Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software dependability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

A method for evaluating image quality of monochrome and color displays based on luminance by use of a commercially available color digital camera

Purpose: The aim of this study is to propose a method for the quantitative evaluation of image quality of both monochrome and color liquid-crystal displays (LCDs) using a commercially available color digital camera. Methods: The intensities of the unprocessed red (R), green (G), and blue (B) signals of a camera vary depending on the spectral sensitivity of the image sensor used in the camera. For consistent evaluation of image quality for both monochrome and color LCDs, the unprocessed RGB signals of the camera were converted into gray scale signals that corresponded to the luminance of the LCD. Gray scale signals for the monochrome LCD were evaluated by using only the green channel signals of the camera. For the color LCD, the RGB signals of the camera were converted into gray scale signals by employing weighting factors (WFs) for each RGB channel. A line image displayed on the color LCD was simulated on the monochrome LCD by using a software application for subpixel driving in order to verify the WF-based conversion method. Furthermore, the results obtained by different types of commercially available color cameras and a photometric camera were compared to examine the consistency of the authors’ method. Finally, image quality for both the monochrome and color LCDs was assessed by measuring modulation transfer functions (MTFs) and Wiener spectra (WS). Results: The authors’ results demonstrated that the proposed method for calibrating the spectral sensitivity of the camera resulted in a consistent and reliable evaluation of the luminance of monochrome and color LCDs. The MTFs and WS showed different characteristics for the two LCD types owing to difference in the subpixel structure. The MTF in the vertical direction of the color LCD was superior to that of the monochrome LCD, although the WS in the vertical direction of the color LCD was inferior to that of the monochrome LCD as a result of luminance fluctuations in RGB subpixels. Conclusions: The authors’ method based on the use of a commercially available color camera is useful to evaluate and understand the display performances of both monochrome and color LCDs in radiology departments.

60 APPLIED LIFE SCIENCES↗

Rapid QSTS Simulations for High-Resolution Comprehensive Assessment of Distributed PV

The rapid increase in penetration of distributed energy resources on the electric power distribution system has created a need for more comprehensive interconnection modeling and impact analysis. Unlike conventional scenario-based studies, quasi-static time-series (QSTS) simulations can realistically model time-dependent voltage controllers and the diversity of potential impacts that can occur at different times of year. However, to accurately model a distribution system with all its controllable devices, a yearlong simulation at 1-second resolution is often required, which could take conventional computers a computational time of 10 to 120 hours when an actual unbalanced distribution feeder is modeled. This computational burden is a clear limitation to the adoption of QSTS simulations in interconnection studies and for determining optimal control solutions for utility operations. The solutions we developed include accurate and computationally efficient QSTS methods that could be implemented in existing open-source and commercial software used by utilities and the development of methods to create high-resolution proxy data sets. This project demonstrated multiple pathways for speeding up the QSTS computation using new and innovative methods for advanced time-series analysis, faster power flow solvers, parallel processing of power flow solutions and circuit reduction. The target performance level for this project was achieved with year-long high-resolution time series solutions run in less than 5 minutes within an acceptable error.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assembling Multiple Models Within the RAVEN Framework

RAVEN (Risk Analysis Virtual Environment) is an INL-developed software tool that can be used to identify and increase the safety margin in complex systems. As a generic software framework, RAVEN is designed to perform parametric and probabilistic analysis based on the response of complex system codes. RAVEN is capable of investigating the system response as well as the input space using Monte Carlo, Grid, or Latin Hyper Cube sampling schemes, but its strength is focused toward system feature discovery, such as limit surfaces, separating regions of the input space leading to system failure, using dynamic supervised learning techniques. RAVEN is currently able to construct multi-targets Reduced Order Models (ROMs), which are aimed to represent the response of a system (in a fixed configuration) for multiple Figures of Merits (FOMs) and time-dependent ROMs. These capabilities represent the initial steps for a larger implementation about the interaction of multiple models. In fact, in several cases, multiple models need to interface with each other since the initial conditions of one are dependent on the outcomes of another. To better understand the problem that here is solved, it is useful to consider a simple example: The following problem is considered: a weather forecast simulation code 'a' is used to compute the external (i.e. ambient) temperature in a certain location. A second model 'b' is inquired to compute the average temperature in a room having as boundary condition, among several others, the external ambient temperature. The response of the model 'b' depends on the outcome of the model 'a'. The reported example is only aimed to illustrate the reason why the creation of a framework to make interact different models is a key development for the advancement of RAVEN as a comprehensive calculation flow driver. Before reporting how the ensemble-models have been implemented, it is necessary to briefly describe the representative Model 'entities' that are available in RAVEN.

42 ENGINEERING↗

srlife : a software tool for estimating the life of high temperature concentrating solar receivers. Part I – metallic receivers

Here, this paper introduces srlife, a tool for estimating the structural service life of concentrating solar power (CSP) receivers operating at high temperatures. Supporting both metallic and ceramic receiver designs, srlife is available as open-source software at https://github.com/applied-material-modeling/srlife and can be installed via the PyPi package manager (https://pypi.org). Given basic receiver geometry and incident heat flux, the tool performs thermohydraulic and structural analysis and estimates the life of a receiver. Designed for easy integration into a software stack, including solar field and levelized cost analysis, the tool can be utilized for optimizing receiver designs to meet service life and economic targets. This paper is Part I in a two-part series. Part I discusses the analysis process used to estimate the life of metallic receivers, along with a description of the required input data. Additionally, several heuristics applied within srlife can reduce analysis time significantly while maintaining accurate life estimations for metallic receivers when compared to full analyses. Several examples demonstrating the utility of srlife in receiver design are also discussed. Part II focuses on the life estimation of ceramic receivers, using time-dependent reliability analysis and various ceramic failure models implemented in srlife.

Creep-fatigue analysis↗

SU-E-I-62: Assessing Radiation Dose Reduction and CT Image Optimization Through the Measurement and Analysis of the Detector Quantum Efficiency (DQE) of CT Images Using Different Beam Hardening Filters

Purpose: Reducing patient dose while maintaining (or even improving) image quality is one of the foremost goals in CT imaging. To this end, we consider the feasibility of optimizing CT scan protocols in conjunction with the application of different beam-hardening filtrations and assess this augmentation through noise-power spectrum (NPS) and detector quantum efficiency (DQE) analysis. Methods: American College of Radiology (ACR) and Catphan phantoms (The Phantom Laboratory) were scanned with a 64 slice CT scanner when additional filtration of thickness and composition (e.g., copper, nickel, tantalum, titanium, and tungsten) had been applied. A MATLAB-based code was employed to calculate the image of noise NPS. The Catphan Image Owl software suite was then used to compute the modulated transfer function (MTF) responses of the scanner. The DQE for each additional filter, including the inherent filtration, was then computed from these values. Finally, CT dose index (CTDIvol) values were obtained for each applied filtration through the use of a 100 mm pencil ionization chamber and CT dose phantom. Results: NPS, MTF, and DQE values were computed for each applied filtration and compared to the reference case of inherent beam-hardening filtration only. Results showed that the NPS values were reduced between 5 and 12% compared to inherent filtration case. Additionally, CTDIvol values were reduced between 15 and 27% depending on the composition of filtration applied. However, no noticeable changes in image contrast-to-noise ratios were noted. Conclusion: The reduction in the quanta noise section of the NPS profile found in this phantom-based study is encouraging. The reduction in both noise and dose through the application of beam-hardening filters is reflected in our phantom image quality. However, further investigation is needed to ascertain the applicability of this approach to reducing patient dose while maintaining diagnostically acceptable image qualities in a clinical setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hazard Contribution Modes of Machine Learning Components

Amongst the essential steps to be taken towards developing and deploying safe systems with embedded learning-enabled components (LECs)—i.e., software components that use machine learning (ML)—are to analyze and understand the contribution of the constituent LECs to safety, and to assure that those contributions have been appropriately managed. This paper addresses both steps by, first, introducing the otion of hazard contribution modes (HCMs)—a categorization of the ways in which the ML elements of LECs can contribute to hazardous system states; and, second, describing how argumentation patterns can capture the reasoning that can be used to assure HCM mitigation. Our framework is generic in the sense that the categories of HCMs developed i) can admit different learning schemes, i.e., supervised, unsupervised, and reinforcement learning, and ii) are not dependent on the type of system in which the LECs are embedded, i.e., both cyber and cyber-physical systems. One of the goals of this work is to serve a starting point for systematizing LEC safety analysis towards eventually automating it in a tool.

Smith, Colin↗

NRAP-Open-IAM: NRAP Open Source Integrated Assessment Model

Note: This is the last version (a2.6.1) of NRAP-Open-IAM released during NRAP Phase II in 2022. The latest version of NRAP-Open-IAM is available here: https://edx.netl.doe.gov/dataset/phase-iii-nrap-open-iam NRAP-Open-IAM is an open-source software product that enables quantification of containment effectiveness and leakage risk at storage sites in the context of system uncertainties and variability. NRAP-Open-IAM represents the next-generation in a line of systems-based computational models developed for quantitative geological carbon storage (GCS) risk assessment. The model comprises a set of reduced-order and analytical models of various components of the GCS system, potential leakage pathways, receptors of concern including impact to groundwater resources and the atmosphere, a framework to support stochastic simulation, time stepping, uncertainty quantification, other analytical functionality for scenario and risk-performance evaluation, and a basic graphical user interface to support scenario development, data input simulation definition, and basic post-processing and results display. As the NRAP Open-IAM functionality continues to evolve, we continue to add to its capability to develop quantitative, probabilistic, and time-dependent profiles of the evolution of risk at a GCS site and evaluate the influence of uncertain parameters on uncertainty in predicted risk. It can be used to quantify the dynamics of reservoir saturation plume and pressure-affected area, for evaluation of the area of potential groundwater impact (i.e., Area of Review) and monitoring requirements to support cost and regulatory analysis, and for consideration of different post-injection site care and closure scenarios. This submission contains the current version of NRAP-Open-IAM available for evaluation and testing. To use the NRAP-Open-IAM, download the source code (https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/4c24a3da-3b40-4ffe-9892-c807ae9f8760) then open the NRAP-Open-IAM user's guide (https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/8b27335a-343c-4836-b8a3-3ad0bdc9e669) to read more about the tool. Installation instructions for Windows, Mac, and Linux can be found in the "installers" folder of the extracted NRAP-Open-IAM folder and describe setup of environment (e.g., Python libraries) needed for proper work of the tool. Test of installation can be done by running "python openiam_setup_tests.py" in the "setup" folder. The installation test also runs a test suite to see if the NRAP-Open-IAM has been installed correctly. To run the test suite separately, run "python iam_test.py" in the "test" folder. User's guide: https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/8b27335a-343c-4836-b8a3-3ad0bdc9e669 Developer's guide: https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/3bc6ee7d-609d-4eb6-80ba-fa6130ee0313 Reservoir simulation data used in some examples distributed with NRAP-Open-IAM: - Kimberlina: https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/eb62cece-61b2-4037-9b6d-32407dde2ab8 - Kimberlina (compartmentalized): https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/366f9530-3b32-4b84-affe-ab2df1d9a8b5 - FutureGen 2.0: https://edx.netl.doe.gov/dataset/futuregen-2-0-1008-simulation-reservoir-lookup-table NRAP-Open-IAM GitLab repository: https://gitlab.com/NRAP/OpenIAM Related publications: - Bacon, D., Yonkofski, C., Brown, C., Demirkanli, D. and Whiting, J., 2019. Risk-based post injection site care and monitoring for commercial-scale carbon storage: Reevaluation of the FutureGen 2.0 site using NRAP-Open-IAM and DREAM. International Journal of Greenhouse Gas Control 90: 102784. - Bacon, D. Demirkanli, D., and White, S., 2020. Probabilistic risk-based Area of Review (AoR) determination for a deep-saline carbon storage site. International Journal of Greenhouse Gas Control 102: 103153. - Harp, D., Oldenburg, C., and Pawar, R., 2019. A metric for evaluating conformance robustness during geologic CO2 sequestration operations. International Journal of Greenhouse Gas Control 85: 100-108. - Lackey, G., Vasylkivska, V., Huerta, N., King, S., and Dilmore, R., 2019. Managing well leakage risks at a geologic carbon storage site with many wells, International Journal of Greenhouse Gas Control, 88 :182-194. - Vasylkivska, V., Dilmore, R., Lackey, G., Zhang, Y., King, S., Bacon, D., Chen, B., Mansoor, K., and Harp, D., 2021. NRAP-Open-IAM: A flexible open-source integrated assessment model for geologic carbon storage risk assessment and management, Environmental Modelling & Software, 143: 105114. Presentations: - Chen, B., Harp, D., and Pawar, R., A data assimilation approach (ES-MDA) coupling with NRAP-Open-IAM for quantifying uncertainty reduction in geological CO2 sequestration. AGUFM 2019: T44A-02. - Chen, B., and Harp, D., Improving risk analysis precision for geologic CO2 sequestration by quantifying the uncertainty reduction before and after acquiring monitoring data. 14th Greenhouse Gas Control Technologies Conference, Melbourne, Australia, 2018, pp. 21-26. - Harp, D., National Risk Assessment Partnership Task 2: Containment Assurance. No. LA-UR-19-28654, Los Alamos National Laboratory (LANL), Los Alamos, NM (United States), 2019. - Vasylkivska, V., King, S., Bacon, D., Harp, D., Chen, B., Mansoor, K., Onishi, T., Yang, Y., Zhang, Y., and Keating, E., NRAP-Open-IAM: An open-source integrated assessment model, poster, Mastering the Subsurface Through Technology Innovation, Partnerships and Collaboration: Carbon Storage and Oil and Natural Gas Technologies Review Meeting, Pittsburgh, PA, August 13-16, 2018. - Vasylkivska, V., Lackey, G., King, S., Wentworth, A., Huerta, N., Creason, C., DiGiulio, J., Yang, Y., and Dilmore, R., Long-term risk analysis of a geologic CO2 storage project during the post-injection period, SIAM Conference on Computational Science and Engineering, Spokane, WA, February 25-March 1, 2019. - Vasylkivska, V., Overview of the NRAP-Open-IAM tool for carbon storage (beta release), 2019 Annual NRAP Tool Users Meeting, Pittsburgh, PA, August 27, 2019. - Vasylkivska, V., Bacon, D., Chen, B., Dilmore, R., Harp, D., King, S., Lackey, G., Lindner, E., Liu, G., Mansoor, K. and Zhang, Y., NRAP-Open-IAM: A new, open-source code for integrated assessment of geologic carbon storage containment effectiveness and leakage risk, poster, American Geophysical Union Fall Meeting 2020 (virtual meeting), December 2020. - Vasylkivska, V., NRAP open-source integrated assessment model and relevant application, oral presentation, NRAP workshop "NRAP Tools for Geologic Carbon Storage Risk-Based Decision Making" held in conjunction with Groundwater Protection Council (GWPC) 2021 Annual Forum (virtual meeting), Salt Lake City, UT, September 2021. - Vasylkivska, V., NRAP-Open-IAM: open-source integrated assessment model, digital poster/demonstration, software demonstration session, 2022 Carbon Management Project Review Meeting, August 16, 2022

AoR↗

Implicit and coupled fluid plasma solver with adaptive Cartesian mesh and its applications to non-equilibrium gas discharges

In this work, we present a new fluid plasma solver with adaptive Cartesian mesh (ACM) based on a full-Newton (nonlinear, implicit) scheme for non-equilibrium gas discharge plasma. The electrons and ions are described using drift-diffusion approximation coupled to Poisson equation for the electric field. The electron-energy transport equation is solved to account for electron thermal conductivity, Joule heating, and energy loss of electrons in collisions with neutral species. The rate of electron-induced ionization is a function of electron temperature and could also depend on electron density (important for plasma stratification). The ion and gas temperature are kept constant. The transport equations are discretized using a non-isothermal Scharfetter-Gummel scheme to resolve possible large temperature gradients in the sheaths. We demonstrate the new solver for simulations of direct current (DC) and radiofrequency (RF) discharges. The implicit treatment of the coupled equations allows using large time steps. The full-Newton method (FNM) enables fast nonlinear convergence at each time step, offering significantly improved simulation efficiency. We discuss the selection of time steps for solving different plasma problems. The new solver enables solving several problems we could not solve before with existing software: two- and three-dimensional structures of the entire DC discharges including cathode and anode regions, electric field reversals and double-layer formation, the normal cathode spot and an anode ring, moving striations in diffuse and constricted DC discharges, and standing striations in RF discharges. The developed FNM-ACM technique offers many benefits for tackling the disparity of gas discharge plasma systems' time scales and nonlinearity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SQMBox: Interfacing a semiempirical integral library to modular ab initio electronic structure enables new semiempirical methods

Ab initio and semiempirical electronic structure methods are usually implemented in separate software packages or use entirely different code paths. As a result, it can be time-consuming to transfer an established ab initio electronic structure scheme to a semiempirical Hamiltonian. Here we present an approach to unify ab initio and semiempirical electronic structure code paths based on a separation of the wavefunction ansatz and the needed matrix representations of operators. With this separation, the Hamiltonian can refer to either an ab initio or semiempirical treatment of the resulting integrals. We built a semiempirical integral library and interfaced it to the GPU-accelerated electronic structure code TeraChem. Equivalency between ab initio and semiempirical tight-binding Hamiltonian terms is assigned according to their dependence on the one-electron density matrix. The new library provides semiempirical equivalents of the Hamiltonian matrix and gradient intermediates, corresponding to those provided by the ab initio integral library. This enables the straightforward combination of semiempirical Hamiltonians with the full pre-existing ground and excited state functionality of the ab initio electronic structure code. We demonstrate the capability of this approach by combining the extended tight-binding method GFN1-xTB with both spin-restricted ensemble-referenced Kohn–Sham and complete active space methods. We also present a highly efficient GPU implementation of the semiempirical Mulliken-approximated Fock exchange. The additional computational cost for this term becomes negligible even on consumer-grade GPUs, enabling Mulliken-approximated exchange in tight-binding methods for essentially no additional cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Overview of the XGAM Code and Related Software for Gamma-ray Analysis

The XGAM spectrum-fitting code and associated software were developed specifically to analyze the complex gamma-ray spectra that can result from neutron-induced reactions. The XGAM code is designed to fit a spectrum over the entire available gamma-ray energy range as a single entity, in contrast to the more traditional piecewise approaches. This global-fit philosophy enforces background continuity as well as consistency between local and global behavior throughout the spectrum, and in a natural way. This report presents XGAM and the suite of programs built around it with an emphasis on how they fit into an overall analysis methodology for complex gamma-ray data. An application to the analysis of time-dependent delayed gamma-ray yields from 235 U fission is shown in order to showcase the codes and how they interact.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methodological Aspects of Shielding and Activation Analyses for ITER Diagnostics Systems - Paper 125

It is expected that the diagnostics systems of the ITER tokamak will provide valuable measurement data about the first in its kind D-T fusion plasma with emission of 14 MeV neutrons. These systems must withstand the neutron and secondary photon radiation along the ITER operation. Under the neutron irradiation the ITER materials are getting radioactive and therefore an adequate shielding must be provided along all the time of ITER operation and shut-down for the reliable machine operation and for the safe personnel access to its components, such as the diagnostics ports. These are the prerequisites for the shielding and activation analysis of the ITER diagnostics systems discussed in this paper. This paper provides insight into the current tasks of neutronics support for the development of ITER diagnostics systems. The tasks themselves range from relatively straightforward ones such as Monte Carlo radiation transport calculations for shielding analyses of the diagnostics systems, to more advanced tasks of Shut-Down Dose Rate (SDDR) analyses for which the dedicated Rigorous 2-Step mesh-based (R2Smesh) and Direct 1-Step (D1S) methodologies were applied. The accuracy and precision of the ITER neutronics analysis is dependent on the methodological approaches and the implying modeling assumptions. In addition to the SDDR challenges, another distinguishing feature of fusion neutronics is a wide use of CAD-based neutronics modeling to design components of fusion devices such as ITER and DEMO. Basically, there are two possibilities of CAD geometry settings in Monte Carlo (MC) radiation transport models, either by the geometry format conversion of CAD models into the format of MC models by means of the interface programs such as McCad and MCAM or by the direct use of CAD geometry engine in MC calculations such as it was realized in the DAGMC code approach. Several conversion interfaces and the DAGMC software library have been tested on the 3D ITER model developed for the CAD-MCNP benchmark. It was concluded that the considered approaches have reached the maturity level to allow their application to real ITER design analyses.

61 RADIATION PROTECTION AND DOSIMETRY↗

An Open-Source Framework for the Computational Analysis and Design of Autothermal Chemical Processes

The main project object was to develop software tools for simulating non-equilibrium autothermal processes, improving the prospects for identifying and designing such systems. The project demonstrates the use of these tools to simulate autothermal pyrolysis, a process recently developed at the pilot-plant scale at Iowa State University. In such process, instead of externally heating a reactor to pro-vide the enthalpy of pyrolysis, sufficient oxygen in the form of air is introduced into the reactor to support partial oxidation of reactants and products with the exothermic energy released supporting endothermic pyrolysis reactions. A fluidized bed is used to assure good mixing of biomass and oxidant and provide an isothermal reaction environment. The amount of oxygen required depends upon the kind of biomass being pyrolyzed and parasitic heat losses from the reactor. For example, for woody biomass pyrolyzed under conditions that simulate adiabatic operation, equivalence ratios can be as low as 0.06, compared to 0.20 or higher for autothermal gasifiers. By removing the heat transfer bottleneck of conventional pyrolysis, operation in autothermal mode allowed a significant increase in reactor throughput process, approaching five times the throughput of the conventionally operated pyrolyzer. Different simulation strategies were considered and developed: a zero-dimensional chemistry model was used to verify the applicability of kinetic schemes to predict biomass fast pyrolysis in autothermal conditions. Conventional chemical reactor models such as the plug flow reactor and the partially stirred reactor were used to investigate the role of mixing in the fluidized bed pyrolyzer and to establish the impact of mixing time on the gas-phase reactions. A comprehensive multiphase computational fluid dynamics (mCFD) framework, including polydisperse granular phase modeling and detailed chemical kinetics was formulated and used to model the experimental setup for autothermal biomass fast pyrolysis at ISU. Multiphase CFD was also used to investigate the role of biomass feed positioning on the mixing of biomass in the pyrolizer. Finally, a reduced order model (ROM), suitable to be implemented in process simulators was obtained. Both the mCFD and the ROM were validated against experiments.

09 BIOMASS FUELS↗

Transient Cold Flow Simulation of Fast Fluidized Bed Fuel Reactors for Chemical-Looping Combustion

Circulating fluidized bed in chemical-looping combustion (CLC) is a recent technology that provides great advantage for gas–solid interaction and efficiency. In order to obtain a thorough understanding of this technology and to assess its effectiveness for industrial scale deployment, numerical simulations are conducted. Computational fluid dynamics (CFD) simulations are performed with dense discrete phase model (DDPM) to simulate the gas–solid interactions. CFD commercial software ansysfluent is used for the simulations. Two bed materials of different particle density and diameter, namely the molochite and Fe100, are used in studying the hydrodynamics and particle behavior in a fuel reactor corresponding to the experimental setup of Haider et al. (2016, “A Hydrodynamic Study of a Fast-Bed Dual Circulating Fluidized Bed for Chemical Looping Combustion,” Energy Technol., 4(10), pp. 1254–1262.) at Cranfield University in the UK. Both the simulations show satisfactory agreement with the experimental data for both the static pressure and volume fraction at various heights above the gas inlet in the reactor. It is found that an appropriate drag law should be used in the simulation depending on the particle size and flow conditions in order to obtain accurate results. Furthermore, the simulations demonstrate the ability of CFD/DDPM to accurately capture the physics of circulating fluidized bed-based CLC process at pilot scale which can be extended to industrial scale projects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-121: Dosimetric Characterization of Gafchromic Film EBT3 Using Vidar DosimetryPro Advantage RED and EPSON Expression 10000XL Scanners

Purpose: The purpose of this paper is to characterize EBT3 using two types of scanner, analyzing the factors of influence of each dosimetry system. Methods: The film used in this study was GAFCHROMIC EBT3, the films were exposed at a dose range between 0Gy a 9Gy in a solid water phantom, SSD=100cm, 5cm depth and perpendicularly to the 6MV photon beam generated by a Novalis TX linear accelerator equipped with an HDMLC. A Farmer type ion chamber TN30013 (PTW) was used to determine the dose delivered to the film. The films were digitized with a scanner EPSON expression 10000XL and the VIDAR DosimetryPro Adventage RED. Software RIT113v6.1 was used for construction of the calibration curve and analysis. The film characteristics investigated were: response at different dose levels, sensitivity to orientation and side and resolution through the results of the spatial response function by analyzing a step pattern. Additionally, 20 IMRT treatment fields were measured with both scanner and compared with calculated dose using gamma index analysis (3%-3mm). Results: The OD obtained for dose level 2Gy in the orientation portrait of the film on the scanner EPSON is (0,222±0,19) and for Vidar RED (0,252±0,10) and landscape is for EPSON (0,211±0,25) and for Vidar RED (0,250±0,11) . The orientation dependence with respect to film side is about 0,09% for EPSON and about 0.03% for VIDAR. The spatial response function increase in response to the Gaussian function FWHM EPSON scanner (0.18mm) compared with VIDAR scanner function (less than 0.06mm) was observed. We analyzed 20 total plan dose distributions the number of pixels with gamma>1 (3%-3mm) was 0.7%±1.2 [0.1%; 2.82%] for EBT3-VIDAR y 2%±2.9 [0.2%; 3.5%] for EBT3-EPSON. Conclusion: VIDAR scanner shows better sensitivity. EBT3 film shows a different response between portrait and landscape orientation. Step pattern is better reproduce by VIDAR scanner.

07 ISOTOPE AND RADIATION SOURCES↗

TH-C-17A-08: Monte Carlo Based Design of Efficient Scintillating Fiber Dosimeters

Purpose: To accurately predict Cherenkov radiation generation in scintillating fiber dosimeters. Quantifying Cherenkov radiation provides a method for optimizing fiber dimensions, orientation, optical filters, and photodiode spectral sensitivity to achieve efficient real time imaging dosimeter designs. Methods: We develop in-house Monte Carlo simulation software to model polymer scintillation fibers' fluorescence and Cherenkov emission in megavoltage clinical beams. The model computes emissions using generation probabilities, wavelength sampling, fiber photon capture, and fiber transport efficiency and incorporates the fiber's index of refraction, optical attenuation in the Cherenkov and visible spectrum and fiber dimensions. Detector component selection based on parameters such as silicon photomultiplier efficiency and optical coupling filters separates Cherenkov radiation from the dose-proportional scintillating emissions. The computation uses spectral and geometrical separation of Cherenkov radiation, however other filtering techniques can expand the model. Results: We compute Cherenkov generation per electron and fiber capture and transmission of those photons toward the detector with incident electron beam angle dependence. The model accounts for beam obliquity and nonperpendicular electron fiber impingement, which increases Cherenkov emission and trapping. The rotational angle around square fibers shows trapping efficiency variation from the normally incident minimum to a maximum at 45 degrees rotation. For rotation in the plane formed by the fiber axis and its surface normal, trapping efficiency increases with angle from the normal. The Cherenkov spectrum follows the theoretical curve from 300nm to 800nm, the wavelength range of interest defined by silicon photomultiplier and photodiode spectral efficiency. Conclusion: We are able to compute Cherenkov generation in realistic real time scintillating fiber dosimeter geometries. Design parameters incorporate fiber dimensions, orientations, several types of detector spectral response, optical coupling filters and light transport. We can vary these parameters to design and optimize high efficiency real time dosimeters capable of enhancing external beam patient safety and treatment accuracy. This research was supported in part by a GAANN Fellowship from the Department of Education.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-83: A Study On Evaluating the Directional Dependency of 2D Seven 29 Ion Chamber Array Clinically with Different IMRT Plans

Purpose: To evaluate the directional dependency of 2D seven 29 ion chamber array clinically with different IMRT plans. Methods: 25 patients already treated with IMRT plans were selected for the study. Verification plans were created for each treatment plan in eclipse 10 treatment planning system using the AAA algorithm with the 2D array and the Octavius CT phantom. Verification plans were done 2 times for a single patient. First plan with real IMRT (plan-related approach) and second plan with zero degree gantry angle (field-related approach). Measurements were performed on a Varian Clinac-iX, linear accelerator equipped with a millennium 120 multileaf collimator. Fluence was measured for all the delivered plans and analyzed using the verisoft software. Comparison was done by selecting the fluence delivered in static gantry (zero degree gantry) versus IMRT with real gantry angles. Results: The gamma pass percentage is greater than 97 % for all IMRT delivered with zero gantry angle and between 95%–98% for real gantry angles. Dose difference between the TPS calculated and measured for IMRT delivered with zero gantry angle was found to be between (0.03 to 0.06Gy) and with real gantry angles between (0.02 to 0.05Gy). There is a significant difference between the gamma analysis between the zero degree and true angle with a significance of 0.002. Standard deviation of gamma pass percentage between the IMRT plans with zero gantry angle was 0.68 and for IMRT with true gantry angle was found to be 0.74. Conclusion: The gamma analysis for IMRT with zero degree gantry angles shows higher pass percentage than IMRT delivered with true gantry angles. Verification plans delivered with true gantry angles lower the verification accuracy when 2D array is used for measurement.

60 APPLIED LIFE SCIENCES↗

WE-F-304-05: Cranial TCP/NTCP Modeling Insights and Caveats

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-00: Outcomes of Hypofractionated Treatments - Results of the WGSBRT

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗