Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Susceptibility to polarization type potential induced degradation in commercial bifacial p-PERC PV modules

Potential induced degradation (PID) is a reliability issue affecting photovoltaic (PV) modules, mainly when PV strings operate under high voltages in hot/humid conditions. Polarization-type PID (PID-p) has been known to decrease module performance quickly. PID-p can be reduced or recovered under the light in some cases, but this effect, as expected, would be less pronounced on the rear side of bifacial PV modules receiving lower irradiance. As bifacial PV modules are projected to dominate the PV market within the next 10 years, it is crucial to understand the PID-p issue in bifacial modules better. In this study, we performed indoor PID testing to induce PID-p on 14 commercial bifacial p-PERC modules with three different module constructions from three manufacturers. Here, four rounds (+ve and –ve polarities for front and rear sides) of PID testing are done at 25°C, 54% relative humidity (RH) for 168 h using the aluminum foil method. Each module side (front cell side and back cell side) is tested individually under both negative and positive voltage bias. The results show that the highest degradation of 32% in maximum power (Pmax) at standard test conditions (1000 W/m 2 ) and 51% at low irradiance (200 W/m 2 ) has been observed in some cases. Recovery under sunlight is also done, and outcomes show a near-complete recovery in Pmax. This study presents an extensive experimental methodology and a detailed analysis to systematically and simultaneously/sequentially evaluate multiple construction types of bifacial modules to the PID-p susceptibility and recovery.

14 SOLAR ENERGY↗

Distortion of power law blinking with binning and thresholding

Fluorescence intermittency is a random switching between emitting (on) and non-emitting (off) periods found for many single chromophores such as semiconductor quantum dots and organic molecules. The statistics of the duration of on- and off-periods are commonly determined by thresholding the emission time trace of a single chromophore and appear to be power law distributed. Here we test with the help of simulations if the experimentally determined power law distributions can actually reflect the underlying statistics. We find that with the experimentally limited time resolution real power law statistics with exponents α{sub on/off} ≳ 1.6, especially if α{sub on} ≠ α{sub off} would not be observed as such in the experimental data after binning and thresholding. Instead, a power law appearance could simply be obtained from the continuous distribution of intermediate intensity levels. This challenges much of the obtained data and the models describing the so-called power law blinking.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Summary of Factory Fueling and Testing Risks to Support the Transformation of Regulatory Requirements for Microreactors

Microreactors have the potential to open new markets and applications for nuclear energy. New manufacturing and operational regimes, such as factory fueling and testing prior to site installation, are being proposed to meet these new markets. The radiological hazards associated with traditional commercial power reactors are not the same as the hazards of a reactor being constructed in a factory. Currently, a reactor operating license specified under 10 CFR Part 50, Part 52, or (in the near future) Part 53 is required prior to loading fuel in the reactor. This is logical for plants that are immediately to begin full-power operations soon after fuel loading. However, for microreactors, this may not be the case. Some deployment concepts may stage reactors as “ready to go” in a factory prior to site installation and startup. This approach is being considered in the case of diesel generator replacements, mobile or roaming mining operations, and emergency response situations, such as after a major disaster event. Therefore, it is necessary to evaluate hazards assuming low power operation for a short irradiation time. This report investigates the primary hazards unique to microreactors associated with low power reactor and physics tests necessary to confirm core safety assumptions, neutronic and core design performance parameters, and other assumptions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving the Accuracy of PCMI Simulations with More Realistic Geometry and Material Models

Assessment of fuel performance codes is an endeavour that requires re-evaluation as new simulation capabilities become available. BISON, the finite element-based fuel performance code in development at Idaho National Laboratory, has been used to simulate a variety of experiments. Calculations from these simulations are compared to experimental measurements for the purpose of evaluating the progress of code development. One such experiment, from the Risø 3 Fission Gas Project, provides measurements of fission gas release and clad diameter. A subset of the Risø3 Fission Gas Project, which is referred to here, consisted of a base-irradiation period of a full-length fuel rod in the Quad-Cities-1 BWR. The base irradiation test was followed by a “bump test”, in which a sub-section of the original rod was subjected to a strongly non-uniform axial power profile. The bump test took place in Risø test reactor DR3 in a water-cooled HP1 rig under BWR conditions. This experiment was chosen because it allows for an evaluation of several aspects of BISON, including fully coupled thermo-mechanics, contact, and several nonlinear material models. A summary of simulation results and comparison to the experiment data has been published previously, however, this paper shows new results with recently added features to BISON. These new features include representing the pellets as discrete entities rather than a smeared column, including primary creep in the clad creep model, and the coupling of fuel gaseous swelling to fission gas release. Comparing to previous results, the addition of theses features has narrowed the gap between BISON calculations and experimental measurements for final clad diameter and fission gas release.

99 GENERAL AND MISCELLANEOUS↗

Performance of Oak Ridge National Laboratory spallation neutron source proton power upgrade cavities and cryomodule production

The Proton Power Upgrade initiative at Oak Ridge National Lab’s Spallation Neutron Source aims to greatly boost the capability of proton beam power. This upgrade involves the integration of seven additional cryomodules, each housing four six-cell high-beta ( β = 0.81 ) superconducting radio frequency cavities. These cavities, manufactured and processed by Research Instruments in Germany, underwent meticulous treatment, including electropolishing as the bulk and final vital step. Upon delivery to Jefferson Lab, a total of 28 cavities for seven cryomodules, along with an additional four cavities for a spare cryomodule, underwent thorough vertical qualification tests, meeting the required specifications. Following cavity tanking and subsequent rf testing, the assembly of eight cryomodules was successfully executed, with all 32 cavities demonstrating compliance with acceptance criteria. The transportation of the cryomodule to SNS for high-power testing in the tunnel yielded exceptional results. Notably, the performance surpassed specifications, in terms of quality factor and accelerating gradient. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Engineering-Scale Test of a Water-Lean Solvent for Post-Combustion Capture

EPRI, Pacific Northwest National Laboratory, RTI International, and their project collaborators developed an engineering-scale test of a new water-lean solvent, N-(2-ethoxyethyl)-3-morpholinopropan-1-amine (EEMPA or 2-EEMPA) as a post-combustion CO 2 capture solvent for power plant applications. This test was conducted using the Pilot Solvent Test Unit at the National Carbon Capture Center. The primary objective of this test was to collect long-term data operating EEMPA with both coal- and natural gas-representative flue gases at the approximately 0.5 MW e -equivalent scale (5–10 metric tons CO 2 /day captured). This report details the activities preparing for that test, data collected during the test campaign, and analyses and interpretations of that data.

20 FOSSIL-FUELED POWER PLANTS↗

Test of a Novel, Commercial-Scale Wave Energy Direct-Drive Rotary Power Take-Off at the NREL National Wind Technology Center (CRADA CRD-14-571 Final Report)

The National Renewable Energy Laboratory (NREL) will work with Columbia Power Technologies [C-Power] to support work under US DOE DE-EE-0006399, “Build and Test of a Novel, Commercial-Scale Wave Energy Direct-Drive Rotary Power Take-Off Under Realistic Open-Ocean Conditions.” Work will include a review of their design for a novel wave energy direct drive generator. After review, the system will be prototyped and tested in the NREL National Wind Technology Center (NWTC) 5MW dynamometer and data will be recorded and analyzed. Conclusions from data analysis will be used to improve the design prior to completing a version of the system for ocean deployment. Additionally, NREL will work with Columbia Power Technologies [C-Power] to quantify the system levelized cost of energy (LCOE) and analyze the system in agreement with US DOE System Performance Advancement (SPA) goals 1 and 2.

16 TIDAL AND WAVE POWER↗

Wave energy converter buoy for Arctic observations

Ocean observation buoys are currently powered-constrained by battery storage capacity or available solar power. Power constraints limit the number of measurements that can be made and the lifetime of the buoys. Ocean surface wave energy could be used for power production, but wave energy converters are not yet commercially available for ocean observation buoys. Here we present the design and testing of a drifting wave energy converter buoy using a pendulum transmission system (PTS). The wave energy converter buoy was designed to operate in Arctic temperatures and wave conditions, but it could be used in areas with warmer temperatures and larger waves. Field tests measured a maximum power production of 5 watts in waves with a significant wave height of 0.42 meters and a ten minute average power production of 37 milliwatts. Power production increased with the energy period and significant wave height. The energy harvesting capabilities of the PTS showed the utility of adding a wave energy conversion device to a drifting ocean observation buoy.

Arctic observations↗

Measuring the power spectrum of dark matter substructure using strong gravitational lensing

In recent years, it has become possible to detect individual dark matter subhalos near images of strongly lensed extended background galaxies. Typically, only the most massive subhalos in the strong lensing region may be detected this way. In this work, we show that strong lenses may also be used to constrain the much more numerous population of lower mass subhalos that are too small to be detected individually. In particular, we show that the power spectrum of projected density fluctuations in galaxy halos can be measured using strong gravitational lensing. We develop the mathematical framework of power spectrum estimation, and test our method on mock observations. We use our results to determine the types of observations required to measure the substructure power spectrum with high significance. We predict that deep observations (∼10 hours on a single target) with current facilities can measure this power spectrum at the 3σ level, with no apparent degeneracy with unknown clumpiness in the background source structure or fluctuations from detector noise. Upcoming ALMA measurements of strong lenses are capable of placing strong constraints on the abundance of dark matter subhalos and the underlying particle nature of dark matter.

79 ASTRONOMY AND ASTROPHYSICS↗

Hyper Suprime-Cam Year 3 results: Cosmology from cosmic shear power spectra

Here, we measure weak lensing cosmic shear power spectra from the 3-year galaxy shear catalog of the Hyper Suprime-Cam (HSC) Subaru Strategic Program imaging survey. The shear catalog covers 416 deg 2 of the northern sky, with a mean i-band seeing of 0.59 arcsec and an effective galaxy number density of 15 arcmin —2 within our adopted redshift range. With an i-band magnitude limit of 24.5 mag, and four tomographic redshift bins spanning 0.3 ≤ z ph ≤ 1.5 based on photometric redshifts, we obtain a high-significance measurement of the cosmic shear power spectra, with a signal-to-noise ratio of approximately 26.4 in the multipole range 300 < ℓ < 1800. The accuracy of our power spectrum measurement is tested against realistic mock shear catalogs, and we use these catalogs to get a reliable measurement of the covariance of the power spectrum measurements. We use a robust blinding procedure to avoid confirmation bias, and model various uncertainties and sources of bias in our analysis, including point spread function systematics, redshift distribution uncertainties, the intrinsic alignment of galaxies and the modeling of the matter power spectrum. For a flat Λ CDM model, we find S 8 ≡ σ 8 (Ω m /0.3) 0.5 = ${0.776}_{—0.033}^{+0.032}$, which is in excellent agreement with the constraints from the other HSC Year 3 cosmology analyses, as well as those from a number of other cosmic shear experiments. This result implies a ~2σ-level tension with the Planck 2018 cosmology. We study the effect that various systematic errors and modeling choices could have on this value, and find that they can shift the best-fit value of S 8 by no more than ~ 0.5σ, indicating that our result is robust to such systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance Analysis of a Biomass Gasifier Genset at Varying Operating Conditions

Abstract. An All Power Labs PP20 gasifier generation set (Berkeley, Calif.) was tested to evaluate its suitability for powering biomass conversion technologies (BCT) at remote forest operations sites. Feedstock of the species tanoak (), coast redwood (), and Douglas fir () were tested at moisture contents of 15% and 25% (wet basis). The PP20 was connected to a load bank with five different load profiles designed to simulate possible BCT loads. Two parameters of power quality, voltage variability, and frequency deviation, were determined to be within acceptable limits. The unit also successfully powered a remote biochar operation in Branscomb, California. Emissions of the PP20, when compared to diesel generator regulations, would meet non-methane hydrocarbons (NMHC) and NO X requirements but exceed the CO emissions limits by a factor of ten. The CO emissions could be reduced by adding a catalytic converter. The results indicate that it is possible to use a PP20 unit to provide electric power for the highly variable loads of a BCT system. Keywords: Bioenergy, Biomass conversion technology, Gasification, Renewable energy.

Agriculture↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗

A UVLO Circuit in SiC Compatible With Power MOSFET Integration

The design and test of the first undervoltage lock-out circuit implemented in a low-voltage 4H silicon carbide process capable of single-chip integration with power MOSFETs is presented. The lock-out circuit, a block of the protection circuitry of a single-chip gate driver topology designed for use in a plug-in hybrid vehicle charger, was demonstrated to have rise/fall times compatible with a MOSFET switching speed of 250 kHz while operating over the targeted operating temperature range between 0°C and 200°C. Captured data show the circuit to be functional over a temperature range from -55°C to 300°C. The design of the circuit and test results is presented.

Glover, Michael D.↗

Establishment of a PID Pass/Fail Test for Crystalline Silicon Modules by Examining Field Performance for Five Years: Preprint

In an experiment with five module designs and multiple replicas, it is found that crystalline silicon cell modules that can pass a criterion of less than 5 percent power degradation in stress test conditions of 60 degrees Celsius, 85 percent relative humidity (RH), 96 h, and nameplate-rated system voltage bias show no power degradation by potential induced degradation in the range of 4-6 years duration in the Florida, USA environment. This data suggests that this chamber stress level is useful as a pass/fail criterion for PID, and will help ensure against degradation by system voltage stress in Florida, or less stressful climates, for at least 5 years.

14 SOLAR ENERGY↗

Design and Validation of A 250-kW All-Silicon Carbide High-Density Three-Level T-Type Inverter

Our article introduces a comprehensive design and validation of a compact all-silicon carbide (SiC) 250-kW T-type traction inverter with a power density of 25 kW/l and 98.5% peak efficiency. All the operation modes and switching transitions in a T-type phase leg are analyzed to model the semiconductor power losses over a fundamental cycle. Special attention has been paid to explore the behavior and losses due to the reverse conduction of the SiC MOSFETs. Then a loss model is built based upon this analysis to calculate the device loss distribution and system efficiency, which is further used to determine the optimal switching frequency. In addition, detailed inverter system design and prototyping procedure, including the selection of SiC modules and dc-link capacitors, and the optimization of a fourlayer laminated busbar, are presented. In this article, the T-type phase leg is formed by a normal half-bridge module and a common-source module. The switching performance and losses in this configuration are different from two-level topology that only uses one SiC module. Thus, the switching performance and the associated switching energy in each switch position are characterized using a custom clamped inductive load (CIL) test setup designed for a T-type phase leg. The performance of the full power traction inverter prototype has been verified experimentally using pulse testing and continuous power testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗