Search NASA⌕ Search

SEARCH · Search NASA

Results for “Methods:data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

TH-E-9A-01: Medical Physics 1.0 to 2.0, Session 4: Computed Tomography, Ultrasound and Nuclear Medicine

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. CT 2.0: CT has been undergoing a dramatic transition in the last few decades. While the changes in the technology merits discussions of their own, an important question is how clinical medical physicists are expected to effectively engage with the new realities of CT technology and practice. Consistent with the upcoming paradigm of Medical Physics 2.0, this CT presentation aims to provide definitions and demonstration of the components of the new clinical medical physics practice pertaining CT. The topics covered include physics metrics and analytics that aim to provide higher order clinicallyrelevant quantification of system performance as pertains to new (and not so new) technologies. That will include the new radiation and dose metrics (SSDE, organ dose, risk indices), image quality metrology (MTF/NPS/d’), task-based phantoms, and the effect of patient size. That will follow with a discussion of the testing implication of new CT hardware (detectors, tubes), acquisition methods (innovative helical geometries, AEC, wide beam CT, dual energy, inverse geometry, application specialties), and image processing and analysis (iterative reconstructions, quantitative CT, advanced renditions). The presentation will conclude with a discussion of clinical and operational aspects of Medical Physics 2.0 including training and communication, use optimization (dose and technique factors), automated analysis and data management (automated QC methods, protocol tracking, dose monitoring, issue tracking), and meaningful QC considerations. US 2.0: Ultrasound imaging is evolving at a rapid pace, adding new imaging functions and modes that continue to enhance its clinical utility and benefits to patients. The ultrasound talk will look ahead 10–15 years and consider how medical physicists can bring maximal value to the clinical ultrasound practices of the future. The roles of physics in accreditation and regulatory compliance, image quality and exam optimization, clinical innovation, and education of staff and trainees will all be considered. A detailed examination of expected technology evolution and impact on image quality metrics will be presented. Clinical implementation of comprehensive physics services will also be discussed. Nuclear Medicine 2.0: Although the basic science of nuclear imaging has remained relatively unchanged since its inception, advances in instrumentation continue to advance the field into new territories. With a great number of these advances occurring over the past decade, the role and testing strategies of clinical nuclear medicine physicists must evolve in parallel. The Nuclear Medicine 2.0 presentation is designed to highlight some of the recent advances from a clinical medical physicist perspective and provide ideas and motivation for designing better evaluation strategies. Topics include improvement of traditional physics metrics and analytics, testing implications of hybrid imaging and advanced detector technologies, and strategies for effective implementation into the clinic. Learning Objectives: Become familiar with new physics metrics and analytics in nuclear medicine, CT, and ultrasound. To become familiar with the major new developments of clinical physics support. To understand the physics testing implications of new technologies, hardware, software, and applications. Identify approaches for implementing comprehensive medical physics services in future imaging practices.

60 APPLIED LIFE SCIENCES↗

Optimizing galaxy samples for clustering measurements in photometric surveys

When analysing galaxy clustering in multiband imaging surveys, there is a trade-off between selecting the largest galaxy samples (to minimize the shot noise) and selecting samples with the best photometric redshift (photo-$z$) precision, which generally includes only a small subset of galaxies. In this paper, we systematically explore this trade-off. Our analysis is targeted towards the third-year data of the Dark Energy Survey (DES), but our methods hold generally for other data sets. Using a simple Gaussian model for the redshift uncertainties, we carry out a Fisher matrix forecast for cosmological constraints from angular clustering in the redshift range $z$ = 0.2–0.95. We quantify the cosmological constraints using a figure of merit (FoM) that measures the combined constraints on $Ωm$ and $σ_8$ in the context of Λ cold dark matter ($Λ$CDM) cosmology. We find that the trade-off between sample size and photo-z precision is sensitive to (1) whether cross-correlations between redshift bins are included or not, and (2) the ratio of the redshift bin width $δz$ to the photo-$z$ precision $σ_z$. When cross-correlations are included and the redshift bin width is allowed to vary, the highest FoM is achieved when $δz$ ~ $σ_z$. We find that for the typical case of 5-10 redshift bins, optimal results are reached when we use larger, less precise photo-z samples, provided that we include cross-correlations. For samples with higher $σ_z$, the overlap between redshift bins is larger, leading to higher cross-correlation amplitudes. This leads to the self-calibration of the photo-z parameters and therefore tighter cosmological constraints. These results can be used to help guide galaxy sample selection for clustering analysis in ongoing and future photometric surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Identifying the Oil Price-Macroeconomy Relationship: An Empirical Mode Decomposition Analysis of U.S. Data

This work applies the empirical mode decomposition (EMD) method to data on real quarterly oil price (West Texas Intermediate - WTI) and U.S. gross domestic product (GDP). This relatively new method is adaptive and capable of handling non-linear and non-stationary data. Correlation analysis of the decomposition results was performed and examined for insights into the oil-macroeconomy relationship. Several components of this relationship were identified. However, the principal one is that the medium-run cyclical component of the oil price exerts a negative and exogenous influence on the main cyclical component of the GDP. This can be interpreted as the supply-driven or supply-shock component of the oil price-GDP relationship. In addition, weak correlations suggesting a lagging demand-driven, an expectations-driven, and a long-run supply-driven component of the relationship were also identified. Comparisons of these findings with significant oil supply disruption and recession dates were supportive. The study identified a number of lessons applicable to recent oil market events, including the eventuality of persistent economic and price declines following a long oil price run-up. In addition, it was found that oil-market related exogenous events are associated with short- to medium-run price implications regardless of whether they lead to actual supply disruptions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The CosmoVerse White Paper: Addressing observational tensions in cosmology with systematics and fundamental physics.

The standard model of cosmology has provided a good phenomenological description of a wide range of observations both at astrophysical and cosmological scales for several decades. This concordance model is constructed by a universal cosmological constant and supported by a matter sector described by the standard model of particle physics and a cold dark matter contribution, as well as very early-time inflationary physics, and underpinned by gravitation through general relativity. There have always been open questions about the soundness of the foundations of the standard model. However, recent years have shown that there may also be questions from the observational sector with the emergence of differences between certain cosmological probes. In this White Paper, we identify the key objectives that need to be addressed over the coming decade together with the core science projects that aim to meet these challenges. These discordances primarily rest on the divergence in the measurement of core cosmological parameters with varying levels of statistical confidence. These possible statistical tensions may be partially accounted for by systematics in various measurements or cosmological probes but there is also a growing indication of potential new physics beyond the standard model. After reviewing the principal probes used in the measurement of cosmological parameters, as well as potential systematics, we discuss the most promising array of potential new physics that may be observable in upcoming surveys. We also discuss the growing set of novel data analysis approaches that go beyond traditional methods to test physical models. These new methods will become increasingly important in the coming years as the volume of survey data continues to increase, and as the degeneracy between predictions of different physical models grows. There are several perspectives on the divergences between the values of cosmological parameters, such as the model-independent probes in the late Universe and model-dependent measurements in the early Universe, which we cover at length. The White Paper closes with a number of recommendations for the community to focus on for the upcoming decade of observational cosmology, statistical data analysis, and fundamental physics developments.

Dienes, Keith [Univ. of Arizona, Tucson, AZ (Unite↗

Quantifying Transient Uncertainty in the BEAVRS Benchmark Using Time Series Analysis Methods

Advances in computation have brought about significant improvements in creating fast-running high-fidelity simulations of nuclear cores. The BEAVRS benchmark is a highly-detailed PWR specification with two cycles of measured operational data used to validate high-fidelity core analysis methods. This PWR depletion benchmark captures the fine details of the LWR fuel assemblies, burnable absorbers, in-core fission detectors, core loading and shuffling patterns. Specifically, 58 of the 193 assemblies contain in-core detectors with measurements taken over 61 axial positions every month. These detectors are U-235 fission chambers with slightly varying mass of U-235. The collected signals are normalized on a given assembly permitting full core comparisons. The fuel layout for cycle 1 and instrument tube locations for the reactor are given in figures 1 and 2 respectively. Through a series of data processing and comparisons, it was shown that axially integrated radial maps of reaction rates were in close agreement between provided detector data and calculated data. More recently, the focus of the BEAVRS project has been on quantifying uncertainty to further assess the validity of aforementioned results. A close investigation of sources of error shows that uncertainties from operational nuclear data arise primarily from data measurements and processing. While the errors in axial realignment and interpolation seem significant, these sources affect only a small subset of data points near grid spacers and do not persist throughout the entire core. Instead, measurement uncertainty from detector count rates and radial integration dominate the uncertainty in measured data are determined as the most significant sources of error. This uncertainty analysis treated each given burnup step as independent of comparable data at neighboring burnup steps. More recent work has been targeted at understanding how reaction rates vary over time, in order to determine whether calculated reaction rates follow any observable trends. This abstract hones in on transient uncertainty quantification, in order to compare observed data against models for transient behavior. The first section of the paper uses linear regression tools to fit operational data, while the latter portion of the paper explores more complex simulation tools to fit operational data. Ultimately, the BEAVRS benchmark aims to serve as a true non-proprietary international benchmark for the validation of high-fidelity tools. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MetaboTools: A comprehensive toolbox for analysis of genome-scale metabolic models

Metabolomic data sets provide a direct read-out of cellular phenotypes and are increasingly generated to study biological questions. Previous work, by us and others, revealed the potential of analyzing extracellular metabolomic data in the context of the metabolic model using constraint-based modeling. With the MetaboTools, we make our methods available to the broader scientific community. The MetaboTools consist of a protocol, a toolbox, and tutorials of two use cases. The protocol describes, in a step-wise manner, the workflow of data integration, and computational analysis. The MetaboTools comprise the Matlab code required to complete the workflow described in the protocol. Tutorials explain the computational steps for integration of two different data sets and demonstrate a comprehensive set of methods for the computational analysis of metabolic models and stratification thereof into different phenotypes. The presented workflow supports integrative analysis of multiple omics data sets. Importantly, all analysis tools can be applied to metabolic models without performing the entire workflow. Taken together, the MetaboTools constitute a comprehensive guide to the intra-model analysis of extracellular metabolomic data from microbial, plant, or human cells. In conclusion, this computational modeling resource offers a broad set of computational analysis tools for a wide biomedical and non-biomedical research community.

59 BASIC BIOLOGICAL SCIENCES↗

TH-A-BRC-01: AAPM TG-135U1 QA for Robotic Radiosurgery

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗

TH-A-BRC-03: AAPM TG218: Measurement Methods and Tolerance Levels for Patient-Specific IMRT Verification QA

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗

Iterative Bragg peak removal on X-ray absorption spectra with automatic intensity correction

This study introduces a novel iterative Bragg peak removal with automatic intensity correction (IBR-AIC) methodology for X-ray absorption spectroscopy (XAS), specifically addressing the challenge of Bragg peak interference in the analysis of crystalline materials. The approach integrates experimental adjustments and sophisticated post-processing, including an iterative algorithm for robust calculation of the scaling factor of the absorption coefficients and efficient elimination of the Bragg peaks, a common obstacle in accurately interpreting XAS data, particularly in crystalline samples. The method was thoroughly evaluated on dilute catalysts and thin films, with fluorescence mode and large-angle rotation. The results underscore the technique's effectiveness, adaptability and substantial potential in improving the precision of XAS data analysis. While demonstrating significant promise, the method does have limitations related to signal-to-noise ratio sensitivity and the necessity for meticulous angle selection during experimentation. Overall, IBR-AIC represents a significant advancement in XAS, offering a pragmatic solution to Bragg peak contamination challenges, thereby expanding the applications of XAS in understanding complex materials under diverse experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Developing High-Resolution Constrained Variational Analysis of Vertical Velocity and Advective Tendencies within the Range of ARM Scanning Radars at the SGP

Research progress has been made in two areas. One is about the incorporation of the ARM variationally constrained objective analysis method into the WRF GSI data assimilation system. The other is the development of high resolution ARM data and its applications. Specially, we developed a new data assimilation algorithm by adding dynamical constraints to the WRF GSI data assimilation system using hybrid ensemble variational system to derive 3-D fields of atmospheric dynamics and thermodynamics over the ARM SGP sites. We also developed 4x4 km high-resolution constrained variational analysis data over the SGP during the PECAN and made them available to the community. Details are in the attached report.

54 ENVIRONMENTAL SCIENCES↗

TH-A-BRC-00: New Task Groups for External Beam QA: An Overview

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗

TH-A-BRC-02: AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗

Machine Learning in the Context of Laser-Induced Breakdown Spectroscopy

The integration of machine learning (ML) with Laser-Induced Breakdown Spectroscopy (LIBS) has revolutionized the analytical capabilities of LIBS. The combi-nation of both methods enables more accurate and efficient data analysis. While LIBS itself is a powerful technique for elemental analysis, the vast amount of spectral data it generates can be hard to interpret. Machine learning addresses these challenges by leveraging algorithms that can learn from data, identify patterns, and make predictions without explicit programming for the interpretation of each specific task. In LIBS application, ML techniques are used to enhance various analytical processes. For example, ML algorithms can classify materials based on their spectral fingerprints, predict the concentration of elements in a sample, and identify underlying patterns within complex datasets. Here, this application improves the precision of LIBS analyses while significantly reducing the time required for data processing and interpretation. In this chapter, the fundamental concepts of ML will be discussed first. Following this, the process of data splitting and the importance of feature selection will be examined. Several machine learning methods will then be closely examined, exploring how each can benefit LIBS analysis and highlighting their respective advantages and shortcomings. This structured approach will provide a comprehensive understanding of the integration of ML in the context of LIBS analysis.

47 OTHER INSTRUMENTATION↗

TopoSZ: Preserving Topology in Error-Bounded Lossy Compression

Existing error-bounded lossy compression techniques control the pointwise error during compression to guarantee the integrity of the decompressed data. However, they typically do not explicitly preserve the topological features in data. When performing post hoc analysis with decompressed data using topological methods, preserving topology in the compression process to obtain topologically consistent and correct scientific insights is desirable. In this paper, we introduce TopoSZ, an error-bounded lossy compression method that preserves the topological features in 2D and 3D scalar fields. Specifically, we aim to preserve the types and locations of local extrema as well as the level set relations among critical points captured by contour trees in the decompressed data. The main idea is to derive topological constraints from contour-tree-induced segmentation from the data domain, and incorporate such constraints with a customized error-controlled quantization strategy from the SZ compressor (version 1.4). In conclusion, our method allows users to control the pointwise error and the loss of topological features during the compression process with a global error bound and a persistence threshold.

97 MATHEMATICS AND COMPUTING↗

Outsourced probe data effectiveness on signalized arterials

This paper presents results of an I-95 Corridor Coalition sponsored project to assess the ability of outsourced vehicle probe data to provide accurate travel time on signalized roadways for the purposes of real-time operations as well as performance measures. The quality of outsourced probe data on freeways has led many departments of transportation to consider such data for arterial performance monitoring. From April 2013 through June of 2014, the University of Maryland Center for Advanced Transportation Technology gathered travel times from several arterial corridors within the mid-Atlantic region using Bluetooth traffic monitoring (BTM) equipment, and compared these travel times with the data reported to the I95 Vehicle Probe Project (VPP) from an outsourced probe data vendor. The analysis consisted of several methodologies: (1) a traditional analysis that used precision and bias speed metrics; (2) a slowdown analysis that quantified the percentage of significant traffic disruptions accurately captured in the VPP data; (3) a sampled distribution method that uses overlay methods to enhance and analyze recurring congestion patterns. (4) Last, the BTM and VPP data from each 24-hour period of data collection were reviewed by the research team to assess the extent to which VPP captured the nature of the traffic flow. Based on the analysis, probe data is recommended only on arterial roadways with signal densities (measured in signals per mile) up to one, and it should be tested and used with caution for signal densities between one and two, and is not recommended when signal density exceeds two.

33 ADVANCED PROPULSION SYSTEMS↗

Appalachian Basin Play Fairway Analysis Analyses and Results

*This submission updates a 2015 submission for the utilization analysis (https://gdr.openei.org/submissions/623)* The files document the analysis of utilization potential in support of Phase 1 Low Temperature Geothermal Play Fairway Analysis for the Appalachian Basin. This 2016 submission includes data pertinent to the methods and results of an analysis of the Surface Levelized Cost of Heat (SLCOH) for US Census Bureau 'Places' within the study area. The SLCOHis was calculated using a modification of a program called GEOPHIRES, available at http://koenraadbeckers.net/geophires/index.php. In addition to calculating SLCOH, this task also identified many industrial sites that may be prospects for use of a geothermal district heating system, based on their size and industry, rather than on the SLCOH. An industry sorted listing and maps of the sites have been plotted as a layer onto different iterations of maps combining the three geologic risk factors (Thermal Quality, Natural Reservoir Quality, and Risk of Seismicity). In addition, a shapefile of the industrial sites is also included with 7 associated files. Supporting files are also supplied.

15 GEOTHERMAL ENERGY↗

Integrating Data Clustering and Visualization for the Analysis of 3D Gene Expression Data

The recent development of methods for extracting precise measurements of spatial gene expression patterns from three-dimensional (3D) image data opens the way for new analyses of the complex gene regulatory networks controlling animal development. We present an integrated visualization and analysis framework that supports user-guided data clustering to aid exploration of these new complex datasets. The interplay of data visualization and clustering-based data classification leads to improved visualization and enables a more detailed analysis than previously possible. We discuss (i) integration of data clustering and visualization into one framework; (ii) application of data clustering to 3D gene expression data; (iii) evaluation of the number of clusters k in the context of 3D gene expression clustering; and (iv) improvement of overall analysis quality via dedicated post-processing of clustering results based on visualization. We discuss the use of this framework to objectively define spatial pattern boundaries and temporal profiles of genes and to analyze how mRNA patterns are controlled by their regulatory transcription factors.

60 APPLIED LIFE SCIENCES↗

Probabilistic Economic Valuation of Safety Margin Management

The goal of this project was to explore a new methodology for evaluation of potential safety margin upgrades to add a new instrument to the Risk Informed Safety Margin Characterization (RISMC) toolkit. To this end, the RAVEN code developed by the Idaho National Laboratory was used to perform a cost-benefit analysis of several potential power plant safety upgrades to compare the material cost of the upgrades with the probabilistic benefit of avoiding accident scenario consequences to find the most cost-effective safety upgrades. By coupling RAVEN to MELCOR to drive Monte-Carlo method stochastic parameter analysis and using data from existing nuclear codes, as well as MELCOR’s radionuclide relocation tracking capabilities, the radionuclide release source term activity in a severe accident scenario can be estimated. Severe Accident Mitigation upgrades were benchmarked against the Hardened Containment Ventilation upgrade mandated by the USNRC for Mk1 BWRs using dollars spent per Curie of release prevented as a metric by which to evaluate the economic efficacy of the upgrades. Additionally, Fault Tree/Event Tree-based analyses were performed to compare older methods of evaluation to the methodology pioneered in this work, and Monthly Operating Report (MORP) outage data was analyzed for insights into power plant outage optimization and reduction.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗