Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Oxidation characteristics of gasoline direct-injection (GDI) engine soot: Catalytic effects of ash and modified kinetic correlation

In this paper, experimental analyses are conducted into the GDI soot oxidation characteristics as dependent on engine operating conditions. Soot is sampled at various engine operating conditions of a commercial 2.4 L GDI engine with a naturally aspirated, homogeneous, and stoichiometric operation strategy. The oxidation reactivity, ash composition, and carbon nanostructure of the GDI soot samples are analyzed using thermogravimetric analysis (TGA), scanning electron microscope–energy-dispersive spectroscopy (SEM-EDS), high-resolution transmission electron microscopy (HR-TEM), and Raman spectroscopy. Based on the analyses, a global GDI soot oxidation mechanism is proposed which includes the effects of soluble organic fractions (SOF)/weakly bonded carbon (WBC), and three types of ash on GDI soot oxidation. The results show that GDI soot contains an order of magnitude higher ash fraction than does conventional diesel soot, and oxidation reactivity is significantly enhanced by the catalytic effects of ash, as a function of ash content in soot. A modified empirical kinetic correlation for GDI soot oxidation is suggested on the basis of the results, and the modified kinetic correlation predicts the GDI soot oxidation rate accurately for various engine operation points at wide ranges of soot conversion and temperature without modifying kinetic parameters. The kinetic parameters are determined from isothermal and non-isothermal thremogravimetric analysis (TGA) soot oxidation tests; the methods are elucidated in detail.

33 ADVANCED PROPULSION SYSTEMS↗

Effect of processing parameters on the formation of C{sub f}/LAS composites/Ag−Cu−Ti/TC4 brazed joint

C{sub f}/LAS composites were successfully jointed to TC4 alloy with Ag−Cu−Ti filler by vacuum brazing. The interfacial microstructure of TC4/C{sub f}/LAS composites joints was characterized by employing scanning electron microscope (SEM), energy dispersive spectrometer (EDS), X-diffraction (XRD) and transmission electron microscopy (TEM). The determination of the thin interfacial reaction layer (TiSi{sub 2} + TiC layer) was realized by TEM. The effect of holding time on the interfacial microstructure and shear strength were investigated. With the increasing holding time, the thickness of diffusion layer, Ti{sub 3}Cu{sub 4} layer, and TiSi{sub 2} + TiC layer increased obviously, on the contrary, that of Ti−Cu intermetallic compound layers decreased gradually. Besides, blocky Ti{sub 3}Cu{sub 4} phase was coarsened when the joint was brazed at 890 °C for 20 min, which deteriorated the mechanical properties of the joint dramatically. The interfacial evolution of TC4/C{sub f}/LAS composites joint and the formation of TiSi{sub 2}, TiC, Ti{sub 3}Cu{sub 4}, TiCu and Ti{sub 2}Cu phases were expounded. The maximum shear strength of 26.4 MPa was obtained when brazed at 890 °C for 10 min. - Highlights: •The thin interface reaction layer was determined to be TiSi{sub 2} + TiC layer by TEM. •Holding time had influence on the interfacial microstructure and joint properties. •Microstructural evolution mechanism and reactions of brazed joints were expounded.

36 MATERIALS SCIENCE↗

Entangled Photon Spectroscopy

Conspectus The enhanced interest in quantum-related phenomena has provided new opportunities for chemists to push the limits of detection and analysis of chemical processes. As some have called this the second quantum revolution, a time has come to apply the rules learned from previous research in quantum phenomena toward new methods and technologies important to chemists. While there has been great interest recently in quantum information science (QIS), the quest to understand how nonclassical states of light interact with matter has been ongoing for more than two decades. Our entry into this field started around this time with the use of materials to produce nonclassical states of light. Here, the process of multiphoton absorption led to photon-number squeezed states of light, where the photon statistics are sub-Poissonian. In addition to the great interest in generating squeezed states of light, there was also interest in the formation of entangled states of light. While much of the effort is still in foundational physics, there are numerous new avenues as to how quantum entanglement can be applied to spectroscopy, imaging, and sensing. These opportunities could have a large impact on the chemical community for a broad spectrum of applications. Here, we discuss the use of entangled (or quantum) light for spectroscopy as well as applications in microscopy and interferometry. The potential benefits of the use of quantum light are discussed in detail. From the first experiments in porphyrin dendrimer systems by Dr. Dong-Ik Lee in our group to the measurements of the entangled two photon absorption cross sections of biological systems such as flavoproteins, the usefulness of entangled light for spectroscopy has been illustrated. These early measurements led the way to more advanced measurements of the unique characteristics of both entangled light and the entangled photon absorption cross-section, which provides new control knobs for manipulating excited states in molecules. The first reports of fluorescence-induced entangled processes were in organic chromophores where the entangled photon cross-section was measured. These results would later have widespread impact in applications such as entangled two-photon microscopy. From our design, construction and implementation of a quantum entangled photon excited microscope, important imaging capabilities were achieved at an unprecedented low excitation intensity of 10 7 photons/s, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. New reports have also illustrated an advantage of nonclassical light in Raman imaging as well. From a standpoint of more precise measurements, the use of entangled photons in quantum interferometry may offer new opportunities for chemistry research. Experiments that combine molecular spectroscopy and quantum interferometry, by utilizing the correlations of entangled photons in a Hong–Ou–Mandel (HOM) interferometer, have been carried out. The initial experiment showed that the HOM signal is sensitive to the presence of a resonant organic sample placed in one arm of the interferometer. In addition, parameters such as the dephasing time have been obtained with the opportunity for even more advanced phenomenology in the future.

36 MATERIALS SCIENCE↗

Multiscale Mechanical Characterization of Mineral-Reinforced Wood Cell Walls

Studying the multiscale mechanics of bio-based composites offers unique perspectives on underlying structure–property relations. Cellular materials, such as wood, are highly organized, hierarchical assemblies of load-bearing structural elements that respond to mechanical stimuli at the microscopic, mesoscopic and macroscopic scale. In this study, we modified oak wood with nanocrystalline ferrihydrite, a widespread ferric oxyhydroxide mineral, and characterized the resulting mechanical properties of the composite at various levels of organization. Ferrihydrite nanoparticles were deposited inside the wood cell wall by an in situ chemical reaction, resulting in increased stiffness and hardness of the functionalized secondary cell wall, as evidenced by region-specific nanoindentation tests under an electron microscope. Chemically modified and pristine wood samples were characterized by using atomic force microscopy in the bimodal frequency modulation mode, which produced topographical images from the cellular ultrastructure with high lateral resolution and localized nanomechanical information across distinct cell wall layers. In conclusion, despite mineral reinforcement at the cell wall level, the macroscopic fracture behavior examined through three-point flexural testing remained unchanged upon modification, as cell–cell adhesion could be impaired by harsh chemical conditions.

Cells↗

Visualization of Aluminum Ions at the Mica Water Interface Links Hydrolysis State-to-Surface Potential and Particle Adhesion

When hydrolyzable cations such as aluminum interact with solid-water interfaces, macroscopic interfacial properties (e.g., surface charge and potential) and interfacial phenomena (e.g., particle adhesion) become tightly linked with the microscopic details of ion adsorption and speciation. We use in situ atomic force microscopy to directly image individual aluminum ions at a mica-water interface and show how adsorbate populations change with pH and aluminum activity. Complementary streaming potential measurements then allow us to build a triple layer model (TLM) that links surface potentials to adsorbate populations, via equilibrium binding constants. Our model predicts that hydrolyzed species dominate the mica-water interface, even when unhydrolyzed species dominate the solution. Ab initio molecular dynamics (AIMD) simulations confirm that aluminum hydrolysis is strongly promoted at the interface. The TLM indicates that hydrolyzed adsorbates are responsible for surface-potential inversions, and we find strong correlations between hydrolyzed adsorbates and particle-adhesion forces, suggesting that these species mediate adhesion by chemical bridging.

Legg, Benjamin A.↗

Real-time studies of ferroelectric domain switching: a review

Ferroelectric materials have been utilized in a broad range of electronic, optical, and electromechanical applications and hold the promise for the design of future high-density nonvolatile memories and multifunctional nano-devices. The applications of ferroelectric materials stem from the ability to switch polarized domains by applying an electric field, and therefore a fundamental understanding of the switching dynamics is critical for design of practical devices. In this review, we summarize the progress in the study of the microscopic process of ferroelectric domain switching using recently developed in situ transmission electron microscopy (TEM). We first briefly introduce the instrumentation, experimental procedures, imaging mechanisms, and analytical methods of the state-of-the-art in situ TEM techniques. The application of these techniques to studying a wide range of complex switching phenomena, including domain nucleation, domain wall motion, domain relaxation, domain-defect interaction, and the interplay between different types of domains, is demonstrated. The underlying physics of these dynamic processes are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enabling direct nanoscale observations of biological reactions with dynamic TEM

Biological processes can occur over a wide range of spatial and temporal scales; from femtoseconds to hours and from angstroms to meters. Although no single experimental method can fully cover this entire phase space, many new biological insights can be expected from a better understanding of the processes that occur on the very fast timescales and very small length scales. In this regard, new instruments that use fast x-ray or electron pulses are now available that are expected to reveal new mechanistic insights for macromolecular protein dynamics. To ensure that any observed conformational change is physiologically relevant and not constrained by three-dimensional crystal packing, it would be preferable for experiments to utilize smaller protein samples such as single particles or two-dimensional crystals that mimic the target protein’s native environment. These samples aren’t typically amenable to x-ray analysis, but transmission electron microscopy has successfully imaged such sample geometries for over 40 years and permits data acquisition using both direct imaging and diffraction modes. While conventional transmission electron microscopes (TEM) have only visualized biological samples with atomic resolution in an arrested or frozen state, the recent development of the dynamic TEM (DTEM) extends electron microscopy capabilities into dynamics. A new 2nd generation DTEM that is currently being constructed has the potential to observe live biological processes with unprecedented spatiotemporal resolution by using pulsed electron packets to probe the sample on the micro- and nanosecond timescale. In addition to the enhanced temporal resolution, the DTEM also operates in the pump-probe regime that can permit visualizing reactions propagating in real-time. This article reviews the experimental parameters necessary for coupling DTEM with in situ liquid microscopy to allow direct imaging of protein conformational dynamics in a fully hydrated environment.

Dynamic TEM↗

Electron Microscopy Laboratory MST-6: Instruments and Capabilities [Slides]

The Electron Microscopy Laboratory (EML) is a lab-wide facility, overseen by MST-6, that is available for use by qualified users. In FY12 the EML service contract costs were covered by funds from LDRD, BES, NE and other programs. Users can be trained to use the equipment independently or work collaboratively with other trained users or EML staff. Users are charged for the labor portion of their training. Most electron microscopy is done by staff or post-docs but some students are performing microscopy, particularly SEM. In the Materials Science Complex (MSC), there are two optical microscopes, two scanning electron microscopes (SEM’s), a SEM/ FIB (a SEM with a focused ion beam (FIB) column added), three transmission electron microscopes (TEM’s) and sample preparation equipment.

36 MATERIALS SCIENCE↗

Fluorescence Microscopy Denoising (FMD) dataset

We created a dataset - the Fluorescence Microscopy Denoising (FMD) dataset - that is dedicated to Poisson-Gaussian denoising. The dataset consists of 12,000 real fluorescence microscopy images obtained with commercial confocal, two-photon, and wide-field microscopes and representative biological samples such as BPAE cells, zebrafish, and mouse brain tissues. We use image averaging to effectively obtain ground truth images and 60,000 noisy images with different noise levels.

Image Denoising↗

Effects of Initial Powder Size on the Mechanical Properties and Microstructure of As-Extruded GRCop-84

GRCop-84 was developed to meet the mechanical and thermal property requirements for advanced regeneratively cooled rocket engine main combustion chamber liners. It is a ternary Cu- Cr-Nb alloy having approximately 8 at% Cr and 4 at% Nb. The chromium and niobium constituents combine to form 14 vol% Cr2Nb, the strengthening phase. The alloy is made by producing GRCop-84 powder through gas atomization and consolidating the powder using extrusion, hot isostatic pressing (HIP) or vacuum plasma spraying (VPS). GRCop-84 has been selected by Rocketdyne, Ratt & Wlutney and Aerojet for use in their next generation of rocket engines. GRCop-84 demonstrates favorable mechanical and thermal properties at elevated temperatures. Compared to NARloy-Z, the currently used inaterial in the Space Shuttle, GRCop-84 has approximately twice the yield strength, 10-1000 times the creep life, and 1.5-2.5 times the low cycle fatigue life. The thermal expansion of GRCop-84 is 7515% less than NARloy-Z which minimizes thermally induced stresses. The thermal conductivity of the two alloys is comparable at low temperature but NARloy-Z has a 20-50 W/mK thermal conductivity advantage at typical rocket engine hot wall temperatures. GRCop-84 is also much more microstructurally stable than NARloy-Z which translates into better long term stability of mechanical properties. Previous research into metal alloys fabricated by means of powder metallurgy (PM), has demonstrated that initial powder size can affect the microstructural development and mechanical properties of such materials. Grain size, strength, ductility, size of second phases, etc., have all been shown to vary with starting powder size in PM-alloys. This work focuses on characterizing the effect of varying starting powder size on the microstructural evolution and mechanical properties of as- extruded GRCop-84. Tensile tests and constant load creep tests were performed on extrusions of four powder meshes: +140 mesh (great3er than l05 micron powder size), -140 mesh (less than or equal to 105 microns), -140 plus or minus 270 (53 - 105 microns), and - 270 mesh (less than or equal to 53 microns). Samples were tested in tension at room temperature and at 500 C (932 F). Creep tests were performed under vacuum at 500 C using a stress of 111 MPa (16.1 ksi). The fracture surfaces of selected samples from both tests were studied using a Scanning Electron Microscope (SEM). The as-extruded materials were also studied, using both optical microscopy and SEM analysis, to characterize changes within the microstructure.

Okoro, Chika L.↗

Light Microscopy Module Fan Disturbance Characterized Through Microgravity Emissions Laboratory Testing

A Light Microscopy Module (LMM) is being engineered, designed, and developed at the NASA Glenn Research Center. The LMM is planned as a remotely controllable on-orbit microscope subrack facility, allowing flexible scheduling and control of physical science and biological science experiments within Glenn s Fluids Integrated Rack on the International Space Station. The LMM concept is a modified commercial research imaging light microscope with powerful laser-diagnostic hardware and interfaces, creating a one-of-a-kind, state-of-the-art microscopic research facility. The microscope will house several different objectives, corresponding to magnifications of 10, 40, 50, 63, and 100. Features of the LMM include high-resolution color video microscopy, brightfield, darkfield, phase contrast, differential interference contrast, spectrophotometry, and confocal microscopy combined in a single configuration. Also, laser tweezers are integrated with the diagnostics as a sample manipulation technique. As part of the development phase of the LMM, it was necessary to quantify the microgravity disturbances generated by the control box fan. Isolating the fan was deemed necessary to reduce the fan speed harmonic amplitudes and to eliminate any broadband disturbances across the 60- to 70-Hz and 160- to 170-Hz frequency ranges. The accelerations generated by a control box fan component of the LMM were measured in the Microgravity Emissions Laboratory (MEL). The MEL is a low-frequency measurement system developed to simulate and verify the on-orbit International Space Station (ISS) microgravity environment. The accelerations generated by various operating components of the ISS, if too large, could hinder the science performed onboard by disturbing the microgravity environment. The MEL facility gives customers a test-verified way of measuring their compliance with ISS limitations on vibratory disturbance levels. The facility is unique in that inertial forces in 6 degrees of freedom can be characterized simultaneously for an operating test article. Vibratory disturbance levels are measured for engineering or flight-level hardware following development from component to subassembly through the rack-level configuration. The MEL can measure accelerations as small as 10-7g, the accuracy needed to confirm compliance with ISS requirements.

McNelis, Anne M.↗

Studies of SmCo5/Fe nanocomposite magnetic bilayers with magnetic soft x-ray transmission microscopy

A hard/soft SmCo{sub 5}/Fe nanocomposite magnetic bilayer system has been fabricated on X-ray transparent 100-200 nm thin Si{sub 3}N{sub 4} membranes by magnetron sputtering. The microscopic magnetic domain pattern and its behavior during magnetization reversal in the hard and soft magnetic phases have been individually studied by element specific magnetic soft x-ray microscopy at a spatial resolution of better than 25nm. We observe that the domain patterns for soft and hard phases switch coherently throughout the full hysteresis cycle upon applying external magnetic fields. We derived local M(H) curves from the images for Fe and SmCo5 separately and found switching for both hard and soft phases same.

36 MATERIALS SCIENCE↗

Hyperspectral Microscopy of Explosives Particles Using an External Cavity Quantum Cascade Laser

Using infrared hyperspectral imaging, we demonstrate microscopy of small particles of the explosives compounds RDX, tetryl, and PETN with near diffraction-limited performance. The custom microscope apparatus includes an external cavity quantum cascade laser illuminator scanned over its tuning range of 9.13-10.53 µm in four seconds, coupled with a microbolometer focal plane array to record infrared transmission images. We use the hyperspectral microscopy technique to study the infrared absorption spectra of individual explosives particles, and demonstrate sub-nanogram detection limits.

(110.4234) Multispectral & Hyperspectral Imaging↗

Recent advances in nano-scale spatial resolution x-ray microscopy instrumentation at NSLS-II

X-ray microscopy is an invaluable and powerful characterization tool applied in many scientific fields, such as materials science, biology, environmental science, and energy research. In recent years it has been driven by rapid developments of novel technologies and systems resulting in imaging experiments elucidating structural inhomogeneities and chemical reactions at the nanometer scale. To obtain high spatial resolution comprehensive chemical and structural information, an X-ray microscope must be equipped with adequate capabilities and allow for simultaneous acquisition of multiple datasets. In recent years, a number of X-ray microscopes have been designed, constructed, and commissioned at NSLS-II. Here we provide an overview of the microscopy instrumentation development program at NSLS-II and specifically focus on the multilayer Laue lens-based hard X-ray nanoprobe optimized for ~10 nm spatial resolution imaging, its current status, and future upgrades along with recently constructed Kirkpatrick-Baez based scanning microscope designed for ~100 nm spatial resolution experiments.

36 MATERIALS SCIENCE↗

Temperature Dependent Thermal Conductivity of Si/SiC Amorphous Multilayer Films

The cross-plane thermal conductivity of 22 nm period Si/SiC amorphous multilayer films deposited by magnetron sputtering and measured using a differential 3{omega} method was found to decrease from 2.0 W/mK at 300 K to 1.1 W/mK at 80 K. Structural disorder in each of the constituent layers of the amorphous multilayer films was confirmed by high resolution transmission electron microscopy. Estimations of the relative contributions of interface and intrinsic layer thermal resistance based on microscopic phonon transport models indicate that mean free path reductions induced by the structural disorder within the multilayer films are responsible for the observed experimental trends.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sintering behavior of lanthanide-containing glass-ceramic sealants for solid oxide fuel cells

This article reports on the influence of different lanthanides (La, Nd, Gd and Yb) on sintering behavior of alkaline-earth aluminosilicate glass-ceramics sealants for their application in solid oxide fuel cells (SOFC). All the glasses have been prepared by melt-quench technique. The in situ follow up of sintering behavior of glass powders has been done by high temperature - environmental scanning electron microscope (HT-ESEM) and hot-stage microscope (HSM) while the crystalline phase evolution and assemblage has been analyzed by x-ray diffraction (XRD) and scanning electron microscopy (SEM). All the glass compositions exhibit a glass-in-glass phase separation followed by two stage sintering resulting in well sintered glass powder compacts after heat treatment at 850 C for 1 h. Diopside (CaMgSi{sub 2}O{sub 6}) based phases constituted the major crystalline part in glass-ceramics followed by some minor phases. The increase in lanthanide content in glasses suppressed their tendency towards devitrification, thus, resulting in glass-ceramics with high amount of residual glassy phase (50-96 wt.%) which is expected to facilitate their self-healing behavior during SOFC operation. The electrical conductivity of the investigated glass-ceramics varied between (1.19 and 7.33) x 10{sup -7} S cm{sup -1} (750-800 C), and depended on the ionic field strength of lanthanide cations. Further experimentation with respect to the long term thermal and chemical stability of residual glassy phase under SOFC operation conditions along with high temperature viscosity measurements will be required in order to elucidate the potential of these glass-ceramics as self-healing sealants.

30 DIRECT ENERGY CONVERSION↗

Atomic-scale manipulation of polar domain boundaries in monolayer ferroelectric In 2 Se 3

Domain boundaries have been intensively investigated in bulk ferroelectric materials and two-dimensional materials. Many methods such as electrical, mechanical and optical approaches have been utilized to probe and manipulate domain boundaries. So far most research focuses on the initial and final states of domain boundaries before and after manipulation, while the microscopic understanding of the evolution of domain boundaries remains elusive. In this paper, we report controllable manipulation of the domain boundaries in two-dimensional ferroelectric In 2 Se 3 with atomic precision using scanning tunneling microscopy. We show that the movements of the domain boundaries can be driven by the electric field from a scanning tunneling microscope tip and proceed by the collective shifting of atoms at the domain boundaries. Our density functional theory calculations reveal the energy path and evolution of the domain boundary movement. The results provide deep insight into domain boundaries in two-dimensional ferroelectric materials and will inspire inventive applications of these materials.

36 MATERIALS SCIENCE↗

A method to determine the number of nanoparticles in a cluster using conventional optical microscopes

We present a method that uses conventional optical microscopes to determine the number of nanoparticles in a cluster, which is typically not possible using traditional image-based optical methods due to the diffraction limit. The method, called through-focus scanning optical microscopy (TSOM), uses a series of optical images taken at varying focus levels to achieve this. The optical images cannot directly resolve the individual nanoparticles, but contain information related to the number of particles. The TSOM method makes use of this information to determine the number of nanoparticles in a cluster. Initial good agreement between the simulations and the measurements is also presented. The TSOM method can be applied to fluorescent and non-fluorescent as well as metallic and non-metallic nano-scale materials, including soft materials, making it attractive for tag-less, high-speed, optical analysis of nanoparticles down to 45 nm diameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗