Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Tracers for Characterizing Enhanced Geothermal Systems

Information about the times of thermal breakthrough and subsequent rates of thermal drawdown in enhanced geothermal systems (EGS) is necessary for reservoir management, designing fracture stimulation and well drilling programs, and forecasting economic return. Thermal breakthrough in heterogeneous porous media can be estimated using conservative tracers and assumptions about heat transfer rates; however, tracers that undergo temperature-dependent changes can provide more detailed information about the thermal profile along the flow path through the reservoir. To be effectively applied, the thermal reaction rates of such temperature sensitive traces must be well characterized for the range of conditions that exist in geothermal systems. Reactive tracers proposed in the literature include benzoic and carboxylic acids (Adams) and organic esters and amides (Robinson et al.); however, the practical temperature range over which these tracers can be applied (100-275°C) is somewhat limited. Further, for organic esters and amides, little is known about their sorption to the reservoir matrix and how such reactions impact data interpretation. Another approach involves tracers where the reference condition is internal to the tracer itself. Two examples are: 1) racemization of polymeric amino acids, and 2) mineral thermoluminescence. In these cases internal ratios of states are measured rather than extents of degradation and mass loss. Racemization of poly-L-lactic acid (for example) is temperature sensitive and therefore can be used as a temperature-recording tracer depending on the rates of racemization and stability of the amino acids. Heat-induced quenching of thermoluminescence of pre-irradiated LiF can also be used. To protect the tracers from alterations (extraneous reactions, dissolution) in geothermal environments we are encapsulating the tracers in core-shell colloidal structures that will subsequently be tested for their ability to be transported and to protect the tracers from incidental reactions. We review the criteria for practical reactive tracers, which serves as the basis for experimental testing and characterization and can be used to identify other potential candidate tracers. We will also discuss the information obtainable from individual tracers, which has implications for using multiple tracers to obtain information about the thermal history of a reservoir. We will provide an update on our progress for conducting proof-of-principle tests for reactive tracers in the Raft River geothermal system.

15 GEOTHERMAL ENERGY↗

Experimental cell for molecular beam deposition and magnetic resonance studies of matrix isolated radicals at temperatures below 1 K

We present the design and performance of an experimental cell constructed for matrix isolation studies of H and D atoms in solid H{sub 2}/D{sub 2} films, which are created by molecular beam deposition at temperatures below 1 K. The sample cell allows sensitive weighing of the films by a quartz microbalance (QM) and their studies by magnetic resonance techniques in a strong magnetic field of 4.6 T. We are able to regulate the deposition rate in the range from 0.01 to 10 molecular layers/s, and measure the thickness with ≈0.2 monolayer resolution. The upper QM electrode serves as a mirror for a 128 GHz Fabry-Perot resonator connected to an electron spin resonance (ESR) spectrometer. H and D atoms were created by RF discharge in situ in the sample cell, and characterized by ESR and electron-nuclear double resonance. From the magnetic resonance measurements we conclude that the films are smooth and provide homogeneous trapping conditions for embedded atoms. The current sample cell design also makes it possible to calibrate the ESR signal and estimate the average and local concentrations of H and D radicals in the film.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neural simulation-based inference of the Higgs trilinear self-coupling via off-shell Higgs production

One of the forthcoming major challenges in particle physics is the experimental determination of the Higgs trilinear self-coupling. While efforts have largely focused on on-shell double- and single-Higgs production in proton-proton collisions, off-shell Higgs production has also been proposed as a valuable complementary probe. In this article, we design a hybrid neural simulation-based inference (NSBI) approach to construct a likelihood of the Higgs signal incorporating modifications from the Standard Model effective field theory (SMEFT), relevant background processes, and quantum interference effects. It leverages the training efficiency of matrix-element-enhanced techniques, which are vital for robust SMEFT applications, while also incorporating the practical advantages of classification-based methods for effective background estimates. We demonstrate that our NSBI approach achieves sensitivity close to the theoretical optimum and provide expected constraints for the high-luminosity upgrade of the Large Hadron Collider. While we primarily concentrate on the Higgs trilinear self-coupling, we also consider constraints on other SMEFT operators that affect off-shell Higgs production.

Ghosh, Aishik [Univ. of California, Irvine, CA (Un↗

The ETROC Project: Precision Timing ASIC Development for LGAD-based CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD silicon devices to be read out by ETROCs for precision timing measurement with down to 30 ps timing resolution. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel cell being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. Approximately 15% of the sensors near the highest eta region will experience hadron fluence above 1e15 neq/cm² towards end of operation of HL-LHC, resulting in small signal amplitude with LGAD gain reduced to around 10. For this reason, the front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile.

97 MATHEMATICS AND COMPUTING↗

Orbit-determination performance of Doppler data for interplanetary cruise trajectories. Part 1: Error analysis methodology

An error covariance analysis methodology is used to investigate different weighting schemes for two-way (coherent) Doppler data in the presence of transmission-media and observing-platform calibration errors. The analysis focuses on orbit-determination performance in the interplanetary cruise phase of deep-space missions. Analytical models for the Doppler observable and for transmission-media and observing-platform calibration errors are presented, drawn primarily from previous work. Previously published analytical models were improved upon by the following: (1) considering the effects of errors in the calibration of radio signal propagation through the troposphere and ionosphere as well as station-location errors; (2) modelling the spacecraft state transition matrix using a more accurate piecewise-linear approximation to represent the evolution of the spacecraft trajectory; and (3) incorporating Doppler data weighting functions that are functions of elevation angle, which reduce the sensitivity of the estimated spacecraft trajectory to troposphere and ionosphere calibration errors. The analysis is motivated by the need to develop suitable weighting functions for two-way Doppler data acquired at 8.4 GHz (X-band) and 32 GHz (Ka-band). This weighting is likely to be different from that in the weighting functions currently in use; the current functions were constructed originally for use with 2.3 GHz (S-band) Doppler data, which are affected much more strongly by the ionosphere than are the higher frequency data.

Ulvestad, J. S.↗

New Developments in LC-MS and Other Hyphenated Techniques

Extensive challenges faced by analytical chemists in studying real world complex samples such as biological body fluids, tissue samples, environmental and geological samples have lead to the development of advanced analytical approaches. The vast array of contemporary technologies can be categorized into two major areas: sample separation and mass spectrometry analysis. Current state-of-the-art sample separation methods include gas chromatography, high performance liquid chromatography, ultra high pressure liquid chromatography, solid phase extraction, capillary electrophoresis, and gas phase separation techniques such as ion mobility spectrometry. The recent trend in sample separation is to combine (or hyphenate) multiple techniques that employ different separation mechanisms to maximize separation efficiency. The most widely used combinations include two-dimensional gas chromatography, strong cation exchange or weak cation exchange chromatography followed by reversed-phase liquid chromatography, two-dimensional reversed-phase liquid chromatography, liquid chromatography followed by ion mobility spectrometry and two-dimensional electrophoresis techniques. The introduction of atmospheric pressure ionization techniques such as electrospray ionization and matrix assisted laser desorption ionization and variations of the two have drastically increased the impact of mass spectrometry on bioanalytical applications. Mass spectrometry itself has tremendously improved over the years in terms of sensitivity, detection limits, dynamic range and sequencing capabilities. Currently, mass spectrometers can attain zeptomolole detection limits with five orders of magnitude dynamic range. In this chapter, we summarize recent developments in hyphenated techniques and their applications to complex sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying Uncertainties through Advanced Theoretical Analysis for Image and Signal Reconstruction NLV-02-15, Year 1 of 2

Presentation describes project to (1) adapt accelerated matrix-free linear system solvers for applying new statistical approaches to very large–scale problems, (2) characterize the degree to which new statistical methods are superior to classical methods in respect to the sensitivity to “tuning parameters,” and (3) develop a new mathematical theory and associated numerical methods for computing the point spread function of an x-ray imaging system.

97 MATHEMATICS AND COMPUTING↗

Quantifying Uncertainties Through Advanced Theoretical Analysis for Image and Signal Reconstruction, NLV-02-15, Year 2 of 2

Presentation describes project to (1) adapt accelerated matrix-free linear system solvers for applying new statistical approaches to very large–scale problems, (2) characterize the degree to which new statistical methods are superior to classical methods in respect to the sensitivity to “tuning parameters,” and (3) develop a new mathematical theory and associated numerical methods for computing the point spread function of an x-ray imaging system.

97 MATHEMATICS AND COMPUTING↗

Sensitivity Testing of the NSTAR Ion Thruster

During the Extended Life Test of the DS1 flight spare ion thruster, the engine was subjected to sensitvity testing in order to characterize the macroscopic dependence of discharge chamber sensitivity to a +\-3% vatiation in main flow, cathode flow and beam current, and to +\5% variation in beam and accelerator voltage, was determined for the minimum- (THO), half- (TH8) and full power (TH15) throttle levels. For each power level investigared, 16 high/low operating conditions were chosen to vary the flows, beam current, and grid voltages in in a matrix that mapped out the entire parameter space. The matrix of data generated was used to determine the partial derivative or senitivity of the dependent parameters--discharge voltage, discharge current, discharge loss, double-to-single-ion current ratio, and neutralizer-keeper voltage--to the variation in the independent parameters--main flow, cathode flow, beam current, and beam voltage. The sensititivities of each dependent parameter with respect to each independent parameter were determined using a least-square fit routine. Variation in these sensitivities with thruster runtime was recorded over the duration of the ELT, to detemine if discharge performance changed with thruster wear. Several key findings have been ascertained from the sensitivity testing. Discharge operation is most sensitve to changes in cathode flow and to a lesser degree main flow. The data also confirms that for the NSTAR configuration plasma production is limited by primary electron input due to the fixed neutral population. Key sensitivities along with their change with thruster wear (operating time) will be presented. In addition double ion content measurements with an ExB probe will also be presented to illustrate beam ion production and content sensitivity to the discharge chamber operating parameteres.

electric propulsion↗

Single-Filament Imaging Mass Spectrometry Lipidomics in Arthrospira platensis

Elucidating intra-organismal biochemical and lipid organization in photosynthetic biological cell factories of filamentous cyanobacteria, i.e., Arthrospira platensis (Spirulina), is important to track physiological response mechanisms during growth. Little is known about the filaments' biochemical organization and cellular structure and no label-free imaging techniques exist that provide molecular mapping. We applied ultra-high resolution mass spectrometry (7T FT-ICR-MS) matrix-assisted laser desorption ionization (MALDI) imaging to immobilized Spirulina filaments to investigate the localization of lipids across distinct physiological regions. We optimized matrix selection and deposition methods with the goal of facilitating high spatial, and intra-filament, resolution using untargeted multivariate statistical spectral deconvolution across MS pixels. Our results demonstrate an improved two step application with an optimized procedure for intra-organismal lipid profiling to improve analyte sensitivity and achieve higher spatial resolution, whereby we evaluate three conventional matrices 2,5-dihydroxybenzoic acid (DHB), a 9:1 ratio of DHB:superDHB (sDHB), 1,5- diaminonaphthalene (DAN) and a 50:50 mix of DHB:sDHB and compare delineation and pixel-based elucidation of intra-filament lipidomics. We identified a total of 1,626 features that could be putatively assigned a lipid-like formula based on database query and 46 unique features, with associated lipid assignments that were significantly distinct in their intra-filament location. MALDI- imaging MS with untargeted statistical spectral deconvolution was used to visualize intra-filament lipidomics organization in Spirulina filaments. Improvements in matrix deposition, including sequential sublimation and pneumatic spraying, increased signal abundance at high spatial resolution and allowed for identification of distinct lipid composition regions. Here in this work outlines a methodology that may be used for micro-ecological untargeted molecular phenotyping.

09 BIOMASS FUELS↗

PCEMCAN - Probabilistic Ceramic Matrix Composites Analyzer: User's Guide, Version 1.0

PCEMCAN (Probabalistic CEramic Matrix Composites ANalyzer) is an integrated computer code developed at NASA Lewis Research Center that simulates uncertainties associated with the constituent properties, manufacturing process, and geometric parameters of fiber reinforced ceramic matrix composites and quantifies their random thermomechanical behavior. The PCEMCAN code can perform the deterministic as well as probabilistic analyses to predict thermomechanical properties. This User's guide details the step-by-step procedure to create input file and update/modify the material properties database required to run PCEMCAN computer code. An overview of the geometric conventions, micromechanical unit cell, nonlinear constitutive relationship and probabilistic simulation methodology is also provided in the manual. Fast probability integration as well as Monte-Carlo simulation methods are available for the uncertainty simulation. Various options available in the code to simulate probabilistic material properties and quantify sensitivity of the primitive random variables have been described. The description of deterministic as well as probabilistic results have been described using demonstration problems. For detailed theoretical description of deterministic and probabilistic analyses, the user is referred to the companion documents "Computational Simulation of Continuous Fiber-Reinforced Ceramic Matrix Composite Behavior," NASA TP-3602, 1996 and "Probabilistic Micromechanics and Macromechanics for Ceramic Matrix Composites", NASA TM 4766, June 1997.

Shah, Ashwin R.↗

SENSITIVITY STUDIES OF HEATER ROD DESIGN FOR TRANSIENT CRITICAL HEAT FLUX EXPERIMENTS IN TREAT

An important area of reactor safety is the cladding-to-coolant heat transfer under fast transient conditions. These conditions can occur during events such as a reactivity-initiated accident (RIA). In this paper we present the work performed under a laboratory directed research and development (LDRD) project, headed by Idaho National Laboratory (INL). The goal was to develop a test matrix to inform on the design of a borated steel heater rod that will induce critical heat flux (CHF) within an experimental capsule filled with water, using the TREAT facility, when submitted to a power pulse. The energy deposition in the rod and occurrence of CHF were identified as the most important key Figures of Merit (FoMs) used in the design process. Energy deposition was varied by using different pulse characteristics and various boron concentrations in the rod. A power coupling factor (PCF) was determined for each boron concentration. A sensitivity study determined the lowest limiting PCF needed to induce CHF in water with different degrees of subcooling while keeping pressure constant. Boron concentrations between 0.1-1.54 wt.% were considered. Additionally, the value of CHF is also known to increase during a rapid transient. A CHF multiplier sensitivity study focused on an example case concluded that CHF is no longer exceeded when the value is between 2.6- and 2.9-times higher. Lastly, a self-shielding study was performed to determine whether a borated tube could be used in place of a solid borated rod. The study determined that the inner 1mm of the rod can essentially be excluded or instrumented without heat generation penalties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operando Spectromicroscopy of Sulfur Species in Lithium-Sulfur Batteries

Here, a novel cross-sectional battery cell was developed to characterize lithium-sulfur batteries using X-ray spectromicroscopy. Chemically sensitive X-ray maps were collected operando at energies relevant to the expected sulfur species and were used to correlate changes in sulfur species with electrochemistry. Significant changes in the sulfur/carbon composite electrode were observed from cycle to cycle including rearrangement of the elemental sulfur matrix and PEO10LiTFSI binder. Polysulfide concentration and area of spatial diffusion increased with cycling, indicating that some polysulfide dissolution is irreversible, leading to polysulfide shuttle. Fitting of the maps using standard sulfur and polysulfide XANES spectra indicated that upon subsequent discharge/charge cycles, the initial sulfur concentration was not fully recovered; polysulfides and lithium sulfide remained at the cathodes with higher order polysulfides as the primary species in the region of interest. Quantification of the polysulfide concentration across the electrolyte and electrode interfaces shows that the polysulfide concentration before the first discharge and after the third charge is constant within the electrolyte, but while cycling, a significant increase in polysulfides and a gradient toward the lithium metal anode forms. Finally, this chemically and spatially sensitive characterization and analysis provides a foundation for further operando spectromicroscopy of lithium-sulfur batteries.

25 ENERGY STORAGE↗

Fluorescent Dye-doped Sol-gel Sensor for Highly Sensitive Carbon Dioxide Gas Detection below Atmospheric Concentrations

Optical fluorescence sol-gel sensors have been developed for the detection of carbon dioxide gas in the 0.03?30% range with a detection limit of 0.008% (or 80 ppm) and a quantitation limit of 0.02% (or 200 ppm) CO{sub 2}. Sol?gels were spin-coated on glass slides to create an organically modified silica-doped matrix with the 1-hydroxypyrene-3,6,8-trisulfonate (HPTS) fluorescent indicator. The luminescence intensity of the HPTS indicator (513 nm) is quenched by CO{sub 2}, which protonates the anionic form of HPTS. An ion pair technique was used to incorporate the lipophilic dye into the hydrophilic sol?gel matrix. TiO{sub 2} particles (<5 {mu}m diameter) were added to induce Mie scattering and increase the incident light interaction with the sensing film, thus increasing the signal-to-noise ratio. Moisture-proof overcoatings have been used to maintain a constant level of water inside the sensor films. The optical sensors are inexpensive to prepare and can be easily coupled to fiber optics for remote sensing capabilities. A fiber-optic bundle was used for the gas detection and shown to work as part of a multianalyte platform for simultaneous detection of multiple analytes. The studies reported here resulted in the development of sol?gel optical fluorescent sensors for CO{sub 2} gas with sensitivity below that in the atmosphere (ca. 387 ppm). These sensors are a complementary approach to current FT-IR measurements for real-time carbon dioxide detection in environmental applications.

47 OTHER INSTRUMENTATION↗

Measurement of the Higgs boson production rate in association with top quarks in final states with electrons, muons, and hadronically decaying tau leptons at $\sqrt{s} =$ 13 TeV

The rate for Higgs (${\mathrm{H}} $) bosons production in association with either one (${\mathrm{t}} {\mathrm{H}} $) or two (${\mathrm{t}} {{\overline{{{\mathrm{t}}}}}} {\mathrm{H}} $) top quarks is measured in final states containing multiple electrons, muons, or tau leptons decaying to hadrons and a neutrino, using proton–proton collisions recorded at a center-of-mass energy of $13\,\text {Te}\text {V} $ by the CMS experiment. The analyzed data correspond to an integrated luminosity of 137$\,\text {fb}^{-1}$. The analysis is aimed at events that contain ${\mathrm{H}} \rightarrow {\mathrm{W}} {\mathrm{W}} $, ${\mathrm{H}} \rightarrow {\tau } {\tau } $, or ${\mathrm{H}} \rightarrow {\mathrm{Z}} {\mathrm{Z}} $ decays and each of the top quark(s) decays either to lepton+jets or all-jet channels. Sensitivity to signal is maximized by including ten signatures in the analysis, depending on the lepton multiplicity. The separation among ${\mathrm{t}} {\mathrm{H}} $, ${\mathrm{t}} {{\overline{{{\mathrm{t}}}}}} {\mathrm{H}} $, and the backgrounds is enhanced through machine-learning techniques and matrix-element methods. The measured production rates for the ${\mathrm{t}} {{\overline{{{\mathrm{t}}}}}} {\mathrm{H}} $ and ${\mathrm{t}} {\mathrm{H}} $ signals correspond to $0.92 \pm 0.19\,\text {(stat)} ^{+0.17}_{-0.13}\,\text {(syst)} $ and $5.7 \pm 2.7\,\text {(stat)} \pm 3.0\,\text {(syst)} $ of their respective standard model (SM) expectations. The corresponding observed (expected) significance amounts to 4.7 (5.2) standard deviations for ${\mathrm{t}} {{\overline{{{\mathrm{t}}}}}} {\mathrm{H}} $, and to 1.4 (0.3) for ${\mathrm{t}} {\mathrm{H}} $ production. Assuming that the Higgs boson coupling to the tau lepton is equal in strength to its expectation in the SM, the coupling $y_{{\mathrm{t}}}$ of the Higgs boson to the top quark divided by its SM expectation, $\kappa _{{\mathrm{t}}}=y_{{\mathrm{t}}}/y_{{\mathrm{t}}}^{\mathrm {SM}}$, is constrained to be within $-0.9< \kappa _{{\mathrm{t}}}< -0.7$ or $0.7< \kappa _{{\mathrm{t}}}< 1.1$, at 95% confidence level. This result is the most sensitive measurement of the ${\mathrm{t}} {{\overline{{{\mathrm{t}}}}}} {\mathrm{H}} $ production rate to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronic Structures and Magnetism of Zr-, Th-, and U-based Metal-Organic Frameworks (MOFs) by Density Functional Theory

Metal-organic frameworks (MOFs) have recently gained wide interest as candidate materials for nuclear waste immobilization. While the fundamental thermodynamic properties, such as the substitution energies determine the favorability of radionuclide sequestration by utilization of a MOF matrix, the studies of MOF electronic structure reveal the role of d-, and/or f-electrons on changes in physical properties of actinide-containing materials. We use density functional theory (DFT) calculations to investigate the electronic structures of Zr-, Th-, and U-MOFs, including their electronic band structures and, where appropriate, their magnetic properties. We employ various DFT methods including DFT+U, collinear spin-polarization, spin-orbit coupling, and different flavors of exchange-correlation functionals to assess the robustness to the specific exchange-correlation functional. Unlike the Zr-, and Th-MOFs, the U-MOF is found to be sensitive to electron localization and spin; hence we explore the magnetic structure of the U-MOF in further detail.

Metal-Organic Framework, MOF, Actinides, DFT↗

Preliminary Results from an Investigation into Nanostructured Nuclear Radiation Detectors for Non-Proliferation Applications

In recent years, the concept of embedding composite scintillators consisting of nanosized inorganic crystals in an organic matrix has been actively pursued. Nanocomposite detectors have the potential to meet many of the homeland security, non-proliferation, and border and cargo-screening needs of the nation and, by virtue of their superior nuclear identification capability over plastic, at roughly the same cost as plastic, have the potential to replace all plastic detectors. Nanocomposites clearly have the potential of being a gamma ray detection material that would be sensitive yet less expensive and easier to produce on a large scale than growing large, whole crystals of similar sensitivity. These detectors would have a broad energy range and a sufficient energy resolution to perform isotopic identification. The material can also be fabricated on an industrial scale, further reducing cost. This investigation focused on designing and fabricating prototype core/shell and quantum dot (QD) detectors. Fourteen core/shell and four QD detectors, all with the basic consistency of a mixture of nanoparticles in a polymer matrix with different densities of nanoparticles, were prepared. Nanoparticles with sizes <10 nm were fabricated, embedded in a polystyrene matrix, and the resultant scintillators’ radiation detector properties were characterized. This work also attempted to extend the gamma energy response on both low- and high-energy regimes by demonstrating the ability to detect low-energy and high-energy gamma rays. Preliminary results of this investigation are consistent with a significant response of these materials to nuclear radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet-printed CNT Electrodes-droplet Based Paracetamol Detection in Biological Fluids for “Point-of-care” Applications

A disposable acetaminophen biosensor based on inkjet-printed CNT electrodes (IJPCNT) modified with amidase/cerium dioxide@graphene nanoribbons composite was developed (ACeO2@GNR/IJPCNT). The enzyme amidase A was used for the first time as a recognition element. Inkjet-printed CNT electrodes served as a basis for the construction of a biosensor that enables droplet detection using 5 μL sample volume. The biosensor showed high selectivity, sensitivity, a low detection limit of 0.18 μM and a wide working linear range from 1 to 100 μM. The proposed approach allows fast and reliable detection of acetaminophen in biological fluids with negligible matrix effect and remarkable reproducibility. © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗