Signatures of hot electrons and fluorescence in Mo Kα emission on Z

Recent experiments on the Z accelerator have produced high-energy (17 keV) inner-shell K-alpha emission from molybdenum wire array z-pinches. Extensive absolute power and spectroscopic diagnostics along with collisional-radiative modeling enable detailed investigation into the roles of thermal, hot electron, and fluorescence processes in the production of high-energy x-rays. We show that changing the dimensions of the arrays can impact the proportion of thermal and non-thermal K-shell x-rays.

74 ATOMIC AND MOLECULAR PHYSICS↗

(U) A Theoretical Study of Asay Foil Trajectories (V.02)

We consider the trajectory of a generic Asay foil ejecta momentum diagnostic sensor, for scenarios where ejecta are produced at a planar surface and fly ballistically through a perfect vacuum to the sensor. To do so, we build upon a previously established mathematical formalism derived for the analytic study of stationary sensors (i.e., piezopins). First, we derive the momentum conservation equation for the problem, in a form amenable to accelerating sensors, in terms of a generic ejecta source areal mass function (“source model”). This defines an integro-differential equation (IDE) for the foil trajectory. When ejecta production is instantaneous - as is generally assumed in momentum diagnostic data analyses - the IDE leads to an implicit and easily calculable closed-form solution for the foil trajectory in a perfect system, as long as the ejecta particle velocity distribution is twice-integrable. General properties of the instant-production trajectory solution indicate the existence of a boundary condition the particle velocity distribution must satisfy in order for the analytically predicted foil trajectories to be compatible with certain features commonly observed in foil data. This boundary condition is identical to one derived previously from a consideration of piezopin data. Armed with the analytic solution for instant production, we also consider various techniques used to extract time-dependent cumulative ejecta masses from foil trajectories, and derive an expression for the error imposed by using an approximated equation of motion. This analytic trajectory solution furthermore makes it possible to examine the common practice of presenting inferred cumulative ejecta masses as a function of a normalized implied velocity; we derive conditions under which this methodology is and is not meaningful. We also propose a strategy for extending the instant-production trajectory solution to time-dependent source functions.

42 ENGINEERING↗

Stability of electron energy in the Fermilab electron cooler

A powerful electron beam (4.3 MeV, 0.1 A DC) generated by an electrostatic accelerator has been used at Fermilab for three years to cool antiprotons in the Recycler ring. For electron cooling to be effective, the electron energy should not deviate from its optimum value by more than 500V. The main tool for studying the energy stability is the electron beam position in a high-dispersion area. The energy ripple (frequencies above 0.2 Hz) was found to be less than 150 eV rms; the main cause of the ripple is the fluctuations of the chain current. In addition, the energy can drift to up to several keV that is traced to two main sources. One of them is a drift of the charging current, and another is a temperature dependence of generating voltmeter readings. The paper describes the efforts to reach the required level of stability as well as the setup, diagnostics, results of measurements, and operational experience.

43 PARTICLE ACCELERATORS↗

Constraints on Λ(t)CDM models as holographic and agegraphic dark energy with the observational Hubble parameter data

The newly released observational H(z) data (OHD) is used to constrain Λ(t)CDM models as holographic and agegraphic dark energy. By the use of the length scale and time scale as the IR cut-off including Hubble horizon (HH), future event horizon (FEH), age of the universe (AU), and conformal time (CT), we achieve four different Λ(t)CDM models which can describe the present cosmological acceleration respectively. In order to get a comparison between such Λ(t)CDM models and standard ΛCDM model, we use the information criteria (IC), Om(z) diagnostic, and statefinder diagnostic to measure the deviations. Furthermore, by simulating a larger Hubble parameter data sample in the redshift range of 0.1 < z < 2.0, we get the improved constraints and more sufficient comparison. We show that OHD is not only able to play almost the same role in constraining cosmological parameters as SNe Ia does but also provides the effective measurement of the deviation of the DE models from standard ΛCDM model. In the holographic and agegraphic scenarios, the results indicate that the FEH is more preferable than HH scenario. However, both two time scenarios show better approximations to ΛCDM model than the length scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitive Ion Pump Current Monitoring Using an In-House Built Ion Pump Power Supply

Ion pumps are common vacuum pumps on DC high voltage photoguns and baked-accelerator beamlines. Commercial ion pump power supplies provide a measure of the electrical current drawn by the pump, but typically have resolution to only {approx}0.1 uA, which corresponds to pressure {approx}10{sup -9} Torr, a value considerably higher than the minimum pressure required by photoguns and nearby beamline. This submission describes a very sensitive in-house-built ion pump power supply with current monitoring capability good to less than 1 nA, and corresponding pressure in the low-minus;10{sup -11} Torr range. Besides providing 'free' pressure monitoring on a scale equivalent to the best available commercial pressure gauges, the ion pump power supply also serves as a sensitive diagnostic for detecting field emission from the photogun cathode electrode and bad electron beam orbits that could diminish photogun operating lifetime. Since its inception, this ion pump power supply has become an invaluable tool for operating the CEBAF polarized electron source. It is also a very useful low-cost diagnostic for ultrahigh vacuum studies in the laboratory.

43 PARTICLE ACCELERATORS↗

The SYRMEP Beamline of Elettra: Clinical Mammography and Bio-medical Applications

At the SYnchrotron Radiation for MEdical Physics (SYRMEP) beamline of Elettra Synchrotron Light Laboratory in Trieste (Italy), an extensive research program in bio-medical imaging has been developed since 1997. The core program carried out by the SYRMEP collaboration concerns the use of Synchrotron Radiation (SR) for clinical mammography with the aim of improving the diagnostic performance of the conventional technique. The first protocol with patients, started in 2006 has been completed at the end of 2009 and the data analysis is now in progress.Regarding applications different from clinical imaging, synchrotron X-ray computed microtomography (micro-CT) is the most used technique, both in absorption and phase contrast. A new software tool, Pore3D, has been developed to perform a quantitative morphological analysis on the reconstructed slices and to access textural information of the sample under study.

43 PARTICLE ACCELERATORS↗

A compact stilbene crystal neutron spectrometer for EAST D-D plasma neutron diagnostics

A new compact stilbene crystal neutron spectrometer has been investigated and applied in the neutron emission spectroscopy on the EAST tokamak. A new components analysis method is presented to study the anisotropic light output in the stilbene crystal detector. A Geant4 code was developed to simulate the neutron responses in the spectrometer. Based on both the optimal light output function and the fitted pulse height resolution function, a reliable neutron response matrix was obtained by Geant4 simulations and validated by 2.5 MeV and 14 MeV neutron measurements at a 4.5 MV Van de Graaff accelerator. The spectrometer was used to diagnose the ion temperature in plasma discharges with lower hybrid wave injection and ion cyclotron resonance heating on the EAST tokamak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and Suppression of the Electromagnetic Interference Induced Phase Shift in the JLab FEL Photo - Injector Advanced Drive Laser System

The drive laser for the photo-cathode gun used in the JLab Free Electron Laser (FEL) facility had been experiencing various phase shifts on the order of tens of degrees (>20{sup o} at 1497 MHz or >40ps) when changing the Advanced Drive Laser (ADL) [2][3][4] micro-pulse frequencies. These phase shifts introduced multiple complications when trying to setup the accelerator for operation, ultimately inhibiting the robustness and overall performance of the FEL. Through rigorous phase measurements and systematic characterizations, we determined that the phase shifts could be attributed to electromagnetic interference (EMI) coupling into the ADL phase control loop, and subsequently resolved the issue of phase shift to within tenths of a degree (<0.5{sup o} at 1497 MHz or <1ps). The diagnostic method developed and the knowledge gained through the entire process will prove to be invaluable for future designs of similar systems.

43 PARTICLE ACCELERATORS↗

Two-color monochromatic x-ray imaging with a single short-pulse laser

Here, simultaneous monochromatic crystal imaging at 4.5 and 8.0 keV with x-rays produced by a single short-pulse laser is presented. A layered target consisting of thin foils of titanium and copper glued together is irradiated by the 50 TW Leopard short-pulse laser housed at the Nevada Terawatt Facility. Laser-accelerated MeV fast electrons transmitting through the target induce Kα fluorescence from both foils. Two energy-selective curved crystals in the imaging diagnostic form separate monochromatic images on a single imaging detector. The experiment demonstrates simultaneous two-color monochromatic imaging of the foils on a single detector as well as Kα x-ray production at two different photon energies with a single laser beam. Lastly, application of the diagnostic technique to x-ray radiography of a high density plasma is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GEMS

The prime scientific objectives of the Gravity and Extreme Magnetism SMEX, GEMS, are to determine the effects of the spin of black holes, the configurations of the magnetic fields of magnetars, and the structure of the supernova shocks which accelerate cosmic rays. In the cases of both stellar black holes and supermassive black holes, sensitivity to 1% polarization is needed to make diagnostic measurements of the net polarizations predicted for probable disk and corona models. GEMS can reach this goal for several Seyferts and quasars and measure the polarizations of representatives of a variety of other classes of X-ray sources, such as rotation-powered and accretion-powered pulsars. GEMS uses foil mirrors to maximize the collecting area achievable within the SMEX constraints. The polarimeters at the mirror foci are Time Projection Chambers which use the photoelectic effect to measure the polarization of the incident photon. We have built laboratory models with good efficiency and modulation in the 2-10 keV range. An attached small student experiment would add 0.5 keV sensitivity for bright soft sources. The instrument has a point spread function which allows measurement of structures in the brighter nearby supernova remnants. GEMS' Orbital Sciences spacecraft will rotate at a rate of 0.1 revolutions per minute during observations, so that systematic errors due to the detector can be detected and corrected. A program of 35 sources can be observed in 9 months. GEMS is designed for a two year lifetime which will allow a General Observer program that would more than double the number of sources measured. For subsets of black holes, neutron stars and supernova remnants, GEMS will measure the polarization of several sources, solving important questions while establishing the sensitivity required for future missions.

Swank, Jean↗

High-current diode with ferroelectric plasma source-assisted hollow anode

The operation of a ferroelectric plasma source-assisted hollow anode (HA) electron source in a vacuum diode powered by an {approx}200 kV and {approx}400 ns pulsed generator was studied using time- and space-resolved laser induced fluorescence diagnostics. It was found that the plasma ion ''temperature'' in the vicinity of the HA output grid increases up to {approx}15 eV during the accelerating pulse, which is consistent with a model of the potential screening of the grid by the randomly moving ions [Phys. Plasmas 13, 073506 (2006)]. Also it was shown that the increase in the HA plasma potential up to several kilovolts because of the appearance of a noncompensated ion charge in the HA bulk plasma due to electrons fast extraction, leads to explosive emission centers being generated at the HA grid and to nonuniformity in the cross-sectional electron beam current density. Finally, the plasma prefilled mode of diode operation was studied using a simple one-dimensional model of the plasma erosion and the HA plasma electron heating by energetic ions was considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron Densities in Solar Flare Loops, Chromospheric Evaporation Upflows, and Acceleration Sites

We compare electron densities measured at three different locations in solar flares: (1) in Soft X-Ray (SXR) loops, determined from SXR emission measures and loop diameters from Yohkoh Soft X-Ray Telescope maps (n(sub e, sup SXR) = (0.2-2.5) x 10(exp 11)/ cu cm); (2) in chromospheric evaporation upflows, inferred from plasma frequency cutoffs of decimetric radio bursts detected with the 0.1-3 GHz spectrometer Phoenix of ETH Zuerich (n(sub e, sup upflow) = (0.3-11) x 10(exp 10)/cu cm; and (3) in acceleration sites, inferred from the plasma frequency at the separatrix between upward-accelerated (type III bursts) and downward-accelerated (reverse-drift bursts) electron beams [n(sub e, sup acc) = (0.6-10) x 10(exp 9)/cu cm]. The comparison of these density measurements, obtained from 44 flare episodes (during 14 different flares), demonstrates the compatibility of flare plasma density diagnostics with SXR and radio methods. The density in the upflowing plasma is found to be somewhat lower than in the filled loops, having ratios in a range n(sub e, sup upflow)/n(sub e, sup SXR) = 0.02-1.3, and a factor of 3.6 higher behind the upflow front. The acceleration sites are found to have a much lower density than the SXR-bright flare loops, i.e., n(sub e, sup acc)/n(sub e, sup SXR) = 0.005- 0.13, and thus must be physically displaced from the SXR-bright flare loops. The scaling law between electron time-of-flight distances l' and loop half-lengths s, l'/s = 1.4 +/- 0.3, recently established by Aschwanden et al. suggests that the centroid of the acceleration region is located above the SXR-bright flare loop, as envisioned in cusp geometries (e.g., in magnetic reconnection models).

Aschwanden, Markus J.↗

Simulation of Current Filamentation Instability for an Accelerator Beam in a Capillary Plasma

Current Filamentation Instability (CFI) is of central importance for the propagation of relativistic electron beams in plasmas. It could play an important role in the generation of magnetic fields and of radiation in the after-glow of gamma ray bursts as well as in hot electrons energy transport in the fast-igniter inertial confinement fusion concept. Using the particle-in-cell code QuickPIC, simulations of the electron beam at the Brookhaven National Laboratory--Accelerator Test Facility, BNL-ATF, propagating in a cm-long plasma were conducted. Simulation results show that with beam and plasma parameters achievable at the BNL-ATF, the CFI should be observed within 2 cm of plasma. Simulation results are presented for an experiment currently underway at BNL-ATF and possible diagnostics for characterizing the instability are discussed.

43 PARTICLE ACCELERATORS↗

Observation of electron cloud instabilities and emittance dilution at the Cornell electron-positron Storage ring Test Accelerator

Electron cloud related emittance dilution and instabilities of bunch trains limit the performance of high intensity circular colliders. One of the key goals of the Cornell electron-positron storage ring Test Accelerator (CesrTA) research program is to improve our understanding of how the electron cloud alters the dynamics of bunches within the train. Single bunch beam diagnostics have been developed to measure the beam spectra, vertical beam size, two important dynamical effects of beams interacting with the electron cloud, for bunch trains on a turn-by-turn basis. Experiments have been performed at CesrTA to probe the interaction of the electron cloud with stored positron bunch trains. The purpose of these experiments was to characterize the dependence of beam-electron cloud interactions on the machine parameters such as bunch spacing, vertical chromaticity, and bunch current. The beam dynamics of the stored beam, in the presence of the electron cloud, was quantified using: 1) a gated beam position monitor (BPM) and spectrum analyzer to measure the bunch-by-bunch frequency spectrum of the bunch trains, 2) an x-ray beam size monitor to record the bunch-by-bunch, turn-by-turn vertical size of each bunch within the trains. In this study we report on the observations from these experiments and analyze the effects of the electron cloud on the stability of bunches in a train under many different operational conditions.

43 PARTICLE ACCELERATORS↗

Essay: Bob Siemann-SLC Days at SLAC

Bob Siemann was a great experimentalist and an excellent teacher.We will greatly miss him. Bob came to SLAC in early 1991 to work on the Stanford Linear Collider (SLC). The SLC was a challenging accelerator which began operating in the late 1980's but still had numerous obstacles to be overcome years into operation. One of the compounding difficulties was making reproducible measurements, since the stability of the collider was poor and the diagnostics were insufficient. Bob dove into this challenge and helped design experiments and diagnostics that provided further clarity. I first got to know Bob while I was still a graduate student, trying to finish my thesis and performing some experimental studies on the SLC, which, at the time, was proving to be very difficult. Most of my expertise had been in beam theory and simulation. Dealing with the real issues of the accelerator was challenging. Bob helped me understand the difference between systematic and statistical errors, and separate operational issues from the fundamental physics. His way of teaching was not to provide an explanation but to ask enough questions so that I could find the answer on my own - this was the best way to learn. I later asked Bob to be a reader on my thesis. As in all things, he took this role extremely seriously. He read through the draft and marked every page to the point where I was regretting my decision. However, his questions again helped me understand my own work better and greatly improved my thesis. Bob was also the de facto leader of an effort focused on the damping rings and the bunch compressors. He was great to work with. He made people think for themselves and refused to simply provide answers. He also worked hard himself, expressing real interest and curiosity. After the studies of the SLC damping rings identified a sawtooth instability due to the vacuum chamber impedance as a source of many downstream fluctuations, Bob took charge of upgrading the rings. As part of this program, I suggested an extensive upgrade that also replaced the dipoles with combined function magnets which might have reduced the horizontal emittance another factor of 3. Although he was extremely busy, Bob helped me develop the proposal and understand the magnetic limitations as well as the potential impacts on the beam dynamics. He helped me consider issues well beyond my initial scope. While the proposal never went anywhere and I think Bob had been aware that there was no funding to pursue the option, he saw that it would be a great learning experience for me and it was. In the early 1990's I had simulated a new regime for the beam-ion instability and, with Frank Zimmermann, I developed a model for the effect which was predicted to occur within the high current, low emittance bunch trains in future storage rings or linear colliders. I thought this was pretty good work but Bob convinced me that the next step had to be confirming the theory with measurements. Because the growth rate was inversely dependent on beam sizes and proportional to the vacuum pressure, measurements required significantly increasing the vacuum pressure in existing facilities. Most people discounted trying such an experiment, but with Bob's urging and suggestions and John Byrd's excitement, we managed to make the measurements at the Advanced Light Source (ALS) at Berkeley. By the mid-1990's Bob was completely focused on advanced acceleration concepts and I was not interacting with him as often. At the time, SLAC was putting together a large effort in designing and documenting a design for the Next Linear Collider (NLC) while constructing the NLC Test Accelerator. Bob was worried that a straightforward extrapolation of the microwave technology would be difficult to bring to fruition because of the cost. He wanted to focus on more cost-effective approaches that could enable future accelerators for high energy physics. As usual, he was correct. The experimental programs that he started in direct laser acceleration and plasma-wakefield acceleration have made great progress. He accomplished this with lots of hard work and by engaging the people around him, especially students and postdocs. In the process, he created a group of extremely talented people which has enabled these technologies to be developed to the point where it seems likely that they are viable and will offer two cost-effective approaches to high-gradient acceleration.

43 PARTICLE ACCELERATORS↗

Repetitive production of positron emitters using deuterons accelerated by multiterawatt laser pulses

Positron emitters {sup 11}C, {sup 13}N, and {sup 15}O, which can be used in positron emission tomography, were produced using deuterons accelerated by irradiation of laser pulses {approx}70 TW in peak power and {approx}30 fs in duration with a repetition of 10 Hz during a period of as long as 200 s. Every laser pulse irradiates the fresh surface of a long strip of a solid-state thin film. Deuterons contained in the film are accelerated in the relativistic plasma induced by the pulse. The deuterons are repetitively incident on solid plates, which are placed near the film, to produce positron emitters by nuclear reactions. The radioactivities of the activated plates are measured after the termination of laser irradiation. In activation of graphite, boron-nitride, and melamine plates, the products had total activities of 64, 46, and 153 Bq, respectively. Contamination in the setup was negligible even after several thousands of laser shots. Our apparatus is expected to greatly contribute to the construction of a compact PET diagnostic system in the future.

43 PARTICLE ACCELERATORS↗

Experimental Investigation of Current Sheet Instabilities

Configuration space instabilities of propagating current sheets were studied in order to better understand acceleration mechanisms in pulsed plasma thrusters. Experiments were carried out in a parallel plate accelerator with argon as propellant. Propagating current sheets were visualized using fast framing cameras with inter-frame delays ranging between 0.05 - 2 microsecond. Schlieren photography using a pulse-burst Nd:YAG laser was used to image electron density gradients in the discharge. Magnetic field probes were used to map the magnetic field topology during the evolution of the discharge. Pressure probes were used to monitor axial pressure gradients. Emission spectroscopy was used to estimate the electron temperature in the arc. The motivation for applying all of these diagnostics was to gain an understanding of what parameters influence the macroscopic stability of a propagating current sheet. Since a stable current sheet is required for any effective snowplow-type of accelerator, an understanding of the processes which can cause current sheets to break apart into filaments is essential for the design of future pulsed plasma thrusters.

Markusic, Thomas E.↗