Search NASA⌕ Search

SEARCH · Search NASA

Results for “Repeatability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Periodic Fast Radio Bursts from Young Neutron Stars

Fast radio bursts (FRBs) are highly energetic radio pulses from cosmological origins. Despite an abundance of detections, their nature remains elusive. At least a subset of FRBs is expected to repeat, as the volumetric FRB rate surpasses that of any known cataclysmic event, which has been confirmed by observations. One of the proposed mechanisms to generate repeating FRBs is supergiant pulses from young and highly spinning neutron stars (NSs), in which case FRBs could inherit the periodicity of their parent NS. Here we examine the consequences of such a population of periodic fast radio bursts (PFRBs). We calculate the rate and lifetime of PFRB progenitors, and find that each newly born highly spinning NS has to emit a number ${N}_{\mathrm{PFRB}}\sim {10}^{2}$ of detectable bursts during its active lifetime of $\tau \sim 100$ yr, after which it becomes too dim and crosses a PFRB "death line" analogous to the pulsar one. We propose several tests of this hypothesis. First, the period of PFRBs would increase over time, and their luminosity would decrease, due to the NS spin-down. Second, PFRBs may show modest amounts of rotation measure, given the lack of expelled matter from the pulsar, as opposed to the magnetar-sourced FRBs proposed to explain the first repeater FRB 121102. As an example, we study whether the second confirmed repeater (FRB 180814) is a PFRB, given the preference for an inter-pulse separation of 13 ms within its sub-bursts. We show that, if confirmed, this period would place FRB 180814 in a different category as FRB 121102. We develop tests that would identify—and characterize—the prospective population of PFRBs.

79 ASTRONOMY AND ASTROPHYSICS↗

Orbit selection considerations for earth observatory satellites

All the possible circular sun-synchronous orbits for earth observatory satellites are displayed, which have orbital altitudes between 740 and 1,115 kilometers (approximately 400 to 600 nautical miles) and have either a 16, 17, or 18 day repeat cycle for the ground trace. It was found that there are 9 orbits with a 16 day repeat cycle, 17 orbits with a 17 day repeat cycle, and 7 orbits with an 18 day repeat cycle meeting the requirements. For each of these, various characteristics such as ideal ground trace patterns, swathing patterns, and daily drift are displayed. The solar elevation angle along the orbit and the change in the solar elevation angle with season are given. This presentation of general orbital characteristics has application to finding approximate orbital elements and selecting orbits for many types of earth sensing satellite missions.

Cooley, J. L.↗

Performance analysis of wideband data and television channels

Several aspects are discussed of space shuttle communications, including the return link (shuttle-to-ground) relayed through a satellite repeater (TDRS). The repeater exhibits nonlinear amplification and an amplitude-dependent phase shift. Models were developed for various link configurations, and computer simulation programs based on these models are described. Certain analytical results on system performance were also obtained. For the system parameters assumed, the results indicate approximately 1 db degradation relative to a link employing a linear repeater. While this degradation is dependent upon the repeater, filter bandwidths, and modulation parameters used, the programs can accommodate changes to any of these quantities. Thus the programs can be applied to determine the performance with any given set of parameters, or used as an aid in link design.

Geist, J. M.↗

Time code dissemination experiment via the SIRIO-1 VHF transponder

An experiment to evaluate the possibility of disseminating a time code via the SIRIO-1 satellite, by using the onboard VHF repeater is described. The precision in the synchronization of remote clocks was expected to be of the order of 0.1 to 1 ms. The RF carrier was in the VHF band, so that low cost receivers could be used and then a broader class of users could be served. An already existing repeater, even if not designed specifically for communications could be utilized; the operation of this repeater was not intended to affect any other function of the spacecraft (both the SHF repeater and the VHF telemetry link were active during the time code dissemination via the VHF transponder).

Detoma, E.↗

Study of communications data compression methods

A simple monochrome conditional replenishment system was extended to higher compression and to higher motion levels, by incorporating spatially adaptive quantizers and field repeating. Conditional replenishment combines intraframe and interframe compression, and both areas are investigated. The gain of conditional replenishment depends on the fraction of the image changing, since only changed parts of the image need to be transmitted. If the transmission rate is set so that only one fourth of the image can be transmitted in each field, greater change fractions will overload the system. A computer simulation was prepared which incorporated (1) field repeat of changes, (2) a variable change threshold, (3) frame repeat for high change, and (4) two mode, variable rate Hadamard intraframe quantizers. The field repeat gives 2:1 compression in moving areas without noticeable degradation. Variable change threshold allows some flexibility in dealing with varying change rates, but the threshold variation must be limited for acceptable performance.

Jones, H. W.↗

The Spring 1985 high precision baseline test of the JPL GPS-based geodetic system

The Spring 1985 High Precision Baseline Test (HPBT) was conducted. The HPBT was designed to meet a number of objectives. Foremost among these was the demonstration of a level of accuracy of 1 to 2:10 to the 7th power, or better, for baselines ranging in length up to several hundred kilometers. These objectives were all met with a high degree of success, with respect to the demonstration of system accuracy in particular. The results from six baselines ranging in length from 70 to 729 km were examined for repeatability and, in the case of three baselines, were compared to results from colocated VLBI systems. Repeatability was found to be 5:10 to the 8th power (RMS) for the north baseline coordinate, independent of baseline length, while for the east coordinate RMS repeatability was found to be larger than this by factors of 2 to 4. The GPS-based results were found to be in agreement with those from colocated VLBI measurements, when corrected for the physical separations of the VLBI and CPG antennas, at the level of 1 to 2:10 to the 7th power in all coordinates, independent of baseline length. The results for baseline repeatability are consistent with the current GPA error budget, but the GPS-VLBI intercomparisons disagree at a somewhat larger level than expected. It is hypothesized that these differences may result from errors in the local survey measurements used to correct for the separations of the GPS and VLBI antenna reference centers.

Davidson, John M.↗

On the eigenvalue and eigenvector derivatives of a non-defective matrix

A novel approach is introduced to address the problem of existence of differentiable eigenvectors for a nondefective matrix which may have repeated eigenvalues. The existence of eigenvector derivatives for a unique set of continuous eigenvectors corresponding to a repeated eigenvalue is rigorously established for nondefective and analytic matrices. A numerically implementable method is then developed to compute the differentiable eigenvectors associated with repeated eigenvalues. The solutions of eigenvalue and eigenvector derivatives for repeated eigenvalues are then derived. An example is given to illustrate the validity of formulations developed in this paper.

Juang, Jer-Nan↗

A menu of self-administered microcomputer-based neurotoxicology tests

This study examined the feasibility of repeated self-administration of a newly developed battery of mental acuity tests. Researchers developed this battery to be used to screen the fitness for duty of persons in at-risk occupations (astronauts, race car drivers), or those who may be exposed to environmental stress, toxic agents, or disease. The menu under study contained cognitive and motor tests implemented on a portable microcomputer including: a five-test core battery, lasting six minutes, which had demonstrable reliabilities and stability from several previous repeated-measures studies, and also 13 new tests, lasting 42 minutes, which had appeared in other batteries but had not yet been evaluated for repeated-measures implementation in this medium. Sixteen subjects self-administered the battery over 10 repeated sessions. The hardware performed well throughout the study and the tests appeared to be easily self-administered. Stabilities and reliabilities of the test from the core battery were comparable to those obtained previously under more controlled experimental conditions. Analyses of metric properties of the remaining 13 tests produced eight additional tests with satisfactory properties. Although the average retest reliability was high, cross-correlations between tests were low, indicating factorial richness. The menu can be used to form batteries of flexible total testing time which are likely to tap different mental processes and functions.

Kennedy, Robert S.↗

Few millimeter precision for baselines in the California Permanent GPS Geodetic Array

Geodetic measurements with Rogue GPS receivers from sites in the California Permanent GPS geodetic Array (PGGA) have been analyzed using the GIPSY orbit-determination and baseline-estimation software. Based on an unbiased selection of 23 daily measurements spanning 8 months, the LF contributions to the long-term repeatabilities of baseline measurements are approximately 5, 3, and 8 mm for the east, north, and vertical components. Short-term contributions to the long-term repeatabilities were evaluated by examining data from the week of October 21, 1990, which showed the lowest short-term scatter. For this week, daily repeatabilities of 2-3 mm in the horizontal and 4 mm in the vertical have been achieved for the 172-km JPL-Pinyon baseline, consistent with carrier phase date noise of about 6 mm. High quality (less than about 5 mm) repeatabilities have been achieved for all components of the other baselines as well.

Lindqwister, Ulf J.↗

Results of an Icing test on a NACA 0012 airfoil in the NASA Lewis Icing Research Tunnel

Tests were conducted in the Icing Research Tunnel (IRT) at the NASA Lewis Research Center to document the current capability of the IRT, focused mainly on the repeatability of the ice shape over a range of icing conditions. Measurements of drag increase due to the ice accretion were also made to document the repeatability of drag. Surface temperatures of the model were obtained to show the effects of latent-heat release by the freezing droplets and heat transfer through the ice layer. The repeatability of the ice shape was very good at low temperatures, but only fair at near freezing temperatures. In general, drag data shows good repeatability.

Shin, Jaiwon↗

Results of an icing test on a NACA 0012 airfoil in the NASA Lewis Icing Research Tunnel

Tests were conducted in the Icing Research Tunnel (IRT) at the NASA Lewis Research Center to document the current capability of the IRT, focused mainly on the repeatability of the ice shape over a range of icing conditions. Measurements of drag increase due to the ice accretion were also made to document the repeatability of drag. Surface temperatures of the model were obtained to show the effects of latent-heat release by the freezing droplets and heat transfer through the ice layer. The repeatability of the ice shape was very good at low temperatures, but only fair at near freezing temperatures. In general, drag data shows good repeatability.

Shin, Jaiwon↗

Development of electrochemical super capacitors for EMA applications

In a NASA SBIR Phase I program (Contract No. NAS8-40119), Giner, Inc. evaluated the feasibility of fabricating an all-solid-ionomer multicell electrochemical capacitor having a unit cell capacitance greater than 2 F/sq cm and a repeating element thickness of 6 mils. This capacitor can possibly be used by NASA as a high-rate energy source for electromechanical actuator (EMA) activation for advanced space missions. The high unit cell capacitance and low repeating element thickness will allow for the fabrication of a low-volume, low-weight device, favorable characteristics for space applications. These same characteristics also make the capacitor attractive for terrestrial applications, such as load-leveling batteries or fuel cells in electric vehicle applications. Although the projected energy densities for electrochemical capacitors are about two orders of magnitude lower than that of batteries, the high-power-density characteristics of these devices render them as potentially viable candidates for meeting pulse or peak electrical power requirements for some anticipated aerospace mission scenarios, especially those with discharge times on the millisecond to second time scale. On a volumetric or gravimetric basis, the advantages of utilizing electrochemical capacitors rather than batteries for meeting the peak power demands associated with a specific mission scenario will largely depend upon the total and pulse durations of the power peaks. The effect of preparation conditions on RuO(x), the active component in an all-solid-ionomer electrochemical capacitor, was evaluated during this program. Methods were identified to prepare RuO(x) having a surface areagreater than 180 sq m/g, and a capacitance of greater than 2 F/sq cm. Further efforts to reproducibly obtain these high-surface-area materials in scaled-up batches will be evaluated in Phase 2. During this Phase 1 program we identified a superior Nafion 105 membrane, having a film thickness of 5 mils, that showed excellent performance in our all-solid-ionomer capacitors and resulted in electrochemical capacitors with a repeating element thickness of 8 mils. We are currently working with membrane manufacturers to obtain a high performance membrane in less than 3 mil thickness to obtain a repeating element thickness of 6 mils or less. A 10-cell all-solid ionomer capacitor stack, with each cell having a 222 sq cm active area, was fabricated and evaluated as part of the Phase 1 program. Further Scale-up of a high-energy-density stack is plannedin Phase 2.

Kosek, J. A.↗

3D Structured Grid Adaptation

Grid adaptation for structured meshes is the art of using information from an existing, but poorly resolved, solution to automatically redistribute the grid points in such a way as to improve the resolution in regions of high error, and thus the quality of the solution. This involves: (1) generate a grid vis some standard algorithm, (2) calculate a solution on this grid, (3) adapt the grid to this solution, (4) recalculate the solution on this adapted grid, and (5) repeat steps 3 and 4 to satisfaction. Steps 3 and 4 can be repeated until some 'optimal' grid is converged to but typically this is not worth the effort and just two or three repeat calculations are necessary. They also may be repeated every 5-10 time steps for unsteady calculations.

Banks, D. W.↗

Improved Limits on Gamma-Ray Burst Repetition from BATSE

We tighten previous upper limits on gamma-ray burst repetition by analyzing the angular power spectrum of the BATSE 3B catalog of 1122 bursts. At 95% confidence, we find that no more than 2% of all observed bursts can be labeled as repeaters, even if no sources are observed to repeat more than once. If a fraction f of all observed bursts can be labeled as repeaters that are observed to burst upsilon times each, then all models with (upsilon - 1)f greater than or equal to 0.05 are ruled out at 99% confidence, as compared to the best previous 99% limit (upsilon - 1)f greater than or equal to 0.27. At 95% confidence, our new limit is (upsilon - 1)f greater than or equal to 0.02. Thus, even a cluster of six events from a single source would have caused excess power above that present in the 3B catalog. We conclude that the current BATSE data are consistent with no repetition of classical gamma-ray bursts and that any repeater model is severely constrained by the near-perfect isotropy of their angular distribution.

Tegmark, Max↗

Improved Limits on Gamma-Ray Burst Repetition from BATSE

We tighten previous upper limits on gamma-ray burst repetition by analyzing the angular power spectrum of the BATSE 3B catalog of 1122 bursts. At 95% confidence, we find that no more than 2% of all observed bursts can be labeled as repeaters, even if no sources are observed to repeat more than once. If a fraction f of all observed bursts can be labeled as repeaters that are observed to burst nu times each, then all models with (nu - 1)f greater than or equal to 0.05 are ruled out at 99% confidence, as compared to the best previous 99% limit (nu - 1)f greater than or equal to 0.27. At 95% confidence, our new limit is (nu - 1)f greater than or equal to 0.02. Thus, even a cluster of six events from a single source would have caused excess power above that present in the 3B catalog. We conclude that the current BATSE data are consistent with no repetition of classical gamma-ray bursts and that any repeater model is severely constrained by the near-perfect isotropy of their angular dis- tribution.

Tegmark, Max↗

Impact of Eccentricity on East-west Stationkeeping for GPS Class of Orbits

There exists a strong relationship between eccentricity and the potential for a repeating groundtrack orbit to exhibit chaotic motion. This is true at all values of eccentricity, but, perhaps most dramatic, is that it is true even for orbits that are nearly circular. These complex motions can have a significant impact on the east-west stationkeeping process for maintaining the repeating groundtrack property of a commensurate orbit. Ely and Howell have shown that traditional stationkeeping (SK) methods are unable to maintain a repeating groundtrack in the presence of complex dynamics, such as with chaotic motion. They developed an alternate SK method that is able to maintain a repeating groundtrack for eccentric, commensurate orbits. The focus of the current study is to investigate orbits with characteristics that are similar to GPS satellites except with modestly larger eccentricities. It will be shown that at eccentricities larger than approx. .01 the chaotic regions become significant, and the need arises for a robust stationkeeping approach, such as developed in. FurtheRmore, the investigation will reveal that the influence of luni-solar perturbations contributes to the growth of eccentricity, thus increasing the probability of encountering chaotic motion during a typical satellite lifetime.

Ely, Todd A.↗

Analysis of Measured and Predicted Acoustics From an XV-15 Flight Test

Flight acoustic and vehicle state data from an XV-15 acoustic flight test are examined. Flight predictions using TiltRotor Aeroacoustic Code (TRAC) are performed for a level flight (repeated) and four descent conditions (including a blade vortex interaction (BVI)). The assumptions and procedures used for TRAC flight predictions as well as the variability in flight measurements, which are used for input and comparison to predictions, are investigated in detail. Differences were found in the measured vehicle airspeed, altitude, glideslope, and vehicle orientation (yaw, pitch, and roll angle) between each of the repeat runs. These differences violate some of the prediction assumptions and significantly impacted the resulting acoustic predictions. Multiple acoustic pulses, with a variable time between the pulses, were found in the measured acoustic time histories for the repeat runs. These differences could be attributed in part to the variability in vehicle orientation. Acoustic predictions that used the measured vehicle orientation for the repeat runs captured this multiple pulse variability. Thickness noise was found to be dominant on approach for all the cases, except the BVI condition. After the aircraft passed overhead, broadband noise and low frequency loading noise were dominant. The predicted LowSPL time histories compared well with measurement on approach to the array for the non-BVI conditions and poorly for the BVI condition. Accurate prediction of the lift share between the rotor and fuselage must be known in order to improve predictions. At a minimum, measurements of the rotor thrust and tip-path-plane angle are critical to further develop accurate flight acoustic prediction capabilities.

Boyd, D. Douglas, Jr.↗