Search NASA⌕ Search

SEARCH · Search NASA

Results for “algorithmic development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

TU-EF-BRD-04: Summing It Up: The Future of Quality and Safety Research

Research related to quality and safety has been a staple of medical physics academic activities for a long time. From very early on, medical physicists have developed new radiation measurement equipment and analysis techniques, created ever increasingly accurate dose calculation models, and have vastly improved imaging, planning, and delivery techniques. These and other areas of interest have improved the quality and safety of radiotherapy for our patients. With the advent of TG-100, quality and safety is an area that will garner even more research interest in the future. As medical physicists pursue quality and safety research in greater numbers, it is worthwhile to consider what actually constitutes research on quality and safety. For example, should the development of algorithms for real-time EPID-based in-vivo dosimetry be defined as “quality and safety” research? How about the clinical implementation of such as system? Surely the application of failure modes and effects analysis to a clinical process would be considered quality and safety research, but is this type of research that should be included in the medical physics peer-reviewed literature? The answers to such questions are of critical importance to set researchers in a direction that will provide the greatest benefit to our field and the patients we serve. The purpose of this symposium is to consider what constitutes research in the arena of quality and safety and differentiate it from other research directions. The key distinction here is developing the tool itself (e.g. algorithms for EPID dosimetry) vs. studying the impact of the tool with some quantitative metric. Only the latter would I call quality and safety research. Issues of ‘basic’ versus ‘applied’ quality and safety research will be covered as well as how the research results should be structured to provide increasing levels of support that a quality and safety intervention is effective and sustainable. Examples from existing peer-reviewed research will be used to highlight the main points. Historical, medical physicists have leveraged many areas of applied physics, engineering and biology to improve radiotherapy. Research on quality and safety is another area where physicists can have an impact. The key to further progress is to clearly define what constitutes quality and safety research for those interested in doing such research and the reviewers of that research. Learning Objectives: List several tools of quality and safety with references to peer-reviewed literature. Describe effects of mental workload on performance. Outline research in quality and safety indicators and technique analysis. Understand what quality and safety research needs to be going forward. Understand the links between cooperative group trials and quality and safety research.

60 APPLIED LIFE SCIENCES↗

A DVH-guided IMRT optimization algorithm for automatic treatment planning and adaptive radiotherapy replanning

Purpose: To develop a novel algorithm that incorporates prior treatment knowledge into intensity modulated radiation therapy optimization to facilitate automatic treatment planning and adaptive radiotherapy (ART) replanning. Methods: The algorithm automatically creates a treatment plan guided by the DVH curves of a reference plan that contains information on the clinician-approved dose-volume trade-offs among different targets/organs and among different portions of a DVH curve for an organ. In ART, the reference plan is the initial plan for the same patient, while for automatic treatment planning the reference plan is selected from a library of clinically approved and delivered plans of previously treated patients with similar medical conditions and geometry. The proposed algorithm employs a voxel-based optimization model and navigates the large voxel-based Pareto surface. The voxel weights are iteratively adjusted to approach a plan that is similar to the reference plan in terms of the DVHs. If the reference plan is feasible but not Pareto optimal, the algorithm generates a Pareto optimal plan with the DVHs better than the reference ones. If the reference plan is too restricting for the new geometry, the algorithm generates a Pareto plan with DVHs close to the reference ones. In both cases, the new plans have similar DVH trade-offs as the reference plans. Results: The algorithm was tested using three patient cases and found to be able to automatically adjust the voxel-weighting factors in order to generate a Pareto plan with similar DVH trade-offs as the reference plan. The algorithm has also been implemented on a GPU for high efficiency. Conclusions: A novel prior-knowledge-based optimization algorithm has been developed that automatically adjust the voxel weights and generate a clinical optimal plan at high efficiency. It is found that the new algorithm can significantly improve the plan quality and planning efficiency in ART replanning and automatic treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DNDO Report: Developing a Photon Clutter Scaling Algorithm for Implementation into the NINESIM Tool

The Nuclear Inspection Node Event SIMulator (NINESIM) is a tool that is capable of modeling a node that monitors passing traffic for radiological and nuclear materials. This task requires the consideration of a number of factors. One such factor is clutter, or the level of traffic passing through a node. Clutter might affect the performance of radiation detectors due to attenuation or scattering that particles undergo as they move through the material. This paper discusses the results from MCNP simulations that were performed to determine in what scenarios clutter had a significant impact on detector performance, where the receiver operating characteristic (ROC) curve was used as the metric to evaluate detector performance. Clutter was found to have an insignificant impact on neutron detection, therefore, clutter may be ignored when modeling neutron detectors. However, there were a number of scenarios where clutter was found to affect the performance of photon detectors; the amount of traffic was found to be directly proportional to the effectiveness of photon detectors. The results of this work were then used to develop a photon clutter scaling algorithm that will be implemented into NINESIM. The Domestic Nuclear Detection Office, and possibly other agencies such as the Defense Threat Reduction Agency, will benefit from this work by eventually obtaining a tool that can enhance their ability in countering the illicit movement of radiological and nuclear materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Searching for Clues for a Matter Dominated Universe in Liquid Argon Time Projection Chambers

Liquid Argon Time Projection Chambers (LArTPCs) represent one of the most widely utilized neutrino detection techniques in neutrino experiments, for instance, in the Short Baseline Neutrino (SBN) program and the future large-scale LArTPC: Deep Underground Neutrino Experiment (DUNE). The high-end technique, facilitating excellent spatial and calorimetric reconstruction resolution, also enables testing exotic Beyond Standard Model (BSM) theories, such as baryon number violation (BNV) processes (e.g., proton-decay, neutron-antineutron oscillation). At the same time, Machine Learning (ML) techniques have demonstrated their ubiquitous use in recent decades; ML techniques have also become some of the most powerful tools in high-energy physics (HEP) analyses. Furthermore, the development of algorithms to cater to the needs of problems in HEP (i.e., triggering, reconstruction, improving sensitivity, etc.) has also become an active area of research. By developing a combined approach using Convolutional Neural Network (CNN) and Boosted Decision Tree (BDT) techniques, the sensitivity of neutron-antineutron oscillation in DUNE is evaluated for a projected exposure of 400kton·years. Additionally, to meet the triggering requirement to select such rare events in DUNE, such a search is only supported with highly efficient self-triggering algorithms. An ML-based self-triggering scheme for large-scale LArTPCs, such as DUNE, is also developed with the intention of implementation on field-programmable gate arrays (FPGAs). The ML-based approach for searching for neutron-antineutron oscillation can be demonstrated and validated on the current LArTPC MicroBooNE. The analysis in MicroBooNE represents the first-ever search for neutron-antineutron oscillation in a LArTPC. DUNE's projected 90% C.L. sensitivity to the neutron antineutron oscillation lifetime is 6.45×10³² years, assuming 1.327×10³⁵ neutron·years, equivalent to 10 years of DUNE far detector exposure (400kton·years). For MicroBooNE, assuming 372 seconds of exposure (equivalent to 3.13×10³⁶ neutron·years), the 90% C.L. lifetime sensitivity is found at 3.07×10²⁵ yrs, after accounting for Monte-Carlo statistical uncertainty and systematic uncertainty from detector effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

A multiscale flux basis for mortar mixed discretizations of Stokes–Darcy flows

A multiscale flux basis algorithm is developed for the Stokes–Darcy flow problem. The method is based on a non-overlapping domain decomposition algorithm, where the global problem is reduced to a coarse scale mortar interface problem that is solved by an iterative solver. Subdomain solves are required at each interface iteration, so the cost for the method without a multiscale basis can be high when the number of subdomains or the condition number of the interface problem is large. Here the proposed algorithm involves precomputing a multiscale flux basis, which consists of the flux (or velocity trace) response from each mortar degree of freedom. It is computed by each subdomain independently before the interface iteration begins. The subdomain solves required at each iteration are substituted by a linear combination of the multiscale basis. This may lead to a significant reduction in computational cost since the number of subdomain solves is fixed, depending only on the number of mortar degrees of freedom associated with a subdomain. Several numerical examples are carried out to demonstrate the efficiency of the multiscale flux basis implementation for large-scale Stokes–Darcy problems.

97 MATHEMATICS AND COMPUTING↗

A performance evaluation framework for building fault detection and diagnosis algorithms

Fault detection and diagnosis (FDD) algorithms for building systems and equipment represent one of the most active areas of research and commercial product development in the buildings industry. However, far more effort has gone into developing these algorithms than into assessing their performance. As a result, considerable uncertainties remain regarding the accuracy and effectiveness of both research-grade FDD algorithms and commercial products - a state of affairs that has hindered the broad adoption of FDD tools. This article presents a general, systematic framework for evaluating the performance of FDD algorithms. The article focuses on understanding the possible answers to two key questions: in the context of FDD algorithm evaluation, what defines a fault and what defines an evaluation input sample? The answers to these questions, together with appropriate performance metrics, may be used to fully specify evaluation procedures for FDD algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Representing Small Commercial Building Faults in EnergyPlus, Part II: Model Validation

Automated fault detection and diagnosis (AFDD) tools based on machine-learning algorithms hold promise for lowering cost barriers for AFDD in small commercial buildings; however, access to high-quality training data for such algorithms is often difficult to obtain. To fill the gap in this research area, this study covers the development (Part I) and validation (Part II) of fault models that can be used with the building energy modeling software EnergyPlus® and OpenStudio® to generate a cost-effective training data set for developing AFDD algorithms. Part II (this paper) first presents a methodology of validating fault models with OpenStudio and then presents validation results, which are compared against measurements from a reference building. We discuss the results of our experiments with eight different faults in the reference building (a total of 39 different baseline and faulted scenarios), including our methodology for using fault models along with the reference building model to simulate the same faulted scenarios. Then, we present validation of the fault models by comparing results of simulations and experiments either quantitatively or qualitatively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Porting Classical Approaches for Quantum Simulations to Quantum Computers

Simulating quantum many-body systems is one of the most promising problems in which we might anticipate that quantum computers should show quantum advantage. Unfortunately, there is still a gap between this promise and actual practice. New quantum algorithms need to be developed and the current quantum algorithms have various difficulties - e.g efficient state preparation - which must be overcome and improved upon. In many cases, classical approaches need to be ported over to quantum devices. In this project we have developed a suite of new quantum algorithms which makes progress in this regard. We developed a new optimization scheme for variational quantum eigensolvers, UBOS, which mitigates problems with local minimas and barren plateaus while improving convergence to the ground state by an order of magnitude. We developed a new way to utilize qubitization to find ground states of nearly frustration-free Hamiltonians faster than all previous methods. We developed a series of state preparation techniques which helps initialize parameterized quantum circuits into reasonable starting points on which quantum algorithms are then applied. In addition to the development of novel algorithms, it is critical to have classical simulation techniques for approximately simulating quantum circuits which can be used to benchmark and understand quantum algorithms. Toward that end, we developed a novel POVM formalism to simulate quantum circuits as well as exemplify the massive parallelization of tensor network methodologies. Finally, we developed physical understanding of entanglement phase transitions such as many-body localization and random tensor networks.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Repair and Resource Scheduling in Unbalanced Distribution Systems Using Neighborhood Search

—This paper proposes an optimization strategy to assist utility operators to recover power distribution systems after large outages. Specifically, a mixed-integer linear programming (MILP) model is developed for co-optimizing crews, resources, and network operations. The MILP model coordinates damage isolation, network reconfiguration, distributed generator re-dispatch, and crew/resource logistics. In addition, a framework for integrating different types of photovoltaic (PV) systems in the restoration process is developed. We consider two different types of crews, namely, line crews for damage repair and tree crews for obstacle removal. We also model the repair resource logistic constraints. Furthermore, a new algorithm is developed for solving the distribution system repair and restoration problem (DSRRP). The algorithm starts by solving DSRRP using an assignmentbased method, then a neighborhood search method is designed to iteratively improve the solution. The proposed method is validated on modified IEEE 123- and 8500-bus distribution test systems.

Outage management↗

TH-A-19A-01: An Open Source Software for Proton Treatment Planning in Heterogeneous Medium

Purpose: Due to its success in Radiation Oncology during the last decade, interest in proton therapy is on the rise. Unfortunately, despite the global enthusiasm in the field, there is presently no free, multiplatform and customizable Treatment Planning System (TPS) providing proton dose distributions in heterogenous medium. This restricts substantially the progress of clinical research for groups without access to a commercial Proton TPS. The latest implementation of our pencil beam dose calculation algorithm for proton beams within the 3D Slicer open-source environment fulfills all the conditions described above. Methods: The core dose calculation algorithm is based on the Hong algorithm (1), which was upgraded with the Kanematsu theory describing the evolution of the lateral scattering of proton beamlets in heterogeneous medium. This algorithm deals with both mono-energetic beams and Spread Out Bragg Peak (SOBP). In order to be user-friendly, we provide a graphical user interface implemented with the Qt libraries, and visualization with the 3D Slicer medical image analysis software. Two different pencil beam algorithms were developed, and the clinical proton beam line at our facility was modeled. Results: The dose distributions provided by our algorithms were compared to dose distributions coming from both commercialized XiO TPS and literature (dose measurements, GEANT4 and MCNPx) and turned out to be in a good agreement, with maximum dose discrepancies of 5% in homogeneous phantoms and 10% in heterogeneous phantoms. The algorithm of SOBP creation from an optimized weigthing of mono-energetic beams results in flat SOBP. Conclusion: We hope that our efforts in implementing this new, open-source proton TPS will help the research groups to have a free access to a useful, reliable proton dose calculation software.(1) L. Hong et al., A pencil beam algorithm for proton dose calculations, Phys. Med. Biol. 41 (1996) 1305–1330. This project is paid for by NCI/MGH Federal share as a research grant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of local capillary trapping on containment system effectiveness

Immobilization of CO 2 injected into deep subsurface storage reservoirs is a critical component of risk assessment for geologic CO 2 storage (GCS). Local capillary trapping (LCT) is a recently established mode of immobilization that arises when CO 2 migrates due to buoyancy through heterogeneous storage reservoirs. This project sought to assess the amount and extent of LCT expected in storage formations under a range of injection conditions, and to confirm the persistence of LCT if the seal overlying the reservoir were to lose its integrity. Numerical simulation using commercial reservoir simulation software was conducted to assess the influence of injection. Laboratory experiments, modeling and numerical simulation were conducted to assess the effect of compromised seal integrity. Bench-scale (0.6 m by 0.6 m by 0.03 m) experiments with surrogate fluids provided the first empirical confirmation of the key concepts underlying LCT: accumulation of buoyant nonwetting phase at above residual saturations beneath capillary barriers in a variety of structures, which remains immobile under normal capillary pressure gradients. Immobilization of above-residual saturations is a critical distinction between LCT and the more familiar “residual saturation trapping.” To estimate the possible extent of LCT in a storage reservoir an algorithm was developed to identify all potential local traps, given the spatial distribution of capillary entry pressure in the reservoir. The algorithm assumes that the driving force for CO 2 migration can be represented as a single value of “critical capillary entry pressure” P c,entry crit , such that cells with capillary entry pressure greater/less than P c,entry crit act as barriers/potential traps during CO 2 migration. At intermediate values of P c,entry crit , the barrier regions become more laterally extensive in the reservoir, approaching a percolation threshold while non-barrier regions remain numerous. The maximum possible extent of LCT thus occurs at P c,entry crit near this threshold. Testing predictions of this simple algorithm against full-physics simulations of buoyancy-driven CO 2 migration support the concept of critical capillary entry pressure. However, further research is needed to determine whether a single value of critical capillary entry pressure always applies and how that value can be determined a priori. Simulations of injection into high-resolution (cells 0.3 m on a side) 2D and 3D heterogeneous domains show two characteristic behaviors. At small gravity numbers (vertical flow velocity much less than horizontal flow velocity) the CO 2 fills local traps as well as regions that would act as local barriers if CO 2 were moving only due to buoyancy. When injection ceases, the CO 2 migrates vertically to establish large saturations within local traps and residual saturation elsewhere. At large gravity numbers, the CO 2 invades a smaller portion of the perforated interval. Within this smaller swept zone the local barriers are not invaded, but local traps are filled to large saturation during injection and remain during post-injection gravity-driven migration. The small gravity number behavior is expected in the region within 100 m of a vertical injection well at anticipated rates of injection for commercial GCS. Simulations of leakage scenarios (through-going region of large permeability imposed in overlying seal) indicate that LCT persists (i.e. CO 2 remains held in a large fraction of the local iv traps) and the persistence is independent of injection rate during storage. Simulations of leakage for the limiting case of CO 2 migrating vertically from an areally extensive emplacement in the lower portion of a reservoir showed similar strong persistence of LCT. This research has two broad implications for GCS. The first is that LCT can retain a significant fraction of the CO 2 stored in a reservoir – above and beyond the residual saturation -- if the overlying seal were to fail. Thus frameworks for risk assessment should be extended to account for LCT. The second implication is that compared to pressure driven flow in reservoirs, CO 2 migration and trapping behave in a qualitatively different manner in heterogeneous reservoirs when buoyancy is the dominant driving force for flow. Thus simulations of GCS that neglect capillary heterogeneity will fail to capture important features of the CO 2 plume. While commercial reservoir simulation software can account for fine scale capillary heterogeneity, it has not been designed to work efficiently with such domains, and no simulators can handle fine-scale resolution throughout the reservoir. A possible way to upscale the migration and trapping is to apply an “effective residual saturation” to coarse-scale grids. While the extent of overall immobilization can be correlated in this way, all coarser grids failed to capture the distance traveled by the migrating CO 2 for large gravity number. Thus it remains unclear how best to account for LCT in the routine simulation work-flow that will be needed for large-scale GCS. Alternatives meriting investigation include streamline methods, reduced-physics proxies (e.g. particle tracking), and biased invasion percolation algorithms, which are based on precisely the capillary heterogeneity essential for LCT.

58 GEOSCIENCES↗

Controllable 3D Manufacturing System

Next generation Small Modular Reactor (SMR) requires new and improved techniques, instrumentations and strategies to deal with the anticipated high radiation and high temperature environment (esp. in reactors). Component manufacturing technologies will be required that take full advantage of the new 3-D printing methods employed by additive manufacturing technologies. These manufacturing methods must be capable of producing components or sub components on a limited production basis and with nuclear quality. Based on our success in developing a variety of award-winning high energy and high power ultrafast fiber lasers and our pioneered work in fs laser 3D manufacturing (US patents, 9643361 and 9770760), PolarOnyx proposes to use tunable fiber lasers to develop smart AM & SM system to make nuclear quality components for SMR. In Phase I, we have achieved critical milestones and experimentally demonstrated the most critical functions of the proposed controllable laser AM: • Developed and investigated a series of NDI sensing technologies. Combination of IR thermal image and high resolution visible camera provides a powerful tool to characterize thermal distribution and defects. • Built an in-line laser induced breakdown spectroscopy (LIBS) to real time detect compositions of powder and parts, and melting temperature of the melting pool. It proves the LIBS is a very powerful tool to precisely guide the process. • Filed a patent (Application number 16378485) for integrating IR and visible images and LIBS for intelligent AM system. • Developed control algorithm and proved it works well for overhang experiment. • Achieved high density (>99%) and excellent mechanical properties. • Succeeded in developing a working and reliable calibration method to extract true temperature distribution during AM process. • Demonstrated spatial and temporal pulse shaping methods, and impact on microstructures. • Filed one utility patent • Laid out a solid path for phase II to work on controllable 3D manufacturing system development and optimization and to make components with nuclear quality. Our proprietary fs fiber laser based AM processing offers an ultimate solution for manufacturing high temperature components with high strength for nuclear systems. The 3D AM system in conjunction with the intelligent sensing and control is energy efficient and cost effective for the growing nuclear industries. Successful development of the proposed AM technology will provide a vital tool to solve existing and potential issues. This technology will be directly applied in the 3D printing area with combined market share of $10(s) of billions. The achievement in this research will have significant and wide social, scientific, and economic impacts by providing affordable low cost intelligent AM/SM systems, laser micromachining systems, improving energy efficiency, and reducing fabrication and operational cost. Having demonstrated the proof of concept in Phase I, we will prototype the controllable AM/SM system and investigate the efficiency and qualification of fabricating various nuclear quality components in Phase II.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a rhesus monkey lung geometry model and application to particle deposition in comparison to humans

The exposure-dose-response characterization of an inhalation hazard established in an animal species needs to be translated to an equivalent characterization in humans relative to comparable doses or exposure scenarios. Here, the first geometry model of the conducting airways for rhesus monkeys is developed based upon CT images of the conducting airways of a 6-month-old male, rhesus monkey. An algorithm was developed for adding the alveolar region airways using published rhesus morphometric data. The resultant lung geometry model can be used in mechanistic particle or gaseous dosimetry models. Such dosimetry models require estimates of the upper respiratory tract volume of the animal and the functional residual capacity, as well as of the tidal volume and breathing frequency of the animal. The relationship of these variables to rhesus monkeys of differing body weights was established by synthesizing and modeling published data as well as modeling pulmonary function measurements on 121 rhesus control animals. Deposition patterns of particles up to 10 µm in size were examined for endotracheal and and up to 5 µm for spontaneous breathing in infant and young adult monkeys and compared to those for humans. Deposition fraction of respirable size particles was found to be higher in the conducting airways of infant and young adult rhesus monkeys compared to humans. Due to the filtering effect of the conducting airways, pulmonary deposition in rhesus monkeys was lower than that in humans. Finally, future research areas are identified that would either allow replacing assumptions or improving the newly developed lung model.

Asgharian, Bahman↗

MRCK_3D contact detonation algorithm

Large-scale Combined Finite-Discrete Element Methods (FEM-DEM) and Discrete Element Methods (DEM) simulations involving contact of a large number of separate bod ies need an efficient, robust and flexible contact detection algorithm. In this work the MRCK-3D search algorithm is outlined and its main CPU perfonnances are evaluated. One of the most important aspects of this newly developed search algorithm is that it is applicable to systems consisting of many bodies of different shapes and sizes.

58 GEOSCIENCES↗

Novel Relativistic Electronic Structure Theories for Actinide-Containing Compounds

Actinides of importance to basic energy sciences contain electrons moving at speed comparable to the speed of light. Reliable computational simulation of these electrons and hence actinide chemistry requires accurate description of relativistic effects. The present project advances computational actinide chemistry with development of new methodologies, algorithms, and computer programs in relativistic quantum chemistry, as well as applications to actinide chemistry and spectroscopy. A new “electrons-only” exact two-component approach has been developed to provide efficient treatments of relativistic effects, while maintaining chemical accuracy. New computational algorithms developed here extend the applicability of relativistic electron-correlation methods to larger molecules. The method-development work in this project also features the first implementation of analytic gradient technique for relativistic electron-correlation methods, which provides significantly enhanced ability to compute properties for molecules containing actinides. The applicability and usefulness of these new methods and computer programs have been demonstrated in calculations of actinide-containing molecules to facilitate understanding of actinide chemistry and spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Study of the Efficacy of Using Nuclear Resonance Fluorescence with Quasi-Monoenergetic Gamma-Ray Sources for Nuclear Safeguards Assay

We have studied the efficacy of using nuclear resonance fluorescence (NRF)-based techniques to assay spent nuclear fuel for Pu content using quasi-monoenergetic sources. We have developed two techniques to precisely determine the Pu content in a fuel rod/pin. One of our approaches is virtually free of systematic uncertainties. Using analytical models, we have determined the amount of time required to measure the Pu content in spent nuclear fuel rods and spent fuel assemblies to within 1% precision. We note that Pu content can be determined in a fuel assembly about as fast as in a single fuel pin. The performance of NRF-based assay techniques with improved photon sources, which are currently under development, will also estimated. For follow-on research we propose to: (1) Construct research prototype detection systems for both of the NRF-based assay systems proposed in this paper and measure their calibration curves; (2) Determine the systematic errors associated with both assay methods, explore ways to reduce the errors and fold the results into future performance calculations; (3) Develop an algorithm to assay a fuel assembly; (4) Perform validation measurements using a single pin and scaled assemblies; (5) Research and develop current-mode detection and/or threshold detection techniques to improve assay times; (6) Characterize the flux of newly constructed sources and fold the results into the calculations presented here to determine the feasibility of a variety of proposed sources; and (7) Collaborate with others in the safeguards community to build a prototype system and perform an NRF-based assay demonstration on spent fuel.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-I-45: An Automated Technique to Measure Image Contrast in Clinical CT Images

Purpose: To develop and validate an automated technique for measuring image contrast in chest computed tomography (CT) exams. Methods: An automated computer algorithm was developed to measure the distribution of Hounsfield units (HUs) inside four major organs: the lungs, liver, aorta, and bones. These organs were first segmented or identified using computer vision and image processing techniques. Regions of interest (ROIs) were automatically placed inside the lungs, liver, and aorta and histograms of the HUs inside the ROIs were constructed. The mean and standard deviation of each histogram were computed for each CT dataset. Comparison of the mean and standard deviation of the HUs in the different organs provides different contrast values. The ROI for the bones is simply the segmentation mask of the bones. Since the histogram for bones does not follow a Gaussian distribution, the 25th and 75th percentile were computed instead of the mean. The sensitivity and accuracy of the algorithm was investigated by comparing the automated measurements with manual measurements. Fifteen contrast enhanced and fifteen non-contrast enhanced chest CT clinical datasets were examined in the validation procedure. Results: The algorithm successfully measured the histograms of the four organs in both contrast and non-contrast enhanced chest CT exams. The automated measurements were in agreement with manual measurements. The algorithm has sufficient sensitivity as indicated by the near unity slope of the automated versus manual measurement plots. Furthermore, the algorithm has sufficient accuracy as indicated by the high coefficient of determination, R2, values ranging from 0.879 to 0.998. Conclusion: Patient-specific image contrast can be measured from clinical datasets. The algorithm can be run on both contrast enhanced and non-enhanced clinical datasets. The method can be applied to automatically assess the contrast characteristics of clinical chest CT images and quantify dependencies that may not be captured in phantom data.

60 APPLIED LIFE SCIENCES↗