Search NASA⌕ Search

SEARCH · Search NASA

Results for “efficient envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 883 records · Page 49

Characterization of a 100-kW Class Nested-Channel Hall Thruster

The next generation of electric propulsion consists of systems in excess of 300 kW of power. These systems enable a wide variety of missions, including crewed missions to near-Earth asteroids and Mars. Hall thrusters are a particularly attractive technology for these missions, but development and demonstration of 100-kW class devices has been limited to date. Here, a 100-kW class three-channel nested Hall thruster called the X3 was operated up to 102 kW total discharge power. The three channels of the X3 can be operated in any combination, providing seven unique configurations and a total throttling envelope of 2-200 kW. Previous testing of the X3 was limited to 30 kW and found that it was not providing state-of-the-art performance.Two low-power test campaigns were completed at the University of Michigan which identified potential mechanisms for this under-performance. Improvements to the thruster were made before a high-power performance characterization at NASA Glenn Research Center. There, the X3 was fired on xenon propellant from 5-102 kW total power. The thruster demonstrated stable operation in all seven channel combinations at discharge voltages from 300 V to 500 V and three different current densities. All seven channel combinations demonstrated similar performance at a given discharge voltage and current density. The largest thrust recorded was 5.4 N, and total efficiency and specific impulse ranged from 0.54 to 0.67 and 1800 seconds to 2650 seconds, respectively.In addition to the performance measurements, a suite of plasma diagnostics and a high-speed camera were used to study the operation of the thruster in greater detail. The probe results are compared against those in the literature and demonstrate that the X3, even in multi-channel operation, is producing similar charge, mass, current, and voltage utilization efficiencies as state of the art single-channel Hall thrusters. High-speed camera analysis identified that the X3 operated with similar discharge current oscillations at all conditions tested. Additionally, a preliminary calculation of cross-channel ingestion and its effect on thruster efficiency is made. This work represents the highest total power (102 kW), thrust (5.4 N), and discharge current (247 A) demonstrated by a Hall thruster to date, improvements of 6 percent, 64 percent, and 119 percent respectively over previous values. These results are discussed in the context of continued high-power Hall thruster development and future mission applications.

Hall, Scott James↗

Existing Whole-House Solutions Case Study: Applying Best Practices to Florida Local Government Retrofit Programs - Central Florida

In some communities, local government and non-profit entities have funds to purchase and renovate distressed, foreclosed homes for resale in the affordable housing market. Numerous opportunities to improve whole house energy efficiency are inherent in these comprehensive renovations. BA-PIRC worked together in a multiyear field study making recommendations in individual homes, meanwhile compiling improvement costs, projected energy savings, practical challenges, and labor force factors surrounding common energy-related renovation measures. The field study, Phase 1 of this research, resulted in a set of best practices appropriate to the current labor pool and market conditions in central Florida to achieve projected annual energy savings of 15%-30% and higher. This case study describes Phase 2 of the work where researchers worked with a local government partner to implement and refine the "current best practices". A simulation study was conducted to characterize savings potential under three sets of conditions representing varying replacement needs for energy-related equipment and envelope components. The three scenarios apply readily to the general remodeling industry as for renovation of foreclosed homes for the affordable housing market. The new local government partner, the City of Melbourne, implemented the best practices in a community-scale renovation program that included ten homes in 2012.

30% savings↗

Applying Best Practices to Florida Local Government Retrofit Programs

In some communities, local government and non-profit entities have funds to purchase and renovate distressed, foreclosed homes for resale in the affordable housing market. Numerous opportunities to improve whole house energy efficiency are inherent in these comprehensive renovations. BA-PIRC worked together in a multi-year field study making recommendations in individual homes, meanwhile compiling improvement costs, projected energy savings, practical challenges, and labor force factors surrounding common energy-related renovation measures. The field study, Phase 1 of this research, resulted in a set of best practices appropriate to the current labor pool and market conditions in central Florida to achieve projected annual energy savings of 15-30% and higher. This report describes Phase 2 of the work where researchers worked with a local government partner to implement and refine the 'current best practices.' A simulation study was conducted to characterize savings potential under three sets of conditions representing varying replacement needs for energy-related equipment and envelope components. The three scenarios apply readily to the general remodeling industry as for renovation of foreclosed homes for the affordable housing market. Our new local government partner, the City of Melbourne, implemented the best practices in a community-scale renovation program that included ten homes in 2012.

30% SAVINGS↗

Applying Best Practices to Florida Local Government Retrofit Programs, Central Florida (Fact Sheet)

In some communities, local government and non-profit entities have funds to purchase and renovate distressed, foreclosed homes for resale in the affordable housing market. Numerous opportunities to improve whole house energy efficiency are inherent in these comprehensive renovations. BA-PIRC worked together in a multi-year field study making recommendations in individual homes, meanwhile compiling improvement costs, projected energy savings, practical challenges, and labor force factors surrounding common energy-related renovation measures. The field study, Phase 1 of this research, resulted in a set of best practices appropriate to the current labor pool and market conditions in central Florida to achieve projected annual energy savings of 15-30% and higher. This report describes Phase 2 of the work where researchers worked with a local government partner to implement and refine the "current best practices". A simulation study was conducted to characterize savings potential under three sets of conditions representing varying replacement needs for energy-related equipment and envelope components. The three scenarios apply readily to the general remodeling industry as for renovation of foreclosed homes for the affordable housing market. Our new local government partner, the City of Melbourne, implemented the best practices in a community-scale renovation program that included ten homes in 2012.

30% SAVINGS↗

Initial Flight Test Evaluation of the F-15 ACTIVE Axisymmetric Vectoring Nozzle Performance

A full envelope database of a thrust-vectoring axisymmetric nozzle performance for the Pratt & Whitney Pitch/Yaw Balance Beam Nozzle (P/YBBN) is being developed using the F-15 Advanced Control Technology for Integrated Vehicles (ACTIVE) aircraft. At this time, flight research has been completed for steady-state pitch vector angles up to 20' at an altitude of 30,000 ft from low power settings to maximum afterburner power. The nozzle performance database includes vector forces, internal nozzle pressures, and temperatures all of which can be used for regression analysis modeling. The database was used to substantiate a set of nozzle performance data from wind tunnel testing and computational fluid dynamic analyses. Findings from initial flight research at Mach 0.9 and 1.2 are presented in this paper. The results show that vector efficiency is strongly influenced by power setting. A significant discrepancy in nozzle performance has been discovered between predicted and measured results during vectoring.

Orme, John S.↗

Bounding Methods for Heterogeneous Lidar-derived Navigational Geofences

Safe Unmanned Aerial Vehicle (UAV) operations near the ground require navigation methods that avoid fixed obstacles such as buildings, power lines and trees. Aerial lidar surveys of ground structures are available with the precision and accuracy to geolocate obstacles, but the high volume of raw survey data can exceed the compute power of onboard processors and the rendering ability of ground-based flight planning maps. Representing ground structures with bounding polyhedra instead of point clouds greatly reduces the data size and can enable effective obstacle avoidance, as long as the bounding geometry envelopes the structures with high spatial fidelity. This report describes in detail four methods to compute bounding geometries of ground obstacles from lidar point clouds. The four methods are: 1) 2.5D Maximum Elevation Box, 2) 2.5D Ground Map Extrusion, 3) 3D Bounding Cylinder, and 4) 3D Bounding Box. The methods are applied to five point cloud datasets from lidar surveys of UAV flight research sites in Georgia and Virginia with an average point spacing that ranges from 0.1m to 0.6m. The methods are assessed using survey areas with geometrically heterogeneous ground structures: buildings, vegetation, power lines, and sub-meter structures such as road signs and guy wires. The 2.5D Maximum Elevation Box method is useful for simple structures. The 2.5D Ground Map Extrusion method efficiently encloses vegetation, but requires handdrawn ground footprints. The 3D Bounding Cylinder method excels at enclosing linear structures such as power lines and fences. The 3D Bounding Box method excels at enclosing planar structures such as buildings. The methods are compared on the basis of data compression and boundary fidelity on selected areas. The 2.5D methods yield the highest data compression but the polyhedra produced by them enclose significant amounts of empty space. Boundary fidelity is superior for the 3D methods, though this fidelity comes at the cost of a roughly thirtyfold lower data compression ratio than the 2.5D Maximum Elevation Box method. A mix of these output geometries is proposed for autonomous UAV navigation with limited on-board computing. Both the accuracy and spatial detail of emerging satellite-based survey technology lower than that of aerial lidar scanning survey technology. Sub-meter structures and thin linear structures are not reliably mapped at present by satellite-based surveys.

Moore, Andrew J.↗

Seamless metal-clad fiber-reinforced organic matrix composite structures and process for their manufacture

A metallic outer sleeve is provided which is capable of enveloping a hollow metallic inner member having continuous reinforcing fibers attached to the distal end thereof. The inner member is then introduced into outer sleeve until inner member is completely enveloped by outer sleeve. A liquid matrix member is then injected into space between inner member and outer sleeve. A pressurized heat transfer medium is flowed through the inside of inner member, thereby forming a fiber reinforced matrix composite material. The wall thicknesses of both inner member and outer sleeve are then reduced to the appropriate size by chemical etching, to adjust the thermal expansion coefficient of the metal-clad composite structure to the desired value. thereby forming a fiber reinforced matrix composite material. The wall thicknesses of both inner member and outer sleeve are then reduced to the appropriate size by chemical etching, to adjust the thermal expansion coefficient of the metal-clad composite structure to the desired value. The novelty of this invention resides in the development of a efficient method of producing seamless metal clad fiber reinforced organic matrix composite structures.

Bluck, Raymond M.↗

Benefits Of Automated Construction And Energy Efficiency Measures In Modular Homes

This article builds on and adds to a Buildings XV publication that introduced the Transformative Efficiency and Automation in Modular Homes (TEAMH) project. The TEAMH project sought to develop a scalable solution for producing modular homes with 20-50% energy savings and similar cost relative to site-fabricated single-family home construction. A key aspect of the project was assessing the potential for labor cost reductions through automation-assisted construction using light gauge steel (LGS). To quantify the advantages of this approach, side-by-side comparisons were made between traditional wood-framed construction and automation-assisted LGS construction. This demonstration involved constructing one wood-framed wall and several LGS test walls, accompanied by a time-and-motion study. The results indicated that automation assistance could decrease construction time and associated labor costs by as much as 46%. High-performance envelope technologies for exterior insulation and air sealing were evaluated to compare modular homes with site-built homes that meet the International Energy Conservation Code (IECC). A key technology considered was vacuum insulation panels (VIPs) with fiberglass cores. Guarded hot box testing of multiple full-scale wall assemblies containing different combinations of exterior continuous insulation systems containing phenolic foam and VIPs. Testing on various full-scale wall assemblies revealed that, with LGS construction, cavity insulation had minimal impact on exterior wall performance. Omitting cavity insulation can reduce labor and material costs while streamlining manufacturing, as its installation is labor-intensive and not easily automated due to the need for precise placement around wiring and other internal components. Guarded hot box tests of multiple LGS test walls with foam and VIP-based exterior insulation systems achieved R-values of up to 31 hr-ft2-°F/Btu. Finally, building energy modeling of multiple modular home designs indicated that the upgraded envelope assemblies can yield heating energy savings of up to 50% and cooling energy savings of up to 30% compared to IECC 2018 standards.

Shrestha, Som [ORNL] (ORCID:0000000183993797)↗

Advancing Energy Justice in Alaska

NREL works with remote and rural communities across Alaska and the world to develop energy and building technologies that enhance culture, strengthen economies, and improve resilience in a changing environment. Alaska and Arctic communities not only face one of the harshest climates on earth; they also pay some of the highest energy and housing costs in the nation. NREL's Alaska Campus collaborates with communities and tribes to develop affordable, culturally appropriate homes and buildings that combine traditional knowledge and twenty-first century technology. Demonstration homes deployed all over Alaska prove out new technologies in energy efficiency, foundations, indoor air quality, and clean energy. Local workforce development is incorporated into every project: new homes are built by local workers, often including the home's future occupant. With the Arctic warming twice as fast as the rest of the planet, coastal erosion and thawing permafrost are wreaking havoc on roads, buildings, and infrastructure across Alaska. With an inclusive approach to R&D, NREL is helping communities adapt to a changing environment and advancing energy justice in the world's extremes.

Alaska housing prototypes↗

Correlation between cationic lipid-based transfection and cell division

We evaluate the temporal relation between protein expression by cationic lipid-mediated transfection and cell division using time lapse fluorescence microscopy. Detailed image analysis provides new insights on the single cell level while simultaneously achieving appropriate statistics. Earlier evidence by less direct methods such as flow cytometry indicates a primary route for transfection involving nuclear envelope breakdown, but also suggests the existence of a pathway independent of mitosis. We confirm and quantify both mechanisms. We found the timing for successful transfection to be unexpectedly flexible, contrary to assertions of a narrow time window. Specifically, cells dividing more than 24 h after exposure to the transfection medium express the probed protein at a comparable level to cells in a mitotic state during or shortly after transfection. This finding can have a profound impact on the guidance and development of non-viral gene delivery materials. - Highlights: • Cationic lipid-based transfection supports protein expression without cell division. • Protein expression is unrelated to cell cycle status at the time of transfection. • Time-lapse imaging provides direct evaluation without statistical averaging. • Lipoplex dissociation is a likely target for improvement of transfection efficiency.

60 APPLIED LIFE SCIENCES↗

Predicting Envelope Leakage in Attached Dwellings

The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting Envelope Leakage in Attached Dwellings

The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Vegas: Implementing Energy Efficiency in Two Las Vegas Test Homes

In 2009, the state of Nevada received nearly forty million dollars in Neighborhood Stabilization Funds from the Department of Housing and Urban Development. The purpose of this funding was to stabilize communities that have suffered from foreclosures and abandonment. In an effort to provide guidance to local officials and maximize how effectively this NSP funding is utilized in retrofitting homes, CARB provided design specifications, energy modeling, and technical support for the Building America Retrofit Alliance (BARA) team and its local partners - Better Building Performance, Nevada Energy Star Partners Green Alliance, and Home Free Nevada - for two retrofit test homes. One home was to demonstrate a modest retrofit and the other a deep energy retrofit. Through this project, CARB has provided two robust solution packages for retrofitting homes built in this region between the 1980s and early 1990s without substantially inconveniencing the occupants. The two test homes, the Carmen and Sierra Hills, demonstrate how cost-effectively energy efficient upgrades can be implemented in the hot, dry climate of the Southwest. In addition, the homes were used as an educational experience for home performance professionals, building trades, remodelers, and the general public. In-field trainings on air-sealing, HVAC upgrades, and insulating were provided to local contractors during the retrofit and BARA documented these retrofits through a series of video presentations, beginning with a site survey and concluding with the finished remodel and test out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Envelope Time Synchronous Averaging for Wind Turbine Gearbox Fault Diagnosis

Vibration-based condition monitoring techniques are widely used for diagnosing faults in rotating machines. These techniques are implemented in the time domain, the frequency domain, or both. However, the composite and noisy nature of the raw data collected requires a preprocessing stage such as filtering and decomposition using in-depth processing techniques. Moreover, these methods require good frequency resolution and involve examining a broad frequency range to discern both healthy and faulty cases. In this work, we introduce a simple and fast diagnostic scheme for wind turbine gear teeth wear based on time domain analysis. The proposed method is based on the local minima interpolation of a filtered version of the vibration signal following time synchronous averaging (TSA) technique. Given tachometer signal, the TSA of the vibration data is performed using MTALAB software. Then, local minima of the filtered signal are interpolated using the Piecewise Cubic Hermite Interpolating Polynomial (PCHIP) function. The variance of the interpolated curve built a gear fault index. The derived fault index resulting of the proposed technique allows a substantial distinction between the healthy and faulty cases. Its efficiency is validated using 10 real-world datasets of vibration stemmed from a wind turbine planetary gearbox. The proposed method boasts a low computation time and ease of interpretation, specifically beneficial for gearbox fault diagnosis purposes.

fault diagnosis↗

Experimental space weathering of regolith material

Significant advances in the understanding of space weathering processes were recently reported. Submicroscopic iron blebs were produced in lunar simulant glass and natural terrestrial minerals by high-temperature reduction in controlled atmosphere furnaces. These experiments altered the samples' optical properties and microtextures so that they resembled those of extremely mature lunar soil. The results contributed to a revised model for natural reduction in the regolith. Subsequently, supporting results were obtained by reduction of lunar samples. Research to date has focused on reduction of three lunar surface components: basalt, pyroclastic glass, and mare soil. An extensive set of H reduction experiments with simulants has led to a detailed understanding of reaction mechanisms and kinetics. Reduction experiments using lunar basalt were recently conducted by Carbotek. Reduced samples from these test were analyzed. Reduction experiments on lunar glass 74220 were run at temperatures of 900-1100 C. Reduction efficiency of volcanic glass proved to be a function of the sample's FeO abundance and reaction temperature. We also reduced mare soil 75061 at temperatures of 900-1050 C. Partial reduction of FeO in olivine and pyroxene occurred, but was slower and less complete than reduction of ilmenite. Our experiments on simulants and lunar samples have indicated that the most readily reduced phases in the regolith are ilmenite and glass. Based on initial tests with simulants we proposed refinements to the accepted model for space weathering of the regolith. The impact of a micrometeoroid flash heats and melts and ejects from the impact point a small volume of soil that contains trapped solar wind H and C. Reduction occurs rapidly, while the melt volume is still in motion. When a droplet encounters unmelted soil, it envelopes cold mineral grains. The melt is chilled rapidly. Our analyses of experimentally reduced lunar basalt, glass, and mare soil support the proposed model for space weathering.

Mckay, D. S.↗

Seasonal Locking of the MJO’s Southward Detour of the Maritime Continent: The Role of the Australian Monsoon

Abstract This study investigates why the major convective envelope of the Madden–Julian oscillation (MJO) detours to the south of the Maritime Continent (MC) only during boreal winter [December–March (DJFM)]. To examine processes affecting this MJO detour, the MJO-related variance of precipitation and column-integrated moisture anomalies in DJFM are compared with those in the seasons before [October–November (ON)] and after [April–May (AM)]. While MJO precipitation variance is much higher in the southern MC (SMC) during DJFM than in other seasons, the MJO moisture variance is comparable among the seasons, implying that the seasonal locking of the MJO’s southward detour cannot be explained by the magnitude of moisture anomalies alone. The higher precipitation variance in the SMC region is partly explained by the much higher moisture sensitivity of precipitation in DJFM than in other seasons, resulting in a more efficient conversion of anomalous moisture to anomalous precipitation. DJFM is also distinguishable from the other seasons by stronger positive wind–evaporation feedback onto MJO precipitation anomalies due to the background westerly wind in the lower troposphere. It is found that the seasonal cycle of moisture–precipitation coupling and wind–evaporation feedback in the SMC region closely follows that of the Australian monsoon, which is active exclusively in DJFM. Our results suggest that the MJO’s southward detour in the MC is seasonally locked because it occurs preferentially when the Australian monsoon system produces a background state that is favorable for MJO development in the SMC.

Intraseasonal variability↗

Carbon Abundance Inhomogeneities and Deep Mixing Rates in Galactic Globular Clusters

Among stars in Galactic globular clusters the carbon abundance tends to decrease with increasing luminosity on the upper red giant branch, particularly within the lowest metallicity clusters. While such a phenomena is not predicted by canonical models of stellar interiors and evolution, it is widely held to be the result of some extra mixing operating during red giant branch ascent which transports material exposed to the CN(O)-cycle across the radiative zone in the stellar interior and into the base of the convective envelope, whereupon it is brought rapidly to the stellar surface. Here we present measurements of [C/Fe] abundances among 67 red giants in 19 globular clusters within the Milky Way. Building on the work of Martell et al., we have concentrated on giants with absolute magnitudes of M {sub V} ∼ −1.5 within clusters encompassing a range of metallicity (−2.4 < [Fe/H] < −0.3). The Kitt Peak National Observatory (KPNO) 4 m and Southern Astrophysical Research (SOAR) 4.1 m telescopes were used to obtain spectra covering the λ4300 CH and λ3883 CN bands. The CH absorption features in these spectra have been analyzed via synthetic spectra in order to obtain [C/Fe] abundances. These abundances and the luminosities of the observed stars were used to infer the rate at which C abundances change with time during upper red giant branch evolution (i.e., the mixing efficiency). By establishing rates over a range of metallicity, the dependence of deep mixing on metallicity is explored. We find that the inferred carbon depletion rate decreases as a function of metallicity, although our results are dependent on the initial [C/Fe] composition assumed for each star.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗