Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Study of Semimagnetic Mn-Doped WO{sub 3} Nanoparticles Synthesised by Precipitation Method: Hydrogenation Creates a Promising DMS

Abstract Tungsten oxide (WO{sub 3}) nanoparticles doped with different amounts of manganese ions (W{sub 1−x}Mn{sub x}O{sub 3}, where x = 0.011, 0.022 and 0.044) were synthesised by hydraulic acid-assisted precipitation, followed by thermal calcinations. The powders were characterised by X-ray fluorescence (XRF), X-ray diffraction (XRD), diffuse reflectance spectroscopy (DRS) and magnetic measurements. The monoclinic structure at room temperature (∼293 K) found for un-doped WO{sub 3} was preserved even with Mn doping. However, doping with Mn ions caused decease in unit-cell volume and slight increase in crystallite size (CS) of host WO{sub 3}. The hydrogenation was observed to corrode the crystallites without changing in crystalline structure. Controllable room-temperature ferromagnetic (RT-FM) properties were obviously observed with hydrogenated WO{sub 3} doped with Mn. In addition, there existed an optimum doping concentration of Mn in WO{sub 3} to obtain superior FM properties. Therefore, Mn-doped WO{sub 3} nanopowders, owning to these amazingly tunable magnetic properties, could be considered a potential candidate for many applications partially required FM properties such as optical phosphors and catalysts.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Understanding and control of Zener pinning via phase field and ensemble learning

Zener pinning refers to the dispersion of fine particles which influences grain size distribution via movement of grain boundaries in a polycrystalline material. Grain size distribution in polycrystals has a significant impact on their properties including physical, chemical, mechanical, and optical to name a few. We explore the use of Phase-field modeling and machine-learning techniques to understand and improve the control of grain size distribution via Zener pinning in polycrystalline materials. We develop a machine learning model that determines the relative importance of various parameters to exercise microstructure control via Zener pinning. Our workflow combines high-throughput phase-field simulations and machine learning to address the computational bottlenecks associated with large-scale simulations as well as identify features necessary for microstructure control in polycrystals. A random forest (RF) regression model was developed to predict grain sizes based on five Phase-field model parameters, achieving an average prediction error of 0.72 nm for the training data and 1.44 nm for the test data. The importance of the input parameters is analyzed using the SHapley Additive exPlanations (SHAP) approach which reveals that diffusivity, volume fraction, and particle diameter are the most important parameters in determining the final grain size. These findings will allow us to select the best second-phase particles, optimize grain size distributions and thus design microstructures with the desired properties. The developed method is a highly versatile and generalizable approach that can be used to assess the combined effects of individual features in the presence of multiple variables.

36 MATERIALS SCIENCE↗

Gamma Knife Radiosurgery for Skull Base Meningiomas: Long-Term Radiologic and Clinical Outcome

Purpose: To analyze the long-term outcomes in patients with skull base meningiomas (SBMNGs) treated with Gamma Knife radiosurgery (GKRS). Methods and Materials: Of the 98 consecutive patients with SBMNGs treated with GKRS between 1998 and 2002, 63 were followed up for more than 48 months. The mean ({+-}SD) age of the patients was 50 {+-} 12 years, the mean tumor volume was 6.5 cm{sup 3} (range, 0.5-18.4 cm{sup 3}), the mean marginal dose was 12.6 Gy (range, 7.0-20.0 Gy), and the mean follow-up duration was 77 {+-} 18 months. The mean number of shots was 13.7 {+-} 3.8. The tumor volume was decreased at the last follow-up in 28 patients (44.4%) and increased in 6 (9.6%). The actuarial tumor control rate was 90.2% at 5 years. No notable prognostic factor related to tumor control was identified. Ten patients (15.9%) with a cranial neuropathy showed unfavorable outcomes. The rate of improvement in patients with a cranial neuropathy was 45.1%. Age >70 years was likely correlated with an unfavorable outcome in patients with cranial neuropathy (odds ratio = 0.027; p = 0.025; 95% confidence interval 0.001-0.632). Cavernous sinus location was significantly associated with improvement of a cranial neuropathy (odds ratio = 7.314; p = 0.007; 95% confidence interval 1.707-31.34). Conclusions: Gamma Knife radiosurgery is an effective modality for the treatment of SBMNGs and provides favorable outcomes in patients with cranial neuropathy, even in the long-term follow-up period. However, radiosurgery for patients with no or only mild symptoms should be performed cautiously because neither complication rate is low enough to be negligible, especially in elderly patients. A cranial neuropathy by MNGs involving the cavernous sinus seems to have a higher chance of improvement after radiosurgery than other SBMNGs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ionic liquid mediated one-step perpendicular assembly in block copolymer thin films for ultrafiltration membrane applications

The rapid rise of oil and gas, petrochemical, food processing, and pharmaceutical industries has added a complex mixture of contaminants like oil, particulates, metals, and other organic compounds to wastewater. Multipurpose membranes with precise pore structure can offer a solution to this problem and block copolymers (BCP) can be used to achieve such structures. Achieving vertical assembly of BCP domains provides a perfect template for developing uniform through film channels for separation and transport of material, besides being useful for the rectification of defects in photolithography patterns. Producing such morphologies may require extensive film/substrate processing and is not always feasible for scale-up. With this article, we demonstrate a facile solution casting method to induce vertical domain assembly in as-cast diblock copolymer thin films in the presence of an ionic liquid (IL) additive that preferentially segregates to one block and neutralizes interfacial interactions. We also show the tunability of domain sizes by controlling the additive concentration. These vertically aligned morphologies are important for the development of next-generation lithographic techniques and form excellent templates for ultrafiltration membranes with uniform pore sizes. In conclusion, this article demonstrates how IL additives can be used to obtain stable non-equilibrium morphologies in as-cast BCP films and the effect of BCP molecular mass, block volume fractions, and IL content on self-assembly.

59 BASIC BIOLOGICAL SCIENCES↗

Safety of Single-Site Laparoscopic Surgery Requiring Perioperative Heparinization in Colorectal Cancer: Propensity Score-Matched Analysis

Background: We assessed the feasibility and safety of single-site laparoscopic surgery for patients with colorectal cancer who required perioperative heparinization. Methods: This retrospective study reviewed the medical records of 390 patients who underwent single-site laparoscopic surgery for colorectal cancer from January 2010 to December 2016. Antithrombotic drugs were stopped preoperatively and heparin was administered according to the operative risk of each patient, based on consultation with the cardiologist physician or neurosurgeon. Propensity score modeling was utilized to adjust for baseline characteristics. Results: Of 390 patients, 29 were treated with standard bridging intravenous heparin therapy. Propensity matching identified 119 patients: 22 patients in the heparinization group and 97 in the control group. The matched groups were not significantly different in operation times, bleeding volumes, or conversion rate. The mean postoperative hospital stay was 17.9 days in the heparinization group and 9.5 days in the control group (p = 0.034). Postoperative bleeding was observed in 4 patients (18.2%) in the heparinization group and 11 patients (11.4%) in the control group (p = 0.646), while other complications were similar in the two study groups (p = 0.502). Of these other complications, thromboembolic events were observed in two patients in the heparinization group and one patient in the control group. Conclusions: We found that single-site laparoscopic surgery for colorectal cancer with heparinization was feasible and safe. Heparinization did not increase the risk of postoperative bleeding complications, but postoperative hospital stay was prolonged.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nanoparticle flow, ordering and self-assembly.

Nanoparticles are now more than ever being used to tailor materials function and performance in differentiating technologies because of their profound effect on thermo-physical, mechanical and optical properties. The most feasible way to disperse particles in a bulk material or control their packing at a substrate is through fluidization in a carrier, followed by solidification through solvent evaporation/drying/curing/sintering. Unfortunately processing particles as concentrated, fluidized suspensions into useful products remains an art largely because the effect of particle shape and volume fraction on fluidic properties and suspension stability remains unexplored in a regime where particle-particle interaction mechanics is prevalent. To achieve a stronger scientific understanding of the factors that control nanoparticle dispersion and rheology we have developed a multiscale modeling approach to bridge scales between atomistic and molecular-level forces active in dense nanoparticle suspensions. At the largest length scale, two 'coarse-grained' numerical techniques have been developed and implemented to provide for high-fidelity numerical simulations of the rheological response and dispersion characteristics typical in a processing flow. The first is a coupled Navier-Stokes/discrete element method in which the background solvent is treated by finite element methods. The second is a particle based method known as stochastic rotational dynamics. These two methods provide a new capability representing a 'bridge' between the molecular scale and the engineering scale, allowing the study of fluid-nanoparticle systems over a wide range of length and timescales as well as particle concentrations. To validate these new methodologies, multi-million atoms simulations explicitly including the solvent have been carried out. These simulations have been vital in establishing the necessary 'subgrid' models for accurate prediction at a larger scale and refining the two coarse-grained methodologies.

99 GENERAL AND MISCELLANEOUS↗

Computer-aided detection of clustered microcalcifications in multiscale bilateral filtering regularized reconstructed digital breast tomosynthesis volume

Purpose: Develop a computer-aided detection (CADe) system for clustered microcalcifications in digital breast tomosynthesis (DBT) volume enhanced with multiscale bilateral filtering (MSBF) regularization. Methods: With Institutional Review Board approval and written informed consent, two-view DBT of 154 breasts, of which 116 had biopsy-proven microcalcification (MC) clusters and 38 were free of MCs, was imaged with a General Electric GEN2 prototype DBT system. The DBT volumes were reconstructed with MSBF-regularized simultaneous algebraic reconstruction technique (SART) that was designed to enhance MCs and reduce background noise while preserving the quality of other tissue structures. The contrast-to-noise ratio (CNR) of MCs was further improved with enhancement-modulated calcification response (EMCR) preprocessing, which combined multiscale Hessian response to enhance MCs by shape and bandpass filtering to remove the low-frequency structured background. MC candidates were then located in the EMCR volume using iterative thresholding and segmented by adaptive region growing. Two sets of potential MC objects, cluster centroid objects and MC seed objects, were generated and the CNR of each object was calculated. The number of candidates in each set was controlled based on the breast volume. Dynamic clustering around the centroid objects grouped the MC candidates to form clusters. Adaptive criteria were designed to reduce false positive (FP) clusters based on the size, CNR values and the number of MCs in the cluster, cluster shape, and cluster based maximum intensity projection. Free-response receiver operating characteristic (FROC) and jackknife alternative FROC (JAFROC) analyses were used to assess the performance and compare with that of a previous study. Results: Unpaired two-tailedt-test showed a significant increase (p < 0.0001) in the ratio of CNRs for MCs with and without MSBF regularization compared to similar ratios for FPs. For view-based detection, a sensitivity of 85% was achieved at an FP rate of 2.16 per DBT volume. For case-based detection, a sensitivity of 85% was achieved at an FP rate of 0.85 per DBT volume. JAFROC analysis showed a significant improvement in the performance of the current CADe system compared to that of our previous system (p = 0.003). Conclusions: MBSF regularized SART reconstruction enhances MCs. The enhancement in the signals, in combination with properly designed adaptive threshold criteria, effective MC feature analysis, and false positive reduction techniques, leads to a significant improvement in the detection of clustered MCs in DBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal conductivity of 3D-printed block-copolymer-inspired structures

This study primarily focuses on examining the impact that geometric structure has on thermal conductivity of multi-phase constructs in different 3D-printed poly(lactic acid), PLA, samples. The investigated structures are inspired by morphologies formed by diblock copolymers: lamellae, hexagonally packed cylinders, and gyroid. This research also investigates how volume percentage and material combination influence the thermal conductivity of these structures. Further, the samples can be tailored to simulate various thermal management structures observed in practical applications, such as thermal interface materials in electronic devices. Thermal conductivity ratio is controlled using air, the least conductive material at 0.026 W/(m K), PLA at 0.136 W/(m K), and thermal paste at 5.11 W/(m K). Different models were tested against thermal conductivity measurements in order to capture the effect of material type (PLA-Air versus PLA-Thermal Paste), volume percentage, structure, and orientation. Simple, effective medium models were good predictions of thermal conductivity in lamellar structures, but it was necessary to develop models for conduction through cylindrical and gyroid structures. Finally, all results were normalized to find a universal model that is independent of structure and material. This approach provides a simple method to predict how to reduce or enhance transport properties and heat management capabilities of 3D printed objects.

36 MATERIALS SCIENCE↗

Vapor-cavity-QED system for quantum computation and communication

In this work, we propose performing key operations in quantum computation and communication using room-temperature atoms moving across a grid of high-quality-factor, small-mode-volume cavities. These cavities enable high-cooperativity interactions with single atoms to be achieved with a characteristic timescale much shorter than the atomic transit time, allowing multiple coherent operations to take place. We study scenarios where we can drive a Raman transition to generate photons with specific temporal shapes and to absorb, and hence detect, single photons. The strong atom-cavity interaction can also be used to implement the atom-photon controlled-phase gate, which can then be used to construct photon-photon gates, create photonic cluster states, and perform nondemolition detection of single photons. We provide numerics validating our methods and discuss the implications of our results for several applications.

Austin, Sharoon [National Institute of Standards a↗

Influence of Tool Runout on Force Measurement During Internal Void Monitoring for Friction Stir Welding of 6061-T6 Aluminum

Abstract The goal of this research was to examine how altering the amount of friction stir tool eccentricity while controlling the amount of slant in the tool shoulder (drivers of oscillatory process forces) effects the generation of process force transients during sub-surface void interaction. The knowledge gained will help improve the accuracy of force-based void monitoring methods that have the potential to reduce the need for post-weld inspection. Process force transients during sub-surface void formation were examined for multiple tools with varying magnitudes of kinematic runout. The eccentric motion of the tool produced oscillations in the process forces at the tools rotational frequency that became distorted when features (flats) on the tool probe interacted with voided volumes, generating an amplitude in the force signals at three times the tool rotational frequency (for three-flat tools). A larger tool eccentricity generates a larger amplitude in the force signals at the tool’s rotational frequency that holds a larger potential to create a distortion during void interaction. It was determined that once void becomes large enough to produce an interaction that generates an amplitude at the third harmonic larger than 30% of the amplitude at the rotational frequency in a weld with no interaction (amplitude solely at rotational frequency), the trailing edge of the tool shoulder cannot fully consolidate the void, i.e., it will remain in the final weld. Additionally, once the void exceeds a certain size, the amplitudes of the third harmonics saturate at 70% of the amplitude at the rotational frequency during full consolidation. The interaction between the eccentric probe and sub-surface void was isolated by ensuring any geometric imperfection in the shoulder (slant) with respect to the rotational axis was removed. The results suggest that geometric imperfections (eccentricity and slant) with respect to the tool’s rotational axis must be known when developing a void monitoring method from force transients of this nature.

Engineering↗

Final Report for the project titled "Enabling Supernova Computations by Integrated Transport and Provisioning Methods Optimized for Dedicated Channels"

A high-speed optical circuit network is one that offers users rate-guaranteed connectivity between two endpoints, unlike today’s IP-routed Internet in which the rate available to a pair of users fluctuates based on the volume of competing traffic. This particular research project advanced our understanding of circuit networks in two ways. First, transport protocols were developed for circuit networks. In a circuit network, since bandwidth resources are reserved for each circuit on an end-to-end basis (much like how a person reserves a seat on every leg of a multi-segment flight), and the sender is limited to send at the rate of the circuit, there is no possibility of congestion during data transfer. Therefore, no congestion control functions are necessary in a transport protocol designed for circuits. However, error control and flow control are still required because bits can become errored due to noise and interference even on highly reliable optical links, and receivers can, due to multitasking or other reasons, not deplete the receive buffer fast enough to keep up with the sending rate (e.g., if the receiving host is multitasking between receiving a file transfer and some other computation). In this work, we developed two transport protocols for circuits, both of which are described below. Second, this project developed techniques for internetworking different types of connection-oriented networks, which are of two types: circuit-switched or packet-switched. In circuit-switched networks, multiplexing on links is “position based,” where “position” refers to the frequency, time slot, and port (fiber), while connection-oriented packet-switched networks use packet header information to demultiplex packets and switch them from node to node. The latter are commonly referred to as virtual circuit networks. Examples of circuit networks are time-division multiplexed Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH) and Wavelength Division Multiplexing (WDM) networks, while examples of virtual-circuit networks are MultiProtocol Label Switched (MPLS) networks and Ethernet Virtual Local Area Network (VLAN) networks. A series of new technologies have been developed to carry Ethernet VLAN tagged frames on SONET/SDH and WDM networks, such as Generic Framing Procedure (GFP) and ITU G.709, respectively. These technologies form the basis of our solution for connection-oriented internetworking. The benefit of developing such an architecture is that it allows different providers to choose different connection-oriented networking technologies for their networks, and yet be able to allow their customers to connect to those of other providers. As Metcalfe, the inventor of Ethernet, noted, the value of a network service grows exponentially with the number of endpoints to which any single endpoint can connect. Therefore internetworking solutions are key to commercial success. The technical effectiveness of our solutions was measured with proof-of-concept prototypes and experiments. These solutions were shown to be highly effective. Economic feasibility requires business case analyses that were beyond the scope of this project. The project results are beneficial to the public as they demonstrate the viability of simultaneously supporting different types of networks and data communication services much like the variety of services available for the transportation of people and goods. For example, Fedex service offers a deadline based delivery while the USPS offers basic package delivery service. Similarly, a circuit network can offer a deadline based delivery of a data file while the IP-routed network offers only basic delivery service with no guarantees. Two project Web sites, 13 publications, 7 software programs, 21 presentations resulted from this work. This report provides the complete list of publications, software programs and presentations. As for student education and training (human resources), this DOE project, along with an NSF project, jointly supported two postdoctoral fellowships, three PhDs, three Masters, and two undergraduate students. Specifically, two of the Masters students were directly funded on this DOE project.

99 GENERAL AND MISCELLANEOUS↗

MPACT Fast Neutron Multiplicity System Prototype Development

This document serves as both an FY2103 End-of-Year and End-of-Project report on efforts that resulted in the design of a prototype fast neutron multiplicity counter leveraged upon the findings of previous project efforts. The prototype design includes 32 liquid scintillator detectors with cubic volumes 7.62 cm in dimension configured into 4 stacked rings of 8 detectors. Detector signal collection for the system is handled with a pair of Struck Innovative Systeme 16-channel digitizers controlled by in-house developed software with built-in multiplicity analysis algorithms. Initial testing and familiarization of the currently obtained prototype components is underway, however full prototype construction is required for further optimization. Monte Carlo models of the prototype system were performed to estimate die-away and efficiency values. Analysis of these models resulted in the development of a software package capable of determining the effects of nearest-neighbor rejection methods for elimination of detector cross talk. A parameter study was performed using previously developed analytical methods for the estimation of assay mass variance for use as a figure-of-merit for system performance. A software package was developed to automate these calculations and ensure accuracy. The results of the parameter study show that the prototype fast neutron multiplicity counter design is very nearly optimized under the restraints of the parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Potential of Proton Therapy to Reduce Acute Hematologic Toxicity in Concurrent Chemoradiation Therapy for Esophageal Cancer

Purpose: Radiation therapy dose escalation using a simultaneous integrated boost (SIB) is predicted to improve local tumor control in esophageal cancer; however, any increase in acute hematologic toxicity (HT) could limit the predicted improvement in patient outcomes. Proton therapy has been shown to significantly reduce HT in lung cancer patients receiving concurrent chemotherapy. Therefore, we investigated the potential of bone marrow sparing with protons for esophageal tumors. Methods and Materials: Twenty-one patients with mid-esophageal cancer who had undergone conformal radiation therapy (3D50) were selected. Two surrogates for bone marrow were created by outlining the thoracic bones (bone) and only the body of the thoracic vertebrae (TV) in Eclipse. The percentage of overlap of the TV with the planning treatment volume was recorded for each patient. Additional plans were created retrospectively, including a volumetric modulated arc therapy (VMAT) plan with the same dose as for 3D50; a VMAT SIB plan with a dose prescription of 62.5 Gy to the high-risk subregion within the planning treatment volume; a reoptimized TV-sparing VMAT plan; and a proton therapy plan with the same SIB dose prescription. The bone and TV dose metrics were recorded and compared across all plans and variations with respect to PTV and percentage of overlap for each patient. Results: The 3D50 plans showed the highest bone mean dose and TV percentage of volume receiving ≥30 Gy (V{sub 30Gy}) for each patient. The VMAT plans irradiated a larger bone V{sub 10Gy} than did the 3D50 plans. The reoptimized VMAT62.5 VT plans showed improved sparing of the TV volume, but only the proton plans showed significant sparing for bone V{sub 10Gy} and bone mean dose, especially for patients with a larger PTV. Conclusions: The results of the present study have shown that proton therapy can reduced bone marrow toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-BRB-12: Nanoscintillator Fiber-Optic Detector System for Microbeam Radiation Therapy Dosimetry

Purpose: Microbeam Radiation Therapy (MRT) is an experimental radiation therapy that has demonstrated a higher therapeutic ratio than conventional radiation therapy in animal studies. There are several roadblocks in translating the promising treatment technology to clinical application, one of which is the lack of a real-time, high-resolution dosimeter. Current clinical radiation detectors have poor spatial resolution and, as such, are unsuitable for measuring microbeams with submillimeter-scale widths. Although GafChromic film has high spatial resolution, it lacks the real-time dosimetry capability necessary for MRT preclinical research and potential clinical use. In this work we have demonstrated the feasibility of using a nanoscintillator fiber-optic detector (nanoFOD) system for real-time MRT dosimetry. Methods: A microplanar beam array is generated using a x-ray research irradiator and a custom-made, microbeam-forming collimator. The newest generation nanoFOD has an effective size of 70 µm in the measurement direction and was calibrated against a kV ion chamber (RadCal Accu-Pro) in open field geometry. We have written a computer script that performs automatic data collection with immediate background subtraction. A computer-controlled detector positioning stage is used to precisely measure the microbeam peak dose and beam profile by translating the stage during data collection. We test the new generation nanoFOD system, with increased active scintillation volume, against the previous generation system. Both raw and processed data are time-stamped and recorded to enable future post-processing. Results: The real-time microbeam dosimetry system worked as expected. The new generation dosimeter has approximately double the active volume compared to the previous generation resulting in over 900% increase in signal. The active volume of the dosimeter still provided the spatial resolution that meets the Nyquist criterion for our microbeam widths. Conclusion: We have demonstrated that real-time dosimetry of MRT microbeams is feasible using a nanoscintillator fiber-optic detector with integrated positioning system.

60 APPLIED LIFE SCIENCES↗

Agricultural Baseline (BL0) scenario of the 2016 Billion-Ton Report

Scientific reason for data generation: to serve as the reference case for the BT16 volume 1 agricultural scenarios. The agricultural baseline runs from 2015 through 2040; a starting year of 2014 is used. Date the data set was last modified: 02/12/2016 How each parameter was produced (methods), format, and relationship to other data in the data set: simulation was developed without offering a farmgate price to energy crops or residues (i.e., building on both the USDA 2015 baseline and the agricultural census data (USDA NASS 2014). Data generated are .txt output files by year, simulation identifier, county code (1-3109). Instruments used: POLYSYS (version POLYS2015_V10_alt_JAN22B) supplied by the University of Tennessee APAC The quality assurance and quality control that have been applied: • Check for negative planted area, harvested area, production, yield and cost values. • Check if harvested area exceeds planted area for annuals. • Check FIPS codes.

09 BIOMASS FUELS↗

Agricultural Baseline (BL0) scenario

Scientific reason for data generation: to serve as the reference case for the BT16 volume 1 agricultural scenarios. The agricultural baseline runs from 2015 through 2040; a starting year of 2014 is used. Date the data set was last modified: 02/12/2016 How each parameter was produced (methods), format, and relationship to other data in the data set: simulation was developed without offering a farmgate price to energy crops or residues (i.e., building on both the USDA 2015 baseline and the agricultural census data (USDA NASS 2014). Data generated are .txt output files by year, simulation identifier, county code (1-3109). Instruments used: POLYSYS (version POLYS2015_V10_alt_JAN22B) supplied by the University of Tennessee APAC The quality assurance and quality control that have been applied: • Check for negative planted area, harvested area, production, yield and cost values. • Check if harvested area exceeds planted area for annuals. • Check FIPS codes.

09 BIOMASS FUELS↗

Treatment Planning and Delivery of External Beam Radiotherapy for Pediatric Sarcoma: The St. Jude Children's Research Hospital Experience

Purpose: To describe and review the radiotherapy (RT) treatment planning and delivery techniques used for pediatric sarcoma patients at St. Jude Children's Research Hospital. The treatment characteristics serve as a baseline for future comparison with developing treatment modalities. Patients and Methods: Since January 2003, we have prospectively treated pediatric and young-adult patients with soft-tissue and bone sarcomas on an institutional Phase II protocol evaluating local control and RT-related treatment effects from external-beam RT (conformal or intensity-modulated RT; 83.4%), low-dose-rate brachytherapy (8.3%), or both (8.3%). Here we describe the treatment dosimetry and delivery parameters of the initial 72 patients (median, 11.6 years; range, 1.4-21.6 years). Results: Cumulative doses from all RT modalities ranged from 41.4 to 70.2 Gy (median, 50.4 Gy). Median D{sub 95} and V{sub 95} of the planning target volume of external-beam RT plans were, respectively, 93.4% of the prescribed dose and 94.6% of the target volume for the primary phase and 97.8% and 99.2% for the cone-down/boost phase. The dose-volume histogram statistics for 27 critical organs varied greatly. The spinal cord in 13 of 36 patients received dose >45 Gy (up to 52 Gy in 1 cc) because of tumor proximity. Conclusions: Planning and delivery of complex multifield external beam RT is feasible in pediatric patients with sarcomas. Improvements on conformity and dose gradients are still desired in many cases with sensitive adjacent critical structures. Long-term follow-up will determine the risk of local failure and the benefit of normal tissue avoidance for this population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Outcome of Dose-Escalated Image-Guided Radiotherapy for Spinal Metastases

Purpose: To evaluate the outcomes after dose-escalated radiotherapy (RT) for spinal metastases and paraspinal tumors. Methods and Materials: A total of 14 patients, 12 with spinal metastases and a long life expectancy and 2 with paraspinal tumors, were treated for 16 lesions with intensity-modulated, image-guided RT. A median biologic effective dose of 74 Gy{sub 10} (range, 55-86) in a median of 20 fractions (range, 3-34) was prescribed to the target volume. The spinal canal was treated to 40 Gy in 20 fractions using a second intensity-modulated RT dose level in the case of epidural involvement. Results: After median follow-up of 17 months, one local recurrence was observed, for an actuarial local control rate of 88% after 2 years. Local control was associated with rapid and long-term pain relief. Of 11 patients treated for a solitary spinal metastasis, 6 developed systemic disease progression. The actuarial overall survival rate for metastatic patients was 85% and 63% after 1 and 2 years, respectively. Acute Grade 2-3 skin toxicity was seen in 2 patients with no late toxicity greater than Grade 2. No radiation-induced myelopathy was observed. Conclusion: Dose-escalated irradiation of spinal metastases was safe and resulted in excellent local control. Oligometastatic patients with a long life expectancy and epidural involvement are considered to benefit the most from fractionated RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗