Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONOCHROMATIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Optical atmospheric scattering and absorption limitations on offset pointing from Earth Observatory Satellite /EOS/ sensors

The Braslau-Dave atmospheric model which calculates the upward monochromatic light fluxes leaving the top of the atmosphere as a function of viewing angle, sun angle, and ground reflectance was employed to study the effect of atmospheric scattering and attenuation on universal apparent contrast for two EOS remote sensors operated at very large offset or pointing angles: the Thematic Mapper (TM) and the High Resolution Pointable Imager (HRPI). The TM offset off nadir could be plus or minus 20 degrees with an 11 degree scan angle and the HRPI pointing angle off nadir could be plus or minus 45 degrees with a 3 degree scan angle. The reduction of universal apparent contrast of EOS imagery is studied as a function of sun elevation angle, atmospheric aerosol loading, radiation wavelength and sensor look angles.

Egan, W. G.↗

McStas Analysis of Monoenergetic Thermal Neutron Beam Generation for Total Cross Section Measurements

The thermal neutron scattering law (TSL) of a given material represents data that is essential for assessing the criticality safety of a neutronic system in which this material is utilized. Traditionally, the TSL is developed through elaborate calculations that combine input and models based on condensed matter physics and scattering theory. Nonetheless, measurements of key parameters (e.g., the total cross section at low energies) can help in benchmarking and validating TSL libraries such as those used in the ENDF/B database. In this work, the setup of experiments, at the PULSTAR reactor of North Carolina State University (NCSU), for creating monoenergetic thermal neutron beams in support of total scattering cross section measurements in the thermal energy range is explored using McStas simulations and experimental verification. A McStas model has been established of the NPD facility at the NCSU PULSTAR reactor to explore the production of monoenergetic thermal neutron beams in support of various applications including total cross section measurements. The McStas results clearly demonstrate the viability of six monochromatic thermal neutron beams with substantial intensities that allow future applications at the NPD facility. The experimental results reasonably support the computational model predictions. Based on these results, transmission thermal neutron experiments can be conducted for data validation studies. Furthermore, the model also allows the evaluation of design changes to expand the portfolio of available monoenergetic thermal neutron beams. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Diffraction based Hanbury Brown and Twiss interferometry at a hard x-ray free-electron laser

X-ray free-electron lasers (XFELs) provide extremely bright and highly spatially coherent x-ray radiation with femtosecond pulse duration. Currently, they are widely used in biology and material science. Knowledge of the XFEL statistical properties during an experiment may be vitally important for the accurate interpretation of the results. Here, for the first time, we demonstrate Hanbury Brown and Twiss (HBT) interferometry performed in diffraction mode at an XFEL source. It allowed us to determine the XFEL statistical properties directly from the Bragg peaks originating from colloidal crystals. This approach is different from the traditional one when HBT interferometry is performed in the direct beam without a sample. Our analysis has demonstrated nearly full (80%) global spatial coherence of the XFEL pulses and an average pulse duration on the order of ten femtoseconds for the monochromatized beam, which is significantly shorter than expected from the electron bunch measurements.

47 OTHER INSTRUMENTATION↗

Detecting Dark Matter annihilation lines with Fermi

Dark matter constitutes one of the most intriguing but so far unresolved issues in physics today. In many extensions of the Standard Model the existence of a stable Weakly Interacting Massive Particle (WIMP) is predicted. The WIMP is an excellent dark matter particle candidate and one of the most interesting scenarios include an annihilation of two WIMPs into two gamma-rays. If the WIMPs are assumed to be non-relativistic, the resulting photons will both have an energy equal to the mass of the WIMP and manifest themselves as a monochromatic spectral line in the energy spectrum. This type of signal would represent a 'smoking gun' for dark matter, since no other known astrophysical process should be able to produce it. In these proceedings we give an overview of the different approaches to a search for dark matter lines that the Fermi-LAT collaboration is pursuing and the various challenges involved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Dawn of Nuclear Photonics with Laser-based Gamma-rays

A renaissance in nuclear physics is occurring around the world because of a new kind of incredibly bright, gamma-ray light source that can be created with short pulse lasers and energetic electron beams. These highly Mono-Energetic Gamma-ray (MEGa-ray) sources produce narrow, laser-like beams of incoherent, tunable gamma-rays and are enabling access and manipulation of the nucleus of the atom with photons or so called 'Nuclear Photonics'. Just as in the early days of the laser when photon manipulation of the valence electron structure of the atom became possible and enabling to new applications and science, nuclear photonics with laser-based gamma-ray sources promises both to open up wide areas of practical isotope-related, materials applications and to enable new discovery-class nuclear science. In the United States, the development of high brightness and high flux MEGa-ray sources is being actively pursued at the Lawrence Livermore National Laboratory in Livermore (LLNL), California near San Francisco. The LLNL work aims to create by 2013 a machine that will advance the state of the art with respect to source the peak brightness by 6 orders of magnitude. This machine will create beams of 1 to 2.3 MeV photons with color purity matching that of common lasers. In Europe a similar but higher photon energy gamma source has been included as part of the core capability that will be established at the Extreme Light Infrastructure Nuclear Physics (ELI-NP) facility in Magurele, Romania outside of Bucharest. This machine is expected to have an end point gamma energy in the range of 13 MeV. The machine will be co-located with two world-class, 10 Petawatt laser systems thus allowing combined intense-laser and gamma-ray interaction experiments. Such capability will be unique in the world. In this talk, Dr. Chris Barty from LLNL will review the state of the art with respect to MEGa-ray source design, construction and experiments and will describe both the ongoing projects around the world as well some of the exciting applications that these machines will enable. The optimized interaction of short-duration, pulsed lasers with relativistic electron beams (inverse laser-Compton scattering) is the key to unrivaled MeV-scale photon source monochromaticity, pulse brightness and flux. In the MeV spectral range, such Mono-Energetic Gamma-ray (MEGa-ray) sources can have many orders of magnitude higher peak brilliance than even the world's largest synchrotrons. They can efficiently perturb and excite the isotope-specific resonant structure of the nucleus in a manner similar to resonant laser excitation of the valence electron structure of the atom.

42 ENGINEERING↗

Investigation on the upconversion luminescence in Ho3+/Yb3+ co-doped Ba3Sc4O9 phosphor

Highlights: • The optical properties of novel Ba{sub 3}Y{sub 4}O{sub 9}:Ho{sup 3+}/Yb{sup 3+} phosphor were investigated. • The luminescence color could be tuned from green to yellow-green light. • The energy transfer mechanisms of UC luminescence were investigated in detail. • The phosphor can be a good candidate for green UC material in display fields and fluorescent labeling. - Abstract: A series of Ba{sub 3}Sc{sub 4}O{sub 9}:Ho{sup 3+}/Yb{sup 3+} phosphors were synthesized by a high-temperature solid-state reaction method. The phase purity and upconversion luminescence were characterized by X-ray diffraction and photoluminescence spectroscopy. The sintering temperature and doping concentrations were optimized to obtain the strongest emission intensity. Under 980 nm laser diode excitation, the green (545 nm, {sup 5}F{sub 4}/{sup 5}S{sub 2} → {sup 5}I{sub 8}) and red (665 nm, {sup 5}F{sub 5} → {sup 5}I{sub 8}) emissions were observed. The cross-relaxation and back-energy-transfer processes play an important role to adjust the emission intensity ratio of Green/Red at different dopant concentrations. Based on the energy level diagrams, the energy transfer mechanisms are investigated in detail according to the analysis of pump power dependence and luminescence decay curves. The upconversion luminescence properties of the phosphor were evaluated and the results show good color monochromaticity and relatively high upconversion luminescence intensity. The Ba{sub 3}Sc{sub 4}O{sub 9}:Ho{sup 3+}/Yb{sup 3+} can be a good candidate for green upconversion material in display fields and fluorescent labeling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imprinting a Focused X-Ray Laser Beam to Measure Its Full Spatial Characteristics

The new generation of x-ray free-electron lasers opens up unique avenues for exploring matter under exotic and extreme conditions. Extensive spatial characterization of focused, typically (sub)micron-sized, laser beams is indispensable but, nevertheless, difficult to be accomplished due to excessive radiation intensities. Methods exist allowing indirect or semidirect focus characterization from a safe distance far from the focal point. Here, in this study, we present a direct method of in-focus numerical phase recovery exploiting multishot desorption imprints in poly(methyl methacrylate). Shapes of the imprints serve as input data for the newly developed code PhaRe (phase recovery), inspired by the iterative Gerchberg-Saxton algorithm. A procedure of dynamic input-output mixing guarantees that the algorithm always converges to a self-consistent paraxial Helmholtz equation solution, which is thereafter optimized for transverse spatial coherence. Very good agreement with single-shot ablation imprints in lead tungstate (PbWO 4 ) is found. The experiment is carried out at the Linac Coherent Light Source with a focused beam monochromatized at 800 eV. The results of the coherence optimization indicate that the act of monochromatization may have an effect on otherwise very good transverse coherence of free-electron laser beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extending Fermi -LAT and H.E.S.S. limits on gamma-ray lines from dark matter annihilation

Gamma-ray lines from dark matter annihilation (χχ → γX, where X = γ, h, Z) are always accompanied, at lower energies, by a continuum gamma-ray spectrum stemming both from radiative corrections (X = γ) and from the decay debris of the second particle possibly present in the final state (X = h, Z). This model-independent gamma-ray emission can be exploited to derive novel limits on gamma-ray lines that do not rely on the line feature. Although such limits are not expected to be as stringent as those based on the line feature, they can be used to probe the existence of gamma-ray lines for dark matter masses beyond the largest energies accessible to current telescopes. In this report we use continuous gamma-ray searches from Fermi-LAT observations of Milky Way dwarf spheroidal galaxies and from H.E.S.S. observations of the Galactic halo to extend the limits on the annihilation cross-sections into monochromatic photons to dark matter masses well beyond 500 GeV (Fermi-LAT) and 20 TeV (H.E.S.S.). In this large-mass regime, our results provide the first constraints on gamma-ray lines from dark matter annihilation.

79 ASTRONOMY AND ASTROPHYSICS↗

Progress on observations of interspecies ion separation in inertial-confinement-fusion implosions via imaging x-ray spectroscopy

We report on the analyses of x-ray-imaging spectroscopy data from experiments to study interspecies ion separation in direct-drive inertial-confinement-fusion experiments on the Omega laser facility. This is a continuation of recent, related research [S. C. Hsu et al., Euro Phys. Lett. 115, 65001 (2016); T. R. Joshi et al., Phys. Plasmas 24, 056305 (2017)]. The targets were argon (Ar)-doped, deuterium (D2)-filled spherical plastic shells of varying D2-Ar relative and total gas pressures. We used a time- and space-integrated spectrometer, streaked crystal spectrometer, and up to three time-gated multi-monochromatic x-ray imagers (MMIs) fielded along different lines of sight to record x-ray spectral features obtained from the implosions. The MMI data were recorded between first-shock convergence and slightly before the neutron bang time. We confirm the presence of interspecies ion separation as reported in our recent work. Extensions to the previous work include (a) the inclusion of shell mix in the data analysis, which slightly changes the amount of inferred species separation, (b) observation of species separation closer to the neutron bang time, and (c) fielding of the particle x-ray temporal diagnostic (PXTD) [H. Sio et al., Rev. Sci. Instrum. 87, 11D701 (2016)] to infer the relative timing between the neutron bang time and peak x-ray emission. Experimentally inferred species separation is compared with radiation-hydrodynamic simulations that include a multi-ion-species transport model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Composition and radiative properties of grains in molecular clouds and accretion disks

We define a model of the compositon and abundances of grains and gases in molecular cloud cores and accretion disks around young stars by employing a wide range of astronomical data and theory, the composition of primitive bodies in the solar system, and solar elemental abundances. In the coldest portions of these objects, we propose that the major grain species include olivine (Fe, Mg, 2SiO4), orthopyroxene (Fe, Mg, SiO3), volatile and refractory organics, water ice, troilite (FeS), and metallic iron. This compositional model differs from almost all previous models of the interstellar medium (ISM) by having organics as the major condensed C species, rather than graphite; by including troilite as a major grain species; and by specifying the mineralogical composition of the condensed silicates. Using a combination of laboratory measurements of optical constants and asymptotic theory, we derive values of the real and imaginary indices of refraction of these grain species over a wavelength range that runs from the vacuum ultraviolet (UV) to the radio domain. The above information on grain properties is used to estimate the Rosseland mean opacity of the grains and their monochromatic opacity.

Pollack, James B.↗

Coherent X-ray Diffraction Imaging of Zeolite Microcrystals

We measured coherent x-ray diffraction (CXD), an emerging technique to obtain three-dimensional internal and external images of crystals, on ZSM-5 zeolite microcrystals to get internal density distribution and to map deformation field of strain. The experiments were performed at the beamline 34-ID-C in Advanced Photon Source at Argonne National Laboratory in the US. The CXD patterns of ZSM-5 zeolite microcrystals with sizes of 2 {mu}m by monochromatic coherent x-rays with energy of 9 keV were obtained under continuously surrounding and Bragg conditions as a function of temperature. The oversampled diffraction patterns are inverted to obtain three-dimensional images of the shapes and internal strain fields of zeolite microcrystals using phase retrieval algorithms of error reduction and a hybrid input-output method. The internal density and strain distribution as a function of temperature are discussed.

36 MATERIALS SCIENCE↗

R-matrix calculations for opacities: I. Methodology and computations

Abstract An extended version of the R -matrix methodology is presented for calculation of radiative parameters for improved plasma opacities. Contrast and comparisons with existing methods primarily relying on the distorted wave approximation are discussed to verify accuracy and resolve outstanding issues, particularly with reference to the opacity project (OP). Among the improvements incorporated are: (i) large-scale Breit–Pauli R -matrix calculations for complex atomic systems including fine structure, (ii) convergent close coupling wave function expansions for the ( e + ion) system to compute oscillator strengths and photoionization cross sections, (iii) open and closed shell iron ions of interest in astrophysics and experiments, (iv) a treatment for plasma broadening of autoionizing resonances as function of energy-temperature-density dependent cross sections, (v) a ‘top-up’ procedure to compare convergence with R -matrix calculations for highly excited levels, and (vi) spectroscopic identification of resonances and bound ( e + ion) levels. The present R -matrix monochromatic opacity spectra are fundamentally different from OP and lead to enhanced Rosseland and Planck mean opacities. An outline of the work reported in other papers in this series and those in progress is presented. Based on the present re-examination of the OP work, opacities of heavy elements might require revisions in high temperature-density plasma sources.

Pradhan, A. K. (ORCID:0000000187753643)↗

XFEL diffraction: Developing processing methods to optimize data quality

Serial crystallography, using either femtosecond X-ray pulses from free-electron laser sources or short synchrotron-radiation exposures, has the potential to reveal metalloprotein structural details while minimizing damage processes. However, deriving a self-consistent set of Bragg intensities from numerous still-crystal exposures remains a difficult problem, with optimal protocols likely to be quite different from those well established for rotation photography. Here several data processing issues unique to serial crystallography are examined. It is found that the limiting resolution differs for each shot, an effect that is likely to be due to both the sample heterogeneity and pulse-to-pulse variation in experimental conditions. Shots with lower resolution limits produce lower-quality models for predicting Bragg spot positions during the integration step. Also, still shots by their nature record only partial measurements of the Bragg intensity. An approximate model that corrects to the full-spot equivalent (with the simplifying assumption that the X-rays are monochromatic) brings the distribution of intensities closer to that expected from an ideal crystal, and improves the sharpness of anomalous difference Fourier peaks indicating metal positions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Feasibility Studies of Parametric X-rays Use in a Medical Environment

Parametric X-rays (PXR) are produced from the interaction of relativistic electrons with the periodic structure of crystal materials. Smooth X-ray energy tunability is achieved by rotating the crystal with respects to the electron beam direction. Experiments at the Rensselaer Polytechnic Institute 60-MeV LINAC produce quasi-monochromatic X-rays (6-35 keV) from various target crystals to include highly oriented pyrolytic graphite (HOPG), LiF, Si, Ge, Cu, and W using electron beam currents up to 6 uA. These experiments demonstrate the first PXR images and some of the merits of thin metallic crystals. Recent experiments with a 100-{mu}m thick Cu crystal improve the Cu PXR (with energy {approx}12 keV) to Cu fluorescence ratio by a factor of 20 compared to a 1 mm-thick Cu crystal. This study uses Monte Carlo techniques to investigate (1) PXR dose compared to emissions from simulated Mo, Rh, and W anodes for mammography applications and (2) electron scattering effects when considering LiF111, Si111, and Cu111 PXR production using electron beams with energies of 20-30 MeV. Advantages in using monochromatic PXR compared to X-rays from Mo and Rh anodes in mammography applications result in a dose per incident photon reduction by a factor of 2. Using 20 MeV electrons, the thinner Cu111 crystal for 15 keV PXR production results in an electron scattering angle of 30.7+/-0.2 mrad offering the best potential for PXR from lower energy electro0008.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-pressure nuclear inelastic scattering with backscattering monochromatization

The capability to perform high-pressure low-temperature nuclear inelastic scattering on 125 Te and 121 Sb with a sapphire backscattering monochromator is presented. This technique was applied to measure nuclear inelastic scattering in TeO 2 at pressures up to 10 GPa and temperatures down to 25 K. The evaluated partial Te densities of phonon states were compared with theoretical calculations and with Raman scattering measured under the same conditions. The high-pressure cell developed in this work can also be used for other techniques at pressures up to at least 100 GPa.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cassini Radio and Plasma Wave Observations at Saturn

Results are presented from the Cassini radio and plasma wave instrument during the approach and first few orbits around Saturn. During the approach the intensity modulation of Saturn Kilometric Radiation (SKR) showed that the radio rotation period of Saturn has increased to 10 hr 45 min plus or minus 36 sec, about 6 min longer than measured by Voyager in 1980-81. Also, many intense impulsive radio signals called Saturn Electrostatic Discharges (SEDs) were detected from saturnian lightning, starting as far as 1.08 AU from Saturn, much farther than terrestrial lightning can be detected from Earth. Some of the SED episodes have been linked to cloud systems observed in Saturn s atmosphere by the Cassini imaging system. Within the magnetosphere plasma wave emissions have been used to construct an electron density profile through the inner region of the magnetosphere. With decreasing radial distance the electron density increases gradually to a peak of about 100 per cubic centimeter near the outer edge of the A ring, and then drops precipitously to values as low as .03 per cubic centimeter over the rings. Numerous nearly monochromatic whistler-mode emissions were observed as the spacecraft passed over the rings that are believed to be produced by meteoroid impacts on the rings. Whistlermode emissions, similar to terrestrial auroral hiss were also observed over the rings, indicating that an electrodynamic interaction, similar to auroral particle acceleration, may be occurring in or near the rings. During the Titan flybys Langmuir probe and plasma wave measurements provided observations of the density and temperature in Titan's ionosphere.

Gurnett, D. A.↗

Modeling the gain of inner-shell X-ray laser transitions in neon, argon, and copper driven by X-ray free electron laser radiation using photo-ionization and photo-excitation processes

Using an X-ray free electron laser (XFEL) at 960 eV to photo-ionize the 1s electron in neutral neon followed by lasing on the 2p-1s transition in singly-ionized neon, an inner-shell X-ray laser was demonstrated at 849 eV in singly-ionized neon gas several years ago. It took decades to demonstrate this scheme, because it required a very strong X-ray source that could photo-ionize the 1s (K shell) electron in neon on a timescale comparable to the intrinsic Auger lifetime in neon of 2 fs. In this paper, we model the neon inner shell X-ray laser under similar conditions to those used in the XFEL experiments at the SLAC Linac Coherent Light Source (LCLS), and show how we can improve the efficiency of the neon laser and reduce the drive requirements by tuning the XFEL to the 1s-3p transition in neutral neon in order to create gain on the 2p-1s line in neutral neon. We also show how the XFEL could be used to photo-ionize L-shell electrons to drive gain on n = 3–2 transitions in singly-ionized Ar and Cu plasmas. These bright, coherent, and monochromatic X-ray lasers may prove very useful for doing high-resolution spectroscopy and for studying non-linear process in the X-ray regime.

36 MATERIALS SCIENCE↗

A simple method for mitigating error in the fixed-offset of a double-crystal monochromator

In order to maintain a constant monochromatic synchrotron X-ray beam height for all energies, the separation between the crystals of a double-crystal monochromator is typically adjusted, via translation of the second crystal, while X-ray energy is varied, via rotation of the crystal pair. The ability to accurately translate the second crystal requires precise knowledge of the separation between the two crystals and, when present, crystal miscuts. Here, a simple method for calibrating the crystal gap from measured variation in the X-ray beam height that eliminates error in the fixed beam offset is provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗