Search NASA⌕ Search

SEARCH · Search NASA

Results for “Model Checking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Investigating Various Failure Models on Commercial Silicon Carbide

Structures and components made from ceramic materials are often brittle and can fail by the unstable growth of existing flaws such as voids and cracks. There have been several failure criteria developed for ceramics, in the past and they are broadly categorized based on their dependency on crack geometry. The present work implements eight failure criteria using an open-source software package – srlife, which predicts the lifetime or failure probability of concentrated solar power (CSP) structural components. The present work also checks the viability of building a ceramic CSP receiver, by analyzing the reliability predictions from srlife for a SiC ceramic. The reliability predictions for a biaxial loading problem indicated the Shetty Mixed-Mode criterion gives the most conservative predictions. Whereas, in case of the CSP receiver, the predictions show that the co-planar strain energy criterion gives the most conservative predictions as it is agnostic towards the type of stress, and therefore, is not recommended to be used designing ceramic receivers.

Chaugule, Pawan (ORCID:0000000275706572)↗

Iron Ore Reduction by Hydrogen Using a Laboratory Scale Fluidized Bed Reactor: Kinetic Investigation—Experimental Setup and Method for Determination

The reduction kinetics of hematite iron ore fines to metallic iron by hydrogen using a laboratory fluidized bed reactor were investigated in a temperature range between 873 K and 1073 K, by measuring the weight change of the sample portion during reduction. The fluidization conditions were checked regarding plausibility within the Grace diagram and the measured pressure drop across the material during experiments. The apparent activation energy of the reduction was determined against the degree of reduction and varied along an estimated two-peak curve between 11 and 55 kJ mol{sup −1}. Conventional kinetic analysis for the reduction of FeO to metallic iron, using typical models to describe gas–solid reactions, does not show results with high accuracy. Multistep kinetic analysis, using the Johnson–Mehl–Avrami model, shows that the initial stage of reduction from Fe{sub 2}O{sub 3} to Fe{sub 3}O{sub 4}, and partly to FeO, is controlled by diffusion and chemical reaction, depending on the temperature. Further reduction can be described by a combination of nucleation and chemical reaction, whereby the influence of nucleation increases with an increasing reduction temperature. The results of the kinetical analysis were linked to the shape of the curve from apparent activation energy against the degree of reduction.

36 MATERIALS SCIENCE↗

A unifying identity for the work of cluster formation in heterogeneous and homogeneous nucleation theory

A unifying identity is derived relating the reversible work of cluster formation (W), and its molecular number content (n) and surface work (Φ) components, each ratioed to the corresponding values for a spherical capillary drop of critical size in classical nucleation theory. The result is a relationship that connects these ratios: fW = -2f N + 3f S where f W =W/W* CNT , f N =n/ n* CNT , and f S =Φ/Φ* CNT . Shown to generalize two early thermodynamic relationships of Gibbs, the new result is demonstrated here for Fletcher’s model of heterogeneous nucleation, resulting in a unified treatment of condensation on flat and curved substrates and smooth passage to the homogeneous limit. Additional applications are made to clusters of non-critical as well as critical size, and to a molecular-based extension of classical nucleation theory based on the Kelvin relation. The new identity serves as a consistency check on complicated theoretical expressions and numerical calculations and can be used to guide construction of theory and interpretation of measurements.

54 ENVIRONMENTAL SCIENCES↗

Full Counting Statistics of Charge in Chaotic Many-Body Quantum Systems

We investigate the full counting statistics of charge transport in U(1)-symmetric random unitary circuits. We consider an initial mixed state prepared with a chemical potential imbalance between the left and right halves of the system and study the fluctuations of the charge transferred across the central bond in typical circuits. Using an effective replica statistical mechanics model and a mapping onto an emergent classical stochastic process valid at large on-site Hilbert space dimension, we show that charge transfer fluctuations approach those of the symmetric exclusion process at long times, with subleading t –1/2 quantum corrections. Here, we discuss our results in the context of fluctuating hydrodynamics and macroscopic fluctuation theory of classical nonequilibrium systems and check our predictions against direct matrix-product state calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation and Verification of the Correct Operation of the Spectro RS23 UV-VIS Spectrometer used in ANC122 and NF-ANC122

In September of 2011, the old qualified Bausch and Laum Spec 100 UV-Vis instrument used in the ANC122 and NF-ANC122 procedures failed its monthly calibration check. Attempts to get the system to pass by cleaning flow cells, replacing the light bulb and realigning the light path failed to get sustained reproducible results from the system. In October the decision to take it out of service was made as the system was 40+ years in age. To replace the system, a previously purchased Labomed Inc.’s spectrometer (model Spectro 23RS; Serial #: 23RS-004253) was retrieved from storage. This report shows that the Labomed Inc. system is performing as required and meeting all QC requirements listed in ANC122 and NF-ANC122. Upon submitting this report to records, the system will be considered qualified to report results to customers of C-AAC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-Supervised Anomaly Detection via Neural Autoregressive Flows with Active Learning

Many self-supervised methods have been proposed with the target of image anomaly detection. These methods often rely on the paradigm of data augmentation with predefined transformations such as flipping, cropping, and rotations. However, it is not straightforward to apply these techniques for non-image data, such as time series or tabular data, while the performance of the existing deep approaches has been under our expectation on tasks beyond images. In this work, we propose a novel active learning (AL) scheme that relied on neural autoregressive flows (NAF) for self-supervised anomaly detection, specifically on small-scale data. Unlike other generative models such as GANs or VAEs, flow-based models allow to explicitly learn the probability density and thus can assign accurate likelihoods to normal data which makes it usable to detect anomalies. The proposed NAF-AL method is achieved by efficiently generating random samples from latent space and transforming them into feature space along with likelihoods via invertible mapping. The samples with lower likelihoods are selected and further checked by outlier detection using Mahalanobis distance. The augmented samples incorporating with normal samples are used for training a better detector so as to approach decision boundaries. Compared with random transformations, NAF-AL can be interpreted as a likelihood-oriented data augmentation that is more efficient and robust. Extensive experiments show that our approach outperforms existing baselines on multiple time series and tabular datasets, and a real-world application in advanced manufacturing, with significant improvement on anomaly detection accuracy and robustness over the state-of-the-art.

Zhang, Jiaxin↗

Invited Review Article: Gas puff imaging diagnostics of edge plasma turbulence in magnetic fusion devices

Gas puff imaging (GPI) is a diagnostic of plasma turbulence which uses a puff of neutral gas at the plasma edge to increase the local visible light emission for improved space-time resolution of plasma fluctuations. This paper reviews gas puff imaging diagnostics of edge plasma turbulence in magnetic fusion research, with a focus on the instrumentation, diagnostic cross-checks, and interpretation issues. The gas puff imaging hardware, optics, and detectors are described for about 10 GPI systems implemented over the past similar to 15 years. Comparison of GPI results with other edge turbulence diagnostic results is described, and many common features are observed. Here, several issues in the interpretation of GPI measurements are discussed, and potential improvements in hardware and modeling are suggested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE VERTICAL MOTIONS OF MONO-ABUNDANCE SUB-POPULATIONS IN THE MILKY WAY DISK

We present the vertical kinematics of stars in the Milky Way's stellar disk inferred from Sloan Digital Sky Survey/Sloan Extension for Galactic Understanding and Exploration (SDSS/SEGUE) G-dwarf data, deriving the vertical velocity dispersion, {sigma}{sub z}, as a function of vertical height |z| and Galactocentric radius R for a set of 'mono-abundance' sub-populations of stars with very similar elemental abundances [{alpha}/Fe] and [Fe/H]. We find that all mono-abundance components exhibit nearly isothermal kinematics in |z|, and a slow outward decrease of the vertical velocity dispersion: {sigma}{sub z}(z, R | [{alpha}/Fe], [Fe/H]) Almost-Equal-To {sigma}{sub z}([{alpha}/Fe], [Fe/H]) Multiplication-Sign exp (- (R - R{sub 0})/7 kpc). The characteristic velocity dispersions of these components vary from {approx}15 km s{sup -1} for chemically young, metal-rich stars with solar [{alpha}/Fe], to {approx}> 50 km s{sup -1} for metal-poor stars that are strongly [{alpha}/Fe]-enhanced, and hence presumably very old. The mean {sigma}{sub z} gradient (d{sigma}{sub z}/dz) away from the mid-plane is only 0.3 {+-} 0.2 km s{sup -1} kpc{sup -1}. This kinematic simplicity of the mono-abundance components mirrors their geometric simplicity; we have recently found their density distribution to be simple exponentials in both the z- and R-directions. We find a continuum of vertical kinetic temperatures ({proportional_to}{sigma}{sup 2}{sub z}) as a function of ([{alpha}/Fe], [Fe/H]), which contribute to the total stellar surface-mass density approximately as {Sigma}{sub R{sub 0}}({sigma}{sup 2}{sub z}){proportional_to} exp(-{sigma}{sup 2}{sub z}). This and the existence of isothermal mono-abundance populations with intermediate dispersions (30-40 km s{sup -1}) reject the notion of a thin-thick-disk dichotomy. This continuum of disk components, ranging from old, 'hot', and centrally concentrated ones to younger, cooler, and radially extended ones, argues against models where the thicker disk portions arise from massive satellite infall or heating; scenarios where either the oldest disk portion was born hot, or where internal evolution plays a major role, seem the most viable. In addition, the wide range of {sigma}{sub z}([{alpha}/Fe], [Fe/H]) combined with a constant {sigma}{sub z}(z) for each abundance bin provides an independent check on the precision of the SEGUE-derived abundances: {delta}{sub [{alpha}/Fe]} Almost-Equal-To 0.07 dex and {delta}{sub [Fe/H]} Almost-Equal-To 0.15 dex. The slow radial decline of the vertical dispersion presumably reflects the decrease in disk surface-mass density. This measurement constitutes a first step toward a purely dynamical estimate of the mass profile of the stellar and gaseous disk in our Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron beam quality control using an amorphous silicon EPID

An amorphous silicon EPID has been investigated to determine whether it is capable of quality control constancy measurements for linear accelerator electron beams. The EPID grayscale response was found to be extremely linear with dose over a wide dose range and, more specifically, for exposures of 95-100 MU. Small discrepancies of up to 0.8% in linearity were found at 6 MeV (8-15 MeV showed better agreement). The shape of the beam profile was found to be significantly altered by scatter in air over the approximately 60 cm gap between the end of the applicator and the EPID. Nevertheless, relative changes in EPID-measured profile flatness and symmetry were linearly related to changes in these parameters at 95 cm focus to surface distance (FSD) measured using a 2D diode array. Similar results were obtained at 90 deg. and 270 deg. gantry angles. Six months of daily images were acquired and analyzed to determine whether the device is suitable as a constancy checker. EPID output measurements agreed well with daily ion chamber measurements, with a 0.8% standard deviation in the difference between the two measurement sets. When compared to weekly parallel plate chamber measurements, this figure dropped to 0.5%. A Monte Carlo (MC) model of the EPID was created and demonstrated excellent agreement between MC-calculated profiles in water and the EPID at 95 and 157 cm FSD. Good agreement was also found with measured EPID profiles, demonstrating that the EPID provides an accurate measurement of electron profiles. The EPID was thus shown to be an effective method for performing electron beam daily constancy checks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation and Verification of the Correct Operation of the Thermo Fisher Scientific’s Genesys 10S spectrometer used in ANC122 and NF-ANC122

In December of 2015, the old qualified Prim UV-Vis instrument used in the ANC122 and NFANC122 procedures failed its monthly calibration check. Attempts to get the system to pass by cleaning flow cells, replacing the light bulb and realigning the light path failed to get sustained reproducible results from the system. As it could no longer pass QA/QC requirements the decision to take it out of service was made. To replace the system, a previously purchased Thermo Fisher Scientific UV-VIS spectrometer (model Genesys 10S; Serial #: 2L5R059137) was retrieved from storage. This report shows that the system is performing as required and meeting all QC requirements listed in ANC122 and NF-ANC122

47 OTHER INSTRUMENTATION↗

Beam optics and the pp2pp experiment at RHIC

The newly installed forward detector system at the STAR experiment at RHIC measures small angle elastic and inelastic scattering of polarized protons on polarized protons. The detector system makes use of a pair of Roman Pot (RP) detectors, instrumented with silicon detectors, and located on either side of the STAR intersection region downstream of the DX and D0 dipoles and quadrupole triplets. The parallel to point optics is designed so that scattering angles are determined from position measurements at the RP's with small error. The RP setup allows measurement of position and angle for a subset of the scattered protons. With this position/angle correlations at the RP's can be compared with optics model predictions to get a measure of the accuracy of the quadrupole triplet current settings. The current in each quadrupole in the triplets is comprised of sums and differences of up to six power supplies and an overall 1% error in the triplet field strengths results in a 4% error in four-momentum transfer squared. This technique is also useful to check the polarity of the skew elements located in each quadrupole triplet. Results of the analysis will be presented.

43 PARTICLE ACCELERATORS↗

Unitarity check in gravitational Higgs mechanism

The effective field theory of massive gravity has long been formulated in a generally covariant way [N. Arkani-Hamed, H. Georgi, and M. D. Schwartz, Ann. Phys. (N.Y.) 305, 96 (2003).]. Using this formalism, it has been found recently that there exists a class of massive nonlinear theories that are free of the Boulware-Deser ghosts, at least in the decoupling limit [C. de Rham and G. Gabadadze, Phys. Rev. D 82, 044020 (2010).]. In this work we study other recently proposed models that go under the name of 'gravitational Higgs theories' [A. H. Chamseddine and V. Mukhanov, J. High Energy Phys. 08 (2010) 011.]. We show that these models, although seemingly different from the effective field theories of massive gravity, are in fact equivalent to them. Furthermore, based on the results obtained in the effective field theory approach, we conclude that the gravitational Higgs theories need the same adjustment of the Lagrangian to avoid the ghosts. We also show the equivalence between the noncovariant mode decomposition used in the Higgs theories, and the covariant Stueckelberg parametrization adopted in the effective field theories, thus proving that the presence or absence of the ghost is independent of the parametrization used in either theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal Wear Sensing System: Proof of the Concept

A technique for wear sensing using a sacrificial layer with specific material properties has been developed successfully. This is achieved by recording the temperature evolution underneath the sacrificial organic layer during sliding tests, and by correlating the recorded temperature with a wear depth. Finite element modeling was used to calculate the contact temperature which spreads through the sacrificial layer under different sliding test conditions. Numerical simulation was used to determine the optimal parameters for the best correlation between temperature and wear depth. These parameters were used to select the appropriate sacrificial layer for wear sensing. Thus, an epoxy layer was implemented and experimental measurements were carried out to check the correlation between the measured temperature underneath the epoxy layer and wear depth. It was found that a low thermal conductivity of the sacrificial layer of less than 1 W/m K and a relative high thermal conductivity of the substrate, namely more than 4 W/m K are the optimal parameters for our thermal wear sensing system. The thickness of the sacrificial layer is also a crucial parameter and has to be taken into account when designing such a sensing system.

36 MATERIALS SCIENCE↗

Fragile aspects of topological transition in lossy and parity-time symmetric quantum walks

Quantum walks often provide telling insights about the structure of the system on which they are performed. Here, in PT-symmetric and lossy dimer lattices, the topological properties of the band structure manifest themselves in the quantization of the mean displacement of such a walker. We investigate the fragile aspects of a topological transition in these two dimer models. We find that the transition is sensitive to the initial state of the walker on the Bloch sphere, and the resultant mean displacement has a robust topological component and a quasiclassical component. In PT symmetric dimer lattices, we also show that the transition is smeared by nonlinear effects that become important in the PT-symmetry broken region. By carrying out consistency checks via analytical calculations, tight-binding results, and beam-propagation-method simulations, we show that our predictions are easily testable in today’s experimental systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Circuit complexity near critical points

Here, we consider the Bose–Hubbard model in two and three spatial dimensions and numerically compute the quantum circuit complexity of the ground state in the Mott insulator and superfluid phases using a mean field approximation with additional quadratic fluctuations. After mapping to a qubit system, the result is given by the complexity associated with a Bogoliubov transformation applied to the reference state taken to be the mean field ground state. In particular, the complexity has peaks at the O(2) critical points where the system can be described by a relativistic quantum field theory. Given that we use a Gaussian approximation, near criticality the numerical results agree with a free field theory calculation. To go beyond the Gaussian approximation we use general scaling arguments that imply that, as we approach the critical point t → t c , there is a non-analytic behavior in the complexity c 2 (t) of the form |c 2 (t) – c 2 (t c )| ~ |t – t c | νd , up to possible logarithmic corrections. Here d is the number of spatial dimensions and ν is the usual critical exponent for the correlation length ξ ~ |t – t c | –ν . As a check, for d = 2 this agrees with the numerical computation if we use the Gaussian critical exponent $v=\frac{1}{2}$. Finally, using AdS/CFT methods, we study higher dimensional examples and confirm this scaling argument with non-Gaussian exponent ν for strongly interacting theories that have a gravity dual.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collectivity of neutron-rich palladium isotopes and the valence proton symmetry

Absolute transition probabilities for the first 2{sup +} states in {sup 110,114}Pd were measured using the recoil distance Doppler shift technique following projectile Coulomb excitation at intermediate beam energy. This technique was applied for the first time to projectiles produced in a primary fragmentation reaction, which get Coulomb excited in a secondary reaction. The {sup 110}Pd data was used to check the novel experimental technique as well as the data analysis procedure, which is based on the examination of {gamma}-ray line shapes. Whereas the measured B(E2) value for {sup 110}Pd agrees very well with the literature, the value obtained for {sup 114}Pd differs considerably. The new experimental data are compared to calculations in the framework of the Interacting Boson Model. The data are also used to test the novel concept of valence proton symmetry, which allows for extrapolation of nuclear properties to very neutron-rich nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-G-201-15: Nomogram as an Efficient Dosimetric Verification Tool in HDR Prostate Brachytherapy

Purpose: Nomogram as a simple QA tool for HDR prostate brachytherapy treatment planning has been developed and validated clinically. Reproducibility including patient-to-patient and physician-to-physician variability was assessed. Methods: The study was performed on HDR prostate implants from physician A (n=34) and B (n=15) using different implant techniques and planning methodologies. A nomogram was implemented as an independent QA of computer-based treatment planning before plan execution. Normalized implant strength (total air kerma strength Sk*t in cGy cm{sup 2} divided by prescribed dose in cGy) was plotted as a function of PTV volume and total V100. A quadratic equation was used to fit the data with R{sup 2} denoting the model predictive power. Results: All plans showed good target coverage while OARs met the dose constraint guidelines. Vastly different implant and planning styles were reflected on conformity index (entire dose matrix V100/PTV volume, physician A implants: 1.27±0.14, physician B: 1.47±0.17) and PTV V150/PTV volume ratio (physician A: 0.34±0.09, physician B: 0.24±0.07). The quadratic model provided a better fit for the curved relationship between normalized implant strength and total V100 (or PTV volume) than a simple linear function. Unlike the normalized implant strength versus PTV volume nomogram which differed between physicians, a unique quadratic model based nomogram (Sk*t)/D=−0.0008V2+0.0542V+1.1185 (R{sup 2}=0.9977) described the dependence of normalized implant strength on total V100 over all the patients from both physicians despite two different implant and planning philosophies. Normalized implant strength - total V100 model also generated less deviant points distorting the smoothed ones with a significantly higher correlation. Conclusion: A simple and universal, excel-based nomogram was created as an independent calculation tool for HDR prostate brachytherapy. Unlike similar attempts, our nomogram is insensitive to implant style and does not rely on reproducing dose calculations using TG-43 formalism, thus making it a truly independent check.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-07: Real-Time EPID-Based Detection Metric For VMAT Delivery Errors

Purpose: To create and test an accurate EPID-frame-based VMAT QA metric to detect gross dose errors in real-time and to provide information about the source of error. Methods: A Swiss cheese model was created for an EPID-based real-time QA process. The system compares a treatmentplan- based reference set of EPID images with images acquired over each 2° gantry angle interval. The metric utilizes a sequence of independent consecutively executed error detection Methods: a masking technique that verifies infield radiation delivery and ensures no out-of-field radiation; output normalization checks at two different stages; global image alignment to quantify rotation, scaling and translation; standard gamma evaluation (3%, 3 mm) and pixel intensity deviation checks including and excluding high dose gradient regions. Tolerances for each test were determined. For algorithm testing, twelve different types of errors were selected to modify the original plan. Corresponding predictions for each test case were generated, which included measurement-based noise. Each test case was run multiple times (with different noise per run) to assess the ability to detect introduced errors. Results: Averaged over five test runs, 99.1% of all plan variations that resulted in patient dose errors were detected within 2° and 100% within 4° (∼1% of patient dose delivery). Including cases that led to slightly modified but clinically equivalent plans, 91.5% were detected by the system within 2°. Based on the type of method that detected the error, determination of error sources was achieved. Conclusion: An EPID-based during-treatment error detection system for VMAT deliveries was successfully designed and tested. The system utilizes a sequence of methods to identify and prevent gross treatment delivery errors. The system was inspected for robustness with realistic noise variations, demonstrating that it has the potential to detect a large majority of errors in real-time and indicate the error source. J. V. Siebers receives funding support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗