Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Modulation of auroral electron fluxes in the frequency range 50 kHz to 10 MHz

A sounding rocket-borne electron detector of high time resolution is used to search for modulation of auroral electron fluxes in the frequency range 50 kHz to 10 MHz and energy range 5-7 keV. Data were telemetered to ground via a 93-kHz subcarrier. A cross-correlation analysis of the data collected indicates low-level modulation near the detection threshold of the instrument. Two U-1 events are observed which are interpreted as indications of modulation. The two modulation events occur during a period of increasing flux for a region marking the boundary between two current sheets detected by the payload magnetometer. The strongest argument against interference contamination is the lack of any observable modulation at times other than those mentioned in the study.

Spiger, R. J.↗

Testing Special Relativity at High Energies with Astrophysical Sources

Since the group of Lorentz boosts is unbounded, there is a question as to whether Lorentz invariance (LI) holds to infinitely short distances. However, special and general relativity may break down at the Planck scale. Various quantum gravity scenarios such as loop quantum gravity, as well as some forms of string theory and extra dimension models may imply Lorentz violation (LV) at ultrahigh energies. The Gamma-Ray Large Area Space Telescope (GLAST), to be launched in mid-December, will measure the spectra of distant extragalactic sources of high energy gamma-rays, particularly active galactic nuclei and gamma-ray bursts. GLAST can look for energy-dependent gamma-ray propagation effects from such sources as a signal of Lorentz invariance violation. These sources may also exhibit the high energy cutoffs predicted to be the result of intergalactic annihilation interactions with low energy photons having a flux level as determined by various astronomical observations. With LV the threshold for such interactions can be significantly raised, changing the predicted absorption turnover in the observed spectrum of the sources. Stecker and Glashow have shown that the existence such absorption features in the spectra of extragalactic sources puts constraints on LV. Such constraints have important implications for some quantum gravity and large extra dimension models. Future spaceborne detectors dedicated to measuring gamma-ray polarization can look for birefringence effects as a possible signal of loop quantum gravity. A very small LV may also result in the modification or elimination of the GZK effect, thus modifying the spectrum of ultrahigh energy cosmic rays. This possibility can be explored with ground-based arrays such as Auger or with a space based detector system such as the proposed OWL satellite mission.

Stecker, F. W.↗

Rapidity gap cross sections measured with the ATLAS detector in pp collisions at root s=7 TeV

Pseudorapidity gap distributions in proton-proton collisions at {radical}s = 7 {approx} TeV are studied using a minimum bias data sample with an integrated luminosity of 7.1 {micro}b{sup -1}. Cross sections are measured differentially in terms of {Delta}{eta}{sup F}, the larger of the pseudorapidity regions extending to the limits of the ATLAS sensitivity, at {eta} = {+-}4.9, in which no final state particles are produced above a transverse momentum threshold p{sub T}{sup cut}. The measurements span the region 0 < {Delta}{eta}{sup F} < 8 for 200 {approx} MeV < p{sub T}{sup cut} < 800 {approx} MeV. At small {Delta}{eta}{sup F}, the data test the reliability of hadronization models in describing rapidity and transverse momentum fluctuations in final state particle production. The measurements at larger gap sizes are dominated by contributions from the single diffractive dissociation process (pp {yields} Xp), enhanced by double dissociation (pp {yields} XY) where the invariant mass of the lighter of the two dissociation systems satisfies M{sub Y} {approx}< 7 GeV. The resulting cross section is d{sigma}/d{Delta}{eta}{sup F} {approx}1 mb for {Delta}{eta}{sup F} {approx}>3. The large rapidity gap data are used to constrain the value of the Pomeron intercept appropriate to triple Regge models of soft diffraction. The cross section integrated over all gap sizes is compared with other LHC inelastic cross section measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prompt fission gamma-ray studies at DANCE

Measurements of correlated data on prompt-fission γ-rays (PFG) have been carried out for various actinide isotopes in recent years using the Detector for Advanced Neutron Capture Experiments (DANCE) at Los Alamos National Laboratory (LANL). We have developed a model that conveniently parametrizes the correlated data of γ-ray multiplicity and energy. New results on two- dimensional prompt-fission γ-ray multiplicity versus energy distributions from spontaneous fission on ²⁵²Cf and neutron-induced fission on 242m Am are presented together with previously obtained results on 233,235 U and ²³⁹Pu. Correlated PFG data from ²⁵²Cf are also compared to results of the detailed theoretical model developed at LANL, for different thresholds of PFG energies. Future plans to measure correlated data on fission fragments, prompt fission neutrons and γ-rays at DANCE are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of Born cross sections for e + e − → Λ c + Λ ¯ c ( 2595 ) − + c . c . and e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . at s = 4918.0 and 4950.9 MeV

Using e + e − collision data collected with the BESIII detector operating at the BEPCII collider, the Born cross sections of e + e − → Λ c + Λ ¯ c ( 2595 ) − + c . c . and e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . are measured for the first time at center-of-mass energies of s = 4918.0 and 4950.9 MeV. Nonzero cross sections are observed very close to the production threshold. The measured Born cross sections of e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . are about 2–3 times greater than those of e + e − → Λ c + Λ ¯ c ( 2595 ) − + c . c . , providing the similar behavior as semileptonic decays of Λ b 0 , but different behavior from that in the hadronic decays of Λ b 0 . The Born cross sections are 15.6 ± 3.1 ± 0.9 pb and 29.4 ± 3.7 ± 2.7 pb for e + e − → Λ c + Λ ¯ c ( 2595 ) − + c . c . , and are 43.4 ± 4.0 ± 4.1 pb and 76.8 ± 6.5 ± 4.2 pb for e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . at s = 4918.0 and 4950.9 MeV, respectively. Based on the polar angle distributions of the Λ ¯ c ( 2625 ) − and Λ c ( 2625 ) + , the form-factor ratios | G E | 2 + 3 | G M | 2 / | G C | are determined for e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . for the first time, which are 5.95 ± 4.07 ± 0.15 and 0.94 ± 0.32 ± 0.02 at s = 4918.0 and 4950.9 MeV, respectively. All of these first uncertainties are statistical and second systematic. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

MTRE

Multi-Token Reliability Estimation (MTRE) is a lightweight, white-box hallucination detector for vision-language models. Instead of using only the first output token, MTRE aggregates logits from the first ~10 tokens and feeds them to a small attention-based reliability head; per-token scores are combined via a sequential log-likelihood-ratio test with early-stopping, and an MTRE-t variant calibrates thresholds via cross-fitting. MTRE reports average gains of +9.4% Accuracy and +14.8% AUROC over common baselines across MAD-Bench, MM-SafetyBench, MathVista, and arithmetic/counting tasks, while adding ~4.3M params and ~1% inference overhead (~26 MB VRAM, ~0.94 ms per detection). Key limitation: requires access to early token logits and is evaluated on a handful of open-source 7B VLMs.

Bhattarai, Manish [Los Alamos National Labs]↗

The Modeled Performance of the ORNL Matched Filter Detector for Seismic Signatures of Multi-Axle Tractor Trailers

The MINOS program seeks methods to passively monitor the transfer of special materials, which are reproducible and quantitatively defensible. To date, we have demonstrated that short-period seismometers deployed near vehicle tracks can detect and monitor signatures of multi-axle tractor trailers impacting small road obstacles as means to detect and identify some transfer activities. In this report, we model the seismic velocity signal output from a tractor-trailer impacting a small obstacle (a template waveform) to parameterize a matched filter that identifies signals with similar shapes buried in noise, and that indicate repeating events (target waveforms). We then use this model to perform thousands of synthetic experiments, in which we apply our detector to identify noisy waveforms output from a similarly modeled vehicle data set; we process all data in the same manner as we process real data collected from the Oak Ridge National Laboratory (ORNL) seismic network. Our experiments, while limited, reveal that the matched filter shows a high discrimination capability, and at very low SNR values (at visibility thresholds). This means that template waveforms can match target waveforms that are sourced by models that share the same vehicle speed (target vehicles), and have a low probability of mis-identification. In particular, a matched filter designed to detect a five-axle tractor-trailer will reliably identify that target vehicle down to an SNR of 11.25 dB, and within ±0.1 km/hr, while successfully screening target vehicles with three axles.

42 ENGINEERING↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing neutrino emission at GeV energies from compact binary mergers with the IceCube Neutrino Observatory

The advent of multimessenger astronomy has allowed for new types of source searches by neutrino detectors. Here, we present the results of the search for 0.5–100 GeV astrophysical neutrinos detected with IceCube and emitted from compact binary mergers detected by the LIGO, Virgo, and KAGRA interferometers from their first run of observation (O1) to the end of the first part of the fourth (O4a). An innovative approach is used to lower the energy threshold to 0.5 GeV and to search for an excess of GeV neutrinos in time coincidence with astrophysical transient events. Furthermore, we use a statistical combination of all observations, a binomial test, to search for a subpopulation of neutrino emitters. No significant excess was found from the studied mergers, with a best post-trial 𝑝-value of 40%, and there is currently no hint of a population of GeV neutrino emitters found in the IceCube data (post-trial 𝑝−value=81%).

Abbasi, R. [Loyola University Chicago]↗

High level tritiated water monitoring by Bremsstrahlung counting using a silicon drift detector

The β-ray induced X-ray spectrometry (BIXS) is a promising technique to monitor the tritium concentration in a fuel cycle of a fusion reactor. For in-situ measurements of high level tritiated water by Bremsstrahlung counting, the characteristics of a low-noise silicon drift detector (SDD) have been examined at the Tritium Laboratory Karlsruhe (TLK). In static measurements with constant sample volume and tritium concentration, the Bremsstrahlung spectra of tritiated water samples in a concentration range of 0.02 to 15 MBq/ml have been obtained. The volume has been kept constant at 5 cm{sup 3}. The observed spectra are well above the noise threshold. In addition to X-rays induced by β-rays, the spectra feature X-ray fluorescence peaks of the surrounding materials. No indications of memory effects have been observed. A linear relation between the X-ray intensity and the tritium concentration was obtained and the lower detection limit of the setup has been determined to 1 MBq ml{sup -1}, assessed by the Curie criterion. In addition, the spectra obtained experimentally could be reproduced with high agreement by Monte-Carlo simulations using the GEANT4-tool-kit. It was found that the present detection system is applicable to non-invasive measurements of high-level tritiated water and the SDD is a convenient tool to detect the low energy Bremsstrahlung X-rays. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ANNIE: the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a Gadolinium-loaded water Cherenkov detector placed in the Booster Neutrino Beam (BNB) at the Fermi National Accelerator Laboratory, USA. The primary physics goal of ANNIE is to perform neutrino cross-section measurements that will constrain systematic uncertainties in the next generation of long-baseline neutrino experiments. The first measurement will be the multiplicity of final-state neutrons from neutrino-nucleus interactions in water. Alongside these measurements, ANNIE has achieved the first ever deployments of two novel detector technologies in a neutrino beam: Large Area Picosecond Photodetectors (LAPPDs) and Water-based Liquid Scintillator (WbLS). LAPPDs are micro-channel-plate-based devices that provide timing resolution of ~100 picoseconds and sub-centimeter spatial resolution. WbLS combines the low attenuation and Cherenkov production of pure water with the high light-yield and low detection threshold of liquid scintillator. This talk will discuss the status of ANNIE's physics and R&D measurements.

43 PARTICLE ACCELERATORS↗

Robust power detector for wideband signals among many single tone signals

Various technologies for isolating a signal of interest from signals received contemporaneously by an antenna are described herein. A time period for which a signal of interest is present in a second signal can be identified based upon ratios of values of the second signal to the mean value of the second signal. When the ratio of the value of the second signal at a particular time to the mean of the second signal exceeds a threshold value, the signal of interest is considered to be present in the second signal.

47 OTHER INSTRUMENTATION↗

Robust power detector for wideband signals among many single tone signals

Various technologies for isolating a signal of interest from signals received contemporaneously by an antenna are described herein. A time period for which a signal of interest is present in a second signal can be identified based upon ratios of values of the second signal to the mean value of the second signal. When the ratio of the value of the second signal at a particular time to the mean of the second signal exceeds a threshold value, the signal of interest is considered to be present in the second signal.

47 OTHER INSTRUMENTATION↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation protection for high energy implantation of light ions in a production environment

In recent years the irradiation of semiconductor devices by light ions with high energies has increasingly become a well-established method to adjust charge carrier lifetimes in semiconductor devices. To introduce this process into the end of frontend production environment several measures in terms of radiation safety will have to be obeyed. An overview on thresholds for particles induced gamma emission will be given, starting with the {sup 11}B(p,{gamma}){sup 12}C reaction at 163keV. The environment has to be shielded from gamma rays, therefore those implanters have to be situated in adequate enclosures. Calculations for specific implant energies are done to define the thicknesses of tool enclosures. A set of radiation detectors monitors the values at well-defined positions online and radiation values are fed into a superordinate system that is directly coupled to the main power supply of the implanter.

36 MATERIALS SCIENCE↗

A two-dimensional matrix correction for off-axis portal dose prediction errors

Purpose: This study presents a follow-up to a modified calibration procedure for portal dosimetry published by Bailey et al. ['An effective correction algorithm for off-axis portal dosimetry errors,' Med. Phys. 36, 4089-4094 (2009)]. A commercial portal dose prediction system exhibits disagreement of up to 15% (calibrated units) between measured and predicted images as off-axis distance increases. The previous modified calibration procedure accounts for these off-axis effects in most regions of the detecting surface, but is limited by the simplistic assumption of radial symmetry. Methods: We find that a two-dimensional (2D) matrix correction, applied to each calibrated image, accounts for off-axis prediction errors in all regions of the detecting surface, including those still problematic after the radial correction is performed. The correction matrix is calculated by quantitative comparison of predicted and measured images that span the entire detecting surface. The correction matrix was verified for dose-linearity, and its effectiveness was verified on a number of test fields. The 2D correction was employed to retrospectively examine 22 off-axis, asymmetric electronic-compensation breast fields, five intensity-modulated brain fields (moderate-high modulation) manipulated for far off-axis delivery, and 29 intensity-modulated clinical fields of varying complexity in the central portion of the detecting surface. Results: Employing the matrix correction to the off-axis test fields and clinical fields, predicted vs measured portal dose agreement improves by up to 15%, producing up to 10% better agreement than the radial correction in some areas of the detecting surface. Gamma evaluation analyses (3 mm, 3% global, 10% dose threshold) of predicted vs measured portal dose images demonstrate pass rate improvement of up to 75% with the matrix correction, producing pass rates that are up to 30% higher than those resulting from the radial correction technique alone. As in the 1D correction case, the 2D algorithm leaves the portal dosimetry process virtually unchanged in the central portion of the detector, and thus these correction algorithms are not needed for centrally located fields of moderate size (at least, in the case of 6 MV beam energy).Conclusion: The 2D correction improves the portal dosimetry results for those fields for which the 1D correction proves insufficient, especially in the inplane, off-axis regions of the detector. This 2D correction neglects the relatively smaller discrepancies that may be caused by backscatter from nonuniform machine components downstream from the detecting layer.

60 APPLIED LIFE SCIENCES↗

Short-Pulse Photoneutron Production on Beryllium Using the Mercury Pulsed Power X-ray Source

An x-ray beam can produce neutrons using beryllium as a photoneutron converter because of the relatively low 9 Be(ɤ,n) reaction energy threshold. Previous photoneutron production simulations have focused on using a linear accelerator and heavy water to generate photoneutrons for potential medical therapies. This experimental work focused on creating a short, intense neutron pulse using the Mercury pulsed power machine at the U.S. Naval Research Laboratory, which fired a Bremsstrahlung photon beam with an energy endpoint of 4.8 MeV. Several independent detector systems were included in the experiment to measure both the characteristics of the x-ray pulse and resulting photoneutrons. We discovered the neutron pulse follows the time history of the x-ray pulse, enabling neutron pulses as short as 30 ns with less than 10% shot-to-shot variation. The approach offers a high-flux of neutrons with a higher end-point energy than using a heavy water converter. Previous experiments at Mercury have generated fission neutrons using a higher x-ray endpoint and 238 U(n,f). Results indicate that with an optimized diode and beryllium converter target design, neutron production could be further increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗