Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Solute Layers and Double-Diffusive Interfaces during the Solidification of NH{sub 4}Cl-H{sub 2}O in Rectangular Cavities

Flow and temperature fields during the solidification of hypereutectic and hypoeutectic NH{sub 4}Cl-H{sub 2}O solution in rectangular cavities were measured by a particle image velocimetry(PIV) and a weak perturbation thermocouple network, respectively. Double-diffusive convections caused by the coupling effects of temperature and solute gradients were studied by the experiment. During the solidification of hypereutectic solution, the rejected water near the solidification interface will lead to dilute solute layers and double-diffusive interfaces. As the continued rejection of water, the layer and interface will evolve into instability and a multi-layer and multi-interface structure will be formed. To the hypoeutectic solution, the rejection of NH{sub 4}Cl near the solidification interface will form a dense solute layer. When the thickness of the dense solute layer is large enough, the coupling effects of stabilizing solute gradient and unstable temperature gradient will lead to new solute layers. The solute layers and double-diffusive interfaces will evolve stably and have no breakup of the double-diffusive interfaces during the solidification of hypoeutectic solution.

36 MATERIALS SCIENCE↗

Hydrogen Adsorption on Activated Carbon an Carbon Nanotubes Using Volumetric Differential Pressure Technique

A simple hydrogen adsorption measurement system utilizing the volumetric differential pressure technique has been designed, fabricated and calibrated. Hydrogen adsorption measurements have been carried out at temperatures 298 K and 77 K on activate carbon and carbon nanotubes with different surface areas. The adsorption data obtained will be helpful in understanding the adsorption property of the studied carbon materials using the fundamentals of adsorption theory. The principle of the system follows the Sievert-type method. The system measures a change in pressure between the reference cell, R1 and the sample cell S1, S2, S3 over a certain temperature range, R1, S1, S2, and S3 having known fixed volume. The sample temperatures will be monitored by thermocouple TC while the pressures in R1 an S1, S2, S3 will be measured using a digital pressure transducer. The maximum operating pressure of the pressure transducer is 20 bar and calibrated with an accuracy of +-0.01 bar. High purity hydrogen is being used in the system and the amount of samples for the study is between 1.0-2.0 grams. The system was calibrated using helium gas without any samples in S1, S2 an S3. This will provide a correction factor during the adsorption process providing an adsorption free reference point when using hydrogen gas resulting in a more accurate reading of the adsorption process by eliminating the errors caused by temperature expansion effects and other non-adsorption related phenomena. The ideal gas equation of state is applied to calculate the hydrogen adsorption capacity based on the differential pressure measurements. Activated carbon with a surface area of 644.87 m{sup 2}/g showed a larger amount of adsorption as compared to multiwalled nanotubes (commercial) with a surface area of 119.68 m{sup 2}/g. This study als indicated that there is a direct correlation between the amounts of hydrogen adsorbed an surface area of the carbon materials under the conditions studied and that the adsorption significant at 77 K.

36 MATERIALS SCIENCE↗

Dynamic T{sub 2}-mapping during magnetic resonance guided high intensity focused ultrasound ablation of bone marrow

Focal bone tumor treatments include amputation, limb-sparing surgical excision with bone reconstruction, and high-dose external-beam radiation therapy. Magnetic resonance guided high intensity focused ultrasound (MR-HIFU) is an effective non-invasive thermotherapy for palliative management of bone metastases pain. MR thermometry (MRT) measures the proton resonance frequency shift (PRFS) of water molecules and produces accurate (<1 Degree-Sign C) and dynamic (<5s) thermal maps in soft tissues. PRFS-MRT is ineffective in fatty tissues such as yellow bone marrow and, since accurate temperature measurements are required in the bone to ensure adequate thermal dose, MR-HIFU is not indicated for primary bone tumor treatments. Magnetic relaxation times are sensitive to lipid temperature and we hypothesize that bone marrow temperature can be determined accurately by measuring changes in T{sub 2}, since T{sub 2} increases linearly in fat during heating. T{sub 2}-mapping using dual echo times during a dynamic turbo spin-echo pulse sequence enabled rapid measurement of T{sub 2}. Calibration of T{sub 2}-based thermal maps involved heating the marrow in a bovine femur and simultaneously measuring T{sub 2} and temperature with a thermocouple. A positive T{sub 2} temperature dependence in bone marrow of 20 ms/ Degree-Sign C was observed. Dynamic T{sub 2}-mapping should enable accurate temperature monitoring during MR-HIFU treatment of bone marrow and shows promise for improving the safety and reducing the invasiveness of pediatric bone tumor treatments.

60 APPLIED LIFE SCIENCES↗

Overview of ion source characterization diagnostics in INTF

INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of heat load density profile on acceleration grid in MeV-class negative ion accelerator

To understand the physics of the negative ion extraction/acceleration, the heat load density profile on the acceleration grid has been firstly measured in the ITER prototype accelerator where the negative ions are accelerated to 1 MeV with five acceleration stages. In order to clarify the profile, the peripheries around the apertures on the acceleration grid were separated into thermally insulated 34 blocks with thermocouples. The spatial resolution is as low as 3 mm and small enough to measure the tail of the beam profile with a beam diameter of ∼16 mm. It was found that there were two peaks of heat load density around the aperture. These two peaks were also clarified to be caused by the intercepted negative ions and secondary electrons from detailed investigation by changing the beam optics and gas density profile. This is the first experimental result, which is useful to understand the trajectories of these particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryostat system for investigation on new neutron moderator materials at reactor TRIGA PUSPATI

A simple continuous flow (SCF) cryostat was designed to investigate the neutron moderation of alumina in high temperature co-ceramic (HTCC) and polymeric materials such as Teflon under TRIGA neutron environment using a reflected neutron beam from a monochromator. Cooling of the cryostat will be carried out using liquid nitrogen. The cryostat will be built with an aluminum holder for moderator within stainless steel cylinder pipe. A copper thermocouple will be used as the temperature sensor to monitor the moderator temperature inside the cryostat holder. Initial measurements of neutron spectrum after neutron passing through the moderating materials have been carried out using a neutron spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feedback system for divertor impurity seeding based on real-time measurements of surface heat flux in the Alcator C-Mod tokamak

Mitigation of the intense heat flux to the divertor is one of the outstanding problems in fusion energy. One technique that has shown promise is impurity seeding, i.e., the injection of low-Z gaseous impurities (typically N 2 or Ne) to radiate and dissipate the power before it arrives to the divertor target plate. To this end, the Alcator C-Mod team has created a first-of-its-kind feedback system to control the injection of seed gas based on real-time surface heat flux measurements. Surface thermocouples provide real-time measurements of the surface temperature response to the plasma heat flux. The surface temperature measurements are inputted into an analog computer that “solves” the 1-D heat transport equation to deliver accurate, real-time signals of the surface heat flux. The surface heat flux signals are sent to the C-Mod digital plasma control system, which uses a proportional–integral–derivative (PID) algorithm to control the duty cycle demand to a pulse width modulated piezo valve, which in turn controls the injection of gas into the private flux region of the C-Mod divertor. This paper presents the design and implementation of this new feedback system as well as initial results using it to control divertor heat flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lower hybrid wave edge power loss quantification on the Alcator C-Mod tokamak

For the first time, the power deposition of lower hybrid RF waves into the edge plasma of a diverted tokamak has been systematically quantified. Edge deposition represents a parasitic loss of power that can greatly impact the use and efficiency of Lower Hybrid Current Drive (LHCD) at reactor-relevant densities. Through the use of a unique set of fast time resolution edge diagnostics, including innovative fast-thermocouples, an extensive set of Langmuir probes, and a Lyα ionization camera, the toroidal, poloidal, and radial structure of the power deposition has been simultaneously determined. Power modulation was used to directly isolate the RF effects due to the prompt (t<τ E ) response of the scrape-off-layer (SOL) plasma to Lower Hybrid Radiofrequency (LHRF) power. LHRF power was found to absorb more strongly in the edge at higher densities. It is found that a majority of this edge-deposited power is promptly conducted to the divertor. This correlates with the loss of current drive efficiency at high density previously observed on Alcator C-Mod, and displaying characteristics that contrast with the local RF edge absorption seen on other tokamaks. Measurements of ionization in the active divertor show dramatic changes due to LHRF power, implying that divertor region can be a key for the LHRF edge power deposition physics. These observations support the existence of a loss mechanism near the edge for LHRF at high density (n e >1.0×10 20 (m -3 )). Results will be shown addressing the distribution of power within the SOL, including the toroidal symmetry and radial distribution. Finally, these characteristics are important for deducing the cause of the reduced LHCD efficiency at high density and motivate the tailoring of wave propagation to minimize SOL interaction, for example, through the use of high-field-side launch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A divertor scraper observation system for the Wendelstein 7-X stellarator

Two graphite divertor elements called scrapers have been installed on the Wendelstein 7-X stellarator in the throat of the magnetic island divertor. To diagnose one, we have designed, built, calibrated, and installed a new infrared/visible imaging endoscope system to enable detailed observations of the plasma interactions and heat loads at one of the scrapers and the nearby divertor surfaces. The new system uses a shuttered pinhole-protected pair of 90° off-axis 228 mm focal length aluminum parabolic mirrors, and two flat turning metal mirrors, to send light to a sapphire vacuum window 1.6 meters away, beyond which we have co-located telephoto lens-based infrared and visible cameras. The back-to-back off-axis parabolas serve to cancel out most aberrations, enabling the use of off-the-shelf commercial optics outside of the vessel. For the infrared, we use a 3-5 μm 1-megapixel FLIR SC8303HD camera and for the visible, a 5-megapixel CMOS PCO 5.5 edge camera. A short 1-m quartz pickoff fiber is used to send 200-1100 nm light to a compact spectrometer, also located in the same iron shield box as the cameras. The camera field of view covers the 700 mm length of the scraper, and includes locations monitored by thermocouples and Langmuir probes embedded in some of the scraper tiles. Predicted and actual optical test performances of the overall system are then compared.

47 OTHER INSTRUMENTATION↗

A simple vacuum suitcase for enabling plasma facing component characterization in fusion devices

We have demonstrated a vacuum suitcase to transport samples in vacuo to a surface analysis station for characterization of tokamak plasma facing components (PFCs). This technique enables surface analysis at powerful, dedicated stations that are not encumbered by design constraints imposed on them by a tokamak. The vacuum suitcase is an alternative solution to characterizing PFCs using diagnostics that are designed and built around a tokamak. The vacuum suitcase, called the Sample Exposure Probe (SEP), features mobile ultra-high vacuum pumping. Active pumping under high vacuum enables sample transfer between the Lithium Tokamak eXperiment-β (LTX-β) and a high resolution X-ray Photoelectron Spectroscopy (XPS) system that is situated close by. A thermocouple inserted in the back of the sample head measures heat flux from the plasma during exposure, and together with a button heater, allows the sample to match the LTX-β PFCs in high temperature operations. As vacuum conditions are better during transfer and analysis than in the tokamak, less contamination is introduced to the samples. XPS scans on a dedicated analysis station enable peak identification due to higher resolution and signal to noise ratio. A similar probe could be implemented for other fusion devices. As a result, the SEP is the first vacuum suitcase implementation for fusion applications that incorporates active pumping.

47 OTHER INSTRUMENTATION↗

Radiation furnace for synchrotron dark-field x-ray microscopy experiments

We present a multi-purpose radiation furnace designed for x-ray experiments at synchrotrons. The furnace is optimized specifically for dark-field x-ray microscopy (DFXM) of crystalline materials at beamline ID06 of the European Synchrotron Radiation Facility. The furnace can reach temperatures above 1200 °C with a thermal stability better than 10 °C, with heating and cooling rates up to 30 K/s. The non-contact heating design enables samples to be heated either in air or in a controlled atmosphere contained within a capillary tube. The temperature was calibrated via the thermal expansion of an α-iron grain. Temperature profiles in the y and z axes were measured by scanning a thermocouple through the focal spot of the radiation furnace. In the current configuration of the beamline, this furnace can be used for DFXM, near-field x-ray topography, bright-field x-ray nanotomography, high-resolution reciprocal space mapping, and limited powder diffraction experiments. As a first application, we present a DFXM case study on isothermal heating of a commercially pure single crystal of aluminum.

Yildirim, C. (ORCID:0000000249690685)↗

Reexamination of hydrodynamic phonon transport in thin graphite

The recent hydrodynamic phonon transport theory for graphitic materials has been supported by the measurements of the second sound at temperatures up to about 100 K. When boundary scattering becomes comparable to momentum-conserving normal phonon scattering processes that are responsible for phonon hydrodynamics, Poiseuille phonon flow phenomena can emerge to give rise to unique size-dependent thermal conductivity in thin graphite. Here, we examine the thickness range for the Poiseuille phonon flow to become observable in thin graphite with the use of both deviational Monte Carlo simulation of the Peierls-Boltzmann transport equation and four-probe thermal transport measurements. As the basal-plane thermal conductivity calculated by prior first-principles theories saturates to the graphite value when the thickness is increased to five graphene layers, the phonon dispersion of graphite is used in the current calculations of thin graphite of micrometer thickness and a 23-layer thick ultrathin graphite (UTG) sample. The calculations show that diffuse surface scattering by surface defects can lead to Poiseuille phonon flow at 50 K in thin graphite with the thickness close to several micrometers but not in the 65 μm thin graphite and 23-layer UTG, where phonon scattering by the top and bottom surfaces become, respectively, much less and more frequent than the normal processes. In addition, the calculation results with the bulk graphite dispersion and diffuse surface scattering show decreased basal-plane thermal conductivity with decreasing thickness, opposite to recent thermocouple measurements of thin graphite samples. In comparison, the calculation results reveal that partially diffuse surface defect scattering can yield the four-probe measurement results of UTG samples, which are prepared here with an improved process to minimize surface contamination.

36 MATERIALS SCIENCE↗

MELCOR Analysis of OSU Multi-Application Small Light Water Reactor (MASLWR) Experiment

A multi-application small light water reactor (MASLWR) conceptual design was developed by Oregon State University (OSU) with emphasis on passive safety systems. The passive containment safety system employs condensation and natural circulation to achieve the necessary heat removal from the containment in case of postulated accidents. Containment condensation experiments at the MASLWR test facility at OSU are modeled and analyzed with MELCOR, a system-level reactor accident analysis computer code. The analysis assesses its ability to predict condensation heat transfer in the presence of noncondensable gas for accidents where high-energy steam is released into the containment. This work demonstrates MELCOR’s ability to predict the pressure-temperature response of the scaled containment. Our analysis indicates that the heat removal rates are underestimated in the experiment due to the limited locations of the thermocouples and applies corrections to these measurements by conducting integral energy analyses along with CFD simulation for confirmation. Furthermore, the corrected heat removal rate measurements and the MELCOR predictions on the heat removal rate from the containment show good agreement with the experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of Advanced Instrumentation for Transient Testing

A fuel safety research program centered on in-pile transient testing experiments is being developed to support assessment and qualification of advanced nuclear fuel systems using the recently restarted Transient Reactor Test (TREAT) facility at the Idaho National Laboratory (INL). While resumption of transient testing at TREAT is crucial to enable these programs, full recovery and cutting-edge transient testing capability also requires a well-coordinated and innovative instrumentation development and qualification program to support near-term and future objectives. This paper summarizes the experimental approach of transient testing to focus on measuring the response of nuclear fuel to off-normal (or power-cooling mismatch) conditions for modern and advanced reactor environments requiring capabilities extending over wide measurement and environment conditions. It also highlights unique attributes of transient testing of importance to in-pile instruments including relatively low total neutron fluence, high gamma heating, and the need for well-defined and possibly short time response. Historical approaches to instrumentation for transient testing are also reviewed to provide context to the modern instrument strategy. The instrumentation needs of a modern transient testing are detailed while summarizing several ongoing R&D activities are supporting the development of state-of-the-art and ‘advanced’ measurement technologies that will provide baseline capability for Light Water Reactor (LWR) and Sodium-Cooled Fast Reactor (SFR) experiment objectives, while extending to other advanced reactor needs and advanced sensing technology opportunities. Examples of specific sensors planned for near-term deployment with ongoing development includes prompt-response self-powered neutron detectors (SPND), miniature fission chambers, optical-fiber-coupled infrared pyrometer, cladding surface thermocouples, electrical-impedance based boiling detector, and Linear Variable Differential Transformer (LVDT) based sensors for fuel elongation and pressure measurement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nonnuclear Experimental Capabilities to Support Design, Development, and Demonstration of Microreactors

This work provides a summary of selected experimental capabilities being developed to support nonnuclear testing and demonstration of technology in support of microreactors under the U.S. Department of Energy’s (DOE’s) Microreactor Program. Major capabilities include the Single Primary Heat Extraction and Removal Emulator (SPHERE) and the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET). The SPHERE facility allows for controlled testing of the steady-state and transient heat rejection capabilities of a single heat pipe using electrical heaters that simulate nuclear heating. The facility is capable of monitoring axial temperature profiles along the heat pipe and surrounding test articles during startup, steady-state operation, and transients. Instrumentation includes noncontact infrared thermal imaging, surface thermocouples, spatially distributed fiber optic temperature and strain sensors, electrical power meters, and a water-cooled, gas-gap calorimeter for quantifying heat rejection from the heat pipe. The facility can be operated under both vacuum and inert-gas conditions. The MAGNET facility is a large-scale, 250-kW electrically heated microreactor test bed to enable nonnuclear experimental evaluation of a variety of microreactor concepts. It can be supplied to electrically heat a scaled section of a microreactor and further test the capabilities of heat rejection systems. The initial MAGNET experiments will support technology maturation and reduce uncertainty and risk associated with the design, operation, and deployment of monolithic heat pipe–based reactors. However, this test bed can broadly be applied to multiple microreactor concepts to evaluate a wide range of thermal-hydraulic and structural phenomena such as interface coupling with power conversion units and other collocated systems. MAGNET can evaluate integral thermomechanical effects during electrical heating of an array of heat pipes in a larger test article. Examples of initial testing will include thermal stresses in the monolith and the impact of debonding of a heat pipe from the core block and how that failure could impact surrounding heat pipes, i.e., understanding the potential for cascading failure. This work also discusses some modeling capabilities that can support experiment design, analysis, and interpretation, including the heat pipe code Sockeye and a comparison of thermal-structural simulations performed using ABAQUS and STAR-CCM+.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensitivity Analysis of Transient Critical Heat Flux by RIA Under High-Pressure Flow Boiling Conditions in TRTL

A reactivity-initiated accident (RIA) is a design-basis accident under which critical heat flux (CHF) is likely to be exceeded. The operational margin for RIAs is currently determined using steady-state CHF lookup tables, which provide conservative estimates relative to transient CHF phenomena. The Transient Reactor Test Loop (TRTL) facility at Oregon State University is capable of performing out-of-pile rapid heating experiments representative of a RIA at conditions representative of a pressurized water reactor (PWR). Here, to further our understanding of and ability to predict transient CHF under PWR conditions, we performed a sensitivity analysis on a RELAP5-3D model of the TRTL facility coupled to the RAVEN code framework to define a proposed experimental test matrix to be performed at the TRTL facility. We then implemented a flow boiling CHF correlation into RELAP5-3D and performed a secondary sensitivity analysis inspecting the impact of the built-in RELAP5-3D CHF and heat transfer multipliers on both the prediction of CHF and key safety parameters, such as peak cladding temperature and heat flux. The results show that the multiplier with the highest influence toward the prediction of CHF occurrence and the safety parameters is the transient CHF multiplier. Operational performance envelopes have been developed for each of the test matrix cases and will be used for validation once the experiments are performed. The TRTL facility is currently performing shakedown testing to verify system performance prior to proceeding with the experimental campaign. Restart testing results include pump curve restart testing, pressure tests, and heater rod thermocouple transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of a Physics-Informed Convolutional Neural Network for Monitoring the Temperature Fields in High-Temperature Gas Reactors

Here, this work presents current advances in applying a physics-informed convolutional neural network (CNN) to evaluate temperature distributions in advanced reactors. Our goal is to demonstrate that the CNN can reconstruct temperature fields within the solid region of a prismatic fuel assembly in a high-temperature gas reactor (HTGR) with sensor data available in only a few cooling channels. Before that, we showcase the superior performance of the physics-informed CNN in comparison to a purely data-driven multilayer perceptron (MLP), considering a canonical heated channel setup. This analysis shows the advantages of our approach and justifies its choice. The datasets employed here are obtained upon numerical simulations performed with codes under the Nuclear Energy Advanced Modeling and Simulation program. This work is important, as industry experience indicates that the assembly material in HTGR concepts is prone to large thermal-mechanical loads nearing operational limits. This makes it crucial to characterize peak temperatures and their distributions near hot spots. Modern thermocouples are unreliable in these types of harsh environments because of the high neutron fluxes and elevated temperatures involved. The CNN-based field reconstruction represents an attractive solution, enabling sensor arrays in less aggressive locations and augmenting indirect predictions for less accessible regions. The results show that the CNN reduces prediction errors by orders of magnitude in comparison to the MLP, considering the simple yet well-representative heated channel case. In the case of the HTGR fuel assembly, the CNN can successfully reconstruct temperature fields over various cooling regimes. Furthermore, we also explore the algorithm’s ability to detect abnormalities. Interestingly, the CNN proves it has the capacity to detect blockage in one of the noninstrumented cooling channels.

Machine learning↗

Experimental analysis of conductive drying of paper and board

The primary heat transfer source in the conventional multi-cylinder drying of paper and board is conduction. Conduction is facilitated by high-tension contact with steam-heated cylinders, while convective drying, the main mass transfer source, operates as heated air flows over the paper web in the pockets. This conduction process occurs at elevated temperatures and contact pressures to ensure effective contact between the wet paper web and the heated cylinders. The contact pressures and temperatures of the hot surface significantly influence the conductive drying characteristics. This research paper presents an experimental study that involves designing a simple lab-scale setup with in-situ and continuous sensing capabilities for various commercially available grades of paper and board. Embedded thermocouples measure the temperatures of the heated platen and the sheet, allowing the collection of flux data to determine heat transfer characteristics. Here, the goal of this study is to ascertain the instantaneous contact coefficients for different basis weights as a function of moisture content. The acquired data will provide valuable insights and information towards process development, design and simulation of the paper drying process.

42 ENGINEERING↗