Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERMANENT MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

LandRAY PTO Testing Utilizing the NREL NWTC 5MW Dynamometer

The overarching project objective is to demonstrate the feasibility of using an innovative PowerTake-Off (PTO) Module in Columbia Power's utility-scale wave energy converter (WEC). The PTO Module uniquely combines a large-diameter, direct-drive, rotary permanent magnet generator; a patent-pending rail-bearing system; and a corrosion-resistant fiber-reinforced-plastic structure

16 TIDAL AND WAVE POWER↗

Two design of the S4.BEN01 magnet for the CBETA splitter/merger

The splitter/merger section of the CBETA project [1] consists of 4 beam lines as shown in Fig. 1. Two of the functions of the splitter’s/merger’s lines is to match the beam parameters at the exit of the Energy Recovery Linac (ERL) to the beam parameters at the entrance of the Fixed Field Alternating Gradient (FFAG) arc, and also place the reference particles of the beam bunches at the entrance of the FFAG arc on specified trajectories according to their energies. In this technical note we are presenting results from the 2D and 3D electromagnetic analysis of the S4.BEN01 magnet which is one of the dipole magnets of the 150 MeV line of the splitter/merger. In particular we present results from two designs of the S4.BEN01 magnet, one based on iron dominated current-excited magnet, and the other design based on Halbach-type permanent magnet. An evaluation of the two designs will be given in the section under “conclusion”.

43 PARTICLE ACCELERATORS↗

Transverse forces in the CBETA v6/v6.5 magnets

These 2D transverse force calculations were done for the following Halbach magnet types in the CBETA design as it currently stands (an implementation of the April 10, 2017 lattice). These magnets are made out of two longitudinally-­stacked layers of permanent magnet blocks.

43 PARTICLE ACCELERATORS↗

Steps to achieving high-resolution NMR spectroscopy on solutions at GPa pressure

Recent theoretical advances and molecular-dynamic estimates of the dielectric constant of water have extended the HKF model for aqueous solution chemistry up to 6.0 gigapascals (GPa), which are conditions well beyond the capabilities of conventional NMR spectroscopy (Pan et al., 2013; Sverjensky et al., 2014, see also Wasserman and others, 1995). These developments provide strong motivation to design a simple NMR probe that allows experiments on solutions, at high resolution, to pressures of a few GPa (Pautler et al., 2014; Ochoa et al., 2015; 2016). Here we describe the performance of a compact NMR probe that can reach several GPa pressures. The probe is made by placing a solenoid microcoil inside of a standard piston-cylinder device used in solid-state physics. High pressures are achieved in the sample by applying force to a coaxial piston. Early designs of the probe, although useful, were limited in sample size to ~10-15μL. Here we describe modifications that allow greatly improved resolution and sensitivity, including 1H-1H NMR correlation spectroscopy, on solutions at 2.8 GPa pressure. Sample sizes can be expanded if, instead of a standard NMR spectrometer that is built around a superconducting magnet, one employs a magnetic-resonance imaging (MRI) system that is built around a permanent magnet. The MRI systems can apply larger magnetic field gradients than conventional spectrometers, and thus have more robust shimming capability, which is needed because of the juxtaposition of different alloys in the pressure cell. More importantly, these systems can have magnetic fields that are oriented perpendicular to the magnet bore, which allows rotation of the coil within the axis of the pressure cell to increase sample volumes and pressure. Sensitivity is improved by replacing the traditional, but reduced-volume, closed sample container mounted in the center of the NMR detection coil with an open NMR coil that dangles freely in solution, thus making the sample solution itself the pressure-transmission fluid. The efficacy of these modifications are demonstrated by measuring 1 H NMR spectra for ethyl alcohol and ethyl alcohol/methyl alcohol mixtures at pressures up to 2.8 GPa. As a result, further developments are discussed that will allow geochemists to acquire aqueous solution NMR spectra at higher 3-4 GPa pressures.

58 GEOSCIENCES↗

Spectral characterization of flash and high flux x-ray radiographic sources with a magnetic Compton spectrometer

In this article, we present a new analysis method applied to revitalize permanent magnet Compton spectrometers used to measure photon energy spectra in the MeV range. The inversion of the measured electron distribution to determine the original photon distribution is achieved via a method of consistent coupled radiation transport and magnetic field mapping of the input photon spectra to the measured electron distribution. The method of linear least squares was used to perform the unfolding of the electron distribution to the initial photon spectra, without any assumptions made regarding the electron distribution. We present an application of this method to data from a nominal 19.4 MeV flash radiographic source (the first axis of the Dual Axis Radiographic Hydro-Test Facility) capable of generating 500 R @ 1 m in ~60 ns and a medical therapy source (a Scanditronix M22, Microtron) capable of variable energies with nominal endpoints of 6, 10, 15, and 20 MeV and an output of ~1000–2000 R/min @ 1 m. The results provide agreement between the modeled and unfolded experimentally measured photon spectra as quantified by statistical tests, from 1.5 to 20 MeV. Experimental results are presented as well as a discussion of the novel MCNP6-based simulations and methods for reconstruction of the spectra.

47 OTHER INSTRUMENTATION↗

Accelerator Physics Lessons From CBETA, the First Multi-turn SRF ERL

The Cornell-BNL ERL Test Accelerator (CBETA) has been designed, constructed, and commissioned in a collaboration between Cornell and Brookhaven National Laboratory (BNL). It focuses on energy-saving measures in accelerators, including permanent magnets, energy recovery, and superconductors; it has thus been referred to as a green accelerator. CBETA has become the world's first Energy Recovery Linac (ERL) that accelerates through multiple turns and then recovers the energy in superconducting radiofrequency (SRF) cavities though multiple decelerating turns. The energy is then available to accelerate more beam. It has also become the first accelerator that operates 7 beams in the same large-energy aperture Fixed Field Alternating-gradient (FFA) lattice. The FFA is constructed of permanent combined function magnets and transports energies of 42, 78, 114, and 150 MeV simultaneously. Accelerator physics lessons from the commissioning period will be described and applications of such an accelerator from hadron cooling to EUV lithography and from nuclear physics to a compact Compton source will be discussed.

Deitrick, K. E.↗

Superstructure magnetic anisotropy in Fe 3 O 4 nanoparticle chains

Magnetic anisotropy is essential for many applications of ferromagnetic/ferrimagnetic materials, including permanent magnets and magnetic recording media. Attempts have been made recently to build up 3-D nanoparticle and quantum dot assemblies, however, it is not understood yet if a nanoparticle assembly can possess high magnetic anisotropy with low anisotropic materials. In this article, we report our discovery of high magnetic anisotropy resulted from Fe 3 O 4 nanoparticle chains. We started with closely-packed nanoparticle assemblies of spherical Fe 3 O 4 nanoparticles that exhibit low magnetocrystalline anisotropy and shape anisotropy, and corresponding negligible coercivity. When the nanoparticle assemblies are compressed under pressure, they form bundles or arrays that consist of Fe 3 O 4 chains with a length scale of several hundred nanometers. Magnetic measurements show that these Fe 3 O 4 chain arrays possess a high uniaxial magnetic anisotropy (K eff ~ 2.9×10 5 J/m 3 ) and significant magnetic coercivity. Our simulations reveal that interparticle magnetic dipolar interactions contribute to this type of superstructure magnetic anisotropy. This study demonstrates the feasibility and approaches to create “patterned” high magnetic anisotropy in nanoparticle superstructures/assemblies.

Mohapatra, Jeotikanta (ORCID:0000000151968626)↗

Distinct effect of Kondo physics on crystal field splitting in electron and spin spectroscopies

Magnetic anisotropy is a key feature of rare earth materials from permanent magnets to heavy fermions. Here we explore the complex interplay of Kondo physics and anisotropy, and their effect on different experimental probes of magnetic anisotropy in a minimal 𝐽=3/2 Anderson impurity model using the numerical renormalization group. While anisotropy suppresses Kondo screening, virtual valence fluctuations enhance the anisotropy. We find distinct renormalization of the magnetic anisotropy measured via dynamical spin response (inelastic neutron scattering) versus electronic excitations in the impurity spectral function (resonant inelastic x-ray and scanning tunneling spectroscopy). The two measurement types have different responses and dependencies on the temperature and Kondo scales.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of projection velocity and temperature on the reflection of ultracold atoms from a periodic one-dimensional corrugated magnetic potential

The spatial profile of ultracold atoms reflecting from an exponentially decaying magnetic potential depends on parameters such as the corrugation in the magnetic potential and the temperature of the atomic cloud. We report on experimental investigations of the effect of projection velocity which determines the strength of the interaction of the atom cloud with the magnetic potential and the effect of temperature of ultracold {sup 87}Rb atoms reflecting from a periodic one-dimensional corrugated magnetic potential. The magnetic potential is generated on an atom chip by a periodic permanent magnetic structure of period 10 {mu}m. The amplitude of the corrugation is controlled by applying a uniform external-bias magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gaussian approximation and single-spin measurement in magnetic resonance force microscopy with spin noise

A promising technique for measuring single electron spins is magnetic resonance force microscopy (MRFM), in which a microcantilever with a permanent magnetic tip is resonantly driven by a single oscillating spin. The most effective experimental technique is the oscillating cantilever-driven adiabatic reversals (OSCAR) protocol, in which the signal takes the form of a frequency shift. If the quality factor of the cantilever is high enough, this signal will be amplified over time to the point where it can be detected by optical or other techniques. An important requirement, however, is that this measurement process occurs on a time scale that is short compared to any noise which disturbs the orientation of the measured spin. We describe a model of spin noise for the MRFM system and show how this noise is transformed to become time dependent in going to the usual rotating frame. We simplify the description of the cantilever-spin system by approximating the cantilever wave function as a Gaussian wave packet and show that the resulting approximation closely matches the full quantum behavior. We then examine the problem of detecting the signal for a cantilever with thermal noise and spin with spin noise, deriving a condition for this to be a useful measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Active Measurement of Plasma Parameters in Over-Dense MFE Reactor Plasma Using High Frequency Beat-Wave Resonantly Generated Thermal Bernstein Waves

UC Davis was funded to explore the combination of beat-wave excitation and laser scattering to make completely non-invasive determination of local plasma conditions. This involves the use of two high frequency mm-wave sources of differing frequencies (the pump waves) to excite plasma waves at the difference of the frequencies, which is known as the beat frequency. The difference frequency or the frequency of the beat wave is chosen so that we produce plasma waves whose fluctuating electron density is a sensitive function of plasma parameters at the location where the source waves overlap. This fluctuation can be detected from outside the plasma, by measuring the deflection of a probe beam directed at the overlap region between the two pump waves (i.e., collective scattering). This work is an extension of mm-wave frequencies of a 10 GHz beat-wave experiment conducted on the DDT toroidal device (see Fig. 1) in a magnetized plasma where the excited Langmuir wave is replaced by the magnetized upper hybrid wave. Here, two high power (> 1 kW) ~94 GHz pump sources will be employed to match the upper hybrid resonance. The primary envisioned experiment is to drive the electron Bernstein wave (EBW) in the interior of a magnetized plasma. The EBW is a hot-plasma electrostatic wave, which cannot propagate in vacuum. Roots of the EBW dispersion relation occur at frequencies slightly higher than harmonics of the electron cyclotron frequency. Use of the EBW has particular advantages for measuring plasma magnetic field in plasmas with relatively high density and low magnetic field, as is the case in spherical tokamaks. This is the “over dense” condition of future efficient high beta magnetic confinement fusion reactors such as the spherical tokamak (STs). The overarching goal of the proposed project is to demonstrate beat wave EBW excitation in low density and temperature parameters that are directly scalable to over-dense spherical tokamaks such as NSTX or MAST, where measurement of magnetic field by electron cyclotron emission (ECE) is experimentally complex, and requires models of plasma profiles in order to interpret results. In such experiments, availability of point measurements of magnetic field strength provided by a beat-wave diagnostic would serve as a powerful independent check on the ECE results, serving to validate the assumed profiles and wave-propagation models used. The first step was to assemble/modify the target chamber in which the beat-wave plasma experiments will take place. Here, the target chamber of the CTIX compact-toroid (spheromak) injector was chosen. At the time that the proposal was submitted, the aim was to conduct the experiments in the CTIX experimental facilities located at the Livermore campus of UC Davis using microwave/mm-wave equipment brought from the main campus., However, by the time DoE funds for this project were awarded, the CTIX experimental facilities located at the Livermore campus of UC Davis were in the process of being shut down due to the closure of the Livermore campus by Lawrence Livermore National Laboratory (LLNL). Consequently, the equipment needed for this project was crated up and shipped from Livermore to Davis as part of the laboratory shutdown after space on campus was secured and College of Engineering approval secured. Once it arrived in Davis on December 20, 2018, work on the project began in earnest with the initial efforts directed toward developing a new plasma target source. Because of the shutdown of the CTIX facility, the scope of the project thus had to be reduced due to the abbreviated amount of time allocated to the project once the shutdown/move had been completed. Chamber modifications have been completed, including the fabrication and installation of a 38 GHz interferometer, as described in Sec. 3. The thermionic plasma source has been tested and characterized. The magnetic field required for the EBW experiments will be generated by permanent magnets mounted on plates positioned above and below the chamber. Magnetic simulations have been performed, and show that a 3-ring magnet arrangement on each plate, with a plate separation of 50 cm, is required to achieve the ~100 G uniform magnetic field in the interaction region that we feel is necessary to ensure good EBW coupling. We proved unable to successfully revive either of Prof. Luhmann’s two high power (≥20 kW) 94 GHz millimeter-wave sources after their extended time in storage and decided to postpone further efforts and concentrate on slightly lower power sources. Consequently, we were successful in reviving a ~2 kW extended klystron amplifier (EIK), which together with a ~2 kW extended interaction oscillator (EIO) will provide the two pump sources required for the project. Safe operation of the EIO requires extensive modifications to one of Prof. Luhmann’s pulse modulators - these modulator modifications are ongoing, which has unfortunately delayed the planned beat-wave experiments. Details of this work are provided in Sec. 3. Even though project funding has now ended, we still plan to proceed to complete the EIO pulse modulator modifications, install the two ~94 GHz pump wave sources on the target chamber, and conduct unmagnetized tests of the beat-wave concept which involve coupling to unmagnetized electron plasma waves rather than magnetized EBWs. Should these experiments prove successful, we plan to submit a follow-up proposal for additional funding which would allow us to undertake the magnetized EBW experiments.

42 ENGINEERING↗

Toughening Sm–Co sintered magnets via microstructure modification with additives

We report the mechanical properties of the brittle Smsingle bondCo permanent magnets are of great practical significance. However, studies on the magnets have mostly focused on their magnetic properties. This paper reports the modified microstructure and refined unimodal grain size, enhanced flexural strength, and magnetic properties of Sm 2 (Co,Fe,Cu,Zr) 17 sintered magnets doped with La 2 O 3 , MgO, and CaF 2 fine particulates. The correlations between microstructure, phase composition, and mechanical and magnetic properties were studied. Doping of a small amount (e.g., 0.5–3 wt%) of La 2 O 3 , MgO, or CaF 2 fine particulates could significantly refine the unimodal grain sizes of the Smsingle bondCo magnets via the Zener pinning effect. Moreover, doping significantly improved the flexural strengths σ of the magnets. For example, the σ values of the magnets with 0.5 wt% MgO, 1 wt% La 2 O 3 , and 1 wt% CaF 2 were approximately 65%, 63%, and 42% higher than that of the reference magnet, respectively. Micromechanical simulations revealed that the fine particles of La 2 O 3 could deflect crack growth, while the CaF 2 particles could attract or arrest cracks during the fracture process. The mechanical strengthening effect was mainly due to grain size refinement. The Smsingle bondCo magnets with 0.5–1.5 wt% CaF2 and 0.5 wt% La 2 O 3 exhibited excellent magnetic properties while doping 1–3 wt% La2O3 and 0.5–3 wt% MgO deteriorated magnetic performance. The rational design of CaF 2 - or La 2 O 3 -doped microstructure can be an economical and effective method for producing toughened Sm–Co sintered magnets with high magnetic performance.

36 MATERIALS SCIENCE↗

Element-resolved magnetism across the temperature- and pressure-induced spin reorientation in MnBi

Rare-earth free permanent magnet MnBi (NiAs-type crystal structure) displays strong magnetic anisotropy above its 90 K spin reorientation transition (SRT). X-ray magnetic circular dichroism (XMCD) shows induced magnetism in Bi 5d band, which is strongly coupled to the magnetism of Mn. A clear increase in Bi orbital-to-spin moment ratio is observed above the SRT. Hydrostatic pressure mimics the e*ect of temperature on the SRT, and the pressure effect also leads to anisotropic lattice contraction, which is known to be induced by cooling. These results reveal that temperature and pressure can similarly induce the coupled structural and magnetic responses, suggesting the importance of the anisotropic lattice change and Mn-Bi hybridization to the magnetic anisotropy change across the SRT.

36 MATERIALS SCIENCE↗

Temperature Measurements in the Magnetic Measurement Facility

Several key LCLS undulator parameter values depend strongly on temperature primarily because of the permanent magnet material the undulators are constructed with. The undulators will be tuned to have specific parameter values in the Magnetic Measurement Facility (MMF). Consequently, it is necessary for the temperature of the MMF to remain fairly constant. Requirements on undulator temperature have been established. When in use, the undulator temperature will be in the range 20.0 {+-} 0.2 C. In the MMF, the undulator tuning will be done at 20.0 {+-} 0.1 C. For special studies, the MMF temperature set point can be changed to a value between 18 C and 23 C with stability of {+-}0.1 C. In order to ensure that the MMF temperature requirements are met, the MMF must have a system to measure temperatures. The accuracy of the MMF temperature measurement system must be better than the {+-}0.1 C undulator tuning temperature tolerance, and is taken to be {+-}0.01 C. The temperature measurement system for the MMF is under construction. It is similar to a prototype system we built two years ago in the Sector 10 alignment lab at SLAC. At that time, our goal was to measure the lab temperature to {+-}0.1 C. The system has worked well for two years and has maintained its accuracy. For the MMF system, we propose better sensors and a more extensive calibration program to achieve the factor of 10 increase in accuracy. In this note we describe the measurement system under construction. We motivate our choice of system components and give an overview of the system. Most of the software for the system has been written and will be discussed. We discuss error sources in temperature measurements and show how these errors have been dealt with. The calibration system is described in detail. All the LCLS undulators must be tuned in the Magnetic Measurement Facility at the same temperature to within {+-}0.1 C. In order to ensure this, we are building a system to measure the temperature of the undulators to {+-}0.01 C. This note describes the temperature measurement system under construction.

43 PARTICLE ACCELERATORS↗

Modeling a ring magnet in ALEGRA

We show here that Sandia's ALEGRA software can be used to model a permanent magnet in 2D and 3D, with accuracy matching that of the open-source commercial software FEMM. This is done by conducting simulations and experimental measurements for a commercial-grade N42 neodymium alloy ring magnet with a measured magnetic field strength of approximately 0.4 T in its immediate vicinity. Transient simulations using ALEGRA and static simulations using FEMM are conducted. Comparisons are made between simulations and measurements, and amongst the simulations, for sample locations in the steady-state magnetic field. The comparisons show that all models capture the data to within 7%. The FEMM and ALEGRA results agree to within approximately 2%. The most accurate solutions in ALEGRA are obtained using quadrilateral or hexahedral elements. In the case where iron shielding disks are included in the magnetized space, ALEGRA simulations are considerably more expensive because of the increased magnetic diffusion time, but FEMM and ALEGRA results are still in agreement. The magnetic field data are portable to other software interfaces using the Exodus file format.

36 MATERIALS SCIENCE↗

Aluminum bonded SmCo5 magnets with enhanced mechanical strength

Despite their versatility and easy manufacturability, polymer-bonded magnets find limited application due to their limited mechanical properties and temperature resistance. In this study, we developed mechanically robust, aluminum-bonded SmCo5 magnets by utilizing a low-temperature, shear-assisted friction consolidation technique. Bonded magnets with varying magnetic phase content were fabricated at processing temperature of 500°C, and their microstructures, magnetic, mechanical, and electrical properties were systematically investigated. The resulting bonded-magnets showed effective consolidation with nanocrystalline microstructures. Magnetic properties were found to be tunable through variations in binder phase content, with coercivity reaching values up to 15.3 kOe (1217.5 kA/m) and maximum magnetic energy product up to 3.6 MGOe (28.7 kJ/m3), which are comparable to other bonded magnets. Electrical resistivities were lower than the polymer-bonded magnets, but comparable to the sintered ones. We observed an average flexural strength of 223 MPa for 60 vol.% SmCo5/Al sample, which is nearly two times higher than the reported values for sintered and bonded Sm-Co magnets. Our research demonstrated an effective approach to fabricate metal-bonded permanent magnets with superior magnetic and mechanical properties potentially applicable for high temperature applications.

Poudel Chhetri, Tej Bahadur↗

Magnetic properties and magnetocrystalline anisotropy of Nd 2 Fe 17 , Nd 2 Fe 17 X 3 , and related compounds

The electronic and magnetic properties of Nd 2 Fe 17 and Nd 2 Fe 17 X 3 (X = C or N) compounds have been calculated using the first-principles density functional calculations. Among these, the nitrogen and carbon interstitial compounds exhibit all of the required properties such as a saturation moment of 1.6 T, Curie temperature of 700–750 K, however easy magnetic axis lies in the planar direction making them less attractive for permanent magnet applications. The calculated magnetocrystalline anisotropy energy is found to be -2.7 MJ/m 3 for Nd 2 Fe 17 C 3 and -4.7 MJ/m 3 for Nd 2 Fe 17 N 3 . Finally, we further explored the possibility of changing the easy axis direction through La/Ce alloying at Nd site. Although the MAE is found to be smaller in magnitude for all the La/Ce alloys it still maintains planar direction.

36 MATERIALS SCIENCE↗

A Flexible Field Mapping System for Accelerator Magnets

Magnetic field mapping is a fundamental magnetic measurement method that typically uses Hall and NMR sensors. In magnet measurement facilities, such systems are likely used in various configurations suitable for a specific task at hand. To address this diversity, the authors developed a flexible field mapping system capable of being configured and tailored to each particular measurement case. Further, the system needs to address the variability introduced by differences in sensors and their readout systems, probe positioning systems, power supply systems, and required mapping geometry (mapping space and grid, measurement steps and sequences). Although the discussed field mapping systems range from a self-propelled multi-sensor mapper of a large detector magnet to a single 3D Hall sensor system to scan a small permanent magnet, they were all built with the same core mapping system. The variability present in field mapping systems, the measurement system architecture addressing this variability, as well as examples of several field mapping systems built in this architecture are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗