Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Modulation and detection of optical signals

A summary of information is presented which is related to the modulation and detection of information on optical carriers. It emphasizes the treatment of information transfer through an entire system. The most common configurations are considered: intensity modulation, amplitude modulation, frequency or phase modulation, and both direct and coherent detection. In assessing these configurations information capacity and message signal-to-noise ratio are used as a basis of comparison. The physical and geometric treatment of optical heterodyne (or coherent) detection is given.

Goodwin, F. E.↗

Origin of electrical signals for plasma etching end point detection: Comparison of end point signals and electron density

Electrical signals are used for end point detection in plasma etching, but the origin of the electrical changes observed at end point is not well understood. As an etch breaks through one layer and exposes an underlayer, the fluxes and densities of etch products and reactants in the gas phase will change. The resulting perturbation in gas composition may alter the plasma electron density, which in turn may affect the electrical signals. Alternatively, changes in substrate electrical properties or surface properties, such as work function or emitted electron yield, may be involved. To investigate these effects, experiments were performed in a radio-frequency (rf)-biased, inductively coupled reactor, during CF{sub 4}/Ar plasma etching of silicon dioxide films on silicon substrates. A complete set of electrical parameters, for the bias as well as the inductive source, was measured and compared. The most useful end point signal was found to be the fundamental rf bias impedance, which decreases when the oxide is removed. A simultaneous increase in plasma electron density was measured by a wave cutoff probe. Analytical sheath models indicate that the measured change in electron density accounts for nearly all of the impedance decrease. The change in electron density can in turn be explained by the effects of etch products or reactants on gas composition. In contrast, electrons emitted from the wafer surface play at most a minor role in the changes in electron density and impedance observed at end point.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noncoherent detection of periodic signals

The optimal Bayes detector for a general periodic waveform having uniform delay and additive white Gaussian noise is examined. It is shown that the detector is much more complex than that for the well known cases of pure sine waves (i.e. classical noncoherent detection) and narrowband signals. An interpretation of the optimal processing is presented, and several implementations are discussed. The results have application to the noncoherent detection of optical square waves.

Gagliardi, R. M.↗

Casting a wide signal net with future direct dark matter detection experiments

As dark matter (DM) direct detection experiments continue to improve their sensitivity they will inevitably encounter an irreducible background arising from coherent neutrino scattering. This so-called "neutrino floor" may significantly reduce the sensitivity of an experiment to DM-nuclei interactions, particularly if the recoil spectrum of the neutrino background is approximately degenerate with the DM signal. This occurs for the conventionally considered spin-independent (SI) or spin-dependent (SD) interactions. In such case, an increase in the experiment's exposure by multiple orders of magnitude may not yield any significant increase in sensitivity. The typically considered SI and SD interactions, however, do not adequately reflect the whole landscape of the well-motivated DM models, which includes other interactions. Since particle DM has not been detected yet in laboratories, it is essential to understand and maximize the detection capabilities for a broad variety of possible models and signatures. Here, we investigate the impact of the background arising from various neutrino sources on the discovery potential of a DM signal for a large class of viable DM-nucleus interactions and several potential futuristic experimental settings, with different target elements. For some momentum suppressed cross sections, large DM particle masses and heavier targets, we find that there is no suppression of the discovery limits due to neutrino backgrounds. Further, we explicitly demonstrate that inelastic scattering, which could appear in models with multicomponent dark sectors, would help to lift the signal degeneracy associated with the neutrino floor. This research could assist with mapping out the optimal DM detection strategy for the next generation of experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of noisy phase reference on coherent detection of unbalanced QPSK signals

A phase error in the reference signal used in coherent detection of PSK signals causes a degradation in performance; this effect on bit error probability has been much discussed in the literature for BPSK and balanced QPSK systems. For unbalanced QPSK (UQPSK) systems, where the power and data rates in the two channels are unequal, and where the channel data symbols might also be different, the problem of computing the error probability is more complex, and only approximate solutions have been previously given. In this paper, exact expressions are derived for the conditional probability of error for the I and Q channels as a function of the channel power and data rate ratio. This is done for all combinations of Manchester and NRZ signalling schemes, and it is shown that in some cases the low data rate channel can be more seriously affected by a phase offset. Numerical results are also given for the average probability of error, assuming a biphase Costas loop is used for carrier synchronization.

Osborne, H. C.↗

Detecting Unclassified Electromagnetic Signals for Secure Wireless Communication Using Open Set Recognition

We developed multiple machine learning methods for the detection and classification of new wireless communication waveforms, which is critical for targeted attacks in wireless networks and electronic warfare. Our machine learning models are capable of dynamically detecting security threats in near real time through our advanced open set recognition (OSR) approach. This model has demonstrated significant improvements in the detection of unknown waveforms, thereby enhancing the security and reliability of mission critical communications. Our approach to detecting uncertain security threats is novel; we advanced OSR techniques by incorporating domain knowledge of wireless signals. Specifically, we combined time and frequency domain model features to enhance the model’s performance. Utilizing an OSR approach eliminates the need for training data to be distributed similarly to the deployment environment and removes the requirement for the training set to contains all possible threat classes. This is crucial because it is often infeasible to determine and characterize all potential security threats in advance. Our model were trained on simulated data, generated in partnership with the University at Albany, State of New York. The data set contained a diverse array of wireless signals, including those with additive white Gaussian noise and multipath signals, with and without line of sight. This comprehensive training set allowed us to optimize our models to detect unknown waveforms under various challenging scenarios, such as low signal-to-noise ratios. By training on various waveforms, varying signal-to-noise ratio, and different sample sizes under normal conditions, our models were fine tuned to perform effectively in challenging environments.

99 - GENERAL AND MISCELLANEOUS↗

DETECTION OF POTENTIAL TRANSIT SIGNALS IN 16 QUARTERS OF KEPLER MISSION DATA

We present the results of a search for potential transit signals in 4 yr of photometry data acquired by the Kepler mission. The targets of the search include 111,800 stars which were observed for the entire interval and 85,522 stars which were observed for a subset of the interval. We found that 9743 targets contained at least one signal consistent with the signature of a transiting or eclipsing object where the criteria for detection are periodicity of the detected transits, adequate signal-to-noise ratio, and acceptance by a number of tests which reject false positive detections. When targets that had produced a signal were searched repeatedly, an additional 6542 signals were detected on 3223 target stars, for a total of 16,285 potential detections. Comparison of the set of detected signals with a set of known and vetted transit events in the Kepler field of view shows that the recovery rate for these signals is 96.9%. The ensemble properties of the detected signals are reviewed.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of trapped charge on the signal formation and detection efficiency for subsequent pulses in irradiated silicon sensors

Envisaged high energy physics experiments like the Future Circular Collider require unprecedented radiation hardness of the detectors, as well as short readout time due to high luminosity and occupancy. Silicon has proven to be extremely radiation hard. Sufficient signals can be recorded even at fluences close to 1 ∙ 1 0 16 n e q / cm 2 . Here, the signal formation was studied in silicon strip sensors, irradiated and annealed until the phenomenon of charge multiplication occurred. ATLAS12EC R0 mini sensors were tested by means of edge TCT measurements at temperatures around –20 °C. It was observed that the detection of subsequent signals separated up to several microseconds is altered by the charge trapped during the preceding pulses. The effects of trapped charge on the electrical configuration of a sensor are well known as a polarization or pumping effect in larger band-gap materials like diamond, but is often neglected for silicon at this relatively high temperature. The investigation of the effect created by trapped charges in silicon sensors using subsequent pulses allows to gain information on important parameters such as de-trapping times. Furthermore, it shows a severe impact on the sensor performance in a pile-up scenario. The irradiation fluence and hence the effective doping concentration, the temperature and the amount of initially created charge have a large impact on this phenomenon. The measurements presented help to characterize this phenomenon; particular attention was paid to the application point of view.

47 OTHER INSTRUMENTATION↗

Near optimum delay-line detection filters for serial detection of MSK signals

A method for designing transversal delay-line filter approximations to the matched filter for the serial detection of minimum-shift keyed (MSK) modulated signals is given. Two configurations are characterized in terms of signal-to-noise ratio degradation at a bit error rate (BER) of 10 to the -6th. One is shown to depart less than 0.3 dB from the ideal matched filter performance when its parameter values are optimized. A lumped-element equivalent is also given and shown to provide a degradation of less than 0.4 dB at a BER of 10 to the -6th

Ziemer, R. E.↗

Online Event Detection in Synchrophasor Data with Graph Signal Processing

Online detection of anomalies is crucial to enhancing the reliability and resiliency of power systems. We propose a novel data-driven online event detection algorithm with synchrophasor data using graph signal processing. In addition to being extremely scalable, our proposed algorithm can accurately capture and leverage the spatio-temporal correlations of the streaming PMU data. This paper also develops a general technique to decouple spatial and temporal correlations in multiple time series. Finally, we develop a unique framework to construct a weighted adjacency matrix and graph Laplacian for product graph. Case studies with real-world, large-scale synchrophasor data demonstrate the scalability and accuracy of our proposed event detection algorithm. Compared to the state-of-the-art benchmark, the proposed method not only achieves higher detection accuracy but also yields higher computational efficiency.

Event detection↗

Online Event Detection in Synchrophasor Data with Graph Signal Processing

Online detection of anomalies is crucial to enhancing the reliability and resiliency of power systems. We propose a novel data-driven online event detection algorithm with synchrophasor data using graph signal processing. In addition to being extremely scalable, our proposed algorithm can accurately capture and leverage the spatio-temporal correlations of the streaming PMU data. This paper also develops a general technique to decouple spatial and temporal correlations in multiple time series. Finally, we develop a unique framework to construct a weighted adjacency matrix and graph Laplacian for product graph. Case studies with real-world, large-scale synchrophasor data demonstrate the scalability and accuracy of our proposed event detection algorithm. Compared to the state-of-the-art benchmark, the proposed method not only achieves higher detection accuracy but also yields higher computational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detecting a periodic signal in the terrestrial cratering record

A time-series analysis of model periodic data, where the period and phase are known, has been performed in order to investigate whether a significant period can be detected consistently from a mix of random and periodic impacts. Special attention is given to the effect of age uncertainties and random ages in the detection of a periodic signal. An equivalent analysis is performed with observed data on crater ages and compared with the model data, and the effects of the temporal distribution of crater ages on the results from the time-series analysis are studied. Evidence for a consistent 30-m.y. period is found to be weak.

Grieve, Richard A. F.↗

A new method for the detection of a periodic signal of unknown shape and period

A method was developed for the detection and measurement of a periodic signal with unknown characteristics in a data set where the existence of such signal was not known. The method detects a signal by using Bayesian probability theory to compare a constant model for the signal to members of a class of models with periodic structure. The method was applied to simulated data generated with both stepwise and sinusoidal light curves, demonstrating that such signals can be sensitively detected and the signal frequency and its shape can be accurately estimated.

Gregory, P. C.↗

New detection system and signal processing for the tokamak ISTTOK heavy ion beam diagnostic

The tokamak ISTTOK heavy ion beam diagnostic (HIBD) operates with a multiple cell array detector (MCAD) that allows for the plasma density and the plasma density fluctuations measurements simultaneously at different sampling volumes across the plasma. To improve the capability of the plasma density fluctuations investigations, a new detection system and new signal conditioning amplifier have been designed and tested. The improvements in MCAD design are presented which allow for nearly complete suppression of the spurious plasma background signal by applying a biasing potential onto special electrodes incorporated into MCAD. The new low cost and small size transimpedance amplifiers are described with the parameters of 400 kHz, 10{sup 7} V/A, 0.4 nA of RMS noise, adequate for the plasma density fluctuations measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multi-Scale Sampling Strategy for Detecting Physiologically Significant Signals in AVIRIS Imagery

Models of photosynthetic production at ecosystem and global scales require multiple input parameters specifying physical and physiological surface features. While certain physical parameters (e.g., absorbed photosynthetically active radiation) can be derived from current satellite sensors, other physiologically relevant measures (e.g., vegetation type, water status, carboxylation capacity, or photosynthetic light-use efficiency), are not generally directly available from current satellite sensors at the appropriate geographic scale. Consequently, many model parameters must be assumed or derived from independent sources, often at an inappropriate scale. An abundance of ecophysiological studies at the leaf and canopy scales suggests strong physiological control of vegetation-atmosphere CO2 and water vapor fluxes, particularly in evergreen vegetation subjected to diurnal or seasonal stresses. For example hot, dry conditions can lead to stomatal closure, and associated "downregulation" of photosynthetic biochemical processes, a phenomenon often manifested as a "midday photosynthetic depression". A recent study with the revised simple biosphere (SiB2) model demonstrated that photosynthetic downregulation can significantly impact global climate. However, at the global scale, the exact significance of downregulation remains unclear, largely because appropriate physiological measures are generally unavailable at this scale. Clearly, there is a need to develop reliable ways of extracting physiologically relevant information from remote sensing. Narrow-band spectrometers offer many opportunities for deriving physiological parameters needed for ecosystem and global scale photosynthetic models. Experimental studies on the ground at the leaf- to stand-scale have indicated that several narrow-band features can be used to detect plant physiological status. One physiological signal is caused by xanthophyll cycle pigment activity, and is often expressed as the Photochemical Reflectance Index (PRI). Because the xanthophyll cycle pigments are photoregulatory pigments closely linked to photosynthetic function, this index can be used to derive relative photosynthetic rates. An additional signal with physiological significance is the 970 nm water absorption band, which provides a measure of liquid water content. This feature has been quantified both using a simple 2-band ratio (900/970 nm, here referred to as the "Water Band Index" or WBI;), and using the "continuum removal" method. Current atmospheric correction methods for AVIRIS imagery also obtain quantitative expressions of surface liquid water absorption based on the 970 nm water band and may be comparable to ground-based estimates of water content using this feature. However, physiological interpretations of both the PRI and the WBI are best understood at the leaf and canopy scales, where complications of atmospheric interference and complex stand and landscape features can be minimized, and where experimental manipulations can be readily applied. Currently it is not known whether these physiological indices can be used to derive meaningful physiological information from AVIRIS imagery. In addition to the problem of atmospheric interference, another challenge is that any simple physiological index can be confounded by multiple factors unrelated to physiology, and this problem can become more severe at progressively larger spatial scales. For example, previous work has suggested that both the PRI and the WBI, are strongly correlated with other optical measures of canopy structure (e.g., the Normalized Difference Vegetation Index or green vegetation fraction), indicating a confounding effect of structure on physiological signals at the larger, landscape scale. Furthermore, the normal operating mode of most imaging spectrometers does not allow simultaneous, ground truthing at a level of detail needed for physiological sampling. Additionally, manipulative experiments of physiology are difficult to apply at a geographic scale suitable for comparison with remote imagery, which often works at spatial scales that are several orders of magnitude larger than those typically used for physiological studies. These limitations require the consideration of alternative approaches to validating physiological information derived from AVIRIS data. In this report, we present a multi-scale sampling approach to detecting physiologically significant signals in narrow-band spectra. This approach explores the multi-dimensional data space provided by narrow-band spectrometry, and combines AVIRIS imagery at a large scale, with ground spectral sampling at an intermediate scale, and detailed ecophysiological measurements at a fine scale, to examine seasonally and spatially changing relationships between multiple structural and physiological variables. Examples of this approach are provided by simultaneous sampling of the Normalized Difference Vegetation Index (NDVI), an index of fractional PAR interception and green vegetation cover, the Water Band Index (WBI, an index of liquid water absorption, and the Photochemical Reflectance Index (PRI, an index of xanthophyll cycle pigment activity and photosynthetic light-use efficiency. By directly linking changing optical properties sampled on the ground with measurable physiological states, we hope to develop a basis for interpreting similar signals in AVIRIS imagery.

Gamon, John A.↗