Search NASA⌕ Search

SEARCH · Search NASA

Results for “Two Phase Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Two-Phase Turbulence Statistics from High Fidelity Dispersed Droplet Flow Simulations in a Pressurized Water Reactor (PWR) Sub-Channel with Mixing Vanes

In the dispersed flow film boiling regime (DFFB), which exists under post-LOCA (loss-of-coolant accident) conditions in pressurized water reactors (PWRs), there is a complex interplay between droplet dynamics and turbulence in the surrounding steam. Experiments have accredited particular significance to droplet collision with the spacer-grids and mixing vane structures and their consequent positive feedback to the heat transfer recorded in the immediate downstream vicinity. Enabled by high-performance computing (HPC) systems and a massively parallel finite element-based flow solver—PHASTA (Parallel Hierarchic Adaptive Stabilized Transient Analysis)—this work presents high fidelity interface capturing, two-phase, adiabatic simulations in a PWR sub-channel with spacer grids and mixing vanes. Selected flow conditions for the simulations are informed by the experimental data found in the literature, including the steam Reynolds number and collision Weber number (Wec={40,80}), and are characteristic of the DFFB regime. Data were collected from the simulations at an unprecedented resolution, which provides detailed insights into the continuous phase turbulence statistics, highlighting the effects of the presence of droplets and the comparative effect of different Weber numbers on turbulence in the surrounding steam. Further, axial evolution of droplet dynamics was analyzed through cross-sectionally averaged quantities, including droplet volume, surface area and Sauter mean diameter (SMD). The downstream SMD values agree well with the existing empirical correlations for the selected range of Wec. The high-resolution data repository from the simulations herein is expected to be of significance to guide model development for system-level thermal hydraulic codes.

Saini, Nadish↗

Experimental investigation of a simulated LOX injector flow field

Current development of liquid oxidizer injectors for liquid rocket engines is highly dependent upon experimental investigations of the two-phase liquid oxidizer/gaseous fuel injection plume characteristics. This paper describes an effort to increase the applicability of optical diagnostic approaches to such flow fields find includes an innovative approach for interpreting laser-induced fluorescence signals from axisymmetric two-phase flows. The usefulness of both laser-induced fluorescence and surface scattering techniques are explored herein. The flow field selected for this investigation is an oxidizer-swirled, coaxial flow produced using an injector design under consideration for use in the Space Transportation Main Engine (STME). The liquid oxygen (LOX) flow through this injector is simulated using water. Photographs of laser-induced fluorescence and particle scattering and measured profiles of the mass distribution in this flow field are presented and discussed herein.

Hartfield, Roy J., Jr.↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗

Application of the principle of similarity fluid mechanics

The principle of similarity applied to fluid mechanics is described and illustrated. The concept of transforming the conservation equations by combining similarity principles for thermophysical properties with those for fluid flow is examined. The usefulness of the procedure is illustrated by applying such a transformation to calculate two phase critical mass flow through a nozzle.

Hendericks, R. C.↗

FY24 Report on Water NSTF Testing: Lower Tank Inlet Piping Configuration

The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.

42 ENGINEERING↗

FY-24 Progress on Computational Modeling of the Water Based NSTF

This report summarizes the computational modeling of the Natural Convection Shutdown Heat Removal Test Facility (NSTF) completed in FY24. This year’s modeling campaign focuses on the continual testing of the RELAP5 model against experimental data. Several fault cases were simulated with the RELAP5 model in FY23 to study the accuracy of the model under complex flow conditions. Similarly, in FY24, a case is simulated where the chimney outlet is throttled with a valve while the flow is undergoing two-phase oscillations. The purpose of this case is to study the effects of increasing pressure drop in the two-phase region on the system behavior. Even though the model is able to capture the experimental data qualitatively, it overpredicts the pressure drops experienced by the flow in the two-phase regime. Nevertheless, the model and the experiment show that oscillations are stabilized with increased pressure drop in the two-phase region.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Eddy Current Flow Meter Measurements and Modeling Validation

The goal of the eddy current flow meter (ECFM) is to monitor velocities and temperatures of conductive liquid metals. The ECFM can also detect voids in two-phase liquid metal flows. Measurement of these flows can greatly improve the accuracy of the empirical formulas used for fluid dynamics near the reactor core and aid in mapping any non-uniformities in fluid flow such as estimates of temperature and phase. While the eventual goal is to develop the ECFM for the liquid sodium surrounding the Versatile Test Reactor (VTR) core, this report focuses on modeling and experimental validation of ECFM for a moving solid test rod and for liquid mercury in the Target Test Facility (TTF) flow loop to better understand and further develop ECFM measurement capabilities by validating model predictions with benchmark experiments. Eventually the models could be used to design and optimize future ECFMs for specific applications such as monitoring flow within the VTR pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental studies of flow separation and stalling on two-dimensional airfoils at low speeds. Phase 2: Studies with Fowler flap extended

Results were given on experimental studies of flow separation and stalling on a two-dimensional GA(W)-1 17 percent thick airfoil with an extended Fowler flap. Experimental velocity profiles obtained from a five tube probe survey with optimum flap gap and overlap setting (flap at 40 deg) are shown at various stations above, below, and behind the airfoil/flap combination for various angles of attack. The typical zones of steady flow, intermittent turbulence, and large scale turbulence were obtained from a hot wire anemometer survey and are depicted graphically for an angle of attack of 12.5 deg. Local skin friction distributions were obtained and are given for various angles of attack. Computer plots of the boundary layer profiles are shown for the case of the flap at 40 deg. Static pressure contours are also given. A GA(W)-2 section model was fabricated with 30 percent Fowler flaps and with pressure tabs.

Seetharam, H. C.↗

Proceedings of the 25th International Instrumentation Symposium, May 7-10, 1979, Anaheim, California

The papers deal essentially with the instrumentation needs of the transportation industry, machinery diagnostics, and energy research. The sessions covered include: acoustic emission, reentry vehicle ground and flight testing, performance of nose tip materials, instrumentation for solar heating and cooling systems, vibration measurement, data acquisition and analysis, system for aerospace pressure measurements, wind tunnel instrumentation and control, energy source instrumentation, nondestructive testing, pressure and flow measurements, automated test facilities, strain measurements, electrooptical instrumentation, thermal measurements, microcomputer applications in instrumentation and automation, flight testing, blast pressure measurement, two-phase liquid/gas mass flow measurement, and machinery monitoring and instrumentation.

Conferences↗

A Comparison of System Architectures for a Mechanically Pumped Two-Phase Thermal Control System

The NASA Jet Propulsion Laboratory is developing a mechanically pumped two-phase fluid loop thermal control system to enable novel mission designs and greater science return. Pumped two-phase fluid loops have the potential to provide robust and effective thermal control that combine the best aspects of passive two-phase systems (heat pipes) and mechanically pumped single-phase fluid loops. The current program requirements include the development of a system with multiple 1 sq.m evaporators, each of which is capable of remaining spatially and temporally isothermal while accommodating heat loads of up to 500 W and local fluxes of up to 5 W/sq.cm. The goal is to attain this using less than 5 W of power. Such a system would be able to accommodate the next generation of payload and bus electronics while using minimal resources. This paper compares two different mechanically pumped two-phase fluid loop architectures in the context of these requirements. A mixed flow and separated flow architecture are compared on a theoretical and experimental basis. Test data from sub-scale, single evaporator/single condenser, mixed flow and separated flow testbeds are presented. In addition, a model is introduced to better understand separated flow systems and some expressions for the theoretical performance limits of such systems are developed. To date, the investigation suggests that a separated flow architecture is better suited to the program requirements. Separated flow systems have the potential to accommodate an isothermalizing two-phase evaporator while using lower levels of power than would be required for a mixed flow system. In addition, it is argued that separated flow systems are more robust and amenable to analysis than mixed flow systems, since they significantly reduce the occurrence of two-phase flow by separating phases in the evaporator. Future work will include developing a full-scale testbed that includes multiple evaporators and condensers in a representative flight configuration.

Furst, Benjamin↗

Commercialization Opportunity SFAI: An acoustic-based method for measuring composition and flow in containers, vessels, and pipes

The need to accurately discern the characteristics of materials within closed containers non-invasively is a problem that plagues many industrial sectors. In particular, characterizing multi-phase flow in pipes and other infrastructure is an ongoing challenge for many industries. Swept Frequency Acoustic Interferometry, or SFAI, and related technologies represent a portfolio that uses high-frequency sound to characterize liquids, gasses, mixtures, emulsions, and other fluids inside pipes and containers. SFAI offers the potential to measure material characteristics and two -and three -phase flows within pipes including flow rates and water- and gas-volume fractions. Such measurements can take place noninvasively both in accessible infrastructure and potentially downhole.

47 OTHER INSTRUMENTATION↗

Preliminary Design Study for an Eddy Current Flow Meter for Versatile Test Reactor

The eddy current flow meter (ECFM) serves the purpose of monitoring velocities and temperatures of conductive liquid coolant surrounding nuclear reactor cells. The ECFM can also detect voids in two-phase liquid metal flows. Measurement of this flow in reactor cells can greatly improve the accuracy of the empirical formulas used for fluid dynamics near the reactor core, as well as, aid in mapping any non-uniformities in fluid flow, its temperature estimation and phase. With modeling and experimental verification, an extensible ECFM for multiple facilities and environments can lead to an understanding of the liquid coolant flow; while saving cost of calibration and development. This can be done by characterizing the ECFM performance based on its parameters and then optimizing a sensor for a given use case. Simulation results using an ECFM and an aluminum rod medium are presented and discussed herein. Additionally, liquid metal simulations for Mercury and Galinstan will compare the ECFM behavior for different liquid velocities and excitation frequencies. After sensor calibration curves are generated and experimentally verified, ECFMs can be developed and deployed using the model introduced.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Turbulence measurements of high shear flow fields in a turbomachine seal configuration

The mean velocity and Reynolds stress tensor throughout a whirling annular seal are presented. The data was collected with a three dimensional laser Doppler velocimeter using phase averaging. Two axial flow conditions (Re = 12,000 and 24,000) were studied at one shaft speed (Ta = 6,600). The eccentricity and whirl ratios were 50 and 100 percent, respectively. There is a region of high axial momentum in this region is higher in the low Reynolds number case due to an axial recirculation zone that occurs on the suction side of the rotor at the inlet. The recirculation zone does not occur in the high Reynolds number case. At both Reynolds numbers, there is a recirculation zone on the rotor surface in the pressure side of the inlet. This recirculation zone extends from 20 to 200 degrees rotor zenith in the tangential direction, and is one third of a clearance wide radially. The high Reynolds number recirculation zone is 1.5 mean clearances long, while the low Reynolds number zone extends 2 mean clearances downstream. When compared to previous studies, it is apparent that the tangential momentum is no greater for a seal with whirl than for one without if other parameters are constant. Areas of high tangential momentum occur in the clearance where the axial momentum is low. Average exit plane tangential velocities in the high Reynolds number case are 1.5 times greater than those in the other flow case. These results are in general agreement with predictions made by other investigators.

Morrison, Gerald L.↗

Numerical Modeling of the Chilldown of Cryogenic Transfer Lines Using a Sinda/GFSSP Integrated Solver

An important first step in cryogenic propellant loading is the chilldown of transfer lines. During the chilldown of the transfer line, the flow is two-phase and unsteady, with solid to fluid heat transfer and therefore a coupled thermo-fluid analysis is necessary to model the system. This paper describes a numerical model of pipe chilldown that utilizes the Sinda/GFSSP Conjugate Integrator (SGCI). SGCI is a new analysis tool developed at NASA's Marshall Space Flight Center (MSFC). SGCI facilitates the solution of thermofluid problems in interconnected solid-fluid systems. The solid component of the system is modeled in MSC Patran and translated into an MSC Sinda thermal network model. The fluid component is modeled in GFSSP, the Generalized Fluid System Simulation Program. GFSSP is a general network flow solver developed at NASA/MSFC. GFSSP uses a finite-volume approach to model fluid systems that can include phase change, multiple species, fluid transients, and heat transfer to simple solid networks. SGCI combines the GFSSP Fortran code with the Sinda input file and compiles the integrated model. Sinda solves for the temperatures of the solid network, while GFSSP simultaneously solves the fluid network for pressure, temperature, and flow rate. The two networks are coupled by convection heat transfer from the solid wall to the cryogenic fluid. The model presented here is based on a series of experiments conducted in 1966 by the National Bureau of Standards (NBS). A vacuum-jacketed, 200 ft copper transfer line was chilled by liquid nitrogen and liquid hydrogen. The predictions of transient temperature profiles and chilldown time of the integrated Sinda/GFSSP model will be compared to the experimental measurements.

LeClair, Andre↗

Oil and gas flow through fractures and along interfaces in well cement

A number of wells at the Strategic Petroleum Reserve (SPR) have shown sustained, positive pressure (referred to as sustained casing pressure or SCP) in the cemented annulus behind the production casing. To better understand how SCP may develop for SPR conditions, we conducted gas and oil flow tests on cement specimens with flaws including cement fractures and discrete interfaces along a cement-steel contact. Many specimens were tested initially with gas, followed by oil, and finally with gas again to identify how the fluid type may affect the flow through flaws in the well cement. Nitrogen was used as the gas, and silicone oil with properties similar to typical crude oil was used in most tests. One set of measurements were made with crude oil. Composite steel-cement specimen with corroded steel were also tested. For both gas and oil tests, the measured flow test data were used to interpret permeability and, assuming the cubic law for flow between parallel plates, the corresponding hydraulic aperture of the flaw. The hydraulic apertures for the flawed specimens ranged from about 20 to >100 μm, which corresponds to permeabilities of about 10 -14 to 10 -12 m 2 , respectively; these hydraulic apertures are consistent with the range of values interpreted from field measurements on leaky wells. Observed differences between the flow of gas and oil were attributed to a number of factors, including non-linear flow of gas, possible blocking of flow paths by solids within the crude oil, two-phase gas and oil flow and the presence of residual oil in the cement flaw. Furthermore, we determined that corroded steel itself is permeable. Using input values consistent with the gas and oil flow measurements, we conducted one-dimensional simulations of gas and oil flow through cemented annulus systems to investigate the role of flaw size and fluid type on the expected response (i.e., pressure build-up) in the annular cement.

02 PETROLEUM↗

High Performance Computing to Enable Next-Generation Low-Temperature Waste Heat Recovery

US manufacturing industry fails to recover an estimated 900 trillion BTUs of low-temperature waste heat from its processes each year. A grand research challenge has been to develop waste heat recovery technology that can be applied to industrial manufacturing processes and vehicle operations. The Oak Ridge National Laboratory (ORNL)/Eaton research team performed computational research and development to design an innovative direct-contact heat exchanger (DCHE) technology to deliver low-cost, compact, longer-lifetime, high-efficiency waste heat recovery that is optimized for a low-temperature organic Rankine cycle. ORNL resources and expertise in high performance computing (HPC) and multiphase flows were utilized to realize this goal while advancing the fundamental understanding of two-phase, two-immiscible-fluid turbulent flow heat transfer for heat exchangers. In the first stage of the project, a computational fluid dynamics (CFD) model of a DCHE was developed. Verification and limited validation of the numerical solution were performed using experimental data from published literature. To support efforts in verification and validation, two-dimensional CFD models were also developed with the objective of investigating different boundary conditions to reach converged, steady-state solutions.Based on benchmarking efforts, a baseline industry-grade design of a DCHE was developed, which consists of two horizontal pipes of different cross-sectional areas – joined by a converging-diverging nozzle in the middle and relies on a three-phase system with co-current flows for operation. Evaporation of the cold liquid (n-pentane or methanol) by the hot liquid water occurs in the first pipe. The first pipe contains two inlets for liquid water and liquid pentane (or liquid methanol). The second pipe with the larger cross-sectional area serves as a gravity-driven phase-separator. It contains two outlets that are staggered to avoid entrainment of the liquid water phase by the gas phase. This baseline design resulted from several trial-and-error evaluations using two-dimensional CFD models. Confirmatory three-dimensional CFD models were also run for different mass flow rates and inlet temperatures (inlet water temperature ranging from 50°C to 90°C), and efficiency plots were produced to fully characterize the proposed industrial-grade design of the DCHE.

97 MATHEMATICS AND COMPUTING↗

Low-speed inducers for cryogenic upper-stage engines

Two-phase, low-speed hydrogen and oxygen inducers driven by electric motors and applicable to the tug engine were designed and constructed. The oxygen inducer was tested in liquid and two-phase oxygen. Its head and flow performance were approximately as designed, and it was able to accelerate to full speed in 3 seconds and produce its design flow and head. The analysis of the two-phase data indicated that the inducer was able to pump with vapor volume fractions in excess of 60 percent. The pump met all of its requirements (duration of runs and number of starts) to demonstrate its mechanical integrity.

Bissell, W. R.↗