Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Particle and crystallite size effects on the modulated structure of multiferroic CaMn{sub 7}O{sub 12}

A systematic study of the atomic position modulation in polycrystalline CaMn{sub 7}O{sub 12} with different particle sizes (determined from scanning electron microscopy) and crystallite sizes (determined from X-ray diffraction) is reported. The morphology and phase composition are characterised by scanning electron microscopy, selected area electron diffraction and energy dispersive X-ray spectroscopy. The crystal structure and the atomic position modulation in polycrystalline CaMn{sub 7}O{sub 12} samples are explored with high-resolution synchrotron radiation based powder X-ray diffraction. The modulation vector and the modulation amplitudes observed at T=10 K do not change as a function of particle size, crystallite size and microstrain fluctuations. In addition, we report and discuss the formation of the additional CaMn{sub 4}O{sub 8} nanowire phase during high temperature annealing. - Graphical abstract: The particle size morphology of the multiferroic CaMn{sub 7}O{sub 12} has a weak influence on the atomic position modulation length and the amplitude of the atomic position modulation below T=250 K. Highlights: Black-Right-Pointing-Pointer Atomic position modulation occurs in CaMn{sub 7}O{sub 12} with different particle sizes. Black-Right-Pointing-Pointer The modulation length is the same for different CaMn{sub 7}O{sub 12} particle sizes. Black-Right-Pointing-Pointer Nanowire shaped crystals of CaMn{sub 4}O{sub 8} can be synthesized.

36 MATERIALS SCIENCE↗

The 2.7 Å resolution structure of the glycopeptide sulfotransferase Teg14

The 2.7 Å resolution crystal structure of Teg14, a glycopeptide sulfotransferase cloned from an uncultured soil bacterium, is described. The relationship of Teg14 to other sulfotransferases is discussed. The TEG gene cluster was recently isolated from an environmental DNA library and is predicted to encode the biosynthesis of a polysulfated glycopeptide congener. Three closely related sulfotransferases found in the TEG gene cluster (Teg12, Teg13 and Teg14) have been shown to sulfate the teicoplanin aglycone at three unique sites. Crystal structures of the first sulfotransferase from the TEG cluster, Teg12, in complex with the teicoplanin aglycone and its desulfated cosubstrate PAP have recently been reported [Bick et al. (2010 ▶), Biochemistry, 49, 4159–4168]. Here, the 2.7 Å resolution crystal structure of the apo form of Teg14 is reported. Teg14 sulfates the hydroxyphenylglycine at position 4 in the teicoplanin aglycone. The Teg14 structure is discussed and is compared with those of other bacterial 3′-phosphoadenosine 5′-phosphosulfate-dependent sulfotransferases facilitating crystallographic experiments, especially in the field of microcrystallography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In-house synthesized poly(ether ether ketone) ionenes. I. ToF-SIMS spectra in the positive ion mode

Static time-of-flight secondary ion mass spectrometry (ToF-SIMS) was performed for acquiring the high-resolution surface spectra of four types of synthesized imidazolium ionene membranes. These novel membranes have aromatic ether–ketone–ether linkages inspired by poly(ether ether ketone) (PEEK). The PEEK-ionenes synthesized for this study have imidazolium cations placed in the polymeric backbone with bistriflimide [Tf 2 N]- counterions. The attention given to synthetically modified PEEK derivatives, such as PEEK-ionenes, is considerable due to their ability to selectively capture CO 2 molecules and other light gases. Therefore, it is important to characterize the surface of these synthesized novel PEEK-ionenes. In this work, characteristic and unique peaks were identified in the positive spectra of each sample. The differences in mass spectra among the samples provide insights for optimizing or fine-tuning the PEEK-ionenes synthesis to achieve a high-performance CO 2 separation membrane with enhanced permeability, selectivity, and mechanical stability. The SIMS spectra and identified characteristic peaks of these synthesized ionenes will serve as a reference in the positive mode, complementing the corresponding spectra reported in the negative ion mode (Paper II).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron detection efficiency of the Neutron dEtector with Xn Tracking (NEXT)

An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where β-delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) has been designed to measure β-delayed neutron emitters. By segmenting the detector along the neutron flight path, NEXT reduces the associated uncertainties in neutron time-of-flight measurements, improving energy resolution while maintaining detection efficiency. Detector prototypes are comprised of optically separated segments of a neutron-gamma discriminating plastic scintillator coupled to position-sensitive photomultiplier tubes. In this work we discuss how the first performance studies of this detector showed that high intrinsic neutron detection efficiency could be achieved while retaining good energy resolution. The results from the efficiency measurements using neutrons from direct reactions are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning for precise hit position reconstruction in Resistive Silicon Detectors

RSDs are LGAD silicon sensors with 100% fill factor, based on the principle of AC-coupled resistive read-out. Signal sharing and internal charge multiplication are the RSD key features to achieve picosecond-level time resolution and micron-level spatial resolution, thus making these sensors promising candidates as 4D-trackers for future experiments. This paper describes the use of a neural network to reconstruct the hit position of ionizing particles, an approach that can boost the performance of the RSD with respect to analytical models. The neural network has been trained in the laboratory and then validated on test beam data. The device-under-test in this work is a 450 μm-pitch matrix from the FBK RSD2 production, which achieved a resolution of about 65 μm at the DESY Test Beam Facility, a 50% improvement compared to a simple analytical reconstruction method, and a factor two better than the resolution of a standard pixel sensor of equal pitch size with binary read-out. The test beam result is compatible with the laboratory ones obtained during the neural network training, confirming the ability of the machine learning model to provide accurate predictions even in environments very different from the training one. Prospects for future improvements are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The PdBI arcsecond whirlpool survey (PAWS): Multi-phase cold gas kinematic of M51

The kinematic complexity and the favorable position of M51 on the sky make this galaxy an ideal target to test different theories of spiral arm dynamics. Taking advantage of the new high-resolution PdBI Arcsecond Whirlpool Survey data, we undertake a detailed kinematic study of M51 to characterize and quantify the origin and nature of the non-circular motions. Using a tilted-ring analysis supported by several other archival data sets, we update the estimation of M51's position angle (P.A. = (173 ± 3)°) and inclination (i = (22 ± 5)°). Harmonic decomposition of the high-resolution (∼40 pc) CO velocity field shows the first kinematic evidence of an m = 3 wave in the inner disk of M51 with a corotation at R {sub CR,} {sub m} {sub =} {sub 3} = 1.1 ± 0.1 kpc and a pattern speed of Ω {sub p,} {sub m} {sub =} {sub 3} ≈ 140 km s{sup –1} kpc{sup –1}. This mode seems to be excited by the nuclear bar, while the beat frequencies generated by the coupling between the m = 3 mode and the main spiral structure confirm its density-wave nature. We observe also a signature of an m = 1 mode that is likely responsible for the lopsidedness of M51 at small and large radii. We provide a simple method to estimate the radial variation of the amplitude of the spiral perturbation (V {sub sp}) attributed to the different modes. The main spiral arm structure has (V {sub sp}) = 50-70 km s{sup –1}, while the streaming velocity associated with the m = 1 and m = 3 modes is, in general, two times lower. Our joint analysis of H I and CO velocity fields at low and high spatial resolution reveals that the atomic and molecular gas phases respond differently to the spiral perturbation due to their different vertical distribution and emission morphology.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct Deposition of Microcolumnar Scintillator on CMOS SSPM Array: Toward a Photon Counting Detector for X-Ray/Gamma Ray Imaging

We are developing a modular, low-cost, photon-counting detector based on a scintillator coupled to a solid-state photodetector. A working prototype was successfully developed by depositing CsI:Tl directly onto a CMOS SSPM array designed by RMD and custom-fabricated by a commercial foundry. The device comprised a 6x6 array of 1.5x1.5 mm{sup 2} macro-pixels, each containing a 36x36 array of resistively coupled micro-pixels, that was subjected to vapor deposition of columnar CsI:Tl. Direct deposition eliminates the gap between the scintillator and SSPM and creates a better optical bond than does index-matching grease. This paper compares the performance of SSPMs with directly deposited CsI:Tl, in terms of signal-to-noise ratio and light spread, against devices using monolithic single crystals or pixelated single crystals coupled to the SSPM. Due to the reduction in light scattering and optical losses in the interface, the directly deposited CsI:Tl demonstrated significantly better position sensitivity, with at least a factor of 2 increase in SNR compared to a single crystal. These data indicate that a photodetector with substantially smaller macro-pixel dimensions than used here could be used to implement a low-energy X-ray/gamma-ray imaging and spectroscopy detector, particularly for applications where high resolution is of prime importance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Regional CO2 and latent heat surface fluxes in the Southern Great Plains: Measurements, modeling, and scaling

Characterizing net ecosystem exchanges (NEE) of CO{sub 2} and sensible and latent heat fluxes in heterogeneous landscapes is difficult, yet critical given expected changes in climate and land use. We report here a measurement and modeling study designed to improve our understanding of surface to atmosphere gas exchanges under very heterogeneous land cover in the mostly agricultural U.S. Southern Great Plains (SGP). We combined three years of site-level, eddy covariance measurements in several of the dominant land cover types with regional-scale climate data from the distributed Mesonet stations and Next Generation Weather Radar precipitation measurements to calibrate a land surface model of trace gas and energy exchanges (isotope-enabled land surface model (ISOLSM)). Yearly variations in vegetation cover distributions were estimated from Moderate Resolution Imaging Spectroradiometer normalized difference vegetation index and compared to regional and subregional vegetation cover type estimates from the U.S. Department of Agriculture census. We first applied ISOLSM at a 250 m spatial scale to account for vegetation cover type and leaf area variations that occur on hundred meter scales. Because of computational constraints, we developed a subsampling scheme within 10 km 'macrocells' to perform these high-resolution simulations. We estimate that the Atmospheric Radiation Measurement Climate Research Facility SGP region net CO{sub 2} exchange with the local atmosphere was -240, -340, and -270 gC m{sup -2} yr{sup -1} (positive toward the atmosphere) in 2003, 2004, and 2005, respectively, with large seasonal variations. We also performed simulations using two scaling approaches at resolutions of 10, 30, 60, and 90 km. The scaling approach applied in current land surface models led to regional NEE biases of up to 50 and 20% in weekly and annual estimates, respectively. An important factor in causing these biases was the complex leaf area index (LAI) distribution within cover types. Biases in predicted weekly average regional latent heat fluxes were smaller than for NEE, but larger than for either ecosystem respiration or assimilation alone. However, spatial and diurnal variations of hundreds of W m{sup -2} in latent heat fluxes were common. We conclude that, in this heterogeneous system, characterizing vegetation cover type and LAI at the scale of spatial variation are necessary for accurate estimates of bottom-up, regional NEE and surface energy fluxes.

54 ENVIRONMENTAL SCIENCES↗

Rapid nondestructive measurement of bacterial cultures with 3D interferometric imaging

The agar culture plate has played a crucial role in bacteriology since the origins of the discipline. However, plating, inoculating, and waiting for microbes to develop colonies that are visible is time-consuming. In this work, we explored if white-light interferometry (WLI) would be a practical tool for reducing the wait time required before colonies can be identified and counted. High resolution surface profile imaging was used for non-destructive characterization and counting of bacterial colonies on agar before they became visible to the naked eye. The three-dimensional (3D) morphology of Gram-negative ( Pseudomonas fluorescens ) and Gram-positive ( Bacillus thuringiensis ) bacterial species were visualized over time by collecting surface profiles of colonies on agar plates with high vertical resolution (3-5 nanometers) and large field of view (3-5 mm). This unique combination of sensitive vertical resolution at low magnification enabled simultaneous detection of hundreds of microcolonies. The colonies were accurately counted within the first few hours after plating with results comparing favorably to counts made by traditional methods. Since the imaging is non-destructive it was used to track single cells multiplying into small colonies and the volumetric changes in the colony were used to accurately measure colony growth rates over time. Based on the results herein, bioimaging with WLI was demonstrated as a powerful bacterial culture assay. Fast non-destructive counting of colony-forming units in a culture and simultaneous measurement of bacterial growth rates with this method suggest that it may lead to beneficial future applications in research, clinical, and other settings.

59 BASIC BIOLOGICAL SCIENCES↗

A soft x-ray beamline capable of canceling the performance impairment due to power absorbed on its optical elements

We present an entrance slitless beamline design capable of maintaining its very high performance in terms of energy resolution (>10{sup 4}) and spot size (4x4 {mu}m{sup 2}) at the sample position despite being exposed to more than 2.15 kW of undulator radiation and a maximum power density on the optics of more than 0.9 W/mm{sup 2}. Ray tracing simulations of this beamline under the worst-case thermal deformations of the optical element surfaces verify that appropriate focusing corrections are able to cancel the deleterious effects of these deformations. One of the necessary conditions for this cancellation is to illuminate the optical elements with a larger solid angle than the undulator's central cone, which contains the usable photons but is considerably smaller than the angular power distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Catalysis-dependent selenium incorporation and migration in the nitrogenase active site iron-molybdenum cofactor

Dinitrogen reduction in the biological nitrogen cycle is catalyzed by nitrogenase, a two-component metalloenzyme. Understanding of the transformation of the inert resting state of the active site FeMo-cofactor into an activated state capable of reducing dinitrogen remains elusive. Here we report the catalysis dependent, site-selective incorporation of selenium into the FeMo-cofactor from selenocyanate as a newly identified substrate and inhibitor. The 1.60 Å resolution structure reveals selenium occupying the S2B site of FeMo-cofactor in the Azotobacter vinelandii MoFe-protein, a position that was recently identified as the CO-binding site. The Se2B-labeled enzyme retains substrate reduction activity and marks the starting point for a crystallographic pulse-chase experiment of the active site during turnover. Through a series of crystal structures obtained at resolutions of 1.32–1.66 Å, including the CO-inhibited form of Av1-Se2B, the exchangeability of all three belt-sulfur sites is demonstrated, providing direct insights into unforeseen rearrangements of the metal center during catalysis.

59 BASIC BIOLOGICAL SCIENCES↗

Spectral measurements of runaway electrons by a scanning probe in the TEXTOR tokamak

Energy spectral measurements of runaway electrons were performed by a scanning probe with high spatial and temporal resolution in the TEXTOR tokamak. The probe consists of ten YSO (Y{sub 2}SiO{sub 5}:Ce) crystals, which are shielded by tungsten filters. The probe can resolve electrons with different energies between 4 and 30 MeV. An insertion of the probe to the plasma boundary several times during the discharge allowed spectral measurements of runaway electrons at different minor radial positions at the plasma edge as well as the study of runaway production in time. The high temporal resolution of the probe, 0.05 ms, enabled measurements of runaway electrons not only during low density discharges, but also during plasma disruptions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Resolution of Fast Photomultipliers for Time of Flight PET

Time resolution study of 1 inch Photonis XP1020 photomultiplier is reported. The number of photoelectrons, time jitter and time resolution with 4x4x20 mm{sup 3} LSO crystal were measured. All the mentioned PMT properties were measured at five positions on the photocathode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BREAKDOWN OF KENNICUTT-SCHMIDT LAW AT GIANT MOLECULAR CLOUD SCALES IN M33

We have mapped the northern area (30' x 20') of a Local Group spiral galaxy M33 in {sup 12}CO(J = 1-0) line with the 45 m telescope at the Nobeyama Radio Observatory. Along with H{alpha} and Spitzer 24 {mu}m data, we have investigated the relationship between the surface density of molecular gas mass and that of star formation rate (SFR) in an external galaxy (Kennicutt-Schmidt law) with the highest spatial resolution ({approx}80 pc) to date, which is comparable to scales of giant molecular clouds (GMCs). At positions where CO is significantly detected, the SFR surface density exhibits a wide range of over four orders of magnitude, from {Sigma}{sub SFR} {approx_lt} 10{sup -10} to {approx}10{sup -6} M {sub sun} yr{sup -1} pc{sup -2}, whereas the {Sigma}{sub H{sub 2}} values are mostly within 10-40 M {sub sun} pc{sup -2}. The surface density of gas and that of SFR correlate well at an {approx}1 kpc resolution, but the correlation becomes looser with higher resolution and breaks down at GMC scales. The scatter of the {Sigma}{sub SFR}-{Sigma}{sub H{sub 2}} relationship in the {approx}80 pc resolution results from the variety of star-forming activity among GMCs, which is attributed to the various evolutionary stages of GMCs and to the drift of young clusters from their parent GMCs. This result shows that the Kennicutt-Schmidt law is valid only in scales larger than that of GMCs, when we average the spatial offset between GMCs and star-forming regions, and their various evolutionary stages.

79 ASTRONOMY AND ASTROPHYSICS↗

Satellite image analysis for surveillance, vegetation and climate change

Recently, many studies have provided abundant evidence to show the trend of tree mortality is increasing in many regions, and the cause of tree mortality is associated with drought, insect outbreak, or fire. Unfortunately, there is no current capability available to monitor vegetation changes, and correlate and predict tree mortality with CO{sub 2} change, and climate change on the global scale. Different survey platforms (methods) have been used for forest management. Typical ground-based forest surveys measure tree stem diameter, species, and alive or dead. The measurements are low-tech and time consuming, but the sample sizes are large, running into millions of trees, covering large areas, and spanning many years. These field surveys provide powerful ground validation for other survey methods such as photo survey, helicopter GPS survey, and aerial overview survey. The satellite imagery has much larger coverage. It is easier to tile the different images together, and more important, the spatial resolution has been improved such that close to or even higher than aerial survey platforms. Today, the remote sensing satellite data have reached sub-meter spatial resolution for panchromatic channels (IKONOS 2: 1 m; Quickbird-2: 0.61 m; Worldview-2: 0.5 m) and meter spatial resolution for multi-spectral channels (IKONOS 2: 4 meter; Quickbird-2: 2.44 m; Worldview-2: 2 m). Therefore, high resolution satellite imagery can allow foresters to discern individual trees. This vital information should allow us to quantify physiological states of trees, e.g. healthy or dead, shape and size of tree crowns, as well as species and functional compositions of trees. This is a powerful data resource, however, due to the vast amount of the data collected daily, it is impossible for human analysts to review the imagery in detail to identify the vital biodiversity information. Thus, in this talk, we will discuss the opportunities and challenges to use high resolution satellite imagery and machine learning theory to monitor tree mortality at the level of individual trees.

47 OTHER INSTRUMENTATION↗

Use of the BrainLAB ExacTrac X-Ray 6D System in Image-Guided Radiotherapy

The ExacTrac X-Ray 6D image-guided radiotherapy (IGRT) system will be described and its performance evaluated. The system is mainly an integration of 2 subsystems: (1) an infrared (IR)-based optical positioning system (ExacTrac) and (2) a radiographic kV x-ray imaging system (X-Ray 6D). The infrared system consists of 2 IR cameras, which are used to monitor reflective body markers placed on the patient's skin to assist in patient initial setup, and an IR reflective reference star, which is attached to the treatment couch and can assist in couch movement with spatial resolution to better than 0.3 mm. The radiographic kV devices consist of 2 oblique x-ray imagers to obtain high-quality radiographs for patient position verification and adjustment. The position verification is made by fusing the radiographs with the simulation CT images using either 3 degree-of-freedom (3D) or 6 degree-of-freedom (6D) fusion algorithms. The position adjustment is performed using the infrared system according to the verification results. The reliability of the fusion algorithm will be described based on phantom and patient studies. The results indicated that the 6D fusion method is better compared to the 3D method if there are rotational deviations between the simulation and setup positions. Recently, the system has been augmented with the capabilities for image-guided positioning of targets in motion due to respiration and for gated treatment of those targets. The infrared markers provide a respiratory signal for tracking and gating of the treatment beam, with the x-ray system providing periodic confirmation of patient position relative to the gating window throughout the duration of the gated delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

MULTI-COMPONENT ANALYSIS OF POSITION-VELOCITY CUBES OF THE HH 34 JET

We present an analysis of H{alpha} spectra of the HH 34 jet with two-dimensional spectral resolution. We carry out multi-Gaussian fits to the spatially resolved line profiles and derive maps of the intensity, radial velocity, and velocity width of each of the components. We find that close to the outflow source we have three components: a high (negative) radial velocity component with a well-collimated, jet-like morphology; an intermediate velocity component with a broader morphology; and a positive radial velocity component with a non-collimated morphology and large linewidth. We suggest that this positive velocity component is associated with jet emission scattered in stationary dust present in the circumstellar environment. Farther away from the outflow source, we find only two components (a high, negative radial velocity component, which has a narrower spatial distribution than an intermediate velocity component). The fitting procedure was carried out with the new AGA-V1 code, which is available online and is described in detail in this paper.

79 ASTRONOMY AND ASTROPHYSICS↗