Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

High-Energy 3D Calorimeter for Use in Gamma-Ray Astronomy Based on Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors

We will present a concept for a calorimeter based on a novel approach of 3D position-sensitive virtual Frisch-grid CdZnTe (hereafter CZT) detectors. This calorimeter aims to measure photons with energies from approximately 100 keV to 20 - 50 MeV . The expected energy resolution at 662 keV is better than 1% FWHM, and the photon interaction position-measurement accuracy is better than 1 mm in all 3 dimensions. Each CZT bar is a rectangular prism with typical cross-section from 5 x 5 to 7 x 7 mm2 and length of 2 - 4 cm. The bars are arranged in modules of 4 x 4 bars, and the modules themselves can be assembled into a larger array. The 3D virtual voxel approach solves a long-standing problem with CZT detectors associated with material imperfections that limit the performance and usefulness of relatively thick detectors (i.e., greater than 1 cm). Also, it allows us to use the standard (unselected) grade crystals, while achieving the energy resolution of the premium detectors and thus substantially reducing the cost of the instrument. Such a calorimeter can be successfully used in space telescopes that use Compton scattering of gamma rays, such as AMEGO, serving as part of its calorimeter and providing the position and energy measurement for Compton-scattered photons (like a focal plane detector in a Compton camera). Also, it could provide suitable energy resolution to allow for spectroscopic measurements of gamma ray lines from nuclear decays.

Moiseev, A.↗

Time Resolution Measurements of EJ-232Q With Single- and Dual-Sided Readouts

In view of its importance to applications in high energy physics, nuclear security, and time-of-flight PET, the time resolution of 0.5% benzophenone-quenched EJ-232Q plastic scintillators of various lengths was studied using a fast waveform digitizer and fast PMTs. The scintillator sizes were 5 mm × 5 mm × 10, 25, 50, 75, or 100 mm. First, the timing measurements were performed by using a single PMT reading out one end. The degradation in time resolution with increasing scintillator length was studied. The irradiation geometry was also observed to have a non-negligible impact on the time resolution due to the variation of depth-of-interaction positions, especially for the scintillators with a high aspect ratio. Second, two PMTs were employed for a dual-sided readout. This readout together with the mean time method was demonstrated to be an effective approach to improve the timing performance since the depth-of-interaction-related effect was considerably mitigated. A time resolution of 79 ± 1 ps (full-width at half-maximum) has been achieved for the 5 × 5 × 10 mm 3 scintillator. The 5 × 5 × 100 mm 3 scintillator can still provide a time resolution as good as 172 ± 1 ps. Here, the energy range used for each was between 340 keVee and 450 keVee. In addition, the time information from individual PMTs in a dual-sided readout was able to show a time resolution almost identical to that determined with the mean-time-based technique after correcting for the depth-of-interaction variation for the 100 mm long scintillator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the role of last closed drift shell dynamics in driving fast losses and Van Allen radiation belt extinction

We present observations of very fast radiation belt loss as resolved using high time resolution electron flux data from the constellation of Global Positioning System (GPS) satellites. The time scale of these losses is revealed to be as short as ~0.5–2 hr during intense magnetic storms, with some storms demonstrating almost total loss on these time scales and which we characterize as radiation belt extinction. The intense March 2013 and March 2015 storms both show such fast extinction, with a rapid recovery, while the September 2014 storm shows fast extinction but no recovery for around 2 weeks. By contrast, the moderate September 2012 storm which generated a three radiation belt morphology shows more gradual loss. Here, we compute the last closed drift shell (LCDS) for each of these four storms and show a very strong correspondence between the LCDS and the loss patterns of trapped electrons in each storm. Most significantly, the location of the LCDS closely mirrors the high time resolution losses observed in GPS flux. The fast losses occur on a time scale shorter than the Van Allen Probes orbital period, are explained by proximity to the LCDS, and progress inward, consistent with outward transport to the LCDS by fast ultralow frequency wave radial diffusion. Expressing the location of the LCDS in L*, and not model magnetopause standoff distance in units of RE, clearly reveals magnetopause shadowing as the cause of the fast loss observed by the GPS satellites.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance characterization of high quantum efficiency metal package photomultiplier tubes for time-of-flight and high-resolution PET applications

Purpose: Metal package photomultiplier tubes (PMTs) with a metal channel dynode structure have several advanced features for devising such time-of-flight (TOF) and high spatial resolution positron emission tomography (PET) detectors, thanks to their high packing density, large effective area ratio, fast time response, and position encoding capability. Here, we report on an investigation of new metal package PMTs with high quantum efficiency (QE) for high-resolution PET and TOF PET detector modules. Methods: The latest metal package PMT, the Hamamatsu R11265 series, is served with two kinds of photocathodes that have higher quantum efficiency than normal bialkali (typical QE ≈ 25%), super bialkali (SBA; QE ≈ 35%), and ultra bialkali (UBA; QE ≈ 43%). In this study, the authors evaluated the performance of the new PMTs with SBA and UBA photocathodes as a PET detector by coupling various crystal arrays. They also investigated the performance improvements of high QE, focusing in particular on a block detector coupled with a lutetium-based scintillator. A single 4 × 4 × 10 mm{sup 3} LYSO, a 7 × 7 array of 3 × 3 × 20 mm{sup 3} LGSO, a 9 × 9 array of 1.2 × 1.2 × 10 mm{sup 3} LYSO, and a 6 × 6 array of 1.5 × 1.5 × 7 mm{sup 3} LuYAP were used for evaluation. All coincidence data were acquired with a DRS4 based fast digitizer. Results: This new PMT shows promising crystal positioning accuracy, energy and time discrimination performance for TOF, and high-resolution PET applications. The authors also found that a metal channel PMT with SBA was enough for both TOF and high-resolution application, although UBA gave a minor improvement to time resolution. However, significant performance improvement was observed in relative low light output crystals (LuYAP) coupled with UBA. Conclusions: The results of this study will be of value as a useful reference to select PMTs for high-performance PET detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micropillar displacements by cell traction forces are mechanically correlated with nuclear dynamics

Cells sense physical cues at the level of focal adhesions and transduce them to the nucleus by biochemical and mechanical pathways. While the molecular intermediates in the mechanical links have been well studied, their dynamic coupling is poorly understood. In this study, fibroblast cells were adhered to micropillar arrays to probe correlations in the physical coupling between focal adhesions and nucleus. For this, we used novel imaging setup to simultaneously visualize micropillar deflections and EGFP labeled chromatin structure at high spatial and temporal resolution. We observed that micropillar deflections, depending on their relative positions, were positively or negatively correlated to nuclear and heterochromatin movements. Our results measuring the time scales between micropillar deflections and nucleus centroid displacement are suggestive of a strong elastic coupling that mediates differential force transmission to the nucleus. - Highlights: • Correlation between focal adhesions and nucleus studied using novel imaging setup. • Micropillar and nuclear displacements were measured at high resolution. • Correlation timescales show strong elastic coupling between cell edge and nucleus.

60 APPLIED LIFE SCIENCES↗

Determinations by Seasat of atmospheric water and synoptic fronts

It is shown by means of radiosonde data from the Joint Air-Sea Interaction (JASIN) experiment that the Seasat Scanning Multichannel Microwave Radiometer (SMMR) atmospheric water vapor distributions, taken over 600-km wide swaths with a resolution of 54 km, can be used to detect the position of atmospheric fronts in the lower troposphere. In addition to the fact that, unlike visible and IR radiometry, the SMMR determinations are not hampered by extensive cirrus or by a lack of frontal clouds, they use more channels, allowing better discrimination between the effects of liquid water, water vapor and sea state, and show improved spatial resolution. Data analysis results show that the SMMR atmospheric water vapor distributions have an accuracy comparable to that of in situ radiosonde measurements.

Taylor, P. K.↗

Global Ionospheric Perturbations Monitored by the Worldwide GPS Network

Based on the delays of these (Global Positioning System-GPS)signals, we have generated high resolution global ionospheric TEC (Total Electronic Changes) maps at 15-minute intervals. Using a differential method comparing storm time maps with quiet time maps, we find that the ionopshere during this time storm has increased significantly (the percentage change relative to quiet times is greater than 150 percent) ...These preliminary results (those mentioned above plus other in the paper)indicate that the differential maping method, which is based on GPS network measurements appears to be a useful tool for studying the global pattern and evolution process of the entire ionospheric perturbation.

Global Positioning System GPS TEC Total Electronic↗

Scattering-type Scanning Near-Field Optical Microscopy of Polymer-Coated Gold Nanoparticles

Scattering-type scanning near-field optical microscopy (s-SNOM) has emerged over the past years as a powerful characterization tool that can probe important properties of advanced materials and biological samples in a label-free manner, with spatial resolutions lying in the nanoscale realm. In this work, we explore such usefulness in relationship with an interesting class of materials: polymer-coated gold nanoparticles (NPs). As thoroughly discussed in recent works, the interplay between the Au core and the polymeric shell has been found to be important in many applications devoted to biomedicine. We investigate bare Au NPs next to polystyrenesulfonate (PSS) and poly(diallyldimethylammonium chloride) (PDDA) coated ones under 532 nm laser excitation, an wavelength matching the surface plasmon band of the custom-synthesized nanoparticles. We observe consistent s-SNOM phase signals in the case of bare and shallow-coated Au NPs, whereas for thicker shell instances, these signals fade. For all investigated samples, the s-SNOM amplitude signals were found to be very weak, which may be related to reduced scattering efficiency due to absorption of the incident beam. We consider these observations important, as they may facilitate studies and applications in nanomedicine and nanotechnology where the precise positioning of polymer-coated Au NPs with nanoscale resolution is needed besides their dielectric function and related intrinsic optical properties, which are also quantitatively available with s-SNOM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plastic scintillation detectors for time-of-flight mass measurements

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A conformation-dependent stereochemical library improves crystallographic refinement even at atomic resolution

A script was created to allow SHELXL to use the new CDL v.1.2 stereochemical library which defines the target values for main-chain bond lengths and angles as a function of the residue’s ϕ/ψ angles. Test refinements using this script show that the refinement behavior of structures at resolutions even better than 1 Å is substantially enhanced by the use of the new conformation-dependent ideal geometry paradigm. To utilize a new conformation-dependent backbone-geometry library (CDL) in protein refinements at atomic resolution, a script was written that creates a restraint file for the SHELXL refinement program. It was found that the use of this library allows models to be created that have a substantially better fit to main-chain bond angles and lengths without degrading their fit to the X-ray data even at resolutions near 1 Å. For models at much higher resolution (∼0.7 Å), the refined model for parts adopting single well occupied positions is largely independent of the restraints used, but these structures still showed much smaller r.m.s.d. residuals when assessed with the CDL. Examination of the refinement tests across a wide resolution range from 2.4 to 0.65 Å revealed consistent behavior supporting the use of the CDL as a next-generation restraint library to improve refinement. CDL restraints can be generated using the service at http://pgd.science.oregonstate.edu/cdl{sub s}helxl/.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Localization and orientation of heavy-atom cluster compounds in protein crystals using molecular replacement

A new approach is presented that allows the efficient localization and orientation of heavy-atom cluster compounds used in experimental phasing by a molecular replacement procedure. This permits the calculation of meaningful phases up to the highest resolution of the diffraction data. Heavy-atom clusters (HA clusters) containing a large number of specifically arranged electron-dense scatterers are especially useful for experimental phase determination of large complex structures, weakly diffracting crystals or structures with large unit cells. Often, the determination of the exact orientation of the HA cluster and hence of the individual heavy-atom positions proves to be the critical step in successful phasing and subsequent structure solution. Here, it is demonstrated that molecular replacement (MR) with either anomalous or isomorphous differences is a useful strategy for the correct placement of HA cluster compounds. The polyoxometallate cluster hexasodium α-metatungstate (HMT) was applied in phasing the structure of death receptor 6. Even though the HA cluster is bound in alternate partially occupied orientations and is located at a special position, its correct localization and orientation could be determined at resolutions as low as 4.9 Å. The broad applicability of this approach was demonstrated for five different derivative crystals that included the compounds tantalum tetradecabromide and trisodium phosphotungstate in addition to HMT. The correct placement of the HA cluster depends on the length of the intramolecular vectors chosen for MR, such that both a larger cluster size and the optimal choice of the wavelength used for anomalous data collection strongly affect the outcome.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Emergent universe in spatially flat cosmological model

The scenario of an emergent universe provides a promising resolution to the big bang singularity in universes with positive or negative spatial curvature. It however remains unclear whether the scenario can be successfully implemented in a spatially flat universe which seems to be favored by present cosmological observations. In this paper, we study the stability of Einstein static state solutions in a spatially flat Shtanov-Sahni braneworld scenario. With a negative dark radiation term included and assuming a scalar field as the only matter energy component, we find that the universe can stay at an Einstein static state past eternally and then evolve to an inflation phase naturally as the scalar field climbs up its potential slowly. In addition, we also propose a concrete potential of the scalar field that realizes this scenario.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structural Insights into Intermediate Steps in the Sir2 Deacetylation Reaction

Sirtuin enzymes comprise a unique class of NAD{sup +}-dependent protein deacetylases. Although structures of many sirtuin complexes have been determined, structural resolution of intermediate chemical steps are needed to understand the deacetylation mechanism. We report crystal structures of the bacterial sirtuin, Sir2Tm, in complex with an S-alkylamidate intermediate, analogous to the naturally occurring O-alkylamidate intermediate, and a Sir2Tm ternary complex containing a dissociated NAD{sup +} analog and acetylated peptide. The structures and biochemical studies reveal critical roles for the invariant active site histidine in positioning the reaction intermediate, and for a conserved phenylalanine residue in shielding reaction intermediates from base exchange with nicotinamide. The new structural and biochemical studies provide key mechanistic insight into intermediate steps of the Sir2 deacetylation reaction.

59 BASIC BIOLOGICAL SCIENCES↗

Improvements to the Photometric response and positional accuracy of the Yale PDS 2020G microdensitometer

The necessity to incorporate several hardware changes to optimize the Yale PDS 2020G microdensitometer for photometric and astrometric research are discussed. The properties of a new high speed photometer and a positional calibration system are described. The new photometer incorporates a high speed logarithmic analog to digital converter with more than 10 times the resolution of the former system and a cycle time of approximately 50 usec. The positional calibration system monitors the drunkenness of the stages with respect to fixed index lines and enables the correction of the +/- 5 micro stage errors to an accuracy of better than 1 micro.

Lee, J. F.↗

NEW SPATIALLY RESOLVED OBSERVATIONS OF THE T Cha TRANSITION DISK AND CONSTRAINTS ON THE PREVIOUSLY CLAIMED SUBSTELLAR COMPANION

We present multi-epoch non-redundant masking observations of the T Cha transition disk, taken at the Very Large Telescope and Magellan in the H, Ks, and L' bands. T Cha is one of a small number of transition disks that host companion candidates discovered by high-resolution imaging techniques, with a putative companion at a position angle of 78°, separation of 62 mas, and contrast of ΔL' = 5.1 mag. We find comparable binary parameters in our re-reduction of the initial detection images, and similar parameters in the 2011 L', 2013 NaCo L', and 2013 NaCo Ks data sets. We find a close-in companion signal in the 2012 NaCo L' data set that cannot be explained by orbital motion, and a non-detection in the 2013 MagAO/Clio2 L' data. However, Monte Carlo simulations show that the best fits to the 2012 NaCo and 2013 MagAO/Clio2 followup data may be consistent with noise. There is also a significant probability of false non-detections in both of these data sets. We discuss physical scenarios that could cause the best fits, and argue that previous companion and scattering explanations are inconsistent with the results of the much larger data set presented here.

79 ASTRONOMY AND ASTROPHYSICS↗

Four-dimensional (4D) tracking of high-temperature microparticles

High-speed tracking of hot and molten microparticles in motion provides rich information about burning plasmas in magnetic fusion. An exploding-wire apparatus is used to produce moving high-temperature metallic microparticles and to develop four-dimensional (4D) or time-resolved 3D particle tracking techniques. The pinhole camera model and algorithms developed for computer vision are used for scene calibration and 4D reconstructions. 3D positions and velocities are then derived for different microparticles. Velocity resolution approaches 0.1 m/s by using the local constant velocity approximation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-84: Measurement and Monte-Carlo Simulation of Electron Phase Spaces Using a Wide Angle Magnetic Electron Spectrometer

Purpose: To measure and simulate well-defined electron spectra using a linear accelerator and a permanent-magnetic wide-angle spectrometer to test the performance of a novel reconstruction algorithm for retrieval of unknown electron-sources, in view of application to diagnostics of laser-driven particle acceleration. Methods: Six electron energies (6, 9, 12, 15, 18 and 21 MeV, 40cm × 40cm field-size) delivered by a Siemens Oncor linear accelerator were recorded using a permanent-magnetic wide-angle electron spectrometer (150mT) with a one dimensional slit (0.2mm × 5cm). Two dimensional maps representing beam-energy and entrance-position along the slit were measured using different scintillating screens, read by an online CMOS detector of high resolution (0.048mm × 0.048mm pixels) and large field of view (5cm × 10cm). Measured energy-slit position maps were compared to forward FLUKA simulations of electron transport through the spectrometer, starting from IAEA phase-spaces of the accelerator. The latter ones were validated against measured depth-dose and lateral profiles in water. Agreement of forward simulation and measurement was quantified in terms of position and shape of the signal distribution on the detector. Results: Measured depth-dose distributions and lateral profiles in the water phantom showed good agreement with forward simulations of IAEA phase-spaces, thus supporting usage of this simulation source in the study. Measured energy-slit position maps and those obtained by forward Monte-Carlo simulations showed satisfactory agreement in shape and position. Conclusion: Well-defined electron beams of known energy and shape will provide an ideal scenario to study the performance of a novel reconstruction algorithm using measured and simulated signal. Future work will increase the stability and convergence of the reconstruction-algorithm for unknown electron sources, towards final application to the electrons which drive the interaction of TW-class laser pulses with nanometer thin target foils to accelerate protons and ions to multi-MeV kinetic energy. Cluster of Excellence of the German Research Foundation (DFG) “Munich-Centre for Advanced Photonics”.

07 ISOTOPE AND RADIATION SOURCES↗