Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Methanogens: Syntrophic Metabolism

Syntrophy is a mutualistic interaction in which two metabolically different types of microorganisms are linked by the need to keep metabolites exchanged between the two partners at low concentrations to make the overall metabolism of both organisms feasible. In most cases, the cooperation is based on the transfer of hydrogen, formate, or acetate from fermentative bacteria to methanogens to make the degradation of electron-rich substrates thermodynamically favorable. Syntrophic metabolism proceeds at very low Gibbs’ free energy changes, close to the minimum free energy change needed to conserve energy biologically, which is the energy needed to transport one proton across the cytoplasmic membrane. Pathways for syntrophic degradation of fatty acids predict the net synthesis of about one-third of an ATP per round of catabolism. Syntrophic metabolism entails critical oxidation-reduction reactions in which H 2 or formate production would be thermodynamically unfavorable unless energy is invested. Molecular insights into the membrane processes involved in ion translocation and reverse electron transport revealed that syntrophs harbour multiple systems for reverse electron transfer. While much evidence supports the interspecies transfer of H 2 and formate, other mechanisms of interspecies electron transfer exist including cysteine cycling and possibly direct interspecies electron transfer as electric current via conductive pili or (semi)conductive minerals.

59 BASIC BIOLOGICAL SCIENCES↗

Two-particle angular correlations in e + e - collisions to hadronic final states in two reference coordinates at Belle

We present the analysis of two-particle angular correlations using coordinate systems defined with the conventional beam axis and the event thrust axis. We propose the latter as a good representation for the correlation structure interpretation in the e + e - collision system. The e + e - collisions to hadronic final states at center-of-mass energies of $\sqrt{s}$ = 10.52 GeV and 10.58 GeV are recorded by the Belle detector at KEKB. In this paper, results on the first dataset are supplementary to the previous Belle publication [1]. At the same time, the latter is the first two-particle correlation measurement at collision energy on the Υ(4S) resonance and is sensitive to its decay products. Measurements are reported as a function of the charged-particle multiplicity. Finally, a qualitative understanding of the correlation structure is discussed using a combination of Monte Carlo simulations and experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characteristics of missed prostate cancer lesions on 3T multiparametric-MRI in 518 patients: based on PI-RADSv2 and using whole-mount histopathology reference

Purpose: To determine the characteristics of missed prostate cancer (PCa) lesions on 3T multiparametric-MRI (mpMRI) based on PI-RADSv2 with whole-mount histopathology (WMHP) correlation. Materials and methods: This IRB-approved, HIPAA-compliant study, included 614 consecutive men with 3T mpMRI prior to prostatectomy at a single tertiary center between 12/2009 and 4/2017. Clinical, mpMRI, and pathologic features were obtained. PI-RADSv2-based MRI detected lesions were matched with previously finalized WMHP by a genitourinary (GU) radiologist and a GU pathologist. Patients with no mpMRI detected PCa lesion, but with at least one lesion ≥ 1 cm on WMHP, were reviewed retrospectively and assigned a PI-RADSv2 score. Tumor characteristics were compared between missed and detected lesions. Result: The final cohort included 518 patients with 1085 WMHP lesions. 51.9% (563/1085) of lesions were missed on 3T mpMRI. 71.4% (402/563), 21.7% (122/563), 4.4% (25/563), and 2.5% (14/563) of the missed lesions were Gleason scores (GS) 3 + 3, 3 + 4, 4 + 3, and 8 − 10, respectively. Missed PCa lesions had significantly lower proportion of GS ≥ 7 (p < 0.001) and smaller size for overall (p < 0.001) and index subcohorts (p < 0.001), as compared to detected lesions. 34.5% (194) of overall and 71.2% (79) index missed lesions were larger than 1 cm. In 13.7% (71/518) of patients without MR detected PCa, 149 lesions were detected on WMHP, with 70 (47%) lesions ≥ 1 cm. In retrospective review of these lesions, 42.9% (30), 18.6% (13), 21.5% (15), 10% (7), and 7% (5) were PI-RADSv2 1, 2, 3, 4, and 5, respectively. Conclusion: 3T mpMRI has an excellent per patients diagnostic performance for PCa and majority of missed lesions are clinically nonsignificant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differentiating IgG4-related sclerosing cholangiopathy from cholangiocarcinoma using CT and MRI: experience from a tertiary referring center

Purpose: To compare the cross-sectional imaging findings of immunoglobulin G4-related sclerosing cholangiopathy (IgG4-SC) and cholangiocarcinoma (CCA). Methods: Retrospective search of radiology and pathology databases identified 24 patients with IgG4-SC and over 500 patients with CCA from January 2009 to December 2016. Patients with no pre-treatment imaging studies available on PACS, non-contrasted imaging only, presence of mass lesions, metastatic disease or biliary stents were excluded. 17 patients with IgG4-SC and a selected group of 20 (age and gender matched) patients with CCA were obtained. Images were blinded and independently reviewed by two radiologists. Differences in proportions and means between groups were analyzed using Fishers and Mann–Whitney tests, respectively. Results: Both readers identified a statistically significant difference in the presence of abrupt common bile duct narrowing between IgG4-SC and CCA (6.7% vs. 68.4%, p < 0.001; 33.3% vs. 75%, p = 0.019). No difference was seen in biliary wall thickening, wall enhancement, extrahepatic exclusive location of disease, or pancreatic duct dilation. Inter-observer variability was κ = 0.52. Total bilirubin and CA 19-9 were unable to differentiate between IgG4-SC and CCA. Serum IgG4 was positive in two of six IgG4-SC patients who were tested. Conclusion: IgG4-SC and CCA share many clinical and imaging findings on CT and MRI. Abrupt bile duct cut sign strongly favors CCA. In the absence of this finding, IgG4-SC should be considered in the differential diagnosis in all cases of suspected extrahepatic CCA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IR Thermographic Analysis of 3D Printed CFRP Reference Samples with Back-Drilled and Embedded Defects

Carbon-fiber composite structures may demonstrate a defective behavior due to manufacturing induced anomalies (delamination, dis-bonds) or service related defectives (impact damage, water ingress). Thus, there is a need for a relatively fast and low cost non-intrusive testing schemes such as infrared thermography (IRT). Still, thermography testing requires calibrated samples and coupons to yield best results. The presented research demonstrates the novel use of 3D printing technology to generate IRT calibration samples. In this text, two carbon fiber reinforced polymer samples are 3D printed; the first mimics a 'back-drilled holes' type coupons, while the other is designed to embed air pockets similar to Teflon inserts. The generated samples are then tested using two IRT modalities; namely pulse thermography and lock-in thermography. Furthermore, the resulted thermograms are processed using a principle component analysis, to help highlight the variance of defectives in a consistent manner among the samples. This research findings offer insights on the variation of detectability between embedded and back-printed samples, which might be due to the inserts thickness.

36 MATERIALS SCIENCE↗