Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Spherical Rayleigh-Taylor growth of three-dimensional broadband perturbations on OMEGA

Spherical Rayleigh-Taylor (RT) growth experiments of three-dimensional (3D) broadband nonuniformities were conducted in the acceleration phase of spherical implosions on OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. The targets consisted of 20- and 24-{mu}m-thick plastic spherical shells having diagnostic openings for backlighter x rays to image shell modulations. Experiments were conducted with square laser pulses at a low drive intensity of {approx}2x10{sup 14} W/cm{sup 2}, high drive intensity of {approx}1x10{sup 15} W/cm{sup 2}, and a shaped pulse consisting of a low-intensity foot and high-intensity drive part (peak intensity of {approx}1x10{sup 15} W/cm{sup 2}). In low-intensity experiments, large RT growth was measured, resulting in shells being broken up by 3D modulations at the end of the drive. In the high-intensity experiments, no RT growth of the 3D modulations was detected. In the shaped-pulse experiments, perturbations grew during the low-intensity part of the drive and were stabilized later during the high-intensity part of the drive. The measured RT growth stabilization with the high-intensity drive was similar to previous observations in planar geometry [V. A. Smalyuk et al., Phys. Rev. Lett. 101, 025002 (2008)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Backscattering of Relativistic Electrons Incident on a Planar Foil at a Small Angle to Its Surface

Photographs of cross sections of an electron beam backscattered from a thin tungsten target have been obtained on a dosimetric film. The procession of images makes it possible to obtain the spatial distribution of backscattered particles. The angles of back reflection θ{sub br} of electron beams from foils have been measured. A 7.4-MeV microtron has been used as a source of electrons. The experiments have been performed with a tungsten foil 386 mg/cm{sup 2} (200 μm) thick and a tantalum foil 1328 mg/cm{sup 2} (800 μm) thick. Particles have been injected at an angle of α = 10° to the foil surface. The Monte Carlo simulation of the scattering of relativistic electrons incident on a planar target at small angles to its surface has been performed. The spatial and energy distributions of backscattered particle fluxes both transmitted through the target and reflected from it have been calculated. The dependences of fluxes on the direction of injection of particles and on the material and thickness of the target have been considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Postmastectomy radiotherapy with integrated scar boost using helical tomotherapy

The purpose of this study was to evaluate helical tomotherapy dosimetry in postmastectomy patients undergoing treatment for chest wall and positive nodal regions with simultaneous integrated boost (SIB) in the scar region using strip bolus. Six postmastectomy patients were scanned with a 5-mm-thick strip bolus covering the scar planning target volume (PTV) plus 2-cm margin. For all 6 cases, the chest wall received a total cumulative dose of 49.3-50.4 Gy with daily fraction size of 1.7-2.0 Gy. Total dose to the scar PTV was prescribed to 58.0-60.2 Gy at 2.0-2.5 Gy per fraction. The supraclavicular PTV and mammary nodal PTV received 1.7-1.9 dose per fraction. Two plans (with and without bolus) were generated for all 6 cases. To generate no-bolus plans, strip bolus was contoured and overrode to air density before planning. The setup reproducibility and delivered dose accuracy were evaluated for all 6 cases. Dose-volume histograms were used to evaluate dose-volume coverage of targets and critical structures. We observed reduced air cavities with the strip bolus setup compared with what we normally see with the full bolus. The thermoluminescence dosimeters (TLD) in vivo dosimetry confirmed accurate dose delivery beneath the bolus. The verification plans performed on the first day megavoltage computed tomography (MVCT) image verified that the daily setup and overall dose delivery was within 2% accuracy compared with the planned dose. The hotspot of the scar PTV in no-bolus plans was 111.4% of the prescribed dose averaged over 6 cases compared with 106.6% with strip bolus. With a strip bolus only covering the postmastectomy scar region, we observed increased dose uniformity to the scar PTV, higher setup reproducibility, and accurate dose delivered beneath the bolus. This study demonstrates the feasibility of using a strip bolus over the scar using tomotherapy for SIB dosimetry in postmastectomy treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Stripe domains and spin reorientation transition in Fe{sub 78}B{sub 13}Si{sub 9} thin films produced by rf sputtering

Magnetic thin films have been obtained by rf sputtering from an amorphous Fe{sub 78}B{sub 13}Si{sub 9} target. The samples have been produced with thickness t ranging in the interval 25-1000 nm. Microstructural investigations indicate that the films have different microstructures varying from fully amorphous to partially nanocrystalline with increasing t. Magnetic hysteresis loops have been measured by means of high-sensitive magnetometry. A tailorable spin reorientation transition (SRT) from in-plane single-domain-like to out-of-plane multidomain state with increasing film thickness was observed. Magnetic force microscopy images have been obtained for all samples indicating that for t{<=}80 nm the magnetization lies in the film plane. For larger thickness, a stripe domain pattern has been observed, indicating the presence of a magnetic anisotropy axis perpendicular to the film plane. In this work, SRT and stripe domain structure have been studied as a function of thickness and sample microstructure.

36 MATERIALS SCIENCE↗

Monoenergetic proton emission from nuclear reaction induced by high intensity laser-generated plasma

A 10{sup 16} W/cm{sup 2} Asterix laser pulse intensity, 1315 nm at the fundamental frequency, 300 ps pulse duration, was employed at PALS laboratory of Prague, to irradiate thick and thin primary CD{sub 2} targets placed inside a high vacuum chamber. The laser irradiation produces non-equilibrium plasma with deutons and carbon ions emission with energy of up to about 4 MeV per charge state, as measured by time-of-flight (TOF) techniques by using ion collectors and silicon carbide detectors. Accelerated deutons may induce high D-D cross section for fusion processes generating 3 MeV protons and 2.5 MeV neutrons, as measured by TOF analyses. In order to increase the mono-energetic proton yield, secondary CD{sub 2} targets can be employed to be irradiated by the plasma-accelerated deutons. Experiments demonstrated that high intensity laser pulses can be employed to promote nuclear reactions from which characteristic ion streams may be developed. Results open new scenario for applications of laser-generated plasma to the fields of ion sources and ion accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics

Image guided radiation therapy solutions based on megavoltage computed tomography (MVCT) involve the extension of electronic portal imaging devices (EPIDs) from their traditional role of weekly localization imaging and planar dose mapping to volumetric imaging for 3D setup and dose verification. To sustain the potential advantages of MVCT, EPIDs are required to provide improved levels of portal image quality. Therefore, it is vital that the performance of EPIDs in clinical use is maintained at an optimal level through regular and rigorous quality assurance (QA). Traditionally, portal imaging QA has been carried out by imaging calibrated line-pair and contrast resolution phantoms and obtaining arbitrarily defined QA indices that are usually dependent on imaging conditions and merely indicate relative trends in imaging performance. They are not adequately sensitive to all aspects of image quality unlike fundamental imaging metrics such as the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) that are widely used to characterize detector performance in radiographic imaging and would be ideal for QA purposes. However, due to the difficulty of performing conventional MTF measurements, they have not been used for routine clinical QA. The authors present a simple and quick QA methodology based on obtaining the MTF, NPS, and DQE of a megavoltage imager by imaging standard open fields and a bar-pattern QA phantom containing 2 mm thick tungsten line-pair bar resolution targets. Our bar-pattern based MTF measurement features a novel zero-frequency normalization scheme that eliminates normalization errors typically associated with traditional bar-pattern measurements at megavoltage x-ray energies. The bar-pattern QA phantom and open-field images are used in conjunction with an automated image analysis algorithm that quickly computes the MTF, NPS, and DQE of an EPID system. Our approach combines the fundamental advantages of linear systems metrics such as robustness, sensitivity across the full spatial frequency range of interest, and normalization to imaging conditions (magnification, system gain settings, and exposure), with the simplicity, ease, and speed of traditional phantom imaging. The algorithm was analyzed for accuracy and sensitivity by comparing with a commercial portal imaging QA method (PIPSPRO, Standard Imaging, Middleton, WI) on both first-generation lens-coupled and modern a-Si flat-panel based clinical EPID systems. The bar-pattern based QA measurements were found to be far more sensitive to even small levels of degradation in spatial resolution and noise. The bar-pattern based QA methodology offers a comprehensive image quality assessment tool suitable for both commissioning and routine EPID QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Jurassic deserts and CO2 sequestration: the Glen Canyon Group in Utah, western USA

The Early Jurassic in the Western Interior of USA consisted of an extensive desert environment, including one of the largest ergs in geologic history. The Navajo erg has been estimated to extend as much as 2.2 million square kilometers, though the preserved extent is somewhat smaller. The Mesozoic was a global greenhouse phase, and during the Jurassic this region experienced fluctuations in climate aridity, reflected in the depositional environment. In addition to extensive dunefields, interdune deposits (lakes and oases) and fluvial systems are also documented within formations of the Glen Canyon Group. The Navajo Sandstone has received much attention as a potential CO2 injection target in recent years. It consists of thick, aeolian sandstones with high porosity and permeability, occurs in both outcrop and subcrop, and has industry data. Mapping of stratigraphic and sedimentologic changes within the Navajo Sandstone has been undertaken in localized areas, however piecing together these studies and developing regional models for CO2 potential has not received as much attention. There is significant industry data across Utah, and utilizing this data to pivot from a focus on hydrocarbon extraction to CO2 injection is an effective way to move forward with green energy, and to meet carbon neutral emission goals. Using legacy well data, we are developing a more comprehensive study of the Navajo Sandstone as a potential CO2 reservoir, in addition to identifying other zones of interest within the Glen Canyon Group, and improving understanding of stratigraphic complexity within one of the most significant aeolian systems in the world.

Mahon, Elizabeth↗

Effect of Surface Engineering on LaAlO3/SrTiO3 Interfaces

Carrier properties at the LaAlO3/SrTiO3 interfaces are highly sensitive to potential profile generated by LaAlO3 top surface termination. In ambient environment, the uncontrolled surface exposure may introduce randomly distributed charge or polarization and therefore significantly impact interfacial transport by disorder related effect. As evidence, local fluctuation in carrier density and mobility has been observed in nanostructures defined by atomic force microscope (AFM) lithography. Here we report controlled modification of LaAlO3 surface by solvent deposition. Surface desorption is first carried out by sample annealing in O2 environment. The annealed LaAlO3 surfaces are later coated with various solvents of controlled thicknesses by pulsed laser deposition using frozen targets. Coated surfaces are analyzed by pulsed force and frictional force microscopy. AFM lithography is also carried out to locally alter the surface charge state and modulate the potential disorder level. Effect of different controlled surface coatings on interface are studied by magneto-transport measurement

Adhikari, Sanjay↗

Nb3Sn Superconducting Radiofrequency Cavity Fabricated by Sputter Deposition from a Stoichiometric Target

Nb$_3$Sn is a promising coating material for superconducting radiofrequency cavities in next-generation accelerators due to its higher superconducting transition temperature (~18.3 K) and superheating field (~400 mT), offering the potential to surpass the intrinsic performance limits of bulk niobium. We developed a sputter coating technique employing a stoichiometric target to fabricate Nb$_3$Sn films on the inner surfaces of niobium cavities. A Nb$_3$Sn tube target, prepared by growing a >20 m thick Nb$_3$Sn coating on the surface of a Nb tube via a Sn vapor diffusion process, was used in a DC cylindrical magnetron sputtering system. Approximately 170 nm thick Nb-Sn films were sputter-coated onto flat Nb substrates positioned to replicate the beam tube and equator regions of a 2.6 GHz cavity, followed by annealing at 950 °C for 3 hours to form Nb$_3$Sn. The composition, morphology, and structure of the annealed Nb$_3$Sn films were examined. Then, a ~1.2 m-thick film was sputter-coated onto the interior of a 2.6 GHz Nb cavity following the procedure developed for the flat samples. The cavity was subsequently annealed under the same conditions used for the flat samples. Cryogenic RF testing of the sputter-coated cavity demonstrated a T$_c$ of approximately 17.8 K, consistent with Nb$_3$Sn layer. Subsequently, the cavity underwent a light Sn recoating followed by a vapor diffusion Nb$_3$Sn coating process, achieving a quality factor of approximately 8.5 × 10$^9$ and an accelerating gradient of up to 11.3 MV/m at 4.2 K.

Shakel, Md Sharifuzzaman [Old Dominion U.; Jeffers↗

Development of High Performance Composite Foam Insulation with Vacuum Insulation Cores

Development of a high performance thermal insulation (thermal resistance or R-value per inch of R-12 hr-ft2- F/Btu-in or greater), with twice the thermal resistance of state-of-the-art commercial insulation materials ( R6/inch for foam insulation), promises a transformational impact in the area of building insulation. In 2010, in the US, the building envelope-related primary energy consumption was 15.6 quads, of which 5.75 quads were due to opaque wall and roof sections; the total US consumption (building, industrial and transportation) was 98 quads. In other words, the wall and roof contribution was almost 6% of the entire US primary energy consumption. Building energy modeling analyses have shown that adding insulation to increase the R-value of the external walls of residential buildings by R10-20 (hr-ft2- F/Btu) can yield savings of 38-50% in wall-generated heating and cooling loads. Adding R20 will require substantial thicknesses of current commercial insulation materials, often requiring significant (and sometimes cost-prohibitive) alterations to existing buildings. This article describes the development of a next-generation composite insulation with a target thermal resistance of R25 for a 2 inch thick board (R12/inch or higher). The composite insulation will contain vacuum insulation cores, which are nominally R35-40/inch, encapsulated in polyisocyanurate foam. A recently-developed variant of vacuum insulation, called modified atmosphere insulation (MAI), was used in this research. Some background information on the thermal performance and distinguishing features of MAI has been provided. Technical details of the composite insulation development and manufacturing as well as laboratory evaluation of prototype insulation boards are presented.

Biswas, Kaushik↗

Biological shield design and analysis of KIPT accelerator-driven subcritical facility.

Argonne National Laboratory of the United States and Kharkov Institute of Physics and Technology of Ukraine have been collaborating on the conceptual design development of an electron accelerator-driven subcritical facility. The facility will be utilized for performing basic and applied nuclear research, producing medical isotopes, and training young nuclear specialists. This paper presents the design and analyses of the biological shield performed for the top section of the facility. The neutron source driving the subcritical assembly is generated from the interaction of a 100-kW electron beam with a natural uranium target. The electron energy is in the range of 100 to 200 MeV, and it has a uniform spatial distribution. The shield design and the associated analyses are presented including different parametric studies. In the analyses, a significant effort was dedicated to the accurate prediction of the radiation dose outside the shield boundary as a function of the shield thickness without geometrical approximations or material homogenization. The MCNPX Monte Carlo code was utilized for the transport calculation of electrons, photons, and neutrons. Weight window variance-reduction techniques were introduced, and the dose equivalent outside the shield can be calculated with reasonably good statistics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Freestanding film structures for laser plasma experiments

The technique is developed for fabricating 5-500-nm-thick freestanding films of various materials and multilayer compositions. Apart from the traditional use in spectral filtration of soft X-ray and extreme ultraviolet radiation, the possibility of using the ultrathin films fabricated by this technique as targets in experiments on laser acceleration of ions is considered. A sample of the target in the form of a 5-nm-thick carbon film on a supporting net is fabricated. (extreme light fields and their applications)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Deposition of thin Bi{sub 2}Te{sub 3} and Sb{sub 2}Te{sub 3} films by pulsed laser ablation

Bi{sub 2}Te{sub 3} and Sb{sub 2}Te{sub 3} films were obtained by pulsed laser ablation. The films were deposited in vacuum (1 x 10{sup -5} Torr) on single crystal substrates of Al{sub 2}O{sub 3} (0001), BaF{sub 2} (111), and fresh cleavages of KCl or NaCl (001) heated to 453-523 K. The films were 10-1500 nm thick. The structures of the bulk material of targets and films were studied by X-ray diffractometry and transmission high-energy electron diffraction, respectively. Electrical properties of the films were measured in the temperature range of 77-300 K. It is shown that the films possess semiconductor properties. Several activation portions are observed in the temperature dependences of resistivity; the energies of activation portions depend on the film thickness and crystallite size.

36 MATERIALS SCIENCE↗

Analysis of the Operation of Thermonuclear Inverted-Corona Targets with an Ultrathin Working Layer at the Iskra-5 Laser Facility

We report on the results of experiments performed on the Iskra-5 laser facility for studying the effect of the polydeuteroethylene (CD{sub 2}){sub n} working layer thickness on the operation parameter of an inverted-corona target. In all experiments of this series, the neutron yield at a level of 10{sup 7}–3 × 10{sup 8} DD neutrons per shot was detected for the total laser radiation energy supplied to the target by 12 second-harmonic beams in the range of 1.6–2.2 kJ. Using the neutron time-of-flight technique, we have detected an increase in the ion temperature from approximately 6.4 to 14 keV upon a decrease in the (CD{sub 2}){sub n} layer thickness from 1 to 0.1 μm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computational study of tungsten and depleted uranium photoneutron targets for a 20 MeV electron linear accelerator

Neutron production can be realized with a high energy electron linear accelerator by using Bremsstrahlung and photoneutron converters. In this study, Monte Carlo N-Particle Code (MCNP) was used to evaluate potential photonuclear target designs for a high energy electron linear accelerator for applications such as neutron radiography and neutron resonance spectroscopy. A computational model was developed to inform a target design that would yield a high number of neutrons. It consists of a 20 MeV electron beam incident on a Bremsstrahlung target and a photonuclear target to generate neutrons. This computational model showed that a thickness of 0.75 inches for both tungsten and depleted uranium yields the most neutrons from photoneutron reactions. Saturation in the total number of generated neutrons was observed at over 0.75-inch thickness for both evaluated materials. Depleted uranium yielded approximately twice the number of neutrons overall compared to tungsten. The highest neutron surface flux for Depleted Uranium was 1.06 × 10-4 neutrons/cm2/source electron, and for Tungsten it was 5.12 × 10-5 neutrons/cm2/source electron. The optimal target design for this study’s application would consist of a 0.75 inch-thick block of depleted uranium with the length, width, and/or diameter varying dependent on application.

43 PARTICLE ACCELERATORS↗

Missile impact craters (White Sands Missile Range, New Mexico) and applications to lunar research: Contributions to astrogeology

Craters in natural materials at White Sands Missile Range, N. Mex., were produced by the impact of high-velocity to hypervelocity missiles traveling along oblique trajectories with kinetic energies between 2.1 and 81 × 1014 ergs. The oblique impacts produce craters 2 to 10 m across with morphologies and ejecta that are bilaterally symmetrical with respect to the plane of the missile trajectory. Rims are high and the amount of ejecta large in down-trajectory and lateral directions, whereas rims are low to nonexistent and ejecta thin to absent up-trajectory. Symmetry development and modifications of the symmetry are a function of target material, local topography, and angle of impact. Seven mappable units can be recognized in and around the craters. Three of these are ejecta: thick ejecta near the crater, thin to discontinuous ejecta at greater distances, and scattered ejecta at the greatest distances to the limit of throwout. These ejecta units may be absent on the up-trajectory side; if present, they are rarely as thick or continuous as on other sides of the crater. Three units are target materials: undeformed target material exposed in local patches through thin to discontinuous ejecta and everywhere between the fragments of scattered ejecta, tilted and broken target material exposed in upper crater walls, and shattered and fractured target material exposed on the up-trajectory crater wall. The seventh unit is slope material composed of talus and fallback within the crater. Development, character, and exposure of these units varies chiefly with the target material. Ejecta from the craters is chiefly broken but relatively undeformed target material that may range in size from very fine grained debris to large blocks. Where the target is porous, significant amounts of the ejecta are composed of sheared and compressed fragments, some coated with dark layers of mixed projectile pieces, powder, and fused metal mixed with crushed target material. For layered targets, the original stratigraphic sequence is crudely preserved and in inverted order in thick ejecta. Secondary impact craters are produced by the impact of ejected fragments when the surrounding surface materials are sufficiently weak. A wide variety of secondary impact crater relations may result. Secondary craters nearest the primary crater have blocks in them that are larger than or the same size as the crater they produced. Farther from the primary crater, the fragments are generally smaller than the secondary crater and are ejected from it. Excavation of four craters revealed a mixed breccia beneath the crater floor composed of missile pieces, sheared and compressed target material, and crushed debris. Banded, disaggregated target material and nonmixed breccia surrounded the mixed breccia, and these breccias were surrounded by a zone of conjugate fractures. Beneath the ejecta on the lateral and down-trajectory crater flanks, the target materials were tilted upward and broken. Up-trajectory, open fractures and downward displacement occurred in two of the craters. No displacement was observed for the other two. Beneath the down-trajectory rims of craters with distinct layering, overturned synclines were observed. Missile breakup and behavior during cratering are a function of target and missile properties. Missile breakup depends on missile velocity and is most extensive at high velocities, where the missile is fragmented, powdered, and partly fused. Burial of missile or its fragmented, powdered, and fused remains is greatest for porous targets and least for dense cohesive targets. For very porous targets, camouflet structures containing the fragmented missile may form. Least squares fit to the data on craters in dry to moist targets indicate V(a) = 10^(-11.433)E(p)^(1.205) where V(a) is the volume of the apparent crater and E(p) is the kinetic energy of the missile. This equation is consistent with expectations of the equations relating apparent depth and radius to kinetic energy. Extrapolation of displaced masses and kinetic energies for laboratory impacts with sand and rock converge near 10^(15) to 10^(16) ergs, where the extrapolations are near the data on missile impact craters, corrected for impact angle. Displaced masses of craters produced by missile impacts and by chemical explosives with small scaled depths of burial are about the same when the kinetic energies of the missiles (corrected for angle of impact) are equal to the TNT equivalent energy of the explosive. The problem of equivalent scaled depth of burst for an impact crater is complicated and not entirely resolved, however. Both missile impact craters and chemical explosive craters in water-saturated targets are larger than their counterparts in dry to moist materials. Data collected during the study of missile impact craters have helped resolve a number of problems in lunar research: (1) the soillike nature of lunar surface materials was predicted, (2) sizes of craters produced by artificial impacts were correctly predicted, (3) certain features imaged by Surveyor were found to be analogous to features associated with missile impact craters, {4) missile impacts were used in support of the Apollo passive seismic experiment, (5) craters seen in Apollo orbital photographs were found to be similar to some missile impact craters, (6) missile impact craters supplied data on sample collection and crater phenomenology used in training astronauts, and (7) some returned lunar samples are similar to coated, sheared, and compressed fragments ejected from missile impact craters.

H. J. Moore↗