Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Measurement of the π - -Ar total hadronic cross section at the LArIAT experiment

We present the first measurement of the negative pion total hadronic cross section on argon in a restricted phase space, which we performed at the Liquid Argon In A Testbeam (LArIAT) experiment. All hadronic reaction channels, as well as hadronic elastic interactions with scattering angle greater than 5° are included. The pions have kinetic energies in the range 100–700 MeV and are produced by a beam of charged particles impinging on a solid target at the Fermilab test beam facility. LArIAT employs a 0.24 ton active mass liquid argon time projection chamber (LArTPC) to measure the pion hadronic interactions. For this measurement, LArIAT has developed the “thin slice method,” a new technique to measure cross sections with LArTPCs. While moderately higher, our measurement of the π - -Ar total hadronic cross section is generally in agreement with the geant4 prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Some characteristic features of the construction of the amplifying channel for working with semiconductor detectors in the charged particle energy spectrometer

A transistorized spectrometric amplifier with a shaper is reported that selects the shape of the frequency characteristic of the amplifying channel for which the primary frequency spectrum of the signal will pass, but where the noise spectrum is limited to the maximum. A procedure is presented for selecting the shaping circuits and their inclusion principles.

Kuzyuta, E. I.↗

Faint object studies with IUE

To push IUE to the limit on faint sources, detector background contributions from the night sky, energetic particle events, detector flaws and calibration errors must be established. Multiple spectra of faint nebular filaments were intercompared with multiple spectra of sky background in a study of the Crab Nebula. Radiation hits dominate the background of any long exposure spectrum but bright spots of the detector can be misconstrued to be radiation hits, or spectral information. The spectra were normalized and then, on a pixel by pixel basis, average and median spectra were constructed. Four data sets (six SWP nebular, six SWP sky, six LWR nebular, and six LWR sky) were processed in parallel. A number of bright and faint background features remain, especially for SWP images. Several features could be misconstrued to be emission from a faint object.

Gull, T. R.↗

Effect of energy deposited by cosmic-ray particles on interferometric gravitational wave detectors

We investigated the noise of interferometric gravitational wave detectors due to heat energy deposited by cosmic-ray particles. We derived a general formula that describes the response of a mirror against a cosmic-ray passage. We found that there are differences in the comic-ray responses (the dependence of temperature and cosmic-ray track position) in cases of interferometric and resonant gravitational wave detectors. The power spectral density of vibrations caused by low-energy secondary muons is 100 times smaller than the goal sensitivity of future second-generation interferometer projects, such as LCGT and Advanced LIGO. The arrival frequency of high-energy cosmic-ray muons that generate enough large showers inside mirrors of LCGT and Advanced LIGO is one per a millennium. We also discuss the probability of exotic-particle detection with interferometers.

79 ASTRONOMY AND ASTROPHYSICS↗

RBE estimation of proton radiation fields using a {Delta}E-E telescope

A new monolithic silicon {Delta}E-E telescope was evaluated in unmodulated and modulated 100 MeV proton beams used for hadron therapy. Compared to a classical microdosimetry detector, which provides one-dimensional information on lineal energy of charged particles, this detector system provides two-dimensional information on lineal energy and particle energy based on energy depositions, collected in coincidence, within the {Delta}E and E stages of the detector. The authors investigated the possibility to use the information obtained with the {Delta}E-E telescope to determine the relative biological effectiveness (RBE) at defined locations within the proton Bragg peak and spread-out Bragg peak (SOBP). An RBE matrix based on the established in vitro V79 cell survival data was developed to link the output of the device directly to RBE({alpha}), the RBE in the low-dose limit, at various depths in a homogeneous polystyrene phantom. In the SOBP of a 100 MeV proton beam, the RBE({alpha}) increased from 4.04 proximal to the SOBP to a maximum value of 5.4 at the distal edge. The {Delta}E-E telescope, with its high spatial resolution, has potential applications to biologically weighted hadron treatment planning as it provides a compact and portable means for estimating the RBE in rapidly changing hadron radiation fields within phantoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark matter directionality revisited with a high pressure xenon gas detector

An observation of the anisotropy of dark matter interactions in a direction-sensitive detector would provide decisive evidence for the discovery of galactic dark matter. Directional information would also provide a crucial input to understanding its distribution in the local Universe. Most of the existing directional dark matter detectors utilize particle tracking methods in a low-pressure gas time projection chamber. These low pressure detectors require excessively large volumes in order to be competitive in the search for physics beyond the current limit. In order to avoid these volume limitations, we consider a novel proposal, which exploits a columnar recombination effect in a high-pressure gas time projection chamber. The ratio of scintillation to ionization signals observed in the detector carries the angular information of the particle interactions. In this paper, we investigate the sensitivity of a future directional detector focused on the proposed high-pressure Xenon gas time projection chamber. We study the prospect of detecting an anisotropy in the dark matter velocity distribution. We find that tens of events are needed to exclude an isotropic distribution of dark matter interactions at 95% confidence level in the most optimistic case with head-to-tail information. However, one needs at least 10-20 times more events without head-to-tail information for light dark matter below ~50 GeV. For an intermediate mass range, we find it challenging to observe an anisotropy of the dark matter distribution. Our results also show that the directional information significantly improves precision measurements of dark matter mass and the elastic scattering cross section for a heavy dark matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed particles in EAS at Akeno

Using two 2.25 square meter fast scintillation detectors, delayed particles in cosmic ray showers (CRS) have been observed at Akeno Observatory. These are set under 1 m concrete and 2.5 cm lead plates respectively. About 2500 CRS are analyzed. The lateral distribution of delayed particles for the CRS size 10 to the 7th power is flatter than that for to the 7th power. The lateral density of delayed particles is almost constant for the size range 2.2 X 10 to the 5th power approx. 10 to the 7th power and increases rapidly above 10 to the 7th power. These facts may suggest change of nuclear interaction at 10 to the 7th power and substantially the existence of heavy particles with long life.

Sakuyama, H.↗

Exotic particles at the DUNE near detector from charged pion scattering

Fixed-target proton-beam experiments produce a multitude of charged pions that rescatter in the beam dump. These charged pion scattering events can be an additional irreducible source of exotic particles which couple to photons or hadrons. We analyze the sensitivity of the DUNE near detector complex to millicharged particles (MCPs) and heavy axionlike particles (ALPs) with low-energy couplings to gluons. Using the framework of chiral perturbation theory, we demonstrate regimes of parameter space where the charged pion production channel dominates over previously considered production mechanisms for both MCPs and ALPs, thereby improving the sensitivity of DUNE to these new particles compared to previous studies. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New light weakly-coupled particle searches in a neutrino detector

Neutrino detectors at the accelerator machines of the Intensity Frontier in particle physics are becoming commonplace. As their capabilities are being understood, they seem to have the potential for studies beyond the neutrino oscillations measurements. Besides these primary neutrino physics goals, a number of exotic searches can be done with such detectors in general, and the NOvA detectors that we present here, as a particular example. Specifically, we focus on simulating signatures in NOvA experiment's Near-Detector (300 ton, 900 m from the NuMI target of Fermilab) that correspond to beam-generated new physics states from hidden sectors, dark sectors, axion-like particles, heavy or sterile neutrinos, and heavy photons. As there are no physics generators that can inherently include such states, along with the mainstream production branches, we present here the initial stages of an effort to incorporate these signatures manually in the overall simulation framework of the NOvA experiment. For this, we discuss examples and examine the potential and challenges for detecting such signatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmo-Particle Searches for Supersymmetry at the Collider Detector at Fermilab

Some theories of particle physics are so compelling that it is worth doing a comprehensive and systematic set of experimental searches to see if they are realized in nature. Supersymmetry is one such theory. This review focuses on the motivation for a broad set of cosmology-inspired search strategies at the Tevatron and on their implementation and results at the Collider Detector at Fermilab (CDF) with the first few fb{sup -1} of integrated luminosity of data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gaussian mixture models as automated particle classifiers for fast neutron detectors

Pulse shape discrimination (PSD) is the task of classifying electronic pulse shapes for different particle types such as gamma rays and fast neutrons interacting in scintillators and read out by photo sensitive detectors. This field has been limited in its adoption of techniques found in the statistical learning community. Methods initially employed in the 1960s for analog electronic circuitry persist in the current PSD literature describing operations performed on digitized pulses, which are amenable to statistical rigor. Despite vast amounts of data collected at low energy levels, traditional PSD methods are unable to discriminate particles below a certain threshold. As such, in this work, Gaussian mixture models (GMMs) are used as a clustering technique for fast neutron detection in the absence of labeled data. GMMs yield improvements spanning the energy spectrum in a desirably efficient, unsupervised fashion. An extension, the Dirichlet Process GMM, provides further flexibility and classification improvement.

97 MATHEMATICS AND COMPUTING↗

Radial distribution of charged particles in a magnetic field

The radial spread of charged particles emitted from a point source in a magnetic field is a potential source of systematic error for any experiment where magnetic fields guide charged particles to detectors with finite size. Assuming uniform probability as a function of the phase along the particle’s helical trajectory, an analytic solution for the radial probability distribution function follows which applies to experiments in which particles are generated throughout a volume that spans a sufficient length along the axis of a homogeneous magnetic field. This approach leads to the same result as a different derivation given by Dubbers et al., Nucl. Instrum. Methods Phys. Res., Sect. A 763, 112–119 (2014). But the constant phase approximation does not strictly apply to finite source volumes or fixed positions, which lead to local maxima in the radial distribution of emitted particles at the plane of the detector. A simple method is given to calculate such distributions, then the effect is demonstrated with data from a {sup 207}Bi electron-conversion source in the superconducting solenoid magnet spectrometer of the Ultracold Neutron facility at the Los Alamos Neutron Science Center. Implications for neutron beta decay spectroscopy are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A detector for high frequency modulation in auroral particle fluxes

A high time resolution electron detector has been developed for use in sounding rocket studies of the aurora. The detector is used to look for particle bunching in the range 50 kHz-10 MHz. The design uses an electron multiplier and an onboard frequency spectrum analyzer. By using the onboard analyzer, the data can be transmitted back to ground on a single 93-kHz voltage-controlled oscillator. The detector covers the 50 kHz-10 MHz range six times per second and detects modulation on the order of a new percent of the total electron flux. Spectra are presented for a flight over an auroral arc.

Spiger, R. J.↗