Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Electrical and Spectroscopic Diagnostics as Real‐Time Metallization Indicators During Hydrogen Plasma Smelting Reduction

This study investigates the hydrogen (H 2 ) plasma reduction process of direct-reduced-iron-grade hematite ore at different arc currents (100–200 A) in an Ar–5% H 2 atmosphere at 0.9 bar. Iron ore samples (10 g) were exposed to a plasma arc, and the reduction/metallization kinetics were analyzed over fixed time intervals. Electrical diagnostics revealed that the arc voltage exhibited takeover-mode oscillations which were suppressed at higher currents due to stronger electromagnetic coupling. The voltage dropped significantly as metallization approached ∼95%, linked to increased electrical conductivity of the metallic iron (Fe) in the ore as well as Fe evaporation into the arc, lowering the arc resistance. A simplified Elenbaas–Heller model supported this explanation and confirmed that Fe vapor concentration enhances plasma conductivity. Optical emission spectroscopy focused on the plasma–metal interface revealed the plasma's optically thick nature, as the primary Fe I 526.95 nm line experienced self-absorption. However, weaker Fe I lines (404.58, 438.35 nm) normalized to Ar I 696.5 nm provided a reliable proxy for metallization. These diagnostics, electrical and spectroscopic, effectively track metallization in real-time during H 2 plasma smelting reduction.

08 HYDROGEN↗

Laser machined plastic laminates. Towards portable diagnostic devices for use in low resource environments

Despite significant progress in development of bioanalytical devices cost, complexity, access to reagents and lack of infrastructure have prevented use of these technologies in resource-limited regions. To provide a sustainable tool in the global effort to combat infectious diseases the diagnostic device must be low cost, simple to operate and read, robust, and have sensitivity and specificity comparable to laboratory analysis. Thus, in this mini-review we describe recent work using laser machined plastic laminates to produce diagnostic devices that are capable of a wide variety of bioanalytical measurements and show great promise towards future use in low-resource environments.

47 OTHER INSTRUMENTATION↗

Optical Diagnostics of Discharges in and in Contact With Liquids

Discharges in liquids have been the subject of intensive investigations for a broad range of applications and involve highly coupled and complex phenomena with timescales ranging from picoseconds to seconds and length scales from micrometers to centimeters. This review focuses on some of the challenges in optical diagnostics of discharges in and in contact with liquids; this includes the interpretation of optical emission spectra, the inherently stochastic nature of many discharge phenomena including the initial stages of plasma ignition, and the large gradients in species and plasma properties interfacing with a dynamic liquid interface. We report recent notable advances, controversies in interpretations of diagnostics, and remaining opportunities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prenatal planning of placenta previa: diagnostic accuracy of a novel MRI-based prediction model for placenta accreta spectrum (PAS) and clinical outcome

Purpose: To investigate the diagnostic accuracy of MRI for placenta accreta spectrum (PAS) and clinical outcome prediction in women with placenta previa, using a novel MRI-based predictive model. Methods: Thirty-eight placental MRI exams performed on a 1.5T scanner were retrospectively reviewed by two radiologists in consensus. The presence of T2 dark bands, myometrial thinning, abnormal vascularity, uterine bulging, placental heterogeneity, placental protrusion sign, placental recess, and percretism signs was scored using a 5-point scale. Pathology and clinical intrapartum findings were the standard of reference for PAS, while intrapartum/peripartum bleeding and emergency hysterectomy defined the clinical outcome. Receiver-operating characteristic (ROC) analysis and discriminant function analysis were performed to test the predictive power of MRI findings for both PAS and clinical outcome prediction. Results: Abnormal vascularity and percretism signs were the two most predictive MRI features of PAS. The area under the curve (AUC) of the predictive function was 0.833 (cutoff 0.39, 67% sensitivity, 100% specificity, p = 0.001). Percretism signs and myometrial thinning were the two most predictive MRI features of poor outcome. AUC of the predictive function was 0.971 (cutoff − 0.55, 100% sensitivity, 77% specificity, p < 0.001). Conclusion: The diagnostic accuracy of MRI, especially considering the combination of the most predictive MRI findings, is higher when the target of the prediction is the clinical outcome rather than the PAS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) versus endoscopic retrograde cholangiopancreatography (ERCP) in the pediatric population: a clinical effectiveness study

Purpose: To determine the diagnostic performance of magnetic resonance cholangiopancreatography (MRCP) for detecting biliary and pancreatic abnormalities in a pediatric population, using endoscopic retrograde cholangiopancreatography (ERCP) as the reference standard. Materials and methods: Institutional review board approval with a waiver of informed consent was obtained for this retrospective investigation. Records from the Cincinnati Children’s Hospital Medical Center, Division of Gastroenterology and Department of Radiology were used to identify patients aged ≤ 18 years who had undergone both ERCP and MRCP within a 4-week interval between January 2013 and May 2017. Biliary and pancreatic duct findings were documented for each modality to determine the diagnostic performance of MRCP (with 95% confidence intervals), using ERCP as the reference standard. Results: 54 patients met inclusion criteria. Mean patient age at time of ERCP was 10.4 ± 4.9 years, and 25 (46%) were male. Mean interval between ERCP and MRCP was 11.2 ± 9.7 days. For detection of any abnormality (n = 99 ERCP findings), MRCP had a sensitivity of 76.8% (67.5–84.0%) and a positive predictive value (PPV) of 81.7% (72.7–88.3%). MRCP was 75.7% (59.9–86.6%) sensitive, with a PPV of 84.9% (69.1–93.4%) for biliary findings (n = 37) and 73.5% (59.7–83.8%) sensitive, with a PPV of 78.3% (64.4–87.7%) for pancreatic findings (n = 49). For pancreatobiliary abnormalities (n = 13), MRCP had a sensitivity of 92.3% (66.7–99.6%) and a PPV of 85.7% (60.1–97.5%). Conclusion: In clinical practice, MRCP is moderately sensitive for biliary and pancreatic abnormalities, with false-negative and false-positive examinations being relatively common.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic accuracy of acoustic radiation force impulse elastography (ARFI) in comparison to other non-invasive modalities in staging of liver fibrosis in chronic HCV patients: single-center experience

Purpose: To evaluate the reliability of ARFI elastography for liver fibrosis staging and compare it to other non-invasive assessment of hepatic fibrosis (FIB-4 and APRI) in chronic HCV (CHC) patients. Methods: A single-center, prospective study included 2103 CHC patients. Liver stiffness (LS) was evaluated by TE and ARFI elastography. FIB-4 and APRI were calculated. The area under the receiver-operating characteristic curve (AUROCs) was used to assess the diagnostic performance of ARFI elastography for staging of liver fibrosis using TE as a reference standard. Results: The best cut off values of ARFI elastography for diagnosis of ≥ F2, ≥ F3and F4 were 1.36 m/s, 1.45 m/s, and 1.7 m/s with AUROCs of 0.89, 0.94 and 0.95, respectively. ARFI elastography cut offs are lower in patients with normal ALT level compared to those with ALT level (1.1–< 3 ULN) and those with ALT level ≥ 3ULN (1.35 m/s vs 1.39 m/s vs 1.54 for F ≥ 2, 1.44 m/s vs 1.58 m/s vs 1.6 m/s for F3, 1.69 m/s, 1.84 m/s, 1.86 m/s for F4). FIB-4 (0.82–0.86) and APRI (0.78–0.82) yielded lower AUC in prediction of significant fibrosis and cirrhosis than ARFI elastography (0.89–0.95). Conclusion: ARFI elastography is a reliable method for non-invasive staging of liver fibrosis in CHC patients when compared to TE with a good diagnostic performance comparable to FIB-4 and APRI scores for the prediction of significant fibrosis and cirrhosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multipath Curved Planar Reformations of Peripheral CT Angiography: Diagnostic Accuracy and Time Efficiency

ObjectivesTo compare diagnostic performance and time efficiency between 3D multipath curved planar reformations (mpCPRs) and axial images of CT angiography for the pre-interventional assessment of peripheral arterial disease (PAD), with digital subtraction angiography as the standard of reference.MethodsForty patients (10 females, mean age 72 years), referred to CTA prior to endovascular treatment of PAD, were prospectively included and underwent peripheral CT angiography. A semiautomated toolbox was used to render mpCPRs. Twenty-one arterial segments were defined in each leg; for each segment, the presence of stenosis > 70% was assessed on mpCPRs and axial images by two readers, independently, with digital subtraction angiography as gold standard.ResultsBoth readers reached lower sensitivity (Reader 1: 91 vs. 94%, p = 0.08; Reader 2: 89 vs. 93%, p = 0.03) but significantly higher specificity (Reader 1: 94 vs. 89%, p < 0.01; Reader 2: 96 vs. 95%, p = 0.01) with mpCPRs than with axial images. Reader 1 achieved significantly higher accuracy with mpCPRs (93 vs. 91%, p = 0.02), and Reader 2 had similar overall accuracy in both evaluations (94 vs. 94%, p = 0.96). Both readers read mpCPRs significantly faster than axial images (Reader 1: 5′45″ based on mpCPRs vs. 7′40″ based on axial images; Reader 2: 4′41″ based on mpCPRs vs. 6′57″ based on axial images; p < 0.01).ConclusionsmpCPRs are a promising 3D reformation technique that facilitates a fast assessment of PAD with high diagnostic accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated System of Diagnostic Monitoring at Bureya HPP Hydraulic Engineering Installations: a New Level of Safety

This article presents the design, hardware, and software solutions developed and placed in service for the automated system of diagnostic monitoring (ASDM) for hydraulic engineering installations at the Bureya HPP, and assuring a reliable process for monitoring hydraulic engineering installations. Project implementation represents a timely solution of problems addressed by the hydraulic engineering installation diagnostics section.

42 ENGINEERING↗

Identification of candidate diagnostic and prognostic biomarkers for human prostate cancer: RPL22L1 and RPS21

Prostate cancer (PCa) is one of the most common malignancies in men worldwide. This study was designed to investigate the potential of Ribosomal Protein L22-like1 (RPL22L1) and Ribosomal Protein S21 (RPS21) as diagnostic and prognostic biomarkers for PCa. First, RPL22L1 and RPS21 were screened as the key molecular of PCa by bioinformatics analysis. Subsequently, the prostate tissue samples were stained for antibodies against RPL22L1 and RPS21. The unbiased signal quantification was performed by ImageJ software, and the results showed that the expression of RPL22L1 and RPS21 exhibited significant differences between the PCa tissues and the normal prostate tissues. Receiver-operating characteristics (ROC) curves were prepared, and then the area under the curve (AUC) values of RPL22L1 and RPS21 were calculated as 0.798 and 0.768, and the likelihood ratio (LR) values of RPL22L1 and RPS21 were calculated as 2.86 and 2.53. These data implied that the over-expression of RPL22L1 and RPS21 is associated with the presence of PCa. The further analysis suggested that the expression of RPL22L1 and RPS21 were significantly higher in high Gleason grade than they were in low Gleason grade. In addition, in vitro studies were undertaken to evaluate the roles of RPL22L1 and RPS21 in PCa. The results revealed that these genes promote PCa cell proliferation, migration and invasion, and inhibit PCa cell apoptosis. Taken together, these data showed that RPL22L1 and RPS21 exhibited higher expression in human prostate cancer tissue, and involved in PCa cell proliferation and invasion. This research provided a novel insight into diagnostic and prognostic biomarkers for PCa.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic value of stress thallium-201/rest technetium-99m-sestamibi sequential dual isotope high-speed myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis

Background: The aim of this study was to determine the diagnostic accuracy of stress thallium-201/rest technetium-99m-sestamibi sequential dual-isotope high-speed myocardial perfusion imaging (DI-HS-MPI) against invasively determined fractional flow reserve (FFR). Methods: Fifty-four consecutive patients prospectively underwent DI-HS-MPI before invasive coronary angiography. Perfusion was scored visually by summed stress score on a patient and coronary territory basis. Significant coronary artery disease (CAD) was defined by the presence of ≥ 90% stenosis/occlusion or fractional flow reserve ≤ 0.80 for coronary stenosis ≥ 50%. Results: FFR was measured in 69 of 162 coronary vessels, with 1.28 ± 0.56 vessels assessed/patient. Sensitivity, specificity, and diagnostic accuracy of MPI for the detection of significant CAD were 92.8%, 69.2%, and 81.4%, on a patient basis, and 83.7%, 90.4%, and 88.8% by coronary territory. Conclusions: DI-HS-MPI accurately detects functionally significant CAD as defined by using FFR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple simultaneous faults’ impacts on air-conditioner behavior and performance of a charge diagnostic method

Although there have been several studies that have focused on the effects of faults on the performance and on the characteristic features that could be used to detect faults, almost none of the research has studied the effects of multiple simultaneous faults. Existing fault detection and diagnosis approaches that have been developed based on single faults may struggle with simultaneous faults. Here, this paper is part of a series that present a methodology and comprehensive measurement data from a battery of laboratory tests on an air-conditioner with combinations of common faults (refrigerant charge, evaporator airflow, non-condensable gas, and liquid line restrictions) imposed, to show how the indicator variables and overall performance are impacted. The system has a microtube condenser and a fixed-orifice (FXO) expansion device, which are found to affect the features’ fault sensitivity. This experiment is the first to test these combined faults in an FXO-equipped system, so comparisons are made to a previously studied thermostatic expansion valve-equipped system. Finally, a promising charge diagnostic technology is assessed, to see how it is impacted by other faults. The faults reduced capacity by up to 42%, and efficiency by up to 39%. The charge diagnostic performed well, even with multiple faults present.

42 ENGINEERING↗

Diagnostic health risk assessment of electronic waste on the general population in developing countries' scenarios

E-waste is the generic name for technological waste. Even though aspects related to e-waste environmental pollution and human exposure are known, scientific assessments are missing so far on the actual risks for health sustainability of the general population exposed to e-waste scenarios, such as illicit dumping, crude recycling and improper treatment and disposal. In fact, further to occupational and direct local exposure, e-waste scenarios may impact on the environment-to-food chain, thus eliciting a widespread and repeated exposure of the general population to mixtures of toxicants, mainly toxic chemical elements, polycyclic aromatic hydrocarbons and persistent organic pollutants. In the absence of any clear policy on e-waste flow management, the situation in the e-waste receiver countries may become quite scary; accordingly, here we address a diagnostic risk assessment of health issues potentially elicited by e-waste related mixtures of toxicants. Scientific evidence available so far (mainly from China) is discussed with special attention to the concept of health sustainability, i.e. the poor health burden heritage perpetuated through the mother-to-child dyad. Endocrine disruption and neurotoxicity are specifically considered as examples of main health burden issues relevant to perpetuation through life cycle and across generations; toxicological information are considered along with available data on environmental and food contamination and human internal exposure. The risk from exposure to e-waste related mixtures of toxicants of vulnerable subpopulation like breast-fed infants is given special attention. The diagnostic risk assessment demonstrates how e-waste exposure poses an actual public health emergency, as it may entrain significant health risks also for generations to come. Exposure scenarios as well as specific chemicals of major concern may vary in different contexts; for instance, only limited information is available on e-waste related exposures in a major site of e-waste dumping such as West Africa. Therefore, considerations are also given on data gaps possibly fitting a systematic risk assessment of the e-waste health impacts in different subscenarios as well as possible protective factors for exposed subpopulations.

54 ENVIRONMENTAL SCIENCES↗

Thermal Loads and Cooling Design for ITER in-Port Low Field Side Reflectometer Diagnostic System

The current design for the ITER Low Field Side Reflectometer (LFSR) diagnostic system contains six circular waveguides that function as both launch and receive antennas. The front end of LFSR system, interfacing with the plasma facing DFW and its supporting diagnostic shielding Modules (DSM), is integrated into Equatorial Port Plug 11(EPP#11). In-vessel LFSR configuration is mainly divided into two sections, i.e. Front Antenna Unit (FAU) and in-vessel Transmission Line (TL) components. During plasma normal operation, the 14 MeV neutrons from D-T fusion reactions penetrate into the port plug and LFSR components. Neutronics code ATTILA is used for assessing the volumetric heating of in-vessel components. The maximum normal heat load due to radiation and the charge exchange from plasma is 0.35 MW/m 2 , which has to be applied on those surfaces affected by a viewing factor consistent with the aperture surface position and orientation. The front antenna unit (FAU) needs the active cooling to handle the radiant and nuclear heating from the plasma. Due to the specific viewing aperture layout at the front-end of in-vessel LFSR, the cooling channel design is challenging. The thermal-hydraulic iterations are performed to achieve the desirable temperature distribution of the water cooled front antenna units. The progressive ratcheting effects of the FAU subjected to cyclic thermal loading are examined by the preliminary non-linear elastic-plastic analysis.

42 ENGINEERING↗

The JET upgraded toroidal Alfvén Eigenmode Diagnostic System

The Alfvén Eigenmode Active Diagnostic system (AEAD) has undergone a major upgrade and redesign to provide a state-of-the-art excitation and real-time detection system for JET. The new system consists of individual 4 kW amplifiers allowing for increased current, separate excitation and real time control of relative phasing between antenna currents. The amplifiers have a frequency range of 10–1000 kHz, divided into various frequency bands by external matching filters. Due to the varying transmission line impedance throughout the frequency range, the amplifiers were designed with a very high resilience to reflected power. The existing amplifier control electronics have been replaced with a digital control system incorporating a National Instruments platform and Field Programmable Gate Array (FPGA) modules for frequency, gain and phase control with a frequency and phase resolution of less than 1 kHz and 1 degree respectively. Complementing the digital control system is the Protection and Control System, which utilizes Field Programmable Analog Arrays (FPAAs) and an array of electronic devices to monitor and control the AEAD. New capabilities such as independent antenna current/phase control, allow for improved excitation control, better definition of antenna spectrum combined with enhanced system reliability. This paper will review the new AEAD system, its unique capabilities and improvements over the previous diagnostic system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical design and synthetic analysis of the electron cyclotron emission imaging diagnostic of HL-2M tokamak

The electron cyclotron emission imaging (ECEI) diagnostic is a powerful tool to study the MHD and turbulent transport in magnetically confined fusion plasmas. In this work, the optical system including the local oscillator (LO) coupling and radio frequency (RF) receiving optics, has been designed and analyzed for the HL-2M ECEI diagnostic. The LO optics can illuminate the antenna array and drive the mixer diode to work efficiently, with more than 36% of the beam intensity for the channels which probe the plasma edge relative to those of channels which probe the plasma core. The RF optics aims at guiding the plasma emission signal to the antenna array. To meet different physical requirements, three types of field of view have been achieved for the plasma imaging, with zoom factors of around 1, 1.5 and 2, respectively. The focal surfaces are almost flat, with a maximum off-mapping (defined as the radial distance between the beam waists of the lower-/uppermost antennas and electron cyclotron emission layer) less than 2.5 cm, which can match the electron cyclotron emission layer quite well and suppress the image distortion in the plasma edge region. Furthermore, the impact of possible vibrations and installation error on the focal plane has been evaluated. In addition, the predefined MHD and turbulence perturbations are well reproduced by combining the optical simulation results and synthetic ECEI modeling, which further verifies the good performance of the RF optics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A temperature profile diagnostic for radiation waves on OMEGA-60

Predicting and matching radiation wave propagation with computational models has proven difficult. Information provided by experiments studying radiation flow has been limited when only radiation breakout is measured. We have developed the COAX (co-axial) diagnostic platform to provide spatial temperature profiles of a radiation wave through low density foams as a more detailed constraint for simulations. COAX uses a standard, laser-driven OMEGA-60 halfraum to drive radiation down a titanium-laden silicon oxide foam. Point-projection X-ray absorption spectroscopy perpendicular to the radiation flow measures the spatial profile of titanium ionization. The spectroscopic measurement utilizes a broadband capsule backlighter. Imaging and streak spectroscopy are used to characterize the size and spectrum of this source. Radiography provides an additional constraint by capturing the developing shock as the radiation flow becomes subsonic. The DANTE diagnostic is used to measure the halfraum temperature. Here, we provide a spectroscopic analysis of COAX data to determine temperature, and we describe experimental sources of uncertainty. The temperature is obtained by comparison to multi-temperature synthetic spectra post-processed from radiation-hydrodynamics simulations. Quantitative comparison between data and synthetic spectra generated from temperature profiles at relevant simulation times enable determination of a peak temperature of 114 ± 8 eV at 265 ± 22.4 μm from the halfraum. This represents an improvement over the temperature uncertainties of previous radiation flow experiments. Further refinements to the spectroscopic analysis could achieve ±4 eV. The combination between space-resolved spectroscopy and radiography enables us to determine the distance from the halfraum of both the radiation front and the shock front at the time of measurement. For the example shown in this paper the radiation front position is 600–630 μm at 3.43 ± 0.16 ns and the shock front position is 633 μm at 3.3 ± 0.24 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Benchmarking optimization methods for materials research: Gradient descent and Bayesian optimization for lithium-ion battery aging diagnostics

Accurate and efficient parameter estimation is essential for battery diagnostics and aging analysis. Here, in this study, we compare two optimization-based approaches—gradient descent and Bayesian optimization—for extracting parameters from differential voltage analysis in lithium-ion batteries. While these techniques are widely used, their relative strengths and limitations for this application are not well understood. The study evaluates the trade-offs between these methods in terms of result quality, computational cost, and reliability within this specific application. The diagnostic results from our battery data suggest adopting gradient descent as an initial method for rapid and efficient analysis, while employing more stable optimization techniques, such as Bayesian optimization, as a verification step to mitigate potential instability. Comparing the two methods provides information on algorithmic choice, while inspiring further discussions on selecting appropriate techniques for specific research tasks.

Zhao, Ziqing [Boston Univ., MA (United States)] (O↗

Assessing FPAR Source and Parameter Optimization Scheme in Application of a Diagnostic Carbon Flux Model

The combination of satellite remote sensing and carbon cycle models provides an opportunity for regional to global scale monitoring of terrestrial gross primary production, ecosystem respiration, and net ecosystem production. FPAR (the fraction of photosynthetically active radiation absorbed by the plant canopy) is a critical input to diagnostic models, however little is known about the relative effectiveness of FPAR products from different satellite sensors nor about the sensitivity of flux estimates to different parameterization approaches. In this study, we used multiyear observations of carbon flux at four eddy covariance flux tower sites within the conifer biome to evaluate these factors. FPAR products from the MODIS and SeaWiFS sensors, and the effects of single site vs. cross-site parameter optimization were tested with the CFLUX model. The SeaWiFs FPAR product showed greater dynamic range across sites and resulted in slightly reduced flux estimation errors relative to the MODIS product when using cross-site optimization. With site-specific parameter optimization, the flux model was effective in capturing seasonal and interannual variation in the carbon fluxes at these sites. The cross-site prediction errors were lower when using parameters from a cross-site optimization compared to parameter sets from optimization at single sites. These results support the practice of multisite optimization within a biome for parameterization of diagnostic carbon flux models.

54 ENVIRONMENTAL SCIENCES↗