Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning Transmission Electron Microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Very-High Dynamic Range, 10,000 Frames/Second Pixel Array Detector for Electron Microscopy

Precision and accuracy of quantitative scanning transmission electron microscopy (STEM) methods such as ptychography, and the mapping of electric, magnetic, and strain fields depend on the dose. Reasonable acquisition time requires high beam current and the ability to quantitatively detect both large and minute changes in signal. A new hybrid pixel array detector (PAD), the second-generation Electron Microscope Pixel Array Detector (EMPAD-G2), addresses this challenge by advancing the technology of a previous generation PAD, the EMPAD. The EMPAD-G2 images continuously at a frame-rates up to 10 kHz with a dynamic range that spans from low-noise detection of single electrons to electron beam currents exceeding 180 pA per pixel, even at electron energies of 300 keV. The EMPAD-G2 enables rapid collection of high-quality STEM data that simultaneously contain full diffraction information from unsaturated bright-field disks to usable Kikuchi bands and higher-order Laue zones. Test results from 80 to 300 keV are presented, as are first experimental results demonstrating ptychographic reconstructions, strain and polarization maps. We introduce a new information metric, the maximum usable imaging speed (MUIS), to identify when a detector becomes electron-starved, saturated or its pixel count is mismatched with the beam current.

36 MATERIALS SCIENCE↗

Unsupervised learning of ferroic variants from atomically resolved STEM images

An approach for the analysis of atomically resolved scanning transmission electron microscopy data with multiple ferroic variants in the presence of imaging non-idealities and chemical variabilities based on a rotationally invariant variational autoencoder (rVAE) is presented. We show that an optimal local descriptor for the analysis is a sub-image centered at specific atomic units, since materials and microscope distortions preclude the use of an ideal lattice as a reference point. The applicability of unsupervised clustering and dimensionality reduction methods is explored and is shown to produce clusters dominated by chemical and microscope effects, with a large number of classes required to establish the presence of rotational variants. Comparatively, the rVAE allows extraction of the angle corresponding to the orientation of ferroic variants explicitly, enabling straightforward identification of the ferroic variants as regions with constant or smoothly changing latent variables and sharp orientational changes. This approach allows further exploration of the chemical variability by separating the rotational degrees of freedom via rVAE and searching for remaining variability in the system. The code used in this article is available at https://github.com/saimani5/ferroelectric_domains_rVAE.

30 DIRECT ENERGY CONVERSION↗

Multi-pass transmission electron microscopy

Feynman once asked physicists to build better electron microscopes to be able to watch biology at work. While electron microscopes can now provide atomic resolution, electron beam induced specimen damage precludes high resolution imaging of sensitive materials, such as single proteins or polymers. Here, we use simulations to show that an electron microscope based on a multi-pass measurement protocol enables imaging of single proteins, without averaging structures over multiple images. While we demonstrate the method for particular imaging targets, the approach is broadly applicable and is expected to improve resolution and sensitivity for a range of electron microscopy imaging modalities, including, for example, scanning and spectroscopic techniques. The approach implements a quantum mechanically optimal strategy which under idealized conditions can be considered interaction-free.

47 OTHER INSTRUMENTATION↗

Fabrication artifacts and parallel loss channels in metamorphic epitaxial aluminum superconducting resonators

Fabrication of coplanar waveguide resonators with internal quality factors near 10 6 remains challenging. In this work, high-purity single crystal superconductors are implemented through metamorphic epitaxial aluminum that is grown via molecular beam epitaxy on silicon and sapphire substrates. X- ray diffraction and scanning transmission electron microscopy indicate an abrupt highly ordered interface that results in crystal relaxation within a few monolayers of the substrate interface and no measurable interfacial contamination. Quarter- wave coplanar waveguide resonators are fabricated using optical lithography and measured at temperatures below 100 mK. Post measurement characterization with charge contrast imaging in a scanning electron microscope identifies processing artifacts at the waveguide sidewalls, on the exposed substrate area and on the exposed aluminum surface. Of primary importance are processing induced corrosion defects on aluminum sidewalls, nanoparticle contamination, and photoresist residue that are difficult to remove without affecting the superconductor material. Likely correlations between these artifacts and the measured quality factor are discussed in context of device to device variations in resonator performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Corrosion of Zinc Cold Spray Coatings in a Wet Sweet and Sour Gas Environment

Internal corrosion is a problem for steel pipelines transporting natural gas or CO 2 containing water and partial pressures of H 2 S higher than 0.3 kPa (0.05 psi). This work aims to mitigate internal corrosion in steel pipelines transporting natural gas containing H 2 S using cold spray coatings. Two types of the cold spray binary metallic coatings (zinc chromium [ZnCr]. zinc niobium [ZnNb]) were studied using electrochemical techniques: potentiodynamic polarization, linear polarization resistance, and electrochemical impedance spectroscopy. The corrosion resistance of cold spray coatings (ZnCr, ZnNb) was evaluated in an environment containing 4 bar CO 2 pressure, simulating the partial pressures found in gas transmission lines over a solution of 3.5 wt% NaCl heated to 40°C. A concentration of 0.003 M Na 2 S 2 O 3 ·5H 2 O, corresponding to H 2 S partial pressures around 0.079 bar (1.146 psi), was used to simulate sour conditions. Postcorrosion surface characterization was performed using a scanning electron microscope (SEM) equipped with an energy-dispersive x-ray spectroscope (EDS) and x-ray diffraction analysis. The data showed that the presence of 0.003 M Na 2 S 2 O 3 ·5H 2 O shifted the corrosion potential to more anodic values and decreased the corrosion current density. Both coatings showed similar behavior after 1 h of exposure in the CO 2 /H 2 S environment, indicating that similar electrochemical reactions were occurring on ZnNb and ZnCr. SEM images and EDS surface analyses for specimens showed a significant change in the surface chemical composition of carbon steel coated with ZnNb and ZnCr after 24 h of immersion. In the presence of thiosulfate (under sour conditions), the formation of corrosion product layers (ZnCO 3 and ZnS) on top of ZnNb and ZnCr coatings increased their corrosion resistance, which helped to reduce their corrosion by a factor of 2. Under a sweet environment, the corrosion rates for steel coated with cold spray coatings after 14 d of exposure are lower than that for galvanized steel by a factor of 5 due to the ZnCO 3 layer formed on top of the coatings. The ZnCO 3 layer formed on the steel surface acts as a physical barrier against corrosion by blocking the diffusion of corrosive species to the surface. No localized attack was observed. ZnCr Cold spray coating with defect showed promising corrosion protection against CO 2 corrosion (sweet corrosion) after 14 d of exposure to a CO 2 environment. Here, the scratch on the coating simulated damage created in service, and it was deep enough to expose the substrate material (steel). The formation of zinc oxide (ZnO) and zinc carbonate (ZnCO 3 ) on the scratch confirmed the cathodic protection of the steel by ZnCr and ZnNb coatings.

36 MATERIALS SCIENCE↗

Microstructural characterization and mechanical property of active soldering anodized 6061 Al alloy using Sn-3.5Ag-xTi active solders

Active solders Sn-3.5Ag-xTi varied from x = 0 to 6 wt.% Ti addition were prepared by vacuum arc re-melting and the resultant phase formation and variation of microstructure with titanium concentration were analyzed using X-ray diffraction, optical microscopy and scanning electron microscopy. The Sn-3.5Ag-xTi active solders are used as metallic filler to join with anodized 6061 Al alloy for potential applications of providing a higher heat conduction path. Their joints and mechanical properties were characterized and evaluated in terms of titanium content. The mechanical property of joints was measured by shear testing. The joint strength was very dependent on the titanium content. Solder with a 0.5 wt.% Ti addition can successfully wet and bond to the anodized aluminum oxide layers of Al alloy and posses a shear strength of 16.28 {+-} 0.64 MPa. The maximum bonding strength reached 22.24 {+-} 0.70 MPa at a 3 wt.% Ti addition. Interfacial reaction phase and chemical composition were identified by a transmission electron microscope with energy dispersive spectrometer. Results showed that the Ti element reacts with anodized aluminum oxide to form Al{sub 3}Ti-rich and Al{sub 3}Ti phases at the joint interfaces. - Highlights: Black-Right-Pointing-Pointer Active solder joining of anodized Al alloy needs 0.5 wt.% Ti addition for Sn-3.5Ag. Black-Right-Pointing-Pointer The maximum bonding strength occurs at 3 wt.% Ti addition. Black-Right-Pointing-Pointer The Ti reacts with anodized Al oxide to form Al{sub 3}Ti-rich and Al{sub 3}Ti at joint interface.

36 MATERIALS SCIENCE↗

In-Situ Liquid Cell Transmission Electron Microscopy of Nanoparticles from Spent Nuclear Fuel

Noble Metal Particles (NMP) that are present in SNF play an important role in the Fuel Matrix Degradation (FMD) Model that is being considered for predicting the release rate of radionuclides from a waste package. Previous characterization of chemically separated NMP from SNF showed that these were well-crystallized nanoparticles containing Mo, Tc, Ru, Rh, and Pd with some evidence of actinides. These same chemically separated particles were re-characterized following 10 years of storage as the separated material in water. Scanning Transmission Electron Microscopy (STEM) analysis revealed that significant alteration had occurred in this material during storage, resulting in the almost complete degradation of the NMP. We hypothesized that radiolytic damaged had occurred in the material. To support these concepts, we synthesized a mixed Ru-Pd nanoparticle and subjected it to irradiation in the electron microscope in an in-situ liquid cell. We demonstrated that intense radiation can lead to the decomposition of these metallic particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Overview of Neutron Irradiated SiC Layer Behavior using Micro-and Nano-Characterization Techniques

The complexity of fission product distribution and composition within the SiC layer of tristructural isotropic (TRISO) coated particles, irradiation effects on the SiC structure as well as the variable nature of metallic fission product release, has led to the exploration of multiple micro- and nano-characterization techniques. The fine scale of the fission product precipitates necessitates unique learnings and application of electron microscopic techniques with irradiated fuel during the Advanced Gas Reactor (AGR)-1 experiment analysis. A summarized discussion on the specific advanced techniques with associated method development for TRISO coated particles is provided followed by the down selected techniques currently considered to provide the highest impact. Techniques considered are electron probe micro-analyzer (EPMA), scanning transmission electron microscopy (STEM), and Precession electron diffraction (PED). SiC grain boundary characteristics are evaluated due to the mobility of specific fission products through grain boundaries. PED was performed for understanding the role of grain boundary character on fission product transport. One set of comparative analyses between AGR-1 and AGR-2 particles leads to a finding that the AGR-1, high-Ag-retention particle, had statistically more coincidence site lattice (CSL)-related grain boundaries (but fewer low-angle grain boundaries), compared to the AGR-2 particle. This implies that CSL-related grain boundaries may have a direct influence on Ag retention. However, precipitates were found on a relatively small fraction of CSL-related grain boundaries in both particles. In another set of comparison between AGR-1 and AGR-2 particles that were subjected to safety testing, there is significant differences in average SiC grain boundary distributions, but the fission product distributions on these grain boundaries are very similar.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Micro- and Nano-techniques for the Study of Fission Product Precipitation in SiC Layer

The complexity of fission product distribution and composition within the SiC layer of tristructural isotropic (TRISO) coated particles, irradiation effects on the SiC structure as well as the variable nature of metallic fission product release, has led to the exploration of multiple micro- and nano-characterization techniques. The fine scale of the fission product precipitates necessitates unique learnings and application of electron microscopic techniques with irradiated fuel during the Advanced Gas Reactor (AGR)-1 experiment analysis. A summarized discussion on the specific advanced techniques with associated method development for TRISO coated particles is provided followed by the down selected techniques currently considered to provide the highest impact. Techniques considered are electron probe micro-analyzer (EPMA), scanning transmission electron microscopy (STEM), and Precession electron diffraction (PED). SiC grain boundary characteristics are evaluated due to the mobility of specific fission products through grain boundaries. PED was performed for understanding the role of grain boundary character on fission product transport. One set of comparative analyses between AGR-1 and AGR-2 particles leads to a finding that the AGR-1, high-Ag-retention particle, had statistically more coincidence site lattice (CSL)-related grain boundaries (but fewer low-angle grain boundaries), compared to the AGR-2 particle. This implies that CSL-related grain boundaries may have a direct influence on Ag retention. However, precipitates were found on a relatively small fraction of CSL-related grain boundaries in both particles. In another set of comparison between AGR-1 and AGR-2 particles that were subjected to safety testing, there is significant differences in average SiC grain boundary distributions, but the fission product distributions on these grain boundaries are very similar.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct observation of ice nucleation events on individual atmospheric particles

Heterogeneous ice nucleation is a physical chemistry process of critical relevance to a range of topics in the fundamental and applied sciences and technologies. Heterogeneous ice nucleation remains insufficiently understood, partially due to the lack of experimental methods capable of obtaining in situ microscopic details of ice formation over nucleating substrates or particles. Here, we present microscopic observations of ice nucleation events on kaolinite particles at the nanoscale and demonstrate the capability of direct tracking and micro-spectroscopic characterization of individual ice nucleating particles (INPs) in an authentic atmospheric sample. Furthermore, this approach utilizes a custom-built ice nucleation cell, interfaced with an Environmental Scanning Electron Microscope (IN-ESEM platform) operated at temperatures and relative humidities relevant for heterogeneous ice nucleation. The IN-ESEM platform allows dynamic observations of individual ice formation events over particles in isobaric and isothermal experiments. Isothermal experiments on individual kaolinite particles demonstrate that ice crystals preferably nucleate at the edges of the stacked kaolinite platelets, rather than on their basal planes. Finally, these experimental observations of the location of ice nucleation provide direct information for further theoretical chemistry predictions of ice formation on kaolinite.

54 ENVIRONMENTAL SCIENCES↗

Effect of stress on Laves phase precipitation in creep ruptured Grade 92 ferritic martensitic steel characterized by a novel accessible method

At high temperature conditions relevant to fossil and nuclear energy plants, Laves phase (Fe 2 X, X=Mo, W) precipitation is observed in common ferritic martensitic (FM) structural steels, with various reported effects on creep behavior. Despite being valuable metrics to correlate with mechanical properties and other precipitate phases, the volume fraction and number density of Laves phase precipitates has been difficult to quantify accurately using common techniques such as transmission electron microscopy (TEM) due to the relatively large size (∼0.25 μm) and low number density (∼10 11 cm −3 ) of Laves precipitates. Here, to address this characterization challenge, we developed and demonstrated a high-throughput and widely accessible method to quantify the volume fraction and number density of the Laves phase based on scanning electron microscope (SEM) images with a backscattered electron signal and the information depth (ID) of backscattered electrons. We applied this new technique in creep ruptured Grade 92 FM steel to study the effect of Laves phase on creep properties and determine the influence of stress on Laves phase precipitation. The quantitative accuracy of the SEM-based volume fraction and number density values was verified using synchrotron high energy X-ray diffraction and serial sectioning tomography. Stress did not significantly affect the Laves phase size or volume fraction during creep testing at 550 – 650°C and stress levels of 90 – 260 MPa (vs. unstressed conditions). Conversely, a moderate but statistically significant stress-enhanced increase in Laves phase number density, corresponding to an increase in nucleation rate, occurred during creep exposure above 110 MPa.

Creep↗

Effect of a Silicone Contaminant Film on the Transmittance Properties of AR-coated Fused Silica

We present the results of a laboratory test to determine the effects of bulk deposited, DC-704 silicone contaminant film on the transmittance properties of an anti-reflective (AR) coated fused silica optical substrate. Testing and optical measurements were performed in vacuum in the Boeing Combined Effects Test Facility (CETF). The test and measurement procedures are described herein. Measurement results are presented showing the change in transmittance characteristics as a function of contaminant deposit thickness and vacuum ultra-violet (vuv) exposure levels. Measurement results show an initial degradation in the transmittance of the contaminated sample. This is followed by a partial recovery in sample transmittance as the sample is exposed to additional VUV radiation. Transmittance results also show a loss of transmission in the ultraviolet portion of the spectrum and an increase in transmission in the infrared portion of the spectrum. These transmittance results are characteristic of thin-film interference effects. Thin-film analyses indicate that some of the observed transmittance results can be successfully modeled, but only if the contaminant film is assumed to be SiO2 rather than DC-704 silicone. Post-test Scanning Electron Microscope (SEM) scans of the test sample indicate the formation of contaminant islands and the presence of a thin uniform coating of contaminant deposit on the sample

Boeder, Paul A.↗

AEcroscopy: A Software–Hardware Framework Empowering Microscopy Toward Automated and Autonomous Experimentation

Microscopy has been pivotal in improving the understanding of structure-function relationships at the nanoscale and is by now ubiquitous in most characterization labs. However, traditional microscopy operations are still limited largely by a human-centric click-and-go paradigm utilizing vendor-provided software, which limits the scope, utility, efficiency, effectiveness, and at times reproducibility of microscopy experiments. Here, in this work, a coupled software–hardware platform is developed that consists of a software package termed AEcroscopy (short for Automated Experiments in Microscopy), along with a field-programmable-gate-array device with LabView-built customized acquisition scripts, which overcome these limitations and provide the necessary abstractions toward full automation of microscopy platforms. The platform works across multiple vendor devices on scanning probe microscopes and electron microscopes. It enables customized scan trajectories, processing functions that can be triggered locally or remotely on processing servers, user-defined excitation waveforms, standardization of data models, and completely seamless operation through simple Python commands to enable a plethora of microscopy experiments to be performed in a reproducible, automated manner. This platform can be readily coupled with existing machine-learning libraries and simulations, to provide automated decision-making and active theory-experiment optimization to turn microscopes from characterization tools to instruments capable of autonomous model refinement and physics discovery.

47 OTHER INSTRUMENTATION↗

Quantitative comparison of bright field and annular bright field imaging modes for characterization of oxygen octahedral tilts

Octahedral tilt behavior is increasingly recognized as an important contributing factor to the physical behavior of perovskite oxide materials and especially their interfaces, necessitating the development of high-resolution methods of tilt mapping. There are currently two major approaches for quantitative imaging of tilts in scanning transmission electron microscopy (STEM), bright field (BF) and annular bright field (ABF). In this study, we show that BF STEM can be reliably used for measurements of oxygen octahedral tilts. While optimal conditions for BF imaging are more restricted with respect to sample thickness and defocus, we find that BF imaging with an aberration-corrected microscope with the accelerating voltage of 300 kV gives us the most accurate quantitative measurement of the oxygen column positions. Using the tilted perovskite structure of BiFeO 3 (BFO) as our test sample, we simulate BF and ABF images in a wide range of conditions, identifying the optimal imaging conditions for each mode. Finally, we show that unlike ABF imaging, BF imaging remains directly quantitatively interpretable for a wide range of the specimen mistilt, suggesting that it should be preferable to the ABF STEM imaging for quantitative structure determination.

36 MATERIALS SCIENCE↗

Studies on linear, nonlinear optical and excited state dynamics of silicon nanoparticles prepared by picosecond laser ablation

We report results from our studies on the fabrication and characterization of silicon (Si) nanoparticles (NPs) and nanostructures (NSs) achieved through the ablation of Si target in four different liquids using ∼2 picosecond (ps) pulses. The consequence of using different liquid media on the ablation of Si target was investigated by studying the surface morphology along with material composition of Si based NPs. The recorded mean sizes of these NPs were ∼9.5 nm, ∼37 nm, ∼45 nm and ∼42 nm obtained in acetone, water, dichloromethane (DCM) and chloroform, respectively. The generated NPs were characterized by selected area electron diffraction (SAED), high resolution transmission microscopy (HRTEM), Raman spectroscopic techniques and Photoluminescence (PL) studies. SAED, HRTEM and Raman spectroscopy data confirmed that the material composition was Si NPs in acetone, Si/SiO{sub 2} NPs in water, Si-C NPs in DCM and Si-C NPs in chloroform and all of them were confirmed to be polycrystalline in nature. Surface morphological information of the fabricated Si substrates was obtained using the field emission scanning electron microscopic (FESEM) technique. FESEM data revealed the formation of laser induced periodic surface structures (LIPSS) for the case of ablation in acetone and water while random NSs were observed for the case of ablation in DCM and chloroform. Femtosecond (fs) nonlinear optical properties and excited state dynamics of these colloidal Si NPs were investigated using the Z-scan and pump-probe techniques with ∼150 fs (100 MHz) and ∼70 fs (1 kHz) laser pulses, respectively. The fs pump-probe data obtained at 600 nm consisted of single and double exponential decays which were tentatively assigned to electron-electron collisional relaxation (<1 ps) and non-radiative transitions (>1 ps). Large third order optical nonlinearities (∼10{sup −14} e.s.u.) for these colloids have been estimated from Z-scan data at an excitation wavelength of 680 nm suggesting that the colloidal Si NPs find potential applications in photonic devices.

36 MATERIALS SCIENCE↗