Search NASA⌕ Search

SEARCH · Search NASA

Results for “WORKING FLUID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

An electrohydrodynamic heat pipe

Dielectric liquid for transfer of heat provides liquid flow from the condenser section to the evaporator section in conventional heat pipes. Working fluid is guided or pumped by an array of wire electrodes connected to a high-voltage source.

Jones, T. B.↗

Status of power generation experiments in the NASA Lewis closed cycle MHD facility

The design and operation of the closed cycle MHD facility is discussed and results obtained in recent experiments are presented. The main components of the facility are a compressor, recuperative heat exchanger, heater, nozzle, MHD channel with 28 pairs of thoriated tungsten electrodes, cesium condenser, and an argon cooler. The facility has been operated at temperatures up to 2100 K with a cesium-seeded argon working fluid. At low magnetic field strengths, the open circuit voltage, Hall voltage and short circuit current obtained are 90, 69, and 47 percent of the theoretical equilibrium values, respectively. Comparison of this data with a wall and boundary layer leakage theory indicates that the generator has shorting paths in the Hall direction.

Sovie, R. J.↗

Design and preliminary testing of a Brayton space radiator concept

A low-temperature radiator has been designed to reject 17.62 kW of thermal power from an isotope Brayton power system. This power system has an electrical output of 7.1 kW. The total radiator consists of two radiators connected in series. Both radiators have a redundant coolant loop, shared fins, and are close to flight configuration. A silicone oil is used as the working fluid. Low flow rates and moderate pressure drop in the radiator required a small hydraulic diameter with large heat transfer area and large flow area. To obtain these characteristics and meet schedule limitations, an expanded tube configuration (with an approximately trapezoidal cross section) was selected. Because of the low flow rates and unconventional tube shape, small scale tests were performed to evaluate the validity of existing heat transfer and pressure drop correlations to this case. The results of these tests were in good agreement with predictions.

Miller, T. J.↗

Preliminary performance of a 4.97-inch radial turbine operating in a Brayton power system with a helium-xenon gas mixture

The performance characteristics of the Brayton-rotating-unit's 4.97-inch radial turbine were investigated with the turbine part of a power conversion system. The following system parameters were varied: turbine inlet temperature from 1200 to 1600 F, compressor inlet temperature from 60 to 120 F, compressor outlet pressure from 20 to 45 psia, and shaft speed from 90-110 percent of rated speed (36000 rpm). The working fluid of the system was a gas mixture of helium-xenon with a nominal molecular weight of 83.8. Test results indicate that changes in system conditions have little effect on the turbine efficiency. At the design turbine inlet temperature of 1600 F and compressor inlet temperature of 80 F, an average turbine efficiency of 91 percent was obtained.

Leroy, M. J., Jr.↗

Steady-state temperature distribution within a Brayton rotating unit operating in a power conversion system using helium-xenon gas

The Brayton rotating unit (BRU), consisting of a turbine, an alternator, and a compressor, was tested as part of a Brayton cycle power conversion system over a side range of steady state operating conditions. The working fluid in the system was a mixture of helium-xenon gases. Turbine inlet temperature was varied from 1200 to 1600 F, compressor inlet temperature from 60 to 120 F, compressor discharge pressure from 20 to 45 psia, rotative speed from 32 400 to 39 600 rpm, and alternator liquid-coolant flow rate from 0.01 to 0.27 pound per second. Test results indicated that the BRU internal temperatures were highly sensitive to alternator coolant flow below the design value of 0.12 pound per second but much less so at higher values. The armature winding temperature was not influenced significantly by turbine inlet temperature, but was sensitive, up to 20 F per kVA alternator output, to varying alternator output. When only the rotational speed was changed (+ or - 10% of rated value), the BRU internal temperatures varied directly with the speed.

Johnsen, R. L.↗

Brayton heat exchange unit development program

A Brayton Heat Exchanger Unit (BHXU), consisting of a recuperator, a heat sink heat exchanger and a gas ducting system, was designed, fabricated, and tested. The design was formulated to provide a high performance unit suitable for use in a long-life Brayton-cycle powerplant. A parametric analysis and design study was performed to establish the optimum component configurations to achieve low weight and size and high reliability, while meeting the requirements of high effectiveness and low pressure drop. Layout studies and detailed mechanical and structural design were performed to obtain a flight-type packaging arrangement. Evaluation testing was conducted from which it is estimated that near-design performance can be expected with the use of He-Xe as the working fluid.

Morse, C. J.↗

Design and fabrication of the Brayton rotating unit

The Brayton rotating unit (BRU), operating on a gas bearing system, has been designed, fabricated, and demonstrated for use in a closed Brayton cycle space power conversion system. The BRU uses a binary mixture of xenon and helium (molecular weight, 83.8) as the cycle working fluid and bearing lubricating medium and was designed to produce from 2.25 to 10.5 kw sub e of 1200 Hz three-phase electrical power. The single-shaft rotating assembly operates at a design speed of 36,000 rpm and comprises a radial single-stage compressor, a four-pole Rice alternator rotor, and a radial inflow turbine. Four units, a dynamic simulator and three component research packages, were supplied to the NASA Lewis Research Center for performance testing and further development.

Davis, J. E.↗

Arterial and grooved cryogenic heat pipes.

Tests were conducted on two cryogenic heat pipes using nitrogen as the working fluid. Both pipes are 1.27 cm in diameter. The first pipe is 141 cm long and uses longitudinal grooves in the aluminum wall as the wick structure. The second pipe is 91 cm long and has an arterial wick adjacent to the wall. In addition, circumferential screw threads are machined along the entire length of the inside pipe wall. Both heat pipes primed with no difficulty in the horizontal position. Start-up after burn-out was obtained repeatedly. However, more testing is required to determine whether the artery pipe is as reliable as the grooved pipe with respect to priming. Once primed, the artery heat pipe is much less sensitive to elevation than the grooved design and, consequently, offers a significant advantage with respect to ground testing. Heat-transfer characteristics of the two pipes were comparable, with both pipes achieving the initial goal of 1000 watt-cm of heat-transport capability.

Brennan, P.↗

Status of power generation experiments in the NASA Lewis closed-cycle MHD facility.

In this paper the design and operation of the closed-cycle MHD facility is discussed and results obtained in recent experiments are presented. The main components of the facility are a compressor, recuperative heat exchanger (preheater), heater, nozzle, MHD channel with 28 pairs of thoriated tungsten electrodes, cesium condenser, and an argon cooler. The heater can supply 1.1 MW of thermal power to a 2.27 kg/sec gas stream. The facility has been operated at temperatures up to 2100 K with a cesium-seeded argon working fluid. At low magnetic field strengths (B = 0.2 T), the open circuit voltage, Hall voltage and short circuit current obtained are 90, 69, and 47 percent of the theoretical equilibrium values, respectively. The Hall voltage and short circuit current decrease sharply with increasing magnetic field strength, however. Comparison of these data with a wall and boundary layer leakage theory indicates that the generator has shorting paths in the Hall direction.

Sovie, R. J.↗

Development of a self-priming high-capacity heat pipe for flight on OAO-C.

This paper describes the development of a 0.500-inch OD heat pipe with a spiral artery designed to fill under surface tension forces in a one-g field. Capacities in excess of 12,000 watt-inches have been achieved with ammonia as the working fluid. The paper presents the analysis, design, and test of the three-foot-long development models. Also included are some design and fabrication details, along with qualification ground test data for a 12-foot-long spiral artery isothermalizer type heat pipe that is installed on the Orbiting Astronomical Observatory C Model scheduled for launch in 1972.

Edelstein, F.↗

Development of a thermal diode heat pipe for the advanced thermal control flight experiment /ATFE/.

Description of the analysis, design, fabrication, and test of the engineering model of the ATFE diode. Included is a review of several diode concepts that led to selection of the liquid blockage technique for shut-off. The diode is made of stainless steel, 26 in. long, 0.375-in. nominal OD, with self-filling spiral artery wick and ammonia working fluid. In the normal heat pipe mode, at ambient temperatures, the diode capacity is 85 W. For flight, the pipe will deliver 20 W with a 9 F temperature difference between the external evaporator and condenser surfaces. Reverse mode conduction is less than 1.5 W with a 260 F temperature difference.

Swerdling, B.↗

A tunnel wick 100,000 watt-inch heat pipe.

The tunnel wick is a new type of heat pipe artery which can prime in a gravity environment by temperature-induced pressure differences between interior and exterior. The paper discusses the concept and its application in the design of room-temperature high-transport-capacity heat pipes. The analytical model of the system is summarized; and performance data obtained with the aid of a related computer program is included. Test data verifying the concept is presented for several pipes, including an eight-foot-long, 0.9-inch ID heat pipe, using ammonia working fluid, with a transport capacity in excess of 150,000 watt-inches. A brief discussion of potential applications for this type of heat pipe includes a variable conductance device to serve as a radiator header and a high capacity heat transport system.

Kosson, R.↗

Dispersive waves in a seeded MHD generator.

The equations giving the response of a slightly ionized plasma with monatomic components to sinusoidal perturbations have been formulated. Included in the model equations were the electron Hall effect, electron thermal diffusion, radiation, and electron-atom rate processes. Plasma conditions were limited to those where viscous effects, the induced magnetic field, ion slip, and atom-atom inelastic processes can be neglected. Presented are results of numerical calculations for MHD generators with a working fluid of potassium seeded argon.

Harstad, K. G.↗

Program for calculating total-efficiency of specific-speed characteristics of centrifugal compressors

Program uses one-dimensional mean streamline analysis conducted at fixed stagnation conditions. Seven specific losses are calculated for each set of compressors geometric variables and inlet velocity diagram characteristics studied. Categories used as input information are compressor geometry, thermodynamic properties of working fluid, velocity diagram characteristics, and iteration limits.

Galvas, M. R.↗

Effect of a reduction in blade thickness on performance of a single stage 20.32 centimeter mean diameter turbine

As part of a program to reduce the manufacturing costs of a small gas-turbine engine, the turbine blading was reduced in thickness to facilitate coining. Tests were made to determine the effect of this modification on turbine performance. The working fluid was air at nominal inlet total conditions of 535 deg F and 20.0 psia. Performance results are presented and compared for four stator-rotor combinations in terms of equivalent torque, mass flow, and efficiency at equivalent design speed and at inlet-total to exit-static pressure ratios of 1.8 to 3.8

Nusbaum, W. J.↗

Effect of reducing rotor blade inlet diameter on the performance of a 11.66-Centimeter radial-inflow turbine

The effect of increased rotor blade loading on turbine performance was investigated by reducing rotor blade inlet diameter. The reduction was made in four stages. Each modification was tested with the same stator using cold air as the working fluid. Results are presented in terms of equivalent mass flow and efficiency at equivalent design rotative speed and over a range of pressure ratios. Internal flow characteristics are shown in terms of stator exit static pressure and the radial variation of local loss and rotor-exit flow angle with radius ratio. Included are velocity diagrams calculated from the experimental results.

Kofskey, M. G.↗

Use of a torsional pendulum as a high-pressure gage and determination of viscosity of helium gas at high pressures

Three torsional crystal parameters were examined for suitability in sensing pressure in gases up to 131 million newtons per square meter. The best parameters were found to be the change in crystal decrement at resonance and the change in crystal electrical resistance at resonance. The change in crystal resonant frequency did not appear to be a reliable pressure measuring parameter. Pure argon and pure helium gases were studied for use as working fluids. Helium functioned better over a wider pressure range. Calibration of the gage also provided a measure of the viscosity-density product of the gas as a function of pressure. These data, together with known extrapolated density data, permitted the determination of the viscosity of helium to 131 million N/square meter.

Maisel, J. E.↗

Theoretical analysis of oxygen diffusion at startup in an alkali metal heat pipe with gettered alloy walls

The diffusion of oxygen into, or out of, a gettered alloy exposed to oxygenated alkali liquid metal coolant, a situation arising in some high temperature heat transfer systems, was analyzed. The relation between the diffusion process and the thermochemistry of oxygen in the alloy and in the alkali metal was developed by making several simplifying assumptions. The treatment is therefore theoretical in nature. However, a practical example pertaining to the startup of a heat pipe with walls of T-111, a tantalum alloy, and lithium working fluid illustrates the use of the figures contained in the analysis.