Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

A Subsurface Explorer for Deep Underground Exploration on Mars

A subsurface explorer (SSX) is being developed at the Jet Propulsion Laboratory which is suitable for exploration of the deep underground environments on Mars. The device is a self-contained piledriver which uses a novel 'spinning hammer' technology to convert a small continuous power feed from the surface over a two-wire tether into a large rotational energy of a spinning mass. The rotational energy is converted to translational energy by a novel mechanism described here. The hammer blows propagate as shock waves through a nosepiece, pulverizing the medium ahead of the SSX. A small portion of the pulverized medium is returned to the surface through a hole liner extending behind the SSX. This tube is 'cast in place' from two chemical feedstocks which come down from the surface through passages in the hole liner and which are reacted together to produce new material with which to produce the hole liner. The lined hole does not need to be the full diameter of the SSX: approximately 100 kilograms of liner material can create a tunnel liner with a three millimeter inside diameter and a six millimeter outside diameter with at total length of four kilometers. Thus it is expected that core samples representing an overlapping set of three-millimeter diameter cores extending the entire length of the SSX traverse could be returned to the surface. A pneumatic prototype has been built which penetrated easily to the bottom of an eight meter vertical test facility. An electric prototype is now under construction. It is expected that the SSX will be able to penetrate through sand or mixed regolith, ice, permafrost, or solid rock, such as basalt. For pure or nearly pure ice applications, the device may be augmented with hot water jets to melt the ice and stir any sediment which may build up ahead of the vehicle. It is expected that an SSX approximately one meter long, three to four centimeters in diameter, and with a power budget of approximately 200 Watts will be able to explore up to approximately five kilometers deep at the rate of about ten meters per day.

Wilcox, B. H.↗

Multistage, multiseasonal and multiband imagery to identify and qualify non-forest vegetation resources

A description of space and supporting aircraft photography for the interpretation and analyses of non-forest (shrubby and herbaceous) native vegetation is presented. The research includes the development of a multiple sampling technique to assign quantitative area values of specific plant community types included within an assigned space photograph map unit. Also, investigations of aerial film type, scale, and season of photography for identification and quantity measures of shrubby and herbaceous vegetation were conducted. Some work was done to develop automated interpretation techniques with film image density measurement devices.

Driscoll, R. S.↗

Development of an electrostatic propulsion engine using sub-micron powders as the reaction mass

Asteroid sample return missions would benefit from development of an improved rocket engine. Chemical rockets achieve their large thrust with high mass consumption rate (dm/dt) but low exhaust velocity; therefore, a large fraction of their total mass is fuel. Present day ion thrusters are characterized by high exhaust velocity, but low dm/dt; thus, they are inherently low thrust devices. However, their high exhausy velocity is poorly matched to typical mission requirements and therefore, wastes energy. A better match would be intermediate between the two forms of propulsion. This could be achieved by electrostatically accelerating solid powder grains, raising the possibility that interplanetary material could be processed to use as reaction mass. An experiment to study the charging properties of sub-micron sized powder grains is described. If a suitable material can be identified, then it could be used as the reaction mass in an electrostatic propulsion engine. The experiment employs a time of flight measurement to determine the exhaust velocity (v) of various negatively charged powder grains that were charged and accelerated in a simple device. The purpose is to determine the charge to mass ratio that can be sustained for various substances. In order to be competitive with present day ion thrusters, a specific impulse (v/g) of 3000 to 5000 seconds is required. Preliminary results are presented. More speculatively, there are some mission profiles that would benefit from collection of reaction mass at the remote asteroid site. Experiments that examine the generation of sub-micron clusters by electrostatic self-disruption of geologically derived material are planned.

Herbert, F.↗

Low background IR detector and detector array evaluations

A technology program has been underway at Ames since 1978 to develop and evaluate detectors and integrated detector arrays for low-background astronomical applications. The approach is to evaluate existing (less than 24 micron) array technology under low-background conditions, with the aim of adapting and optimizing existing devices. For longer wavelengths, where the technology is much less mature, development is sponsored and devices are evaluated, in both discrete and array formats, for eventual applications. The status of this program has been reported previously. We rely on industrial and university sources for the detectors. Typically, after a brief functionality check in the supplier's laboratory, we work with the device at Ames to characterize its low-background performance. In the case of promising arrays or detectors, we conduct ground-based telescope testing to face the problems associated with real applications. A list of devices tested at Ames is given. In the array category, accumulation-mode charge-injection-devices (AMCIDs) appear repeatedly; this reflects our recent experience with the 2 x 64 and 16 x 16 arrays. Results from the 1 x 16 CID and InSb CCD have been reported. The status of our tests of the discrete Ge:x detectors from Lawrence Berkeley Laboratory are described below. Tests of a 1 x 2 switched sample photoconductor array are just beginning. A 32-channel CMOS multiplexer has been tested at 10 K. Low-temperature silicon MOSFETs and germanium JFETs have also been tested, primarily at Ball Aerospace. This paper describes results to date on three elements of this program: AMCID array, discrete Ge:Ga detectors, and Ge JFET preamplifiers.

Goebel, J. H.↗

Investigation of Flow Conditioners for Compact Jet Engine Simulator Rig Noise Reduction

The design requirements for two new Compact Jet Engine Simulator (CJES) units for upcoming wind tunnel testing lead to the distinct possibility of rig noise contamination. The acoustic and aerodynamic properties of several flow conditioner devices are investigated over a range of operating conditions relevant to the CJES units to mitigate the risk of rig noise. An impinging jet broadband noise source is placed in the upstream plenum of the test facility permitting measurements of not only flow conditioner self-noise, but also noise attenuation characteristics. Several perforated plate and honeycomb samples of high porosity show minimal self-noise but also minimal attenuation capability. Conversely, low porosity perforated plate and sintered wire mesh conditioners exhibit noticeable attenuation but also unacceptable self-noise. One fine wire mesh sample (DP450661) shows minimal selfnoise and reasonable attenuation, particularly when combined in series with a 15.6 percent open area (POA) perforated plate upstream. This configuration is the preferred flow conditioner system for the CJES, providing up to 20 dB of broadband attenuation capability with minimal self-noise.

Doty, Michael J.↗

Ohmic contacts for laser diodes

Requirements for ohmic contacts to laser diodes are discussed, and properties of Schottky barrier tunneling contacts are reviewed. A procedure is described for measuring contact resistance on fabricated laser material without the need for specially constructed samples and contact configurations. Measurements of contact resistance and estimates of specific contact resistance are given for Ti/Pt/Au contacts to surfaces with three different doping levels. It was found that below a p-type carrier concentration of 1 x 10 to the 19th per cu cm the contact resistance is likely to be too high for good device performance. At higher doping levels, a specific contact resistance as low as 2 x 10 to the -6th ohm sq cm was obtained. Oxide stripe lasers provided with the type of contact discussed in this paper have been operated without failures for periods up to 7 years at a current density at the contact of 6-8 kA/sq cm. It appears therefore that these contacts satisfy the need for low resistance and durability and that, at the same time, they do not cause any obvious material degradation.

Ladany, I.↗

Convergent-Filament Nonmechanical Pump

Simple device induces small flow of liquid without help of moving parts, in presence or absence of gravity. Drops of liquid move on filaments from wide end of cone to narrow end. Gradually blend with drops on adjacent filaments to form large drops with menisci. Important use expected to be returning liquid condensate in heat pipes, and collection of samples from clouds or fog.

Collins, Earl R., Jr.↗

Countermeasures for Mitigation of Sensorimotor Decrements Following Head-Down Tilt Bed Rest

BACKGROUND Astronauts experience postflight disturbances in postural and locomotor control due to sensorimotor adaptations during spaceflight. These alterations may have adverse consequences if a rapid egress is required after landing. Although exercise is partially effective for mitigating cardiovascular and muscular deconditioning, additional countermeasures are needed to further preserve sensorimotor function. Proprioception training and electrical muscle stimulation (EMS) are two promising in-flight countermeasures. Since prolonged head down tilt bed rest (HDTBR) is a spaceflight analog for body unloading and causes postural and locomotor control decrements that parallel those observed after spaceflight, it can be used to facilitate the development of these countermeasures. METHODS This study will determine the effects of proprioception training and EMS on functional task performance and sensorimotor function following 60 days of 6° HDTBR. Subjects will be randomly assigned to one of four groups: 1) an EMS arm, 2) a proprioception training arm, 3) an exercise plus proprioceptive training arm, and 4) a control arm. The EMS countermeasure will include daily bilateral stimulation of selected bilateral lower extremity muscles (30 minutes per session). Proprioception training will be performed three days per week (25 minutes per session) consisting of body-loaded postural tasks in the horizontal position on an air bearing sled. Exercise training will mimic current protocols used on the International Space Station, but treadmill aerobic exercise will be replaced with additional cycling aerobic exercise. Primary outcome measures will include pre- and post- HDTBR functional tests that require high demand for dynamic control of postural stability. Secondary measures will be used to explore key physiological changes that underlie countermeasure benefits. All HDTBR and data collection activities will be completed by the German Aerospace Center (DLR) at the :envihab facility. Given the constrained samples size, a Bayesian modelling approach will be used to quantify the probability that there is an effect of a given magnitude. HARDWARE AND PROTOCOL DEVELOPMENT Final hardware modifications and protocol developments were completed in preparation for Campaign 1, which began in September 2024. These included shipment, setup, and operator training for the transportable gravity bed, horizontal squat device, foam obstacle course, EMS devices, leg dexterity system, foot sole skin sensitivity system, and Radiofrequency Echographic Multi Spectrometry (REMS) ultrasound device. In addition, specialized protocols were developed for data collection using DLR’s equipment, including muscle morphology magnetic resonance imaging (MRI), optical coherence tomography, venous blood flow MRI and ultrasound, muscle ultrasound and impedance, and skin blood flow ultrasound. We will present early data from the first campaign, which concluded in November, 2024. These will be compared with previous data from the recent 30-day HDTBR campaigns (Spaceflight associated neuro-ocular syndrome countermeasures (SANS-CM)) conducted at DLR. RELEVANCE The deliverable from this project will be proof-of-concept sensorimotor countermeasure designs for functional task performance with full assessment of efficacy in a spaceflight analog. If one or more countermeasures are effective, they will be translated for validation with the suite of operationally implemented in-flight countermeasures.

T R Macaulay↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

Separation of Single-Walled Carbon Nanotubes with DEP-FFF

A process using a modified dielectrophoresis device separates single-walled carbon nanotubes (SWNTs) according to their polarizability in electric fields. This depends on the size and dielectric constant of individual nanotubes and easily separates metallic from semiconducting nanotubes. Separation by length has also been demonstrated. Partial separation (enrichment) according to bandgap (which is linked to polarizability) has also been shown and can be improved to full separation of individual types of semiconducting SWNTs with better control over operational parameters and the length of SWNT starting material. This process and device can be scaled affordably to generate useful amounts of semiconducting SWNTs for electronic device development and production. In this study, a flow injection dielectrophoresis technique was used with a modified dielectrophoresis device. The length, width, and height of the modified chamber were 28, 2.5, and 0.025 cm, respectively. On the bottom of the chamber, there are two arrays of 50-m-wide, 2-m-thick gold electrodes, which are connected to an AC voltage generator and are alternately arranged so that every electrode is adjacent to two electrodes of the opposite polar. There is an additional plate electrode on the top of the chamber that is negatively biased. During the experiment, a syringe pump constantly pumps in the mobile phase, 1-percent sodium dodecylbenzene sulfonate (SDBS) solution, into the chamber. The frequency and voltage are set to 1 MHz and 10 V peak-to-peak, respectively. About 150 micro-L of SWNTs in 1- percent SDBS decanted solution are injected to the mobile phase through a septum near the entrance of the chamber. The flow rate of the mobile phase is set to 0.02 cu cm/min. The injected SWNTs sample flows through the chamber before it is lead into a fluorescence flow-through cell and collected for further analysis. The flow-through cell has three windows, thus allowing the fluorometer to collect fluorescence spectrum and visible absorption spectrums simultaneously. Dielectrophoresis field-flow fractionation (DEP-FFF) generally depends on interaction of a sedimentation force and DEP force for particle separation, and SWNTs are neutrally buoyant in water. In this innovation, the third electrode was added to create a sedimentation force based on DC electrophoresis. This makes this particular device applicable to separations on any neutrally buoyant particles in solution and a more general process for a broad range of nanomaterials sorting and separations.

Schmidt, Howard K.↗

NASA Charge Coupled Device (CCD) Spectrometer System (NCSS)

A small lightweight NCSS was designed, constructed, and is now being bench tested at Wallops. The unit provides 256, 2.7 nm wide channels in the visible spectrum from approximately 400 to 1100 nm. The present input slit provides a spectral impulse response of about 10 nm. Up to five NCSS sensors may be bused to one data system interface. The NCSS contains a high speed, 16 bit analog to digital converter (ADC) with an integral wide-band sample-and-hold amplifier. The NCSS was developed primarily for use with the Airbone Oceanographic Lidar (AOL). A prototype NCSS is presently interfaced to the AOL. The AOL will use two new NCSS units onboard the Goddard P-3A aircraft. They will provide the AOL with high resolution sky and ocean spectra. The up-looking NCSS will provide the AOL data system (AOLDS) with down-welling solar radiance, and the down-looking NCSS will provide ocean color spectra. The solar radiance will be used to correct various ocean color algorithms now being researched.

Wright, C. W.↗

Electro-optic crystals and their use for light modulation

Several methods of modulating a beam of light, which have been described in the literature, utilizing the influence of an electrical signal on the birefringence of certain crystals, will be reviewed. These employ optics which respond to the state of polarization of a light beam, and include intensity modulation, position modulation, and the possibility of an electrically tuned optical filter. The influence of the piezo-optic, or strain contribution to the total electro-optic response in the design of an optoelectronic device will be discussed. Current experimental work in our laboratory in which the strain contribution is separated from the direct effect will be described. The strain-free effect is measured by applying a step voltage to the crystal, and observing the initial response. The electro-optical transient response can be observed with nanosecond time resolution. An electronic sampling technique is used to extract the desired response from photon noise. The stress-free or low-frequency effect is measured similarly but at low audio frequencies. Single crystal tetragonal BaT10 3 has been investigated in detail with the result that the strain-optic contribution to the low frequency effect r_(c) = r_(33)—r_(13) is about 80% of the total, where it is only 10% in KDP and 45% in ADP. The magnitudes of the electro-optic effect, dielectric constant, and other related properties are compared for several materials potentially useful as electro-optic modulators, and some comments are made about the practical problems of building a modulator.

ELECTRO-OPTICS↗

Advanced Small Rocket Chambers. Basic Program and Option 2: Fundamental Processes and Material Evaluation

Propellants, chamber materials, and processes for fabrication of small high performance radiation cooled liquid rocket engines were evaluated to determine candidates for eventual demonstration in flight-type thrusters. Both storable and cryogenic propellant systems were considered. The storable propellant systems chosen for further study were nitrogen tetroxide oxidizer with either hydrazine or monomethylhydrazine as fuel. The cryogenic propellants chosen were oxygen with either hydrogen or methane as fuel. Chamber material candidates were chemical vapor deposition (CVD) rhenium protected from oxidation by CVD iridium for the chamber hot section, and film cooled wrought platinum-rhodium or regeneratively cooled stainless steel for the front end section exposed to partially reacted propellants. Laser diagnostics of the combustion products near the hot chamber surface and measurements at the surface layer were performed in a collaborative program at Sandia National Laboratories, Livermore, CA. The Material Sample Test Apparatus, a laboratory system to simulate the combustion environment in terms of gas and material temperature, composition, and pressure up to 6 Atm, was developed for these studies. Rocket engine simulator studies were conducted to evaluate the materials under simulated combustor flow conditions, in the diagnostic test chamber. These tests used the exhaust species measurement system, a device developed to monitor optically species composition and concentration in the chamber and exhaust by emission and absorption measurements.

Jassowski, Donald M.↗

Use of nonlinear identification in robust attitude and attitude rate estimation for SAMPEX

A method is described for obtaining optimal attitude estimation/identification algorithms for spacecraft lacking attitude rate measurement devices (rate gyros), and then demonstrated using actual flight data from the Solar, Anomalous, and Magnetospheric Particle Explorer (SAMPEX) spacecraft. SAMPEX does not have on-board rate sensing, and relies on sun sensors and a three-axis magnetometer for attitude determination. The absence of rate data normally reduces both the total amount of data available and the sampling density (in time) by a substantial fraction. In addition, attitude data is occasionally unavailable (for example, during sun occultation). As a result, the sensitivity of the estimates to model uncertainty and to measurement noise increases. In order to maintain accuracy in the attitude estimates, there is an increased need for accurate models of the rotational dynamics. The Minimum Model Error(MME)/Least Square Correlation(LSC) algorithm accurately identifies an improved model for SAMPEX to be used during periods of complete data loss or extreme noise. The model correction is determined by estimating only one orbit(the identification pass) just prior to the assumed data loss(the prediction pass). The MME estimator correctly predicted the states during the identification phase, but more importantly determines the necessary model correction trajectory, d(t). The LSC algorithm is then used to find this trajectory's functional form, H(x(t)). The results show significant improvement of the new corrected model's attitude estimates as compared to the original uncorrected model's estimates. The possible functional form of the correction term is limited at this point in the study to functions strictly of the estimated states. The results, however, strongly suggest that functions based on the relative position of the satellite may also be possible candidates for future consideration.

Mook, D. Joseph↗

Laser Time-of-Flight Mass Spectrometry for Space

A miniature reflection time-of-flight mass spectrometer for in situ planetary surface analysis is described. The laser ablation mass spectrometer (LAMS) measures the regolith's elemental and isotopic composition without high-voltage source extraction or sample preparation. The compact size (< 2 x 10(exp 3) cubic cm) and low mass (approximately 2 kg) of LAMS, due to its fully coaxial design and two-stage reflectron, fall within the strict resource limitations of landed science missions to solar system bodies. A short-pulse laser focused to a spot with a diameter approximately 30-50 micrometers is used to obtain microscopic surface samples. Assisted by a microimager, LAMS can interactively select and analyze a range of compositional regions (with lateral motion) and with repeated pulses can access unweathered, subsurface materials. The mass resolution is calibrated to distinguish isotopic peaks at unit masses, and detection limits are on resolved to a few ppm. The design and calibration method of a prototype LAMS device is described, which include the development of preliminary relative sensitivity coefficients for major element bulk abundance measurements.

Brinckerhoff, W. B.↗

Development of arrays of position-sensitive microcalorimeters for Constellation-X

We are developing arrays of position-sensitive transition-edge sensor (POST) X-ray detectors for future astronomy missions such as NASA's Constellation-X. The POST consists of multiple absorbers thermally coupled to one or more transition-edge sensor (TES). Each absorber element has a different thermal coupling to the TES. This results in a distribution of different pulse shapes and enables position discrimination between the absorber elements. POST'S are motivated by the desire to achieve the largest possible focal plane area with the fewest number of readout channels and are ideally suited to increasing the Constellation-X focal plane area, without comprising on spatial sampling. Optimizing the performance of POST'S requires careful design of key parameters such as the thermal conductances between the absorbers, TES and the heat sink. as well as the absorber heat capacities. Using recently developed signal processing algorithms we have investigated the trade-off between position-sensitivity, energy resolution and pulse decay time. based on different device design parameters for PoST's. Our new generation of PoST's utilize technology successfully developed on high resolution (approximately 2.5eV) single pixels arrays of Mo/Au TESs. also under development for Constellation-X. This includes noise mitigation features on the TES and low resistivity electroplated absorbers. We report on the first experimental results from these new one and two-channel PoST"s, consisting of all Au and composite Au/Bi absorbers, which are designed to achieve an energy resolution of < 10 eV. coupled with count-rates of 100's per pixel per second and position sensitivity over the energy range 0.3-10 keV.

Smith, S. J.↗

Miniature, Low-Power, Waveguide Based Infrared Fourier Transform Spectrometer for Spacecraft Remote Sensing

Fourier transform spectrometers have a venerable heritage as flight instruments. However, obtaining an accurate spectrum exacts a penalty in instrument mass and power requirements. Recent advances in a broad class of non-scanning Fourier transform spectrometer (FTS) devices, generally called spatial heterodyne spectrometers, offer distinct advantages as flight optimized systems. We are developing a miniaturized system that employs photonics lightwave circuit principles and functions as an FTS operating in the 7-14 micrometer spectral region. The inteferogram is constructed from an ensemble of Mach-Zehnder interferometers with path length differences calibrated to mimic scan mirror sample positions of a classic Michelson type FTS. One potential long-term application of this technology in low cost planetary missions is the concept of a self-contained sensor system. We are developing a systems architecture concept for wide area in situ and remote monitoring of characteristic properties that are of scientific interest. The system will be based on wavelength- and resolution-independent spectroscopic sensors for studying atmospheric and surface chemistry, physics, and mineralogy. The self-contained sensor network is based on our concept of an Addressable Photonics Cube (APC) which has real-time flexibility and broad science applications. It is envisaged that a spatially distributed autonomous sensor web concept that integrates multiple APCs will be reactive and dynamically driven. The network is designed to respond in an event- or model-driven manner or reconfigured as needed.

Hewagama, TIlak↗

Supercritical Water Mixture (SCWM) Experiment in the High Temperature Insert-Reflight (HTI-R)

Current research on supercritical water processes on board the International Space Station (ISS) focuses on salt precipitation and transport in a test cell designed for supercritical water. This study, known as the Supercritical Water Mixture Experiment (SCWM) serves as a precursor experiment for developing a better understanding of inorganic salt precipitation and transport during supercritical water oxidation (SCWO) processes for the eventual application of this technology for waste management and resource reclamation in microgravity conditions. During typical SCWO reactions any inorganic salts present in the reactant stream will precipitate and begin to coat reactor surfaces and control mechanisms (e.g., valves) often severely impacting the systems performance. The SCWM experiment employs a Sample Cell Unit (SCU) filled with an aqueous solution of Na2SO4 0.5-w at the critical density and uses a refurbished High Temperature Insert, which was used in an earlier ISS experiment designed to study pure water at near-critical conditions. The insert, designated as the HTI-Reflight (HTI-R) will be deployed in the DECLIC (Device for the Study of Critical Liquids and Crystallization) Facility on the International Space Station (ISS). Objectives of the study include measurement of the shift in critical temperature due to the presence of the inorganic salt, assessment of the predominant mode of precipitation (i.e., heterogeneously on SCU surfaces or homogeneously in the bulk fluid), determination of the salt morphology including size and shapes of particulate clusters, and the determination of the dominant mode of transport of salt particles in the presence of an imposed temperature gradient. Initial results from the ISS experiments will be presented and compared to findings from laboratory experiments on the ground.

salts↗