Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Constant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Resolution of electron emission mechanisms in an argon arc with a hot tungsten cathode

The regenerative nature of the interaction between the electron emission processes at the cathode surface and the ion-, excited-atom-, and photon-production processes in the plasma was examined. Semiquantitative estimates of the thickness of the species production layer, the current partition, and the time constants were made. These results were used to interpret experimental measurements of the current decay of an argon arc at 46.7 kPa, 3.2-7.9 A, and 28-18 V, with a self-sustained hot tungsten cathode. After the discharge is suddenly connected to a voltage clamp, the disparity of decay rates for different emission processes permits the separation of thermionic emission from the faster-decaying components. The observed thermionic current constitutes about 30% of the total emission. The high nonthermionic portions of the current could not be explained in terms of the present understanding of the emission processes.

Chen, M. M.↗

On the design of optimal controllers with certain structural constraints

This paper considers the problem of designing certain structurally constrained optimal regulators for linear systems subjected to additive white process noise and measurement noise. Three types of controller structures are considered, using direct output feedback, prespecified time constant filters, and optimal dynamic compensators. Necessary conditions are obtained for minimizing quadratic performance criteria. The techniques are demonstrated by application to a helicopter/slung load system, and a flexible space station.

Joshi, S. M.↗

Optimal control of spin-stabilized spacecraft with telescoping appendages

The control of a spin-stabilized spacecraft consisting of a rigid central hub and one or two movable offset telescoping booms (with end masses) is considered. The equations of rotational motion are linearized about either of two desired final states. A control law for the boom end mass position is sought such that a quadratic cost functional involving the weighted components of angular velocity plus the control is minimized when the final time is unspecified and involves the solution of the matrix Riccati algebraic equation. For three axis control more than one offset boom (orthogonal to each other) is required. For two-axis control with a single boom offset from a symmetrical hub, an analytic solution is obtained; when this system is used for nutation decay the time constant is one order of magnitude smaller than previously achieved using nonoptimal control logic. For the general case results are obtained numerically.

Bainum, P. M.↗

Submillisecond measurements of the low state of Cygnus X-1

Cygnus X-1 was observed on two occasions separated by a year by the same Goddard X-ray rocket payload. High-resolution temporal and spectral data reveal that Cyg X-1 was essentially unchanged in these two observations a year apart; the bursts of millisecond duration observed in the earlier flight were observed in the second as well. Analysis of these bursts has failed to reveal any internal temporal structure, either luminous or spectral. The shot-noise character of temporal fluctuations on time scales of at least 1 s can be explained by the presence of exponential pulses with a time constant of a fraction of a second and a rate near 8 per sec. The possible connection of these pulses with the bursts is examined.

Rothschild, R. E.↗

Measurement of the nitric oxide altitude distribution in the mid-latitude mesosphere

A simple rocket-borne system has been developed for deriving nitric oxide concentration in the mesosphere from measurements of resonantly scattered solar ultraviolet radiation in the NO gamma band near 2150 A. The NO signal is extracted from a background of Rayleigh-scattered light by a direct measurement of this scattered light by use of an NO absorption cell. This system was utilized to measure the NO concentration above White Sands, New Mexico, in the altitude range from 69 to 101 km. The derived NO profile shows a concentration of about 30 million per cu cm at 67 and 100 km with a deep valley (more than an order of magnitude less) at about 84 km. Comparison with model calculations indicates that the time constant for NO chemistry is smaller than or comparable with that for transport.

Baker, K. D.↗

Thermal performance of a hot-air solar collector

Report contains procedures and results of thermal-performance tests on double-glazed air solar collector. Four types of tests were carried out including thermal-efficiency and stagnation tests, collector time-constant tests to assess effects of transients, and incident-angle modifier tests. Data are presented in tables and as graphs and are discussed and analyzed.

Source record↗

Performance evaluations of a liquid solar collector

Report presents procedures and results of thermal performance tests on single-covered liquid solar collector under simulated comditions. Test conditions and data are given in tables and graphs for stagnation tests and thermal performance test. In addition, time-constant test and incident-angle modifier test were conducted to determine transient effect and incident-angle effect. Results of collector load tests are also given.

Shih, K.↗

Evaluation of an air solar collector

Performance verification under simulated conditions tested by using Marshall Space Flight Center solar simulator is presented. Evaluation included thermal performance tests, time constant tests, and incident angle modifier tests.

Source record↗

Indoor test for thermal performance evaluation of Libbey-Owens-Ford solar collector

The thermal performance of a flat plate solar collector that uses liquid as the heat transfer medium was investigated under simulated conditions. The test conditions and thermal performance data obtained during the tests are presented in tabular form, as well as in graphs. Data obtained from a time constant test and incident angle modifier test, conducted to determine transient effect and the incident angle effect on the collector, are included.

Shih, K.↗

Thermal performance evaluation of Solar Energy Products Company (SEPCO) 'Soloron' collector tested outdoors

The test article, Model EF-212, Serial Nr. 002, is a single glazed collector with a nonselective absorber plate, using flowing air as the heat transfer medium. The absorber plate and box frame are aluminum and the insulation is one inch isocyanurate foam board with thermal conductivity of 0.11 (BTU/sq ft Hr0/ft.) The tests included the following. (1) time constant test, (2) collector efficiency test, (3) collector stagnation test, (4) incident angle modifier test, (5) load test, (6) weathering test, and (7) absorber plate optical properties test. The results of these tests are tabulated, graphed, or otherwise recorded.

Chiou, J., Sr.↗

Indoor test for thermal performance evaluation of Lenox-Honeywell solar collector

The test procedures used and the test results obtained from an evaluation test program conducted on a double-covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using liquid as the heat transfer medium. The absorber plate was steel with the copper tubes bonded on the upper surface. The plate was coated with black chrome with an absorptivity factor of .95 and emissivity factor of .12. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

Shih, K.↗

Indoor thermal performance evaluation of Daystar solar collector

The test procedures used and results obtained from a test program to obtain thermal performance data on a Daystar Model 21B, S/N 02210, Unit 2, liquid solar collector under simulated conditions are described. The test article is a flat plate solar collector using liquid as a heat transfer medium. The absorber plate is copper and coated with black paint. Between the tempered low iron glass and absorber plate is a polycarbonate trap used to suppress convective heat loss. The collector incorporates a convector heat dump panel to limit temperature excursions during stagnation. The following tests were conducted: (1) collector thermal efficiency; (2) collector time constant; (3) collector incident angle modifier; (4) collector heat loss coefficient; and (5) collector stagnation.

Shih, K., Sr.↗

Indoor test for thermal performance evaluation of Sunworks (liquid) solar collector

Test procedures used and test results obtained from an evaluation test program conducted on a single covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using water as the heat transfer medium. The absorber plate was copper with copper tubes bonded by soft solder. The plate was coated with Enthone selective black with an absorptivity factor of .87 approximately .92 and an emissivity factor of .10 approximately .20. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

Shih, K.↗

Indoor test for thermal performance evaluation of the Solaron (air) solar collector

The test procedure used and the results obtained from an evaluation test program, conducted to obtain thermal performance data on a Solaron double glazed air solar collector under simulated conditions in a solar simulator are described. A time constant test and incident angle modifier test were also conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed. The Solaron collector absorber plate is made of 24-gage steel, the coating is baked-on black paint, the cover consists of two sheets of 1/8-inch low-iron tempered glass, and the insulation is one thickness of 3 5/8-inch fiberglass batting.

Source record↗

Indoor test for thermal performance evaluation on the Sunworks (air) solar collector

The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on a Sunworks single glazed air solar collector under simulated conditions are described. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed.

Source record↗

Indoor test for thermal performance evaluation on life sciences engineering (air) solar collector

The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on a life sciences double-glazed air solar collector under simulated conditions is discussed. These tests were made using the Marshall Space Flight Center's solar simulator. A time constant test and incident angle modifier test were also conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed.

Source record↗

G-seat system step input and sinusoidal response characteristics

The step input and sinusoidal response characteristics of a pneumatically driven computer controlled G set are examined in this study. The response data show that this system can be modeled as a first order system with an 0.08 sec time lag and a 0.53 sec time constant.

Showalter, T. W.↗