Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Actinic EUV mask inspection beyond 0.25 NA

Operating at EUV wavelengths, the SEMATECH Berkeley Actinic Inspection Tool (AIT) is a zoneplate microscope that provides high quality aerial image measurements in routine operations for SEMATECH member companies. We have upgraded the optical performance of the AIT to provide multiple image magnifications, and several inspection NA values up to 0.35 NA equivalent (0.0875 mask-side). We report on the improved imaging capabilities including resolution below 100-nm on the mask side (25 nm, 4x wafer equivalent). EUV reticles are intricate optical systems made from of several materials with wavelength-specific optical properties. The combined interactions of the substrate, multilayer-stack, buffer layer and absorber layer produce a reflected EUV optical field that is challenging to model accurately, and difficult to fully assess without actinic at-wavelength inspection. Understanding the aerial image from lithographic printing alone is complicated by photoresist properties. The AIT is now used to investigate mask issues such as amplitude and phase defect printability, pattern repair techniques, contamination, inspection damage, and mask architecture. The AIT has a 6{sup o} illumination angle, and high-resolution exposure times are typically 20 seconds per image. The AIT operates semi-automatically capturing through-focus imaging series with step sizes as small as 0.1 {micro}m (0.5-0.8 {micro}m are typical), and a step resolution of 0.05 {micro}m. We believe it is the most advanced EUV mask inspection tool in operation today. In the AIT, an EUV image of the mask is projected by a zoneplate lens with high magnification (680-910x) onto a CCD camera. The CCD over-samples the image, providing equivalent pixel sizes down to 15 nm in mask coordinates-several image pixels per resolution element. The original AIT zoneplate specifications were designed to emulate the resolution of a 0.25-NA 4x stepper, and thorough benchmarking analysis of the aberrations, flare, contrast-transfer function, and coherence was published in 2007 [1] (see Fig 1). Recent upgrades have also included changes to improve the illumination uniformity and increase the partial coherence {sigma} value. Five different zoneplate lenses are installed side-by-side to enable the AIT to emulate various stepper optical properties (see Fig. 2).

36 MATERIALS SCIENCE↗

Visualizing the Internal Nanocrystallinity of Calcite Due to Nonclassical Crystallization by 3D Coherent X–Ray Diffraction Imaging

The internal crystallinity of calcite is investigated for samples synthesized using two approaches: precipitation from solution and the ammonium carbonate diffusion method. Scanning electron microscopy (SEM) analyses reveal that the calcite products precipitated using both approaches have a well–defined rhombohedron shape, consistent with the euhedral crystal habit of the mineral. The internal structure of these calcite crystals is characterized using Bragg coherent diffraction imaging (BCDI) to determine the 3D electron density and the atomic displacement field. BCDI reconstructions for crystals synthesized using the ammonium carbonate diffusion approach have the expected euhedral shape, with internal strain fields and few internal defects. In contrast, the crystals synthesized by precipitation from solution have very complex external shapes and defective internal structures, presenting null electron density regions and pronounced displacement field distributions. These heterogeneities are interpreted as multiple crystalline domains, created by a nonclassical crystallization mechanism, where smaller nanoparticles coalescence into the final euhedral particles. The combined use of SEM, X–ray diffraction (XRD), and BCDI allows for structurally differentiating calcite crystals grown with different approaches, opening new opportunities to understand how grain boundaries and internal defects alter calcite reactivity.

36 MATERIALS SCIENCE↗

Uncovering the Materials Paradigm at the Nanoscale: The Role of Next Generation Imaging and Characterization

The behavior of many energy materials and devices is very often limited by inhomogeneously distributed nanoscale defects. This is the case throughout the entire lifecycle of the solar cell, from the distribution of elements and defects during solar cell growth as well as the charge-collection and recombination during operation, to degradation and failure mechanisms due to impurity diffusion, crack formation, and irradiation- and heat-induced cell damage. This has been known for a while in the field of crystalline silicon, but inhomogeneities are far more abundant and smaller in scale for the case of polycrystalline materials. We showed that the high penetration of hard X-rays combined with the high sensitivity to elemental distribution, structure, and spatial resolution offers a unique avenue for highly correlative studies at the nanoscale. We presented results on CdTe and Cu(In,Ga)Se2 where carrier collection is directly correlated to the compositional and structural properties of the material under a large variety of synthesis and operating conditions. The segregation of copper at the grain boundaries of both solar absorbers was discussed in detail as well as the defects impact to carrier collection efficiency. Furthermore, the kinetics of copper segregation during growth and processing was presented and discussed.

Bertoni, Mariana↗

Development of scintillation materials for medical imaging and other applications

Scintillation materials that produce pulses of visible light in response to the absorption of energetic photons, neutrons, and charged particles, are widely used in various applications that require the detection of radiation. The discovery and development of new scintillators has accelerated in recent years, due in large part to their importance in medical imaging as well as in security and high energy physics applications. Better understanding of fundamental scintillation mechanisms as well as the roles played by defects and impurities have aided the development of new high performance scintillators for both gamma-ray and neutron detection. Although single crystals continue to dominate gamma-ray based imaging techniques, composite materials and transparent optical ceramics potentially offer advantages in terms of both synthesis processes and scintillation performance. A number of promising scintillator candidates have been identified during the last few years, and several are currently being actively developed for commercial production. Purification and control of raw materials and cost effective crystal growth processes can present significant challenges to the development of practical new scintillation materials.

36 MATERIALS SCIENCE↗

Role of Defects in Swelling and Creep of Irradiated SiC

Silicon carbide is a promising cladding material because of its high strength and relatively good corrosion resistance. However, SiC is brittle and therefore SiC-based components need to be carefully designed to avoid cracking and failure by fracture. In design of SiC-based composites for nuclear reactor applications it is essential to take into account how mechanical properties are affected by radiation and temperature, or in other words, what strains and stresses develop in this material due to environmental conditions. While thermal strains in SiC can be predicted using classical theories, radiation-induced strains are much less understood. In particular, it is critical to correctly account for radiation swelling and radiation creep, which contribute significantly to dimensional instability of SiC under radiation. Swelling typically increases logarithmically with radiation dose and saturates at relatively low doses (damage levels of a few dpa). Consequently, swelling-induced stresses are likely to develop within a few months of operation of a reactor. Radiation-induced volume swelling in SiC can be as high as 2%, which is significantly higher than the cracking strain of 0.1% in SiC. Swelling-induced strains will lead to enormous stresses and fracture, unless these stresses can be relaxed via some other mechanism. An effective way to achieve stress relaxation is via radiation creep. Although it has been hypothesized that both radiation swelling and radiation creep are driven by formation of defect clusters, existing models for swelling and creep in SiC are limited by the lack of understanding of specific defects that form due to radiation in the range of temperatures relevant to fuel cladding in light water reactors (LWRs) (<1000°C). For example, defects that can be detected with traditional transmission electron microscopy (TEM) techniques account only for 10-45% of the swelling measured in irradiated SiC. Here, we have undertaken an integrated experimental and modeling effort to discover the previously invisible defects in irradiated SiC and to determine the contributions of these defects to radiation swelling. Knowledge of the most stable defect structures and the rate controlling processes during defect evolution is essential for development of predictive models for swelling and creep as a function of temperature and radiation dose. This research has been enabled by state-of-the-art imaging techniques, such as the aberration corrected scanning transmission electron microscopy (STEM) (FEI TITAN) closely coupled with multi-scale models of stable defect clusters and their evolution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-speed synchrotron X-ray imaging of directed energy deposition of titanium: effects of processing parameters on the formation of entrapped-gas pores

Laser based directed energy deposition (DED) is a competitive method for repairing and remanufacturing metallic parts used in numerous industries including aerospace and biomedical. However, the numerous dynamic phenomena associated with the DED process often result in defects such as entrapped-gas pores, lack of fusion, and undesirable anisotropic properties. The entrapped-gas pore, being one of the most common issues, not only influences melt-pool dynamics but also reduces the fabrication quality and mechanical properties of parts fabricated by the DED process. To reduce and further understand this issue, the real-time observation of the pore formation process needs to be studied first. To directly observe the phenomena in the melt pool, high-speed techniques are needed because rapid solidification leads to rapid pore formation and movement. In-situ high-speed X-ray has been proven to be an effective method in investigating the melt pool dynamics and pore formation mechanisms in the laser powder bed fusion process, in which the fabrication process is quite different from that in DED. Here, the high-speed X-ray method is extended to study the formation of entrapped-gas pores. The real-time formation and quantitative analysis of pores under each set of processing parameters (particle velocity, laser power, and spot welding dwelling time of stationary laser) in the DED process are investigated. We found that the DED with a higher particle velocity (3.19 m/s) produced a smaller average pore size of 27.8 µm and a lower pore area fraction of 0.52%. The DED under lower laser power (156 W) generated a smaller average pore size of 20.3 µm and a lower pore area fraction of 1.94%. The shorter dwelling time (10 ms) benefited the decrease of both average pore size and pore area fraction.

Defect↗

Scanning thermo-ionic microscopy for probing local electrochemistry at the nanoscale

Conventional electrochemical characterization techniques based on voltage and current measurements only probe faradaic and capacitive rates in aggregate. In this work we develop a scanning thermo-ionic microscopy (STIM) to probe local electrochemistry at the nanoscale, based on imaging of Vegard strain induced by thermal oscillation. It is demonstrated from both theoretical analysis and experimental validation that the second harmonic response of thermally induced cantilever vibration, associated with thermal expansion, is present in all solids, whereas the fourth harmonic response, caused by local transport of mobile species, is only present in ionic materials. The origin of STIM response is further confirmed by its reduced amplitude with respect to increased contact force, due to the coupling of stress to concentration of ionic species and/or electronic defects. The technique has been applied to probe Sm-doped Ceria and LiFePO{sub 4}, both of which exhibit higher concentrations of mobile species near grain boundaries. The STIM gives us a powerful method to study local electrochemistry with high sensitivity and spatial resolution for a wide range of ionic systems, as well as ability to map local thermomechanical response.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanoimaging of Electronic Heterogeneity in Bi 2 Se 3 and Sb 2 Te 3 Nanocrystals

Topological insulators (TIs) are quantum materials with topologically protected surface states surrounding an insulating bulk. However, defect-induced bulk conduction often dominates transport properties in most TI materials, obscuring the Dirac surface states. In order to realize intrinsic topological insulating properties, it is thus of great significance to identify the spatial distribution of defects, understand their formation mechanism, and finally control or eliminate their influence. For this study, the electronic heterogeneity in polyol-synthesized Bi 2 Se 3 and chemical vapor deposition-grown Sb 2 Te 3 nanocrystals is systematically investigated by multimodal atomic-to-mesoscale resolution imaging. In particular, by combining the Drude response sensitivity of infrared scattering-type scanning near-field optical microscopy with the work-function specificity of mirror electron microscopy, characteristic mesoscopic patterns are identified, which are related to carrier concentration modulation originating from the formation of defects during the crystal growth process. This correlative imaging and modeling approach thus provides the desired guidance for optimization of growth parameters, crucial for preparing TI nanomaterials to display their intrinsic exotic Dirac properties.

43 PARTICLE ACCELERATORS↗

Phenethylammonium Functionalization Enhances Near-Surface Carrier Diffusion in Hybrid Perovskites

Understanding semiconductor surface properties and manipulating them chemically are critical for improving their performance in optoelectronic devices. Hybrid halide perovskites have emerged as an exciting class of highly efficient solar materials; however, their device performance could be limited by undesirable surface properties that impede carrier transport and induce recombination. Here we show that surface functionalization of methylammonium lead iodide (MAPbI 3 ) perovskite with phenethylammonium iodide (PEAI), a commonly employed spacer cation in two-dimensional perovskites, can enhance carrier diffusion in the near-surface regions and reduce defect density by more than one order of magnitude. Using transient transmission and reflection microscopy, we selectively imaged the transport of the carriers near the (001) surface and the bulk carriers in single-crystal MAPbI 3 microplates. The surface functionalization increases the diffusion coefficient of the carriers in a 40-nm subsurface region from ~ 0.6 cm 2 s -1 to ~ 1 cm 2 s -1 , similar to the value for bulk carriers. These results suggest the PEA ligands are effective in suppressing surface defect and phonon scattering and shed light on the mechanisms for enhancing photophysical properties and improving solar cell efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Harmonic analysis for the characterization and correction of geometric distortion in MRI

Purpose: Magnetic resonance imaging (MRI) is gaining widespread use in radiation therapy planning, patient setup verification, and real-time guidance of radiation delivery. Successful implementation of these technologies relies on the development of simple and efficient methods to characterize and monitor the geometric distortions arising due to system imperfections and gradient nonlinearities. To this end, the authors present the theory and validation of a novel harmonic approach to the quantification of system-related distortions in MRI. Methods: The theory of spatial encoding in MRI is applied to demonstrate that the 3D distortion vector field (DVF) is given by the solution of a second-order boundary value problem (BVP). This BVP is comprised of Laplace’s equation and a limited measurement of the distortion on the boundary of a specified region of interest (ROI). An analytical series expansion solving this BVP within a spherical ROI is obtained, and a statistical uncertainty analysis is performed to determine how random errors in the boundary measurements propagate to the ROI interior. This series expansion is then evaluated to obtain volumetric DVF mappings that are compared to reference data obtained on a 3 T full-body scanner. This validation is performed within two spheres of 20 cm diameter (one centered at the scanner origin and the other offset +3 cm along each of the transverse directions). Initially, a high-order mapping requiring measurements at 5810 boundary points is used. Then, after exploring the impact of the boundary sampling density and the effect of series truncation, a reduced-order mapping requiring measurements at 302 boundary points is evaluated. Results: The volumetric DVF mappings obtained from the harmonic analysis are in good agreement with the reference data. Following distortion correction using the high-order mapping, the authors estimate a reduction in the mean distortion magnitude from 0.86 to 0.42 mm and from 0.93 to 0.39 mm within the central and offset ROIs, respectively. In addition, the fraction of points with a distortion magnitude greater than 1 mm is reduced from 35.6% to 2.8% and from 40.4% to 1.5%, respectively. Similarly, following correction using the reduced-order mapping, the mean distortion magnitude reduces to 0.45–0.42 mm within the central and offset ROIs, and the fraction of points with a distortion magnitude greater than 1 mm is reduced to 2.8% and 1.5%, respectively. Conclusions: A novel harmonic approach to the characterization of system-related distortions in MRI is presented. This method permits a complete and accurate mapping of the DVF within a specified ROI using a limited measurement of the distortion on the ROI boundary. This technique eliminates the requirement to exhaustively sample the DVF at a dense 3D array of points, thereby permitting the design of simple, inexpensive phantoms that may incorporate additional modules for auxiliary quality assurance objectives.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Facet Dependent Disorder in the Pristine High Voltage Lithium-Manganese-Rich Cathode Material

Defects and surface reconstructions are thought to be crucial for the long term stability of high-voltage lithium-manganese-rich cathodes. Unfortunately, many of these defects arise only after electrochemical cycling which occur under harsh conditions making it difficult to fully comprehend the role they play in degrading material performance. Recently, it has been observed that defects are present even in the pristine material. This study, therefore, focuses on examining the nature of the disorder observed in pristine Li$_{1.2}$Ni$_{0.175}$Mn$_{0.525}$Co$_{0.1}$O$_2$ (LNMCO) particles. Using atomic resolution Z-contrast imaging and electron energy-loss spectroscopy measurements we show that there are indeed a significant amount of anti-site defects present in this material; with transition metals substituting on Li metal sites. Furthermore, we find a strong tendency of segregation of these types of defects towards open facets (surfaces perpendicular to the layered arrangement of atoms), rather than closed facets (surfaces parallel to the layered arrangement of atoms). First principles calculations identify anti-site defect pairs of Ni swapping with Li ions as the predominant defect in the material. Furthermore, energetically favorable swapping of Ni on the Mn sites were observed to lead to Mn depletion at open facets. Relatively, low Ni migration barriers also support the notion that Ni are the predominant cause of disorder. These insights suggests that certain facets of the LNMCO particles may be more useful for inhibiting surface reconstruction and improving the stability of these materials through careful consideration of the exposed surface.

25 ENERGY STORAGE↗

Application of Different X-ray Techniques to Improve In-Service Carbon Fiber Reinforced Rope Inspection

Carbon fiber reinforced polymer ropes are gaining in significance in the fields of civil engineering and hoisting applications. Thus, methods of non-destructive testing (NDT) need to be developed and evaluated with respect to new challenges and types of defects. Particularly important is the development of in-service testing solutions which allow the integration in global online monitoring systems. Conventional methods like electrical resistivity or strain measurements using optical fibers are already in use. This study investigates the possibility of using various X-ray techniques to increase the reliability and significance of NDT and their applicability to in-service testing. Conventional film radiography is the most common technique; however, even after image enhancement of the digitized film, this technique lacks contrast sensitivity and dynamic range compared to digital detector array (DDA) radiography. The DDA radiography is a highly sensitive method; yet, the limitation is that it delivers 2D images of 3D objects. By the use of co-planar translational laminography the detectability of planar defects is superior to 2D methods due to multiple projection angles. Apart from this, it can be used on-site due to a rather simple setup and robust equipment. In this work two photon counting detectors (PCD) with different sensor materials (Si and CdTe) were used. The results show that the resolution and defect recognition is lower in case of DDA radiography and laminography using PCDs compared to high-resolution computed tomography. However, the DDA radiography and laminography are sensitive enough to both fiber breakage and delaminations and can be significantly advantageous in terms of measurement time and adaptability for on-site monitoring.

42 ENGINEERING↗

Understanding kinetics of defect annihilation in chemoepitaxy-directed self-assembly.

Directed self-assembly (DSA) of block copolymers (BCP) has attracted considerable interest from the semiconductor industry because it can achieve semiconductor-relevant structures with a relatively simple process and low cost. However, the self-assembling structures can become kinetically trapped into defective states, which greatly impedes the implementation of DSA in high-volume manufacturing. Understanding the kinetics of defect annihilation is crucial to optimizing the process and eventually eliminating defects in DSA. Such kinetic experiments, however, are not commonly available in academic laboratories. To address this challenge, we perform a kinetic study of chemoepitaxy DSA in a 300 mm wafer fab, where the complete defectivity information at various annealing conditions can be readily captured. Through extensive statistical analysis, we reveal the statistical model of defect annihilation in DSA for the first time. The annihilation kinetics can be well described by a power law model, indicating that all dislocations can be removed by sufficiently long annealing time. We further develop image analysis algorithms to analyze the distribution of dislocation size and configurations and discover that the distribution stays relatively constant over time. The defect distribution is determined by the role of the guiding stripe, which is found to stabilize the defects. Although this study is based on polystyrene-b-poly(methyl methacrylate) (PS-b-PMMA), we anticipate that these findings can be readily applied to other BCP platforms as well.

block copolymer↗

Transmission electron microscopy study of the MgS–Tm{sub 2}S{sub 3} system

This work presents the structural–microstructural characterization of the NaCl-derivative MgS–Tm{sub 2}S{sub 3} system, which can be formulated by the expression Mg{sub (1−x)}Tm{sub (2/3)x}□{sub (1/3)x}S (□→cation vacancy). Transmission electron microscopy observations show the transition between NaCl-type and spinel-type structures when 0 ≤x≤ 0.75. The increase of Tm content in the solid solution provokes the increase of the spinel-type phase proportion, which intergrows with the NaCl-type crystals. When x≥0.75, some phases derived from NaCl-type structure through the chemical twinning at the unit cell level crystallographic operation are observed, such as CT-MgTm{sub 2}S{sub 4} and CT-MgTm{sub 4}S{sub 7}. The existence and nature of the extended defects observed along the c direction of these structures are characterized by means of Scanning-Transmission electron microscopy high-angle dark field imaging, which allows observing the presence of quasi ordered crystals with new possible complex stoichiometries at atomic resolution. - Graphical abstract: HAADF-STEM image of a disordered CT-MgYb{sub 2}S{sub 4} crystal. The disordered twin-slab sequences are marked by arrows. - Highlights: • Structural evolution of the Mg{sub (1−x)}Tm{sub (2/3)x}□{sub (1/3)x}S system was characterized by means of TEM. • The increase in Tm content provokes the transition from NaCl to spinel-type structure up to x=0.75. • Chemical twinned phases CT-MgTm{sub 2}S{sub 4} and CT-MgTm{sub 4}S{sub 7} are observed at high Tm contents. • Extended defects in CT-crystals are characterized with atomic resolution STEM-HAADF images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strain–Activated Stimulated Emission from Multilayer MoSe 2 in a Narrow Operation Window

Herein, photoluminescence (PL) and fluorescence lifetime imaging (FLIM) in multilayer MoSe 2 are studied. Strain-activated stimulated emission via defect levels in multilayer MoSe 2 under laser excitation is observed, for the first time in defects of transition metal dichalcogenides. The stimulated emission is indicated by a threshold behavior of PL emission intensity with respect to laser intensity, strong polarization effects, achieved population inversion with a difference in lifetimes of two competing excited states, and localization of the stimulated emission zone as observed in FLIM. Here, the presented results not only demonstrate strain-activated stimulated emission and highlight the necessity of strain engineering in tailoring 2D layered materials for optoelectronic applications, but also shed light on the design of stimulated emission in transition metal dichalcogenide's defects to tailor for potential single-photon emission behavior.

enhanced emission↗