Search NASA⌕ Search

SEARCH · Search NASA

Results for “adaptive methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Fast BPM data distribution for global orbit feedback using commercial gigabit ethernet technology

In order to correct beam perturbations in RHIC around 10Hz, a new fast data distribution network was required to deliver BPM position data at rates several orders of magnitude above the capability of the existing system. The urgency of the project limited the amount of custom hardware that could be developed, which dictated the use of as much commercially available equipment as possible. The selected architecture uses a custom hardware interface to the existing RHIC BPM electronics together with commercially available Gigabit Ethernet switches to distribute position data to devices located around the collider ring. Using the minimum Ethernet packet size and a field programmable gate array (FPGA) based state machine logic instead of a software based driver, real-time and deterministic data delivery is possible using Ethernet. The method of adapting this protocol for low latency data delivery, bench testing of Ethernet hardware, and the logic to construct Ethernet packets using FPGA hardware will be discussed. A robust communications system using almost all commercial off-the-shelf equipment was developed in under a year which enabled retrofitting of the existing RHIC BPM system to provide 10 KHz data delivery for a global orbit feedback scheme using 72 BPMs. Total latencies from data acquisition at the BPMs to delivery at the controller modules, including very long transmission distances, were kept under 100 {micro}s, which provide very little phase error in correcting the 10 Hz oscillations. Leveraging off of the speed of Gigabit Ethernet and wide availability of Ethernet products enabled this solution to be fully implemented in a much shorter time and at lower cost than if a similar network was developed using a proprietary method.

43 PARTICLE ACCELERATORS↗

A Semi-Supervised Learning Method for the Identification of Bad Exposures in Large Imaging Surveys

As the data volume of astronomical imaging surveys rapidly increases, traditional methods for image anomaly detection, such as visual inspection by human experts, are becoming impractical. We introduce a machine-learning-based approach to detect poor-quality exposures in large imaging surveys, with a focus on the DECam Legacy Survey (DECaLS) in regions of low extinction (i.e., E ( B − V ) < 0.04 ). Our semi-supervised pipeline integrates a vision transformer (ViT), trained via self-supervised learning (SSL), with a k-Nearest Neighbor (kNN) classifier. We train and validate our pipeline using a small set of labeled exposures observed by surveys with the Dark Energy Camera (DECam). A clustering-space analysis of where our pipeline places images labeled in good and bad categories suggests that our approach can efficiently and accurately determine the quality of exposures. Applied to new imaging being reduced for DECaLS Data Release 11, our pipeline identifies 780 problematic exposures, which we subsequently verify through visual inspection. Being highly efficient and adaptable, our method offers a scalable solution for quality control in other large imaging surveys.

Luo, Yufeng (ORCID:0000000246230683)↗

Accurate multigrid solution of the Euler equations on unstructured and adaptive meshes

A method for accurately solving inviscid compressible flow in the subcritical and supercritical regimes about complex configurations is presented. The method is based on the use of unstructured triangular meshes in two dimensions, and special emphasis is placed on the accuracy and efficiency of the solutions. High accuracy is achieved by careful scaling of the artificial dissipation terms, and by reformulating the inner and outer boundary conditions for both the convective and dissipative operators. An adaptive grid refinement strategy is presented which enhances the solution accuracy for complex flows. When coupled with an unstructured multigrid algorithm, this method is shown to produce an efficient solver for flows about arbitrary configurations.

Mavriplis, Dimitri J.↗

Accurate multigrid solution of the Euler equations on unstructured and adaptive meshes

A method for accurately solving inviscid compressible flow in the subcritical and supercritical regimes about complex configurations is presented. The method is based on the use of unstructured triangular meshes in two dimensions, and special emphasis is placed on the accuracy and efficiency of the solutions. High accuracy is achieved by careful scaling of the artificial dissipation terms, and by reformulating the inner and outer boundary conditions for both the convective and dissipative operators. An adaptive grid refinement strategy is presented which enhances the solution accuracy for complex flows. When coupled with an unstructured multigrid algorithm, this method is shown to produce an efficient solver for flows about artibrary configurations.

Mavriplis, Dimitri J.↗

A general framework for quantifying uncertainty at scale

Abstract In many fields of science, comprehensive and realistic computational models are available nowadays. Often, the respective numerical calculations call for the use of powerful supercomputers, and therefore only a limited number of cases can be investigated explicitly. This prevents straightforward approaches to important tasks like uncertainty quantification and sensitivity analysis. This challenge can be overcome via our recently developed sensitivity-driven dimension-adaptive sparse grid interpolation strategy. The method exploits, via adaptivity, the structure of the underlying model (such as lower intrinsic dimensionality and anisotropic coupling of the uncertain inputs) to enable efficient and accurate uncertainty quantification and sensitivity analysis at scale. Here, we demonstrate the efficiency of this adaptive approach in the context of fusion research, in a realistic, computationally expensive scenario of turbulent transport in a magnetic confinement tokamak device with eight uncertain parameters, reducing the effort by at least two orders of magnitude. In addition, we show that this refinement method intrinsically provides an accurate surrogate model that is nine orders of magnitude cheaper than the high-fidelity model.

Farcaş, Ionuţ-Gabriel (ORCID:0000000238841580)↗

Conditional Karhunen–Loève regression model with Basis Adaptation for high-dimensional problems: Uncertainty quantification and inverse modeling

Here, we propose a methodology for improving the accuracy of surrogate models of the observable response of physical systems as a function of the systems’ spatially heterogeneous parameter fields, with applications to uncertainty quantification and parameter estimation in high-dimensional problems. Practitioners often formulate finite-dimensional representations of spatially heterogeneous parameter fields using truncated unconditional Karhunen–Loève expansions (KLEs) for a certain choice of unconditional covariance kernel and construct surrogate models of the observable response with respect to the KLE coefficients. When direct measurements of the parameter fields are available, we propose improving the accuracy of these surrogate models by representing the parameter fields via conditional Karhunen-Loève expansions (CKLEs). CKLEs are constructed by conditioning the covariance kernel of the unconditional expansion on the direct measurements of the parameter field via Gaussian process regression, and then truncating the corresponding KLE. We apply the proposed methodology to constructing surrogate models via the Basis Adaptation (BA) method of the stationary hydraulic head response, measured at spatially discrete observation locations, of a groundwater flow model of the Hanford Site, as a function of the 1000-dimensional representation of the model’s log-transmissivity field. We find that BA surrogate models of the hydraulic head based on CKLEs are more accurate than BA surrogate models based on unconditional expansions for forward uncertainty quantification tasks. Furthermore, we find that inverse estimates of the hydraulic transmissivity field computed using CKLE-based BA surrogate models are more accurate than those computed using unconditional BA surrogate models.

97 MATHEMATICS AND COMPUTING↗

TU-H-CAMPUS-JeP3-02: Automated Dose Accumulation and Dose Accuracy Assessment for Online Or Offline Adaptive Replanning

Purpose: With introduction of high-quality treatment imaging during radiation therapy (RT) delivery, e.g., MR-Linac, adaptive replanning of either online or offline becomes appealing. Dose accumulation of delivered fractions, a prerequisite for the adaptive replanning, can be cumbersome and inaccurate. The purpose of this work is to develop an automated process to accumulate daily doses and to assess the dose accumulation accuracy voxel-by-voxel for adaptive replanning. Methods: The process includes the following main steps: 1) reconstructing daily dose for each delivered fraction with a treatment planning system (Monaco, Elekta) based on the daily images using machine delivery log file and considering patient repositioning if applicable, 2) overlaying the daily dose to the planning image based on deformable image registering (DIR) (ADMIRE, Elekta), 3) assessing voxel dose deformation accuracy based on deformation field using predetermined criteria, and 4) outputting accumulated dose and dose-accuracy volume histograms and parameters. Daily CTs acquired using a CT-on-rails during routine CT-guided RT for sample patients with head and neck and prostate cancers were used to test the process. Results: Daily and accumulated doses (dose-volume histograms, etc) along with their accuracies (dose-accuracy volume histogram) can be robustly generated using the proposed process. The test data for a head and neck cancer case shows that the gross tumor volume decreased by 20% towards the end of treatment course, and the parotid gland mean dose increased by 10%. Such information would trigger adaptive replanning for the subsequent fractions. The voxel-based accuracy in the accumulated dose showed that errors in accumulated dose near rigid structures were small. Conclusion: A procedure as well as necessary tools to automatically accumulate daily dose and assess dose accumulation accuracy is developed and is useful for adaptive replanning. Partially supported by Elekta, Inc.

60 APPLIED LIFE SCIENCES↗

TH-A-BRF-08: Deformable Registration of MRI and CT Images for MRI-Guided Radiation Therapy

Purpose: To evaluate the quality of a commercially available MRI-CT image registration algorithm and then develop a method to improve the performance of this algorithm for MRI-guided prostate radiotherapy. Methods: Prostate contours were delineated on ten pairs of MRI and CT images using Eclipse. Each pair of MRI and CT images was registered with an intensity-based B-spline algorithm implemented in Velocity. A rectangular prism that contains the prostate volume was partitioned into a tetrahedral mesh which was aligned to the CT image. A finite element method (FEM) was developed on the mesh with the boundary constraints assigned from the Velocity generated displacement vector field (DVF). The resultant FEM displacements were used to adjust the Velocity DVF within the prism. Point correspondences between the CT and MR images identified within the prism could be used as additional boundary constraints to enforce the model deformation. The FEM deformation field is smooth in the interior of the prism, and equal to the Velocity displacements at the boundary of the prism. To evaluate the Velocity and FEM registration results, three criteria were used: prostate volume conservation and center consistence under contour mapping, and unbalanced energy of their deformation maps. Results: With the DVFs generated by the Velocity and FEM simulations, the prostate contours were warped from MRI to CT images. With the Velocity DVFs, the prostate volumes changed 10.2% on average, in contrast to 1.8% induced by the FEM DVFs. The average of the center deviations was 0.36 and 0.27 cm, and the unbalance energy was 2.65 and 0.38 mJ/cc3 for the Velocity and FEM registrations, respectively. Conclusion: The adaptive FEM method developed can be used to reduce the error of the MIbased registration algorithm implemented in Velocity in the prostate region, and consequently may help improve the quality of MRI-guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

MO-C-17A-11: A Segmentation and Point Matching Enhanced Deformable Image Registration Method for Dose Accumulation Between HDR CT Images

Purpose: To propose and validate a novel and accurate deformable image registration (DIR) scheme to facilitate dose accumulation among treatment fractions of high-dose-rate (HDR) gynecological brachytherapy. Method: We have developed a method to adapt DIR algorithms to gynecologic anatomies with HDR applicators by incorporating a segmentation step and a point-matching step into an existing DIR framework. In the segmentation step, random walks algorithm is used to accurately segment and remove the applicator region (AR) in the HDR CT image. A semi-automatic seed point generation approach is developed to obtain the incremented foreground and background point sets to feed the random walks algorithm. In the subsequent point-matching step, a feature-based thin-plate spline-robust point matching (TPS-RPM) algorithm is employed for AR surface point matching. With the resulting mapping, a DVF characteristic of the deformation between the two AR surfaces is generated by B-spline approximation, which serves as the initial DVF for the following Demons DIR between the two AR-free HDR CT images. Finally, the calculated DVF via Demons combined with the initial one serve as the final DVF to map doses between HDR fractions. Results: The segmentation and registration accuracy are quantitatively assessed by nine clinical HDR cases from three gynecological cancer patients. The quantitative results as well as the visual inspection of the DIR indicate that our proposed method can suppress the interference of the applicator with the DIR algorithm, and accurately register HDR CT images as well as deform and add interfractional HDR doses. Conclusions: We have developed a novel and robust DIR scheme that can perform registration between HDR gynecological CT images and yield accurate registration results. This new DIR scheme has potential for accurate interfractional HDR dose accumulation. This work is supported in part by the National Natural ScienceFoundation of China (no 30970866 and no 81301940)

60 APPLIED LIFE SCIENCES↗

Numerical Continuation Methods for Intrusive Uncertainty Quantification Studies

Rigorous modeling of engineering systems relies on efficient propagation of uncertainty from input parameters to model outputs. In recent years, there has been substantial development of probabilistic polynomial chaos (PC) Uncertainty Quantification (UQ) methods, enabling studies in expensive computational models. One approach, termed ”intrusive”, involving reformulation of the governing equations, has been found to have superior computational performance compared to non-intrusive sampling-based methods in relevant large-scale problems, particularly in the context of emerging architectures. However, the utility of intrusive methods has been severely limited due to detrimental numerical instabilities associated with strong nonlinear physics. Previous methods for stabilizing these constructions tend to add unacceptably high computational costs, particularly in problems with many uncertain parameters. In order to address these challenges, we propose to adapt and improve numerical continuation methods for the robust time integration of intrusive PC system dynamics. We propose adaptive methods, starting with a small uncertainty for which the model has stable behavior and gradually moving to larger uncertainty where the instabilities are rampant, in a manner that provides a suitable solution.

97 MATHEMATICS AND COMPUTING↗

Ammothermal Growth of Gan Substrates For Leds: High-Pressure Ammonothermal Process for Bulk Gallium Nitride Crystal Growth for Energy Efficient Commercially Competitive Lighting

Broad Funding Opportunity Announcement Project: The new GaN crystal growth method is adapted from that used to grow quartz crystals, which are very inexpensive and represent the second-largest market for single crystals for electronic applications (after silicon). More extreme conditions are required to grow GaN crystals and therefore a new type of chemical growth chamber was invented that is suitable for large-scale manufacturing. A new process was developed that grows GaN crystals at a rate that is more than double that of current processes. The new technology will enable GaN substrates with best-in-world quality at lowest-in-world prices, which in turn will enable new generations of white LEDs, lasers for full-color displays, and high-performance power electronics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Computerized analysis of coronary artery disease: Performance evaluation of segmentation and tracking of coronary arteries in CT angiograms

Purpose: The authors are developing a computer-aided detection system to assist radiologists in analysis of coronary artery disease in coronary CT angiograms (cCTA). This study evaluated the accuracy of the authors’ coronary artery segmentation and tracking method which are the essential steps to define the search space for the detection of atherosclerotic plaques. Methods: The heart region in cCTA is segmented and the vascular structures are enhanced using the authors’ multiscale coronary artery response (MSCAR) method that performed 3D multiscale filtering and analysis of the eigenvalues of Hessian matrices. Starting from seed points at the origins of the left and right coronary arteries, a 3D rolling balloon region growing (RBG) method that adapts to the local vessel size segmented and tracked each of the coronary arteries and identifies the branches along the tracked vessels. The branches are queued and subsequently tracked until the queue is exhausted. With Institutional Review Board approval, 62 cCTA were collected retrospectively from the authors’ patient files. Three experienced cardiothoracic radiologists manually tracked and marked center points of the coronary arteries as reference standard following the 17-segment model that includes clinically significant coronary arteries. Two radiologists visually examined the computer-segmented vessels and marked the mistakenly tracked veins and noisy structures as false positives (FPs). For the 62 cases, the radiologists marked a total of 10191 center points on 865 visible coronary artery segments. Results: The computer-segmented vessels overlapped with 83.6% (8520/10191) of the center points. Relative to the 865 radiologist-marked segments, the sensitivity reached 91.9% (795/865) if a true positive is defined as a computer-segmented vessel that overlapped with at least 10% of the reference center points marked on the segment. When the overlap threshold is increased to 50% and 100%, the sensitivities were 86.2% and 53.4%, respectively. For the 62 test cases, a total of 55 FPs were identified by radiologist in 23 of the cases. Conclusions: The authors’ MSCAR-RBG method achieved high sensitivity for coronary artery segmentation and tracking. Studies are underway to further improve the accuracy for the arterial segments affected by motion artifacts, severe calcified and noncalcified soft plaques, and to reduce the false tracking of the veins and other noisy structures. Methods are also being developed to detect coronary artery disease along the tracked vessels.

60 APPLIED LIFE SCIENCES↗

Adaptive Radiation Therapy for Postprostatectomy Patients Using Real-Time Electromagnetic Target Motion Tracking During External Beam Radiation Therapy

Purpose: Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Methods and Materials: Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (D{sub min}) with the planned D{sub min} to the CTV. Treatments were considered adequate if the delivered CTV D{sub min} is at least 95% of the planned CTV D{sub min}. Results: Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: −0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Conclusion: Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Organ sample generator for expected treatment dose construction and adaptive inverse planning optimization

Purpose: To create an organ sample generator (OSG) for expected treatment dose construction and adaptive inverse planning optimization. The OSG generates random samples of organs of interest from a distribution obeying the patient specific organ variation probability density function (PDF) during the course of adaptive radiotherapy. Methods: Principle component analysis (PCA) and a time-varying least-squares regression (LSR) method were used on patient specific geometric variations of organs of interest manifested on multiple daily volumetric images obtained during the treatment course. The construction of the OSG includes the determination of eigenvectors of the organ variation using PCA, and the determination of the corresponding coefficients using time-varying LSR. The coefficients can be either random variables or random functions of the elapsed treatment days depending on the characteristics of organ variation as a stationary or a nonstationary random process. The LSR method with time-varying weighting parameters was applied to the precollected daily volumetric images to determine the function form of the coefficients. Eleven h and n cancer patients with 30 daily cone beam CT images each were included in the evaluation of the OSG. The evaluation was performed using a total of 18 organs of interest, including 15 organs at risk and 3 targets. Results: Geometric variations of organs of interest during h and n cancer radiotherapy can be represented using the first 3 {approx} 4 eigenvectors. These eigenvectors were variable during treatment, and need to be updated using new daily images obtained during the treatment course. The OSG generates random samples of organs of interest from the estimated organ variation PDF of the individual. The accuracy of the estimated PDF can be improved recursively using extra daily image feedback during the treatment course. The average deviations in the estimation of the mean and standard deviation of the organ variation PDF for h and n cancer radiotherapy were less than 2 and 1 mm, respectively, for most organs after the second week of treatment. After the first three weeks of treatment, the mean discrepancy of the dose estimation accuracy was within 1% for most of organs, the corresponding standard deviation was within 2.5% for parotids, the brain stem and the cochleae, and within 1% for other organs. Conclusions: A patient specific OSG is feasible and can be used to generate random samples of organs of interest for the expected treatment dose construction and adaptive inverse planning. The accuracy of the OSG can be improved continuously and recursively during the adaptive treatment course using daily volumetric image feedback.

60 APPLIED LIFE SCIENCES↗

TH-A-BRF-02: BEST IN PHYSICS (JOINT IMAGING-THERAPY) - Modeling Tumor Evolution for Adaptive Radiation Therapy

Purpose: To develop mathematical models of tumor geometry changes under radiotherapy that may support future adaptive paradigms. Methods: A total of 29 cervical patients were scanned using MRI, once for planning and weekly thereafter for treatment monitoring. Using the tumor volumes contoured by a radiologist, three mathematical models were investigated based on the assumption of a stochastic process of tumor evolution. The “weekly MRI” model predicts tumor geometry for the following week from the last two consecutive MRI scans, based on the voxel transition probability. The other two models use only the first pair of consecutive MRI scans, and the transition probabilities were estimated via tumor type classified from the entire data set. The classification is based on either measuring the tumor volume (the “weekly volume” model), or implementing an auxiliary “Markov chain” model. These models were compared to a constant volume approach that represents the current clinical practice, using various model parameters; e.g., the threshold probability β converts the probability map into a tumor shape (larger threshold implies smaller tumor). Model performance was measured using volume conformity index (VCI), i.e., the union of the actual target and modeled target volume squared divided by product of these two volumes. Results: The “weekly MRI” model outperforms the constant volume model by 26% on average, and by 103% for the worst 10% of cases in terms of VCI under a wide range of β. The “weekly volume” and “Markov chain” models outperform the constant volume model by 20% and 16% on average, respectively. They also perform better than the “weekly MRI” model when β is large. Conclusion: It has been demonstrated that mathematical models can be developed to predict tumor geometry changes for cervical cancer undergoing radiotherapy. The models can potentially support adaptive radiotherapy paradigm by reducing normal tissue dose. This research was supported in part by the Ontario Consortium for Adaptive Interventions in Radiation Oncology (OCAIRO) funded by the Ontario Research Fund (ORF) and the MITACS Accelerate Internship Program.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-58: Evaluation of RayStation Hybrid Deformable Image Registration for Accurate Contour Propagation in Adaptive Planning

Purpose: Adaptive radiotherapy requires complete new sets of regions of interests (ROIs) delineation on the mid-treatment CT images. This work aims at evaluating the accuracy of the RayStation hybrid deformable image registration (DIR) algorithm for its overall integrity and accuracy in contour propagation for adaptive planning. Methods: The hybrid DIR is based on the combination of intensity-based algorithm and anatomical information provided by contours. Patients who received mid-treatment CT scans were identified for the study, including six lung patients (two mid-treatment CTs) and six head-and-neck (HN) patients (one mid-treatment CT). DIRpropagated ROIs were compared with physician-drawn ROIs for 8 ITVs and 7 critical organs (lungs, heart, esophagus, and etc.) for the lung patients, as well as 14 GTVs and 20 critical organs (mandible, eyes, parotids, and etc.) for the HN patients. Volume difference, center of mass (COM) difference, and Dice index were used for evaluation. Clinical-relevance of each propagated ROI was scored by two physicians, and correlated with the Dice index. Results: For critical organs, good agreement (Dice>0.9) were seen on all 7 for lung patients and 13 out of 20 for HN patients, with the rest requiring minimal edits. For targets, COM differences were within 5 mm on average for all patients. For Lung, 5 out of 8 ITVs required minimal edits (Dice 0.8–0.9), with the rest 2 needed re-drawn due to their small volumes (<10 cc). However, the propagated HN GTVs resulted in relatively low Dice values (0.5–0.8) due to their small volumes (3–40 cc) and high variability, among which 2 required re-drawn due to new nodal target identified on the mid-treatment CT scans. Conclusion: The hybrid DIR algorithm was found to be clinically useful and efficient for lung and HN patients, especially for propagated critical organ ROIs. It has potential to significantly improve the workflow in adaptive planning.

60 APPLIED LIFE SCIENCES↗

Assessment of Parametrial Response by Growth Pattern in Patients With International Federation of Gynecology and Obstetrics Stage IIB and IIIB Cervical Cancer: Analysis of Patients From a Prospective, Multicenter Trial (EMBRACE)

Purpose: To assess disease response along the parametrial space according to tumor morphology in patients with International Federation of Gynecology and Obstetrics (FIGO) stage IIB and IIIB cervical cancer at the time of image-guided adaptive brachytherapy. Methods and Materials: Patients with FIGO stage IIB and IIIB cervical cancer registered as of November 2013 in the EMBRACE study were evaluated. Tumors were stratified according to morphologic subtype on magnetic resonance imaging (expansive and infiltrative), and the characteristics of those subtypes were analyzed. Parametrial involvement at diagnosis and at brachytherapy was evaluated, and the response to chemo-radiotherapy was classified as good, moderate, or poor. The response grade was compared between the 2 groups and analyzed with regard to tumor volumes, and dosimetric parameters. Results: A total of 452 patients were evaluated, of whom 186 had expansive growth type and 266 had infiltrative morphology. Patients with infiltrative tumors had more extensive disease, as indicated by a higher rate of FIGO stage IIIB disease, as well as radiologic evidence of extension into the distal parametrial space and to the pelvic side wall on magnetic resonance imaging. Cervical necrosis was more common in the infiltrative group. Good response was more common in the expansive group (34% vs 24%; P=.02), and poor response was more common in the infiltrative group (11% and 19%; P=.02). Mean gross tumor volume at diagnosis was equal in both groups (51.7 cm{sup 3}). The high-risk clinical target volume was larger in infiltrative tumors (37.9 cm{sup 3} vs 33.3 cm{sup 3}, P=.005). The mean high-risk clinical target volume D{sub 90} was slightly higher in expansive tumors (92.7 Gy and 89.4 Gy, P<.001). Conclusion: Infiltrative tumors are more advanced at presentation and respond less favorably to chemo-radiotherapy when compared with expansive tumors that are more or less equivalent in size. The use of image-guided adaptive brachytherapy allows achieving reasonably high doses in both groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DGDFT: A massively parallel method for large scale density functional theory calculations

We describe a massively parallel implementation of the recently developed discontinuous Galerkin density functional theory (DGDFT) method, for efficient large-scale Kohn-Sham DFT based electronic structure calculations. The DGDFT method uses adaptive local basis (ALB) functions generated on-the-fly during the self-consistent field iteration to represent the solution to the Kohn-Sham equations. The use of the ALB set provides a systematic way to improve the accuracy of the approximation. By using the pole expansion and selected inversion technique to compute electron density, energy, and atomic forces, we can make the computational complexity of DGDFT scale at most quadratically with respect to the number of electrons for both insulating and metallic systems. We show that for the two-dimensional (2D) phosphorene systems studied here, using 37 basis functions per atom allows us to reach an accuracy level of 1.3 × 10{sup −4} Hartree/atom in terms of the error of energy and 6.2 × 10{sup −4} Hartree/bohr in terms of the error of atomic force, respectively. DGDFT can achieve 80% parallel efficiency on 128,000 high performance computing cores when it is used to study the electronic structure of 2D phosphorene systems with 3500-14 000 atoms. This high parallel efficiency results from a two-level parallelization scheme that we will describe in detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗