Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power-law descriptions of the phantom images were in general agreement with real human images. The Singlet approach offered more realistic contrast as compared to the Doublet approach, but at the expense of air bubbles and air pockets that formed during the filling process. Conclusions: The presented physical breast phantoms and their matching virtual breast phantoms offer realistic breast anatomy, patient variability, and ease of use, making them a potential candidate for performing both system quality control testing and virtual clinical trials.

60 APPLIED LIFE SCIENCES↗

Mt. Simon Sandstone - High Resolution CT

High resolution micro-computed tomography images of sandstone from the Mt. Simon formation at different depths. These images provide an insight into the pore structure of the Mt. Simon sandstone (e.g. for potential CO2 storage). This data set can be used to further study the formation as a whole..

CCS,CO2 Sequestration,Carbon Sequestration,Compute↗

Automated intraoperative calibration for prostate cancer brachytherapy

Purpose: Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called ''calibration''. The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. Methods: A device was CAD-designed and precision-engineered, which mechanically couples a calibration phantom with an exact replica of the standard brachytherapy template. From real-time TRUS images acquired from the calibration device and processed by the calibration system, the coordinate transformation between the brachytherapy template and the TRUS images was computed automatically. The system instantly generated a report of the target reconstruction accuracy based on the current calibration outcome. Results: Four types of validation tests were conducted. First, 50 independent, real-time calibration trials yielded an average of 0.57 {+-} 0.13 mm line reconstruction error (LRE) relative to ground truth. Second, the averaged LRE was 0.37 {+-} 0.25 mm relative to ground truth in tests with six different commercial TRUS scanners operating at similar imaging settings. Furthermore, testing with five different commercial stepper systems yielded an average of 0.29 {+-} 0.16 mm LRE relative to ground truth. Finally, the system achieved an average of 0.56 {+-} 0.27 mm target registration error (TRE) relative to ground truth in needle insertion tests through the template in a water tank. Conclusions: The proposed automatic, intraoperative calibration system for prostate cancer brachytherapy has achieved high accuracy, precision, and robustness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Finding curvilinear features in speckled images

A method for finding curves in digital images with speckle noise is described. The solution method differs from standard linear convolutions followed by thresholds in that it explicitly allows curvature in the features. Maximum a posteriori (MAP) estimation is used, together with statistical models for the speckle noise and for the curve-generation process, to find the most probable estimate of the feature, given the image data. The estimation process is first described in general terms. Then, incorporation of the specific neighborhood system and a multiplicative noise model for speckle allows derivation of the solution, using dynamic programming, of the estimation problem. The detection of curvilinear features is considered separately. The detection results allow the determination of the minimal size of detectable feature. Finally, the estimation of linear features, followed by a detection step, is shown for computer-simulated images and for a SAR image of sea ice.

Samadani, Ramin↗

Theoretical studies of the outer envelopes of young stellar objects

With the Monte Carlo code developed by Whitney and Hartmann, a series of models was computed of scattering in disks around young stellar objects. The code calculates scattering by dust, including polarization, in arbitrary geometries. By computing model images, it was found that disk, by themselves, around young stellar objects would be very difficult to detect with present day imaging techniques. In comparing these images to observations of young stellar objects which show diffuse structure, little resemblance was found. A flared disk system will only give high polarization when viewed edge-on, and the position angle is always oriented perpendicular to the disk plane. This suggests that an envelope, perhaps the remnant infalling envelope, must be present to scatter more stellar light than a disk can, and obscure the star at many inclinations. A grid was computed of models of scattering in a disk+envelope system. Evidence is presented that the wind of the pre-main sequence object FU Orionis arises from the surface of the luminous prostellar accretion disk. A disk wind model calculated assuming radiative equilibrium explains the differential behavior of the observed asymmetrical absorption line profiles. The model predicts that strong lines should be asymmetric and blueshifted, while weak lines should be symmetric and doubled peaked due to disk rotation, in agreement with observations.

Hartmann, Lee↗

Stack filter classifiers

Just as linear models generalize the sample mean and weighted average, weighted order statistic models generalize the sample median and weighted median. This analogy can be continued informally to generalized additive modeels in the case of the mean, and Stack Filters in the case of the median. Both of these model classes have been extensively studied for signal and image processing but it is surprising to find that for pattern classification, their treatment has been significantly one sided. Generalized additive models are now a major tool in pattern classification and many different learning algorithms have been developed to fit model parameters to finite data. However Stack Filters remain largely confined to signal and image processing and learning algorithms for classification are yet to be seen. This paper is a step towards Stack Filter Classifiers and it shows that the approach is interesting from both a theoretical and a practical perspective.

99 GENERAL AND MISCELLANEOUS↗

Validating Fiducial Markers for Image-Guided Radiation Therapy for Accelerated Partial Breast Irradiation in Early-Stage Breast Cancer

Purpose: Image-guided radiation therapy (IGRT) may be beneficial for accelerated partial breast irradiation (APBI). The goal was to validate the use of intraparenchymal textured gold fiducials in patients receiving APBI. Methods and Materials: Twenty-six patients were enrolled on this prospective study that had three or four textured gold intraparenchymal fiducials placed at the periphery of the lumpectomy cavity and were treated with three-dimensional (3D) conformal APBI. Free-breathing four-dimensional computed tomography image sets were obtained pre- and posttreatment, as were daily online megavoltage (MV) orthogonal images. Intrafraction motion, variations in respiratory motion, and fiducial marker migration were calculated using the 3D coordinates of individual fiducials and a calculated center of mass (COM) of the fiducials. We also compared the relative position of the fiducial COM with the geometric center of the seroma. Results: There was less than 1 mm of intrafraction respiratory motion, variation in respiratory motion, or fiducial marker migration. The change in seroma position relative to the fiducial COM was 1 mm {+-} 1 mm. The average position of the geometric seroma relative to the fiducial COM pretreatment compared with posttreatment was 1 mm {+-} 1 mm. The largest daily variation in displacement when using bony landmark was in the anteroposterior direction and two standard deviations (SD) of this variation was 10 mm. The average variation in daily separation between the fiducial pairs from daily MV images was 3 mm {+-} 3 mm therefore 2 SD is 6 mm. Conclusion: Fiducial markers are stable throughout the course of APBI. Planning target volume margins when using bony landmarks should be 10 mm and can be reduced to 6 mm if using fiducials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-FG-BRB-08: Challenges, Limitations and Future Outlook Towards Clinical Translation of Proton Acoustic Range Verification

Purpose: To report our investigations of proton acoustic imaging, including computer simulations and preliminary experimental studies at clinical facilities. The ultimate achievable accuracy, sensitivity and clinical translation challenges are discussed. Methods: The acoustic pulse due to pressure rise was estimated using finite element model. Since the ionoacoustic pulse is highly dependent on the proton pulse width and energy, multiple pulse widths were studied. Based on the received signal spectrum at piezoelectric ultrasound transducer with consideration of random thermal noise, maximum spatial resolution of the proton-acoustic imaging modality was calculated. The simulation studies defined the design specifications of the system to detect proton acoustic signal from Hitachi and Mevion clinical machines. A 500 KHz hydrophone with 100 dB amplification was set up in a water tank placed in front of the proton nozzle A 40 MHz data acquisition was synchronized by a trigger signal provided by the machine. Results: Given 30–800 mGy dose per pulse at the Bragg peak, the minimum number of protons detectable by the proton acoustic technique was on the order of 10×10^6 per pulse. The broader pulse widths produce signal with lower acoustic frequencies, with 10 µs pulses producing signals with frequency less than 100 kHz. As the proton beam pulse width increases, a higher dose rate is required to measure the acoustic signal. Conclusion: We have established the minimal detection limit for protonacoustic range validation for a variety of pulse parameters. Our study indicated practical proton-acoustic range verification can be feasible with a pulse shorter than 10 µs, 5×10^6 protons/pulse, 50 nA beam current and a highly sensitive ultrasonic transducer. The translational challenges into current clinical machines include proper magnetic shielding of the measurement equipment, providing a clean trigger signal from the proton machine, providing a shorter proton beam pulse and higher dose per pulse.

60 APPLIED LIFE SCIENCES↗

Dosimetric Effect of Translational and Rotational Errors for Patients Undergoing Image-Guided Stereotactic Body Radiotherapy for Spinal Metastases

Purpose: To investigate the dosimetric effects of translational and rotational patient positioning errors on the treatment of spinal and paraspinal metastases using computed tomography image-guided stereotactic body radiotherapy. The results of this study provide guidance for the treatment planning process and recognition of the dosimetric consequences of daily patient treatment setup errors. Methods and Materials: The data from 20 patients treated for metastatic spinal cancer using image-guided stereotactic body radiotherapy were investigated in this study. To simulate the dosimetric effects of residual setup uncertainties, 36 additional plans (total, 756 plans) were generated for each isocenter (total, 21 isocenters) on the planning computed tomography images, which included isocenter lateral, anteroposterior, superoinferior shifts, and patient roll, yaw, and pitch rotations. Tumor volume coverage and the maximal dose to the organs at risk were compared with those of the original plan. Six daily treatments were also investigated to determine the dosimetric effect with or without the translational and rotational corrections. Results: A 2-mm error in translational patient positioning error in any direction can result in >5% tumor coverage loss and >25% maximal dose increase to the organs at risk. Rotational correction is very important for patients with multiple targets and for the setup of paraspinal patients when the isocenter is away from bony structures. Compared with the original plans, the daily treatment data indicated that translational adjustments could correct most of the setup errors to mean divergences of -1.4% for tumor volume coverage and -0.3% for the maximal dose to the organs at risk. Conclusion: For the best dosimetric results, spinal stereotactic treatments should have setup translational errors of {<=}1 mm and rotational errors of {<=}2 deg.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effects of burial diagenesis on multiscale porosity in the St. Peter Sandstone: An imaging, small-angle, and ultra-small-angle neutron scattering analysis

To examine the effects of burial diagenesis on heirarchical pore structures in sandstone and compare those with the effects of overgrowth formation, we obtained samples of St. Peter Sandstone from drill cores obtained in the Illinois and Michigan Basins. The multiscale pore structure of rocks in sedimentary reservoirs and the mineralogy associated with those pores are critical factors for estimating reservoir properties, including fluid mass in place, permeability, and capillary pressures, as well as geochemical interactions between the rock and the fluid. The combination of small- and ultra-small-angle neutron scattering with backscattered electron or X ray-computed tomographic imaging, or both, provided a means by which pore structures were quantified at scales ranging from aproximately 1 nm to 1 cm—seven orders of magnitude. Larger scale (>10 µm) porosity showed the expected logarithmic decrease in porosity with depth, although there was significant variation in each sample group. However, small- and ultra-small-angle neutron scattering data showed that the proportion of small-scale porosity increased with depth. Porosity distributions were not continuous, but consisted of a series of log normal-like distributions at several distinct scales within these rocks. Fractal dimensions at larger scales decreased (surfaces smoothed) with increasing depth, and those at smaller scales increased (surfaces roughened) and pores become more isolated (higher lacunarity). Furthermore, data suggest that changes in pore-size distributions are controlled by both physical (compaction) and chemical effects (precipitation, cementation, dissolution).

58 GEOSCIENCES↗

TH-CD-202-06: A Method for Characterizing and Validating Dynamic Lung Density Change During Quiet Respiration

Purpose: To obtain a functional relationship that calibrates the lung tissue density change under free breathing conditions through correlating Jacobian values to the Hounsfield units. Methods: Free-breathing lung computed tomography images were acquired using a fast helical CT protocol, where 25 scans were acquired per patient. Using a state-of-the-art deformable registration algorithm, a set of the deformation vector fields (DVF) was generated to provide spatial mapping from the reference image geometry to the other free-breathing scans. These DVFs were used to generate Jacobian maps, which estimate voxelwise volume change. Subsequently, the set of 25 corresponding Jacobian and voxel intensity in Hounsfield units (HU) were collected and linear regression was performed based on the mass conservation relationship to correlate the volume change to density change. Based on the resulting fitting coefficients, the tissues were classified into parenchymal (Type I), vascular (Type II), and soft tissue (Type III) types. These coefficients modeled the voxelwise density variation during quiet breathing. The accuracy of the proposed method was assessed using mean absolute difference in HU between the CT scan intensities and the model predicted values. In addition, validation experiments employing a leave-five-out method were performed to evaluate the model accuracy. Results: The computed mean model errors were 23.30±9.54 HU, 29.31±10.67 HU, and 35.56±20.56 HU, respectively, for regions I, II, and III, respectively. The cross validation experiments averaged over 100 trials had mean errors of 30.02 ± 1.67 HU over the entire lung. These mean values were comparable with the estimated CT image background noise. Conclusion: The reported validation experiment statistics confirmed the lung density modeling during free breathing. The proposed technique was general and could be applied to a wide range of problem scenarios where accurate dynamic lung density information is needed. This work was supported in part by NIH R01 CA0096679.

60 APPLIED LIFE SCIENCES↗

Imaging phased telescope array study

The problems encountered in obtaining a wide field-of-view with large, space-based direct imaging phased telescope arrays were considered. After defining some of the critical systems issues, previous relevant work in the literature was reviewed and summarized. An extensive list was made of potential error sources and the error sources were categorized in the form of an error budget tree including optical design errors, optical fabrication errors, assembly and alignment errors, and environmental errors. After choosing a top level image quality requirment as a goal, a preliminary tops-down error budget allocation was performed; then, based upon engineering experience, detailed analysis, or data from the literature, a bottoms-up error budget reallocation was performed in an attempt to achieve an equitable distribution of difficulty in satisfying the various allocations. This exercise provided a realistic allocation for residual off-axis optical design errors in the presence of state-of-the-art optical fabrication and alignment errors. Three different computational techniques were developed for computing the image degradation of phased telescope arrays due to aberrations of the individual telescopes. Parametric studies and sensitivity analyses were then performed for a variety of subaperture configurations and telescope design parameters in an attempt to determine how the off-axis performance of a phased telescope array varies as the telescopes are scaled up in size. The Air Force Weapons Laboratory (AFWL) multipurpose telescope testbed (MMTT) configuration was analyzed in detail with regard to image degradation due to field curvature and distortion of the individual telescopes as they are scaled up in size.

Harvey, James E.↗

CESDIS

CESDIS, the Center of Excellence in Space Data and Information Sciences was developed jointly by NASA, Universities Space Research Association (USRA), and the University of Maryland in 1988 to focus on the design of advanced computing techniques and data systems to support NASA Earth and space science research programs. CESDIS is operated by USRA under contract to NASA. The Director, Associate Director, Staff Scientists, and administrative staff are located on-site at NASA's Goddard Space Flight Center in Greenbelt, Maryland. The primary CESDIS mission is to increase the connection between computer science and engineering research programs at colleges and universities and NASA groups working with computer applications in Earth and space science. Research areas of primary interest at CESDIS include: 1) High performance computing, especially software design and performance evaluation for massively parallel machines; 2) Parallel input/output and data storage systems for high performance parallel computers; 3) Data base and intelligent data management systems for parallel computers; 4) Image processing; 5) Digital libraries; and 6) Data compression. CESDIS funds multiyear projects at U. S. universities and colleges. Proposals are accepted in response to calls for proposals and are selected on the basis of peer reviews. Funds are provided to support faculty and graduate students working at their home institutions. Project personnel visit Goddard during academic recess periods to attend workshops, present seminars, and collaborate with NASA scientists on research projects. Additionally, CESDIS takes on specific research tasks of shorter duration for computer science research requested by NASA Goddard scientists.

Source record↗

TU-A-12A-10: Robust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation

Purpose: Recent advances in medical imaging technologies provide opportunities to quantify the tumor phenotype throughout the course of treatment non-invasively. The emerging field of Radiomics addresses this by converting medical images into minable data by applying a large number of quantitative imaging algorithms. Accurate tumor segmentation is one of the main challenges of Radiomics. It has been shown that semiautomatic segmentation approaches efficiently reduce inter-observer variability as compared to the time consuming manual delineations. In this study, a semiautomatic volumetric segmentation algorithm, implemented in the free and publicly available 3D-Slicer platform, was investigated in terms of its robustness for Radiomics features quantification. Methods: Fifty-six 3D-Radiomics features, quantifying phenotypic differences based on the tumor intensity, shape and texture, were extracted from the computed tomography images of twenty lung cancer patients. These Radiomics features were derived from the 3D-tumor volumes defined by three independent observers twice using 3D-Slicer, and compared to manual slice-by-slice delineations of five independent physicians in terms of intra-class correlation coefficient (ICC) and feature range. Results: Radiomics features extracted from 3D-Slicer segmentations had significantly higher reproducibility (ICC= 0.85 0.15, p=0.0009) compared to the features extracted from the manual segmentations (ICC= 0.77 0.17). Furthermore, the features extracted from 3D-Slicer based segmentations, spread over significantly smaller range across observers as compared to those of the manual delineations (p= 3.819e-07). Moreover, the features derived from 3D-Slicer segmentations overlapped in range with those of the manual delineations, as the lower(higher) limit(s) being significantly higher(lower) for the 3D-Slicer features (p= 0.007, p= 5.863e-06). Conclusion: 3D-Slicer based semiautomatic segmentation significantly improves the robustness of radiomics features and thus could serve as a potential alternative to the time consuming manual segmentation process. So 3D-Slicer can have a large application in Radiomics, and be employed for high-throughput data mining research of medical imaging in clinical oncology.

60 APPLIED LIFE SCIENCES↗

A Co-Registered In-Situ and Ex-Situ Tensile Properties Dataset from a Laser Powder Bed Fusion Additive Manufacturing Process (Peregrine v2023-11)

This release contains a co-registered in-situ and ex-situ Peregrine dataset from five Concept Laser M2 Laser Powder Bed Fusion (L-PBF) stainless steel 316L builds containing 6,299 SS-J3 individually tracked tensile coupons. These data were collected at the Manufacturing Demonstration Facility (MDF) located at Oak Ridge National Laboratory (ORNL). The dataset includes layer-wise visible-light in-situ imaging data, the laser scan paths and parameters, in-situ temporal sensor data, room-temperature static tensile test results, and the target part geometries. Additionally, anomaly detections produced by a modified Dynamic Segmentation Convolutional Neural Network (DSCNN) are provided.

36 MATERIALS SCIENCE↗

On the use of the earth resources technology satellite /LANDSAT-1/ in optical oceanography

Observations of the Gulf Stream System in the Gulf of Mexico were obtained in synchronization with LANDSAT-1. Computer enhanced images, which are necessary to extract useful oceanic information, show that the current can be observed by color (diffuse radiance) or sea state (specular radiance) effects associated with the cyclonic boundary even in the absence of a surface thermal signature. The color effect relates to the spectral variations in the optical properties of the water and its suspended particles, and is studied by radiative transfer theory. Significant oceanic parameters identified are: the probability of forward scattering, and the ratio of scattering to total attenuation. Several spectra of upwelling diffuse light are computed as a function of the concentration of particles and yellow substance.

Maul, G. A.↗

Redshifting galaxies from DESI to JWST CEERS: Correction of biases and uncertainties in quantifying morphology

Observations of high-redshift galaxies with unprecedented detail have now been rendered possible with the James Webb Space Telescope (JWST). However, accurately quantifying their morphology remains uncertain due to potential biases and uncertainties. To address this issue, we used a sample of 1816 nearby DESI galaxies, with a stellar mass range of 10 9.75 - 11.25 M ⊙ , to compute artificial images of galaxies of the same mass located at 0.75 ≤ z ≤ 3 and observed at rest-frame optical wavelength in the Cosmic Evolution Early Release Science (CEERS) survey. We analyzed the effects of cosmological redshift on the measurements of Petrosian radius (R p ), half-light radius (R 50 ), asymmetry (A), concentration (C), axis ratio (q), and Sérsic index (n). Our results show that R p and R 50 , calculated using non-parametric methods, are slightly overestimated due to PSF smoothing, while R 50 , q, and n obtained through fitting a Sérsic model does not exhibit significant biases. By incorporating a more accurate noise effect removal procedure, we improve the computation of A over existing methods, which often overestimate, underestimate, or lead to significant scatter of noise contributions. Due to PSF asymmetry, there is a minor overestimation of A for intrinsically symmetric galaxies. However, for intrinsically asymmetric galaxies, PSF smoothing dominates and results in an underestimation of A, an effect that becomes more significant with higher intrinsic A or at lower resolutions. Moreover, PSF smoothing also leads to an underestimation of C, which is notably more pronounced in galaxies with higher intrinsic C or at lower resolutions. We developed functions based on resolution level, defined as R p /FWHM, for correcting these biases and the associated statistical uncertainties. Applying these corrections, we measured the bias-corrected morphology for the simulated CEERS images and we find that the derived quantities are in good agreement with their intrinsic values – except for A, which is robust only for angularly large galaxies where R p /FWHM ≥ 5. Our correction functions can be applied to other surveys, offering valuable tools for future studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Total Microvessel Perimeter Per Tumor Area Is a Predictor of Radiosensitivity in Early-Stage Glottic Carcinoma

Purpose: To confirm that total number of microvessels per tumor area (TN/TA) and total microvessel perimeter per tumor area (TP/TA) are predictors for radiosensitivity in early-stage glottic carcinoma. Methods and Materials: One hundred twenty consecutive patients with T1-2N0M0 glottic cancer who were treated with radical radiotherapy in three different hospitals in Japan were included in this study. Biopsy specimens from patients were immunostained with anti-CD31 antibody. The TN/TA and TP/TA of each sample were analyzed using a computer-assisted image analysis system. Patients were stratified into high and low groups according to the cut-off values derived from receiver operating characteristic curve analysis. Progression-free survival rates of the different groups were compared. The relationship of microvessel perimeter to vessel maturation was also discussed. Results: Survival analysis showed higher TP/TA to be associated significantly with longer progression-free survival, as compared with the lower-level group (p = 0.031). In multivariate analysis, both TP/TA (p = 0.037) and T stage (p < 0.001) proved to be independent predictive factors. Microvessel perimeter correlated closely with vessel maturity, which suggests that a tumor with high TP/TA contains more functional vessels and as a result contains more oxygenated and radiosensitive cells. Conclusion: Assessment of TP/TA in biopsy specimens, using a computer-assisted analysis system, can predict the radiosensitivity of early-stage glottic carcinoma. High TP/TA may be a better indication for radiotherapy than for partial laryngectomy or laser excision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗