A-BRF-05: MRI of Individual Lymph Nodes to Guide Regional Breast Radiotherapy

Purpose: In regional radiotherapy (RT) for breast-cancer patients, direct visualization of individual lymph nodes (LNs) may reduce target volumes and Result in lower toxicity (i.e. reduced radiation pneumonitis, arm edema, arm morbidity), relative to standard CT-based delineations. To this end, newly designed magnetic resonance imaging (MRI) sequences were optimized and assessed qualitatively and quantitatively. Methods: In ten healthy female volunteers, a scanning protocol was developed and optimized. Coronal images were acquired in supine RT position positioned on a wedge board on a 1.5 T Ingenia (Philips) wide-bore MRI. In four volunteers the optimized MRI protocol was applied, including a 3-dimensional (3D) T1-weighted (T1w) fast-field-echo (FFE). T2w sequences, including 3D FFE, 3D and 2D fast spin echo (FSE), and diffusion-weighted single-shot echo-planar imaging (DWI) were also performed. Several fatsuppression techniques were used. Qualitative evaluation parameters included LN contrast, motion susceptibility, visibility of anatomical structures, and fat suppression. The number of visible axillary and supraclavicular LNs was also determined. Results: T1 FFE, insensitive to motion, lacked contrast of LNs, which often blended in with soft tissue and blood. T2 FFE showed high contrast, but some LNs were obscured due to motion. Both 2D and 3D FSE were motion-insensitive having high contrast, although some blood remained visible. 2D FSE showed more anatomical details, while in 3D FSE, some blurring occurred. DWI showed high LN contrast, but suffered from geometric distortions and low resolution. Fat suppression by mDixon was the most reliable in regions with magnetic-field inhomogeneities. The FSE sequences showed the highest sensitivity for LN detection. Conclusion: MRI of regional LNs was achieved in volunteers. The FSE techniques were robust and the most sensitive. Our optimized MRI sequences can facilitate direct delineation of individual LNs. This can Result in smaller target volumes and reduced toxicity in regional RT compared to standard CT planning.

60 APPLIED LIFE SCIENCES↗

Development and Application of Predictive Tools for MHD Stability Limits in Tokamaks

This is a project to develop and apply analytic and computational tools to answer physics questions relevant to the onset of non-ideal magnetohydrodynamic (MHD) instabilities in toroidal magnetic confinement plasmas. The focused goal of the research is to develop predictive tools for these instabilities, including an inner layer solution algorithm, a resistive wall with control coils, and energetic particle effects. The production phase compares studies of instabilities in such systems using analytic techniques, PEST- III and NIMROD. Two important physics puzzles are targeted as guiding thrusts for the analyses. The first is to form an accurate description of the physics determining whether the resistive wall mode or a tearing mode will appear first as β is increased at low rotation and low error fields in DIII-D. The second is to understand the physical mechanism behind recent NIMROD results indicating strong damping and stabilization from energetic particle effects on linear resistive modes. The work seeks to develop a highly relevant predictive tool for ITER, advance the theoretical description of this physics in general, and analyze these instabilities in experiments such as ASDEX Upgrade, DIII-D, JET, JT-60U and NTSX. The awardee on this grant is the University of Tulsa. The research efforts are supervised principally by Dr. Brennan. Support is included for two graduate students, and a strong collaboration with Dr. John M. Finn of LANL. The work includes several ongoing collaborations with General Atomics, PPPL, and the NIMROD team, among others.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

40-meter-long REBCO tapes with critical current over 4,000 A/12 mm at 4.2 K and 13 T by advanced MOCVD

REBa 2 Cu 3 O 7–δ (REBCO, RE = rare earth) tapes doped with 5% and 15% Zr have been scaled up to lengths more than 40 m in a pilot-scale advanced metal organic chemical vapor deposition (A-MOCVD) tool. The precursor compositions used for the long tapes were guided by a study of the influence of (Ba + dopant)/Cu content on the critical current density (J c ) of 5 and 15 mol.% Hf- and Zr-added tapes at 4.2 K and 13 T. The 40-m-long tapes exhibited a critical current (I c ) over 4,000 A/12 mm at 4.2 K and 13 T as well as over 1,400 A/12 mm at 20 K and 20 T. The critical current densities of a 40-m-long tape doped with 5% Zr at 4.2 K measured at the National High Magnetic Field Laboratory (NHMFL) were > 10 MAcm –2 and >5 MAcm –2 at 14 T and 30 T, respectively, which are over three times those of commercial REBCO tapes. The infield J c of 5% Zr-added 40-m-long tapes was similar to those of previously-reported high-performance short samples made with 15% Zr or Hf. These results demonstrate the excellent potential of A-MOCVD for manufacturing high I c REBCO tapes for use in ultrahigh-field magnet applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The inference of vector magnetic fields from polarization measurements with limited spectral resolution

A method is presented for recovery of the vector magnetic field and thermodynamic parameters from polarization measurement of photospheric line profiles measured with filtergraphs. The method includes magneto-optic effects and may be utilized on data sampled at arbitrary wavelengths within the line profile. The accuracy of this method is explored through inversion of synthetic Stokes profiles subjected to varying levels of random noise, instrumental wave-length resolution, and line profile sampling. The level of error introduced by the systematic effect of profile sampling over a finite fraction of the 5 minute oscillation cycle is also investigated. The results presented here are intended to guide instrumental design and observational procedure.

Lites, B. W.↗

Distribution in magnetotail of O(+) ions from cusp/cleft ionosphere - A possible substorm trigger

The transport of O(+) ions from the cusp/cleft ionosphere to the magnetotail during highly disturbed times was determined by computing the guiding-center trajectories of the ions to a distance of 6 R(E) from the ionosphere and the full-motion trajectories at later times. Case histories were tallied in six planes perpendicular to the X(GSM) axis, three planes perpendicular to the Y(GSM) axis, and in the center plane of the tail. At various times relative to the enhancement of the convection electric field, the following ion properties were constructed from the case histories: number density, mean energy, energy and pitch angle distributions of the flux, and ion pressure components parallel and perpendicular to the magnetic field. It was found that, after about 1.7 hours, the ion flux in the near-earth magnetotail increased dramatically and the spectrum hardened, much as observed during periods just preceding substorms. This increase is attributed to (1) the increase in the O(+) outflux from the ionosphere, (2) the increased energization of the ions by the convection electric field, and (3) ion trapping, which generally occurs because the ion magnetic moments generally increase after the ions first cross the geomagnetotail center plane.

Cladis, J. B.↗

Optical design and synthetic analysis of the electron cyclotron emission imaging diagnostic of HL-2M tokamak

The electron cyclotron emission imaging (ECEI) diagnostic is a powerful tool to study the MHD and turbulent transport in magnetically confined fusion plasmas. In this work, the optical system including the local oscillator (LO) coupling and radio frequency (RF) receiving optics, has been designed and analyzed for the HL-2M ECEI diagnostic. The LO optics can illuminate the antenna array and drive the mixer diode to work efficiently, with more than 36% of the beam intensity for the channels which probe the plasma edge relative to those of channels which probe the plasma core. The RF optics aims at guiding the plasma emission signal to the antenna array. To meet different physical requirements, three types of field of view have been achieved for the plasma imaging, with zoom factors of around 1, 1.5 and 2, respectively. The focal surfaces are almost flat, with a maximum off-mapping (defined as the radial distance between the beam waists of the lower-/uppermost antennas and electron cyclotron emission layer) less than 2.5 cm, which can match the electron cyclotron emission layer quite well and suppress the image distortion in the plasma edge region. Furthermore, the impact of possible vibrations and installation error on the focal plane has been evaluated. In addition, the predefined MHD and turbulence perturbations are well reproduced by combining the optical simulation results and synthetic ECEI modeling, which further verifies the good performance of the RF optics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetization curves of sintered heavy tungsten alloys for applications in MRI-guided radiotherapy

Purpose: Due to the current interest in MRI-guided radiotherapy, the magnetic properties of the materials commonly used in radiotherapy are becoming increasingly important. In this paper, measurement results for the magnetization (BH) curves of a range of sintered heavy tungsten alloys used in radiation shielding and collimation are presented. Methods: Sintered heavy tungsten alloys typically contain >90 % tungsten and <10 % of a combination of iron, nickel, and copper binders. Samples of eight different grades of sintered heavy tungsten alloys with varying binder content were investigated. Using a superconducting quantum interference detector magnetometer, the induced magnetic momentm was measured for each sample as a function of applied external field H{sub 0} and the BH curve derived. Results: The iron content of the alloys was found to play a dominant role, directly influencing the magnetizationM and thus the nonlinearity of the BH curve. Generally, the saturation magnetization increased with increasing iron content of the alloy. Furthermore, no measurable magnetization was found for all alloys without iron content, despite containing up to 6% of nickel. For two samples from different manufacturers but with identical quoted nominal elemental composition (95% W, 3.5% Ni, 1.5% Fe), a relative difference in the magnetization of 11%–16% was measured. Conclusions: The measured curves show that the magnetic properties of sintered heavy tungsten alloys strongly depend on the iron content, whereas the addition of nickel in the absence of iron led to no measurable effect. Since a difference in the BH curves for two samples with identical quoted nominal composition from different manufacturers was observed, measuring of the BH curve for each individual batch of heavy tungsten alloys is advisable whenever accurate knowledge of the magnetic properties is crucial. The obtained BH curves can be used in FEM simulations to predict the magnetic impact of sintered heavy tungsten alloys.

36 MATERIALS SCIENCE↗

Beyond the Surface: Non-Invasive Low-Field NMR Analysis of Microbially-Induced Calcium Carbonate Precipitation in Shale Fractures

Microbially-induced calcium carbonate precipitation (MICP) is a biological process in which microbially-produced urease enzymes convert urea and calcium into solid calcium carbonate (CaCO 3 ) deposits. MICP has been demonstrated to reduce permeability in shale fractures under elevated pressures, raising the possibility of applying this technology to enhance shale reservoir storage safety. For this and other applications to become a reality, non-invasive tools are needed to determine how effectively MICP seals shale fractures at subsurface temperatures. In this study, two different MICP strategies were tested on 2.54 cm diameter and 5.08 cm long shale cores with a single fracture at 60 °C. Flow-through, pulsed-flow MICP-treatment was repeatedly applied to Marcellus shale fractures with and without sand (“proppant”) until reaching approximately four orders of magnitude reduction in apparent permeability, while a single application of polymer-based “immersion” MICP-treatment was applied to an Eagle Ford shale fracture with proppant. Low-field nuclear magnetic resonance (LF-NMR) and X-Ray computed microtomography (micro-CT) techniques were used to assess the degree of biomineralization. With the flow-through approach, these tools revealed that while CaCO 3 precipitation occurred throughout the fracture, there was preferential precipitation around proppant. Without proppant, the same approach led to premature sealing at the inlet side of the core. In contrast, immersion MICP-treatment sealed off the fracture edges and showed less mineral precipitation overall. This study highlights the use of LF-NMR relaxometry in characterizing fracture sealing and can help guide NMR logging tools in subsurface remediation efforts.

MICP↗

Development of a coupled experimental–computational approach for engineering optimization of spout-fluidized bed particle coating systems

The design of spout-fluidized bed (SFB) coating systems for nuclear particle fuels typically relies on trial-and-error processes, comprising iterative and time-consuming coating deposition experiments and post-deposition characterization. At an engineering scale, this approach to guided SFB system design is inefficient, highlighting the need for streamlined experimental methodologies which can correlate fluidization conditions to downstream coating outcomes. In this study, we combine time-resolved particle image velocimetry (PIV) with CFD–DEM simulations to benchmark hydrodynamic behavior in a 3D spout-fluidized bed. By exploiting easily accessible optical measurements of particle motion at the bed wall and within the spouting region, we obtain quantitative velocity fields that can be directly compared with model predictions of the occluded bed region, without resorting to complex imaging and characterization techniques such as X-ray or magnetic resonance tomography. Experimental benchmarking reveals strong agreement between CFD–DEM and PIV in the spout and annulus regions, while discrepancies near the wall highlight areas for future model development. Here, the proposed integrated experimental–numerical framework will enable a direct connection between measured variables and numerically predicted fluidization performance of dense, surrogate nuclear particle fuel feedstock such that experimental SFB component design can be rapidly evaluated, informing design decisions for nozzle geometry and operating conditions. Future work will extend this framework by correlating quantified fluidization metrics across nozzle geometries and operating conditions with the resulting coating morphology, microstructure, and uniformity. Establishing these correlations will enable predictive links between hydrodynamic performance and coating quality, providing a rational, scalable basis for optimizing SFB design prior to coating deposition.

CFD/DEM↗

TH-C-12A-01: Develop a Patient-Specific QA Program for Radiation Therapy with On-Board MRI

Purpose: This work describes development of the first patient-specific quality assurance (QA) program for magnetic resonance imaging guided radiation therapy (MR-IGRT). Methods: The program consisted of following components: 1) multipoint ionization chamber (IC) measurement using a 15 cm3 cubic phantom, 2) 2D stacked radiographic film dosimetry using a 30×30×20 cm3 phantom with multiple inserted ICs, 3) 3D ArcCHECK measurement with a centrally inserted IC, 4) machine delivery file verification, 5) 3D Monte-Carlo dose re-calculation with machine delivery file and phantom CT, 6) 2-head mode delivery validation in case of a malfunctioning head, and 7) independent beam-on time calculation for non-IMRT fields. Both ADCL calibrated ICs and ArcCHECK were MRI compatible. Experimental data were analyzed for the first 10 patients treated at our institution. Results: The customized phantoms allowed measuring multiple points with ICs in one delivery. Absolute IC measurements were all within 3% in all phantom geometry/shape/material combinations. Despite known uncertainty associated with film dosimetry, passing rates greater than 90% were achieved in both absolute and composite modes using TG-129 criteria. Due to the simultaneous irradiation by three radiation sources, ArcCHECK was used as a 3D relative dosimeter with angular and energy dependences uncorrected. 95–100% passing rates were obtained and the centrally inserted IC measurement assured that the overall dose normalization was within 3%. Machine delivery file verification and MC recalculated dose to the phantom results showed 98–100% passing rates, providing opportunity of moving from gamma passing rates to patient DVHbased QA metrics. Same results were obtained for the 2-head delivery mode. Manual beam-on time calculation for non-IMRT fields showed better than 5% agreement. Conclusion: We have successfully developed the first MRIGRT patient specific QA program by adopting experimental and computational dosimetry methods that were developed in the past decade for other radiation therapy modalities.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRA-01: A Novel Doubly-Focused Multileaf Collimator Design for MR-Guided Radiation Therapy

Purpose: To describe the physical and dosimetric properties of a novel double-stack multileaf collimator (MLC). Methods: One of the compromises made in the MLC design has been to employ linear-motion singly-divergent shapes. Because the MLC leading edge moves linearly, it is rounded to provide a consistent, albeit compromised penumbra. The MLC employed in the new linac-based MR-IGRT unit is designed to be doubly focused in that each leaf moves in an arc centered at the source, and the sides of the leaves are machined such that they lie parallel to a line between the leaf edge and the source. The curvature of the MLC keeps motors and encoders in lower magnetic field. However, high spatial-resolution leaves are difficult to manufacture to sufficiently tight tolerances and difficult to move due to restricted space on the gantry. Wider leaves alleviate this problem with less moving parts but the coarse resolution disallows treating very small lesions. This compromise has been overcome by splitting the MLC leaf bank into two sets, stacked one upon the other and offset half of a leaf width. The dosimetry has been simulated using Monte-Carlo and a 6 MV linac in a 0.35 T magnetic field. Results: The combined MLC leaf set has a spatial resolution of effectively half of the leaf width, 4mm here. The dosimetry resolution and conformality are consistent with 4mm wide MLC assisted by inverse fluence modulation. Also, because each leaf junction is backed up by the stacked leaf that lies over the junction, the problem of tongue-and-groove dosimetry has been greatly reduced. The novel MLC design allows the use of more powerful leaf motors than would be otherwise possible if a single MLC bank is employed. Conclusions: The stacked MLC will provide highly conformal dose distributions suitable for stereotactic radiation therapy of small lesions. The research was funded by ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

Handling Radioactive Waste from the Proton Accelerator Facility at the Paul Scherrer Institut (PSI) - Always Surprising? - 13320

The Paul Scherrer Institut (PSI) is the largest national research centre in Switzerland. Its multidisciplinary research is dedicated to a wide field in natural science and technology as well as particle physics. In this context, PSI is operating, amongst others, a large proton accelerator facility since more than 30 years. In two cyclotrons, protons are accelerated to high speeds and then guided along roughly 100 m of beam line to three different target stations to produce secondary particles like mesons and neutrons for experiments and a separately beam line for UCN. The protons induce spallation processes in the target materials, and also at other beam loss points along the way, with emission of protons, neutrons, hydrogen, tritium, helium, heavier fragments and fission processes. In particular the produced neutrons, due to their large penetration depth, will then interact also with the surrounding materials. These interactions of radiation with matter lead to activation and partly to contamination of machine components and the surrounding infrastructures. Maintenance, operation and decommissioning of installations generate inevitably substantial amounts of radioactive operational and dismantling waste like targets, magnets, collimators, shielding (concrete, steel) and of course secondary waste. To achieve an optimal waste management strategy for interim storage or final disposal, radioactive waste has to be characterized, sorted and treated. This strategy is based on radiation protection demands, raw waste properties (size, material, etc.), and requirements to reduce the volume of waste, mainly for legal and economical reasons. In addition, the radiological limitations for transportation of the waste packages to a future disposal site have to be taken into account, as well as special regulatory demands. The characterization is a task of the waste producer. The conditioning processes and quality checks for radioactive waste packages are part of an accredited waste management process of PSI, especially of the Section Dismantling and Waste Management. Strictly proven and accepted methods needed to be developed and enhanced for safe treatment, transport, conditioning and storage. But in the field of waste from research activities, individual and new solutions have to be found in an increasingly growing administrative environment. Furthermore, a wide variety of components, with a really large inventory of radioactive nuclides, has to be handled. And there are always surprising challenges concerning the unusual materials or the nuclide inventory. In case of the operational and dismantling radioactive accelerator waste, the existing conditioning methods are in the process of a continuous enhancement - technically and administratively. The existing authorized specifications of conditioning processes have to be extended to optimize and fully describe the treatment of the inevitably occurring radioactive waste from the accelerator facility. Additional challenges are the changes with time concerning the legal and regulatory requirements - or do we have to consider it as business as usual? This paper gives an overview of the current practices in radioactive waste management and decommissioning of the existing operational accelerator waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Precision Measurements of Electron-Proton Elastic Scattering Cross Sections at Large Q2

The electromagnetic form factors are fundamental quantities characterizing the internal structure of the nucleon. Their measurements have provided significant insight into the spatial distribution and interaction of quarks inside the proton. The knowledge of high Q2 form factors proves essential in understanding the properties of quantum chromodynamics in the transition region from non-perturbative to perturbative behavior. It also provides important links to generalized parton distributions, which describe the three-dimensional structure of hadrons at the parton level. In view of the significant theoretical research activities in this field, high quality experimental data are crucial for providing stringent tests and benchmarks to guide and test different models. The form factors can be accessed in experiments by measuring elastic scattering of electrons off a hydrogen target. Experiment E12-07-108, which took place at the Thomas Jefferson National Accelerator Facility, conducted precise measurements of the unpolarized e-p elastic scattering cross section over a Q2 range of 0.6-16.5 GeV2 . This thesis presents the results for 7 kinematic settings with total uncertainties that are 1.5 times smaller than those of the existing data at large Q2 . The proton magnetic form factors were extracted using a parameterization of the form factor ratio obtained from recent polarized e-p scattering experiments. Comparisons to existing global and phenomenological fits are presented.

Ou, Longwu↗

Neutron resonance spin-echo upgrade at the three-axis spectrometer FLEXX

We describe the upgrade of the neutron resonance spin-echo setup at the cold neutron triple-axis spectrometer FLEXX at the BER II neutron source at the Helmholtz-Zentrum Berlin. The parameters of redesigned key components are discussed, including the radio frequency (RF) spin-flip coils, the magnetic shield, and the zero field coupling coils. The RF-flippers with larger beam windows allow for an improved neutron flux transfer from the source to the sample and further to the analyzer. The larger beam cross sections permit higher coil inclination angles and enable measurements on dispersive excitations with a larger slope of the dispersion. Due to the compact design of the spin-echo units in combination with the increased coil tilt angles, the accessible momentum-range in the Larmor diffraction mode is substantially enlarged. In combination with the redesigned components of the FLEXX spectrometer, including the guide, the S-bender polarizer, the double focusing monochromator, and a Heusler crystal analyzer, the count rate increased by a factor of 15.5, and the neutron beam polarization is enhanced. The improved performance extends the range of feasible experiments, both for inelastic scattering on excitation lifetimes in single crystals, and for high-resolution Larmor diffraction. The experimental characterization of the instrument components demonstrates the reliable performance of the new neutron resonance spin-echo option, now available for the scientific community at FLEXX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗