Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating Experience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Contamination control and assay results for the Majorana Demonstrator ultra clean components

The Majorana Demonstrator is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The Demonstrator has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. In conclusion, this article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.

36 MATERIALS SCIENCE↗

Verification of particle simulation of radio frequency waves in fusion plasmas

Radio frequency (RF) waves can offer heating, current and flow drive, as well as instability control for steady state operations of fusion experiments. A particle simulation model has been designed in this work to provide a first-principles tool for studying the RF nonlinear interactions with plasmas. In this model, ions are considered as fully kinetic particles using the Vlasov equation and electrons are treated as guiding centers using the drift kinetic equation. This model has been implemented in a global gyrokinetic toroidal code using real electron-to-ion mass ratio. To confirm the model, linear simulations of ion plasma oscillation, ion Bernstein wave, and lower hybrid wave are carried out in cylindrical geometry and found to agree well with analytic predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutrinoless double beta decay in chiral effective field theory: lepton number violation at dimension seven

Here, we analyze neutrinoless double beta decay (0νββ) within the framework of the Standard Model Effective Field Theory. Apart from the dimension-five Weinberg operator, the first contributions appear at dimension seven. We classify the operators and evolve them to the electroweak scale, where we match them to effective dimension-six, -seven, and -nine operators. In the next step, after renormalization group evolution to the QCD scale, we construct the chiral Lagrangian arising from these operators. We then develop a power-counting scheme and derive the two-nucleon 0νββ currents up to leading order in the power counting for each lepton-number-violating operator. We argue that the leading-order contribution to the decay rate depends on a relatively small number of nuclear matrix elements. We test our power counting by comparing nuclear matrix elements obtained by various methods and by different groups. We find that the power counting works well for nuclear matrix elements calculated from a specific method, while, as in the case of light Majorana neutrino exchange, the overall magnitude of the matrix elements can differ by factors of two to three between methods. We also calculate the constraints that can be set on dimension-seven lepton-number-violating operators from 0νββ experiments and study the interplay between dimension-five and -seven operators, discussing how dimension-seven contributions affect the interpretation of 0νββ in terms of the effective Majorana mass m ββ .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Experimental Investigation of Students? Learning Effects When Using a Simplified Nuclear Simulator

This study focuses on investigating students' learning effects and performance trends over a certain period using the Rancor Microworld Simulator. Specifically, it aims to determine the training required to collect HRA data from non-experts (i.e., students) using Rancor Microworld and the differences in human performance measures between students and professional operators. A longitudinal experiment is conducted with sixteen undergraduate students, using four Rancor Microworld scenarios in each of the four experiment trials. The study considers four human performance measurements workload, situation awareness, time, and error. Finally, the trend of students' performance is compared with operator data collected from the previous experiment. Overall, this research complements previous studies by providing insights into how much training is required to collect HRA data from non-experts and the differences in human performance measures between students and professional operators.

99 GENERAL AND MISCELLANEOUS↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Flattop Operations at NCERC

The Flattop critical assembly was built and operated from 1958 through 2004 at the Pajarito Site (Technical Area-18), home to the Los Alamos Critical Experiments Facility. Flattop was disassembled in 2005 and refurbished over the course of 3 years. In 2008, Flattop was installed in the National Criticality Experiments Research Center (NCERC) located in the Device Assembly Facility at the Nevada National Security Site. Startup of Flattop with a uranium core occurred in 2011. This paper details the first 10 years of Flattop operations at NCERC (2011–present).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic System Simulation of the KRUSTY Experiment

The proposed KRUSTY experiment is a demonstration of a reactor operating at power. The planned experimental configuration includes a highly enriched uranium (HEU) reflected core, cooled by multiple heat pipes leading to Stirling engines for primary heat rejection. Operating power is expected to be approximately four (4) to five (5) kilowatts with a core temperature above 1,000 K. No data is available on any historical reactor employing HEU metal that operated over the temperature range required for the KRUSTY experiment. Further, no reactor has operated with heat pipes as the primary cooling mechanism. Historic power reactors have employed either natural or forced convection so data on their operation is not directly applicable to the KRUSTY experiment. The primary purpose of the system model once developed and refined by data from these component experiments, will be used to plan the KRUSTY experiment. This planning will include expected behavior of the reactor from start-up, through various transient conditions where cooling begins to become present and effective, and finally establishment of steady-state. In addition, the model can provide indicators of anticipated off-normal events and appropriate operator response to those conditions. This information can be used to develop specific experiment operating procedures and aids to guide the operators in conduct of the experiment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

1994 SSRL Activity Report

SSRL, a division of the Stanford Linear Accelerator Center, is a national user facility which provides synchrotron radiation, a name given to x-rays or light produced by electrons circulating in a storage ring at nearly the speed of light. The synchrotron radiation is produced by the 3.3 GeV storage ring, SPEAR. SPEAR is a fully dedicated synchrotron radiation facility which has been operating for user experiments 6 to 7 months per year. 1994, the third year of operation of SSRL as a fully dedicated, low-emittance, independent user facility was superb. The facility ran extremely well, delivering 89% of the scheduled user beam to 25 experimental stations during 6.5 months of user running. Over 600 users came from 167 institutions to participate in 343 experiments. Users from private industry were involved in 31% of these experiments. The SPEAR accelerator ran very well with no major component failures and an unscheduled down time of only 2.9%. In addition to this increased reliability, there was a significant improvement in the stability of the beam. The enhancements to the SPEAR orbit as part of a concerted three-year program were particularly noticeable to users. the standard deviation of beam movement (both planes) in the last part of the run was 80 microns, major progress toward the ultimate goal of 50-micron stability. This was a significant improvement from the previous year when the movement was 400 microns in the horizontal and 200 microns in the vertical. A new accelerator Personal Protection System (PPS), built with full redundancy and providing protection from both radiation exposure and electrical hazards, was installed in 1994.

43 PARTICLE ACCELERATORS↗

Financial Analysis of the High Flow Experiment conducted at the Glen Canyon Dam during Water Year 2023

The Glen Canyon Dam (GCD) is a Colorado River Storage Project (CRSP) power resource that is a component of the Salt Lake City Area Integrated Projects (SLCA/IP). The 2016 record of decision (ROD) for the GCD long-term experimental and management plan (LTEMP) final Environmental Impact Statement (EIS) specified criteria for GCD monthly water releases, daily and hourly operating limits, and experimental releases. This report examines the financial implications of the high flow experiment (HFE) conducted at GCD during the spring of Water Year (WY) 2023 as required by the LTEMP HFE Protocol. This report is part of a series of reports that describe the financial costs of LTEMP experimental releases since the 2016 ROD was adopted in January 2017. Previous reports analyzed the impact of several past HFEs and Bug Flow Experiments. This report focuses on the HFE conducted in April 2023. For this experimental release, financial costs of approximately $1.33 million were incurred because the HFE required sustained water releases exceeding the power plant’s maximum turbine flow rate. In addition, during the experiment, operators were not allowed to shape GCD power production, either to follow Firm Electric Service (FES) customer day-ahead energy deliveries or to respond to market prices. This study identifies the main factors contributing to the HFE costs and examines the interdependencies among these factors. It applies an integrated set of tools to estimate Western Area Power Administration (WAPA) financial impacts by simulating GCD under two types of cases; namely, (1) a “With Experiment” case that mimics the operations that actually occurred and (2) a “Without Experiment” case that simulates operations under the assumption that the HFE did not occur. The “With Experiment” case mimics operations during the HFE and the entire month the HFE occurred. It complies with LTEMP hourly and daily operating criteria. The “Without Experiment” case assumes that the HFE did not occur. The monthly water release volume is assumed to be identical under both cases. The Colorado River Storage Project Python-based model (CRiSPPy) model was the main modeling tool used to simulate the dispatch of the GCD hydropower plant and associated water releases from Lake Powell. In the modeling process, the research team used extensive data sets and historical information on SLCA/IP power plant characteristics, hydrologic conditions, and WAPA’s power purchases and sales prices. In addition to estimating the financial impact of the HFE, the team used the CRiSPPy model to gain insights into the interplay among ROD operating criteria, exceptions made to criteria to accommodate the HFE, and WAPA operating practices.

13 HYDRO ENERGY↗

Design of a High-Assay Low-Enriched Uranium Tri-Structural Isotropic Critical Experiment for Advanced Reactor Validation

High-assay low-enriched uranium (HALEU) fuel is a key component of many small modular reactor designs. Critical experiments are an important way to understand the neutronic performance of systems by obtaining nuclear data validations through measurements. Data reduce uncertainty and risk by showing that systems respond as predicted to changes such as temperature, subsequently advancing the overall technology readiness level of the materials within. Numerous critical experiments have been performed at the National Criticality Experiments Research Center (NCERC) operated by Los Alamos National Laboratory at the Nevada National Security Site since it became operational in 2011. However, the first experiment with HALEU fuel did not occur until 2024. Through extensive engineering, the experiment described in this paper was successfully designed and executed for the Comet vertical lift assembly at NCERC to perform measurements with HALEU tri-structural isotropic fuel that will assist in validation of nuclear data and computational modeling of small modular reactors for years to come.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparative Analysis of Heat Exchangers for High Temperature High Pressure Helium Component Testing

Helium gas loops have been designed and built to gain a better understanding of the gas thermohydraulic phenomena that take place in a helium system. Some of these loops are used for validation and testing of components for high temperature gas-cooled reactors (HTGRs). However, most of them operate at lower pressure and temperature than an HTGR. While these loops can provide valuable information about gas-cooled reactor components, the operating envelope of the experiment is constrained by the maximum operating conditions of the helium loop. In response to the lack of an experimental facility that can provide the infrastructure needed to validate and test components at nominal pressures and temperatures of HTGRS, the HElium Component Testing Out-of-pile Research (HECTOR) facility was designed at Idaho National Laboratory with the assistance of University of Idaho and Walsh Engineering. With the capability to test at temperatures up to 800°C and pressures of 8MPa, HECTOR serves as a critical tool for the advancement of HTGR technology. The facility's primary role is to provide a controlled, high-fidelity environment for the assessment of component resilience and efficiency under nominal HTGR conditions. In the quest to enhance the efficiency and performance of HECTOR, a comparative analysis of three distinct types of heat exchangers—shell and tube, offset strip fin, and printed-circuit—was conducted, focusing primarily on two critical metrics: the required surface area and pressure drop characteristics. The shell and tube heat exchanger, renowned for its robust design and widespread industrial application, was evaluated against the offset strip fin and the cuttingedge printed-circuit heat exchangers, both of which are lauded for their compactness and thermal effectiveness. This comparative study aims to provide detailed insights into the thermal management capabilities of each heat exchanger type under the conditions inherent to HECTOR, thereby facilitating an informed selection for systems demanding high operational integrity and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status of the CMS Detector Control System

The Compact Muon Solenoid (CMS) is a CERN multi-purpose experiment that exploits the physics of the Large Hadron Collider (LHC). The Detector Control System (DCS) is responsible for ensuring the safe, correct and efficient operation of the experiment, and has contributed to the recording of high quality physics data. The DCS is programmed to automatically react to the LHC operational mode. CMS sub-detectors bias voltages are set depending on the machine mode and particle beam conditions. An operator provided with a small set of screens supervises the system status summarized from the approximately 6M monitored parameters. Using the experience of nearly two years of operation with beam the DCS automation software has been enhanced to increase the system efficiency by minimizing the time required by sub-detectors to prepare for physics data taking. From the infrastructure point of view the DCS will be subject to extensive modifications in 2012. The current rack mounted control PCs will be replaced by a redundant pair of DELL Blade systems. These blade servers are a high-density modular solution that incorporates servers and networking into a single chassis that provides shared power, cooling and management. This infrastructure modification associated with the migration to blade servers will challenge the DCS software and hardware factorization capabilities. The on-going studies for this migration together with the latest modifications are discussed in the paper.

Bauer, Gerry↗

Insights into determining pore size properties of ultrafiltration membranes

The selectivity of porous membranes is often characterized using solute rejection tests, where membranes are challenged with dilute aqueous solutions of neutral solutes at operating conditions that minimize concentration polarization and fouling. In single solute tests, a membrane is challenged with one molecular weight (MW) solute at a time from low to high MW. Since single solute methods are time-intensive, mixed solute tests have become more common, where a mixture of several MW solutes challenges a membrane at once. However, the presence of large solutes in a mixture increases the rejection of smaller solutes. Furthermore, there are no universally accepted operating conditions or standard methods used by membrane manufacturers or researchers for the experiments, leading to difficulty in pore size and pore characteristic comparisons. In this paper, commercial ultrafiltration membranes were challenged with single and mixed solute polyethylene glycol (PEG) and dextran aqueous solutions. First, rejection values determined using total organic carbon (TOC) and high-performance liquid chromatography (HPLC) from single solute filtration experiments are compared. Differences in rejection curves obtained by the two techniques are attributed to solute polydispersity. Mixed solute filtration experiments with binary mixtures of solutes showcased co-solute interactions, which increase with both the size and weight percent of large solute in the mixture. Mixed solute filtration experiments at varying operating conditions (i.e., stir speed and flux) were conducted to determine operating conditions that mitigate co-solute interactions. Stir speed had a minimal effect on co-solute interactions. In contrast, low flux conditions can help minimize co-solute interactions, leading to pore size distributions that closely resemble results observed in single solute filtration using narrowly dispersed solutes. Additionally, at low flux conditions, the predicted membrane pore size distributions utilizing mixed solute experiments with PEG and dextran were similar.

36 MATERIALS SCIENCE↗

Progress in preparing scenarios for operation of the International Thermonuclear Experimental Reactor

The development of operating scenarios is one of the key issues in the research for ITER which aims to achieve a fusion gain (Q) of ∼10, while producing 500 MW of fusion power for ≥300 s. The ITER Research plan proposes a success oriented schedule starting in hydrogen and helium, to be followed by a nuclear operation phase with a rapid development towards Q ∼ 10 in deuterium/tritium. The Integrated Operation Scenarios Topical Group of the International Tokamak Physics Activity initiates joint activities among worldwide institutions and experiments to prepare ITER operation. Plasma formation studies report robust plasma breakdown in devices with metal walls over a wide range of conditions, while other experiments use an inclined EC launch angle at plasma formation to mimic the conditions in ITER. Simulations of the plasma burn-through predict that at least 4 MW of Electron Cyclotron heating (EC) assist would be required in ITER. For H-modes at q{sub 95} ∼ 3, many experiments have demonstrated operation with scaled parameters for the ITER baseline scenario at n{sub e}/n{sub GW} ∼ 0.85. Most experiments, however, obtain stable discharges at H{sub 98(y,2)} ∼ 1.0 only for β{sub N} = 2.0–2.2. For the rampup in ITER, early X-point formation is recommended, allowing auxiliary heating to reduce the flux consumption. A range of plasma inductance (l{sub i}(3)) can be obtained from 0.65 to 1.0, with the lowest values obtained in H-mode operation. For the rampdown, the plasma should stay diverted maintaining H-mode together with a reduction of the elongation from 1.85 to 1.4. Simulations show that the proposed rampup and rampdown schemes developed since 2007 are compatible with the present ITER design for the poloidal field coils. At 13–15 MA and densities down to n{sub e}/n{sub GW} ∼ 0.5, long pulse operation (>1000 s) in ITER is possible at Q ∼ 5, useful to provide neutron fluence for Test Blanket Module assessments. ITER scenario preparation in hydrogen and helium requires high input power (>50 MW). H-mode operation in helium may be possible at input powers above 35 MW at a toroidal field of 2.65 T, for studying H-modes and ELM mitigation. In hydrogen, H-mode operation is expected to be marginal, even at 2.65 T with 60 MW of input power. Simulation code benchmark studies using hybrid and steady state scenario parameters have proved to be a very challenging and lengthy task of testing suites of codes, consisting of tens of sophisticated modules. Nevertheless, the general basis of the modelling appears sound, with substantial consistency among codes developed by different groups. For a hybrid scenario at 12 MA, the code simulations give a range for Q = 6.5–8.3, using 30 MW neutral beam injection and 20 MW ICRH. For non-inductive operation at 7–9 MA, the simulation results show more variation. At high edge pedestal pressure (T{sub ped} ∼ 7 keV), the codes predict Q = 3.3–3.8 using 33 MW NB, 20 MW EC, and 20 MW ion cyclotron to demonstrate the feasibility of steady-state operation with the day-1 heating systems in ITER. Simulations using a lower edge pedestal temperature (∼3 keV) but improved core confinement obtain Q = 5–6.5, when ECCD is concentrated at mid-radius and ∼20 MW off-axis current drive (ECCD or LHCD) is added. Several issues remain to be studied, including plasmas with dominant electron heating, mitigation of transient heat loads integrated in scenario demonstrations and (burn) control simulations in ITER scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of a streaming readout solution for Jefferson Lab experiments

Jefferson Lab (JLab) operates the CEBAF accelerator that provides a high energy (up to 12 GeV) and high current (up to 150 µA) polarized electron beam for fixed target experiments. JLab's mission is to provide substantial progress in understanding the Quantum Chromo Dynamics (QCD), the current theory of the spectrum and the dynamics of hadronic matter. Given the broad scientific program a general-purpose detector, CLAS12, has been designed and constructed. Such a detector requires a sophisticated trigger and current experiments use an on-line FPGA-based system that relies upon custom firmware and electronics both of which are difficult reconfigure from one experiment to the next. To overcome these challenges transitioning to a streaming readout has been proposed since it would allow a more flexible, easier to debug, software trigger to be developed. To facilitate this JLab is gaining experience with streaming readout systems and is actively working to design and test a streaming data acquisition architecture. Significant work has already been done to make existing front-end electronics compatible with operation in streaming mode. Software-wise, much work remains to be done but an existing framework, TriDAS, which was developed for underwater neutrino telescopes can, in principle, be used with the existing JLab hardware. A test stand is already in place in the INDRA DAQ development lab at JLab. This paper will present the development of this TriDAS based test system and it?s operation in-beam using parts of the CLAS12 detector to evaluate streaming readout for a large general purpose detector.

Battaglieri, Marco↗

Projected WIMP sensitivity of the LUX-ZEPLIN dark matter experiment

LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7 tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector. For a 1000 live day run using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$ cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$ discovery potential is projected reaching cross sections below the existing and projected exclusion limits of similar experiments that are currently operating. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7 \times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Projected WIMP Sensitivity of the LUX-ZEPLIN (LZ) Dark Matter Experiment

LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7 tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector. For a 1000 live day run using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$ cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$ discovery potential is projected reaching cross sections below the existing and projected exclusion limits of similar experiments that are currently operating. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7 \times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP is expected. With construction well underway, LZ is on track for underground installation at SURF in 2019 and will start collecting data in 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗